Records from 2016 to 2025. Most recent: inspection, 13 May 2025.
Inspection history · 14
13 May 2025
Internal Structural Exam · Drydock Exam · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8111928
3 September 2024
Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7994854
6 June 2023
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7704969
16 May 2023
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7689651
17 May 2022
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7452911
27 May 2021
Administrative Inspection · Annual Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7208024
19 June 2020
COI Inspection · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6974058
5 March 2020
Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6921347
12 March 2019
Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6639040
5 February 2019
Simplified Stability Test · Examination of Repairs · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6623938
18 October 2018
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6561491
2 October 2018
Construction Oversight · Plan Review "T" Boat · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6632537
10 May 2017
Hull Examination · Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6146470
19 July 2016
COI Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5946282
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 3 September 2024
Resolved
(a) Alcohol testing. (1) The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI.
USCG MI observed expired alcohol swabs at inspection.
46 CFR 4.06-15(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 September 2024
Resolved 8 September 2024
Resolution: Recieved objective photographic evidence to clear.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 5 March 2020
Resolved
Make permanent repairs to shaft tube. Vessel reps cut through tube while attempting to remove cutless bearing and was vessel was taking on water.
Action required: 60 - Rectify deficiencies prior to movement
Due 5 March 2020
Resolved 18 March 2020
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 5 February 2019
Resolved
Conduct stability test prior to carrying passengers. Concluded that weight change from repower in 2012 and deck replacement weight change questions vessel's stability.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 April 2019
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 20 July 2016
Resolved
Vessel's Pre-engineered fixed fire extinguishing system must have an audible and visual alarm upon discharge. Prove proper operation of the audible and visual alarm.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 August 2016
Resolved 1 August 2016
Lifesaving › Lifebuoys › Serviceable
Issued 19 July 2016
Resolved
Provide ring buoy IAW 46CFR160.050 Ring buoy must be marked IAW 46CFR185.604(i) and with vessel name.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 August 2016
Resolved 21 July 2016
Resolution: Vessel purchased and tested knew ring buoy meeting CFR compliance.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 19 July 2016
Resolved
Provide floating light for ring buoy IAW 46CFR161.010. Restrict vessel to daylight operations.
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 August 2016
Resolved 21 July 2016
Resolution: Vessel purchased and tested new floating light.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 19 July 2016
Resolved
Prepare Drug and Alcohol program for audit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 August 2016
Resolved 19 October 2016
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 19 July 2016
Resolved
Provide emergency instructions for fire, heavy weather, and man overboard procedures.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 August 2016
Resolved 10 August 2016
Operations/Management › Passenger Operations › Safety Orientation
Issued 19 July 2016
Resolved
Provide a written passenger count that is available ashore at vessel's normal berthing location.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 August 2016
Resolved 10 August 2016