Records from 2001 to 2026. Most recent: inspection, 22 May 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 20
22 May 2026
COC-CVE Annual
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8378441
2 May 2025
COC-CVE Annual
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8130351
10 July 2024
COC-CVE Annual
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7955240
19 April 2023
COC-CVE Annual
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7671894
4 May 2021
COC-CVE Annual
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7189336
17 April 2019
Administrative Inspection · COC-CVE Annual
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6664720
18 April 2018
COC-CVE Annual · Deficiency Check · Administrative Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6394261
17 April 2017
COC-CVE Annual · Administrative Inspection
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6126474
12 April 2016
COC-CVE Annual
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5921361
21 April 2009
COC-CVE Annual
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3637000
22 April 2008
COC-CVE Annual
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3199149
9 May 2007
Deficiency Check
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2959593
17 April 2007
COC-CVE Annual
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2909636
18 April 2006
COC-CVE Annual
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2626417
26 July 2005
COC-CVE Annual · Deficiency Check
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 2426311
20 July 2004
COC-CVE Annual
Administrative · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 2139012
29 July 2003
Certificate of Compliance
Administrative · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1860250
8 August 2002
Certificate of Compliance
Administrative · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1658300
13 August 2001
Deficiency Check
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1071447
25 May 2001
Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1417314
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 April 2023
Resolved
Vessels port side wet exhaust had signs of dry rotting and cracking. Vessel owner/operator shall repair or replace the section of exhaust to ensure proper operation.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 May 2023
Resolved 19 April 2023
Resolution: Vessel Owner/Operator replaced the section of wet exhaust pipe with a new one.
Engineering › Bilge Water Management System › Not Operational
Issued 17 April 2007
Resolved
- Prove proper operation of high water bilge alarm.
Due 17 April 2007
Resolved 17 April 2007
Resolution: corrected prior to our departure
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 17 April 2007
Resolved
- Fill holes in deck where component connections pass from engine space to control panel. Engine space must be well sealed to prevent the release of extinguishing agent.
Action required: 705 - Other - as specified
Due 17 April 2007
Resolved 9 May 2007
Resolution: Witnessed satisfactory packing installed for penetrations to engine space.
Construction/Loadline › Structures › Superstructure
Issued 17 April 2007
Resolved
- V/W cracked weld for forward port hand hold.
Action required: 705 - Other - as specified
Due 17 April 2007
Resolved 9 May 2007
Resolution: Witnessed satisfactory repairs.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 17 April 2007
Resolved
- Repair transmission cover for centerline system.
Action required: 705 - Other - as specified
Due 17 April 2007
Resolved 9 May 2007
Resolution: Witnessed satisfactory welding repairs to cover.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 17 April 2007
Resolved
- Replace retro reflective material on ring buoys.
Action required: 705 - Other - as specified
Due 17 April 2007
Resolved 9 May 2007
Resolution: Witnessed satisfactory renew of retro.
Electrical › Electrical Distribution System (service) › Wiring
Issued 17 April 2007
Resolved
- General wiring and hose protection has been applied however 1 hose on the portside forward engine space sitting on deck, as well as 1 wire within engine space, center of space required bundling to prevent chaffing. Several additional chaffing material requires repositioning to adequately protect run.
Action required: 705 - Other - as specified
Due 17 April 2007
Resolved 9 May 2007
Resolution: Witnessed satisfactory installation of chaffing gear.
Fire Fighting › Ventilation Systems › Ducts
Issued 17 April 2007
Resolved
Provide fire damper pin for operator's seat damper.
Action required: 705 - Other - as specified
Due 17 April 2007
Resolved 9 May 2007
Resolution: Witnessed satisfactory operation of fire damper.
Engineering › Bilge Water Management System › Pump
Issued 26 July 2005
Resolved
Properly mount high water alarm in engine space and secure wires appropriately.
Action required: 705 - Other - as specified
Due 5 August 2005
Resolved 10 September 2005
Resolution: Received email confirmation from operations manager attesting to the satisfactory corrective action to issued requirement.
Electrical › Electrical Distribution System (service) › Wiring
Issued 26 July 2005
Resolved
Within engine space electrical wires/cables, fuel hoses and hydraulic hoses requiring chaffing protection and supports to prevent damage as they pass through or over framing.
Action required: 705 - Other - as specified
Due 5 August 2005
Resolved 10 September 2005
Resolution: Received email confirmation from operations manager attesting to the satisfactory corrective action to issued requirement.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 26 July 2005
Resolved
Repair cracks in transverse framing in way of engine space at starboard side forward corner where old, unused fitting is installed.
Action required: 705 - Other - as specified
Due 5 August 2005
Resolved 10 September 2005
Resolution: Received email confirmation from operations manager attesting to the satisfactory corrective action to issued requirement.
Engineering › Fuel Oil Service System › Vent Pipe
Issued 26 July 2005
Resolved
Fuel vents modified using 3//8 hose vice previously installed nominal sized tubing. U.S. regulations provide a minimum sized pipe be used for the ventilation of fuel space, please identify w/ Transport Canada if this modification meets Canadian standards and report finding to this office. Also, in this area old pipe stuffed with rags vice proper marine/fire resistant sealant
Action required: 705 - Other - as specified
Due 5 August 2005
Resolved 7 October 2005
Resolution: Received report form Transport Canada attesting to their examination of vessels and satisfactory completion of issued discrepancies.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 26 July 2005
Resolved
Fuel shutoff valve handle found damaged and not operational as installed. Correct and report corrective action to the satisfaction of attending Transport Canada surveyor.
Action required: 705 - Other - as specified
Due 5 August 2005
Resolved 7 October 2005
Resolution: Received report form Transport Canada attesting to their examination of vessels and satisfactory completion of issued discrepancies.
Operations/Management › Vessel Safety Management › Reports and Analysis
Issued 26 July 2005
Resolved
Provide report from Transport Canada regarding the serviceability of vessel.
Action required: 705 - Other - as specified
Due 5 August 2005
Resolved 7 October 2005
Resolution: Received report form Transport Canada attesting to their examination of vessels and satisfactory completion of issued discrepancies.