Records from 1988 to 2025. Most recent: inspection, 4 August 2025.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 51
4 August 2025
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 8202702
28 May 2024
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7921663
5 December 2023
Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7834355
29 July 2023
Annual Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7757599
23 May 2022
Annual Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7457551
27 May 2021
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7240414
25 June 2020
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6986961
3 June 2019
DAPI Audit · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6683205
20 May 2019
Deficiency Check
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6688799
20 March 2019
Deficiency Check · Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6645774
30 May 2018
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6430033
17 July 2017
Administrative Inspection · DAPI Audit
Administrative · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6213763
27 June 2017
Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6190591
23 March 2017
Administrative Inspection
Administrative · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6110406
13 May 2016
Administrative Inspection
Administrative · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 5876359
12 May 2016
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 5875673
7 April 2016
Examination of Repairs · Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 5850151
4 April 2016
Administrative Inspection
Administrative · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 5848015
24 June 2014
Administrative Inspection
Administrative · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 4898121
28 May 2014
Hull Examination · COI Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 4877360
20 July 2011
Annual Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 4089216
13 April 2009
DAPI Audit · COI Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 3451467
25 March 2009
Hull Examination
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 3420314
18 March 2009
Simplified Stability Test · Administrative Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 3436115
28 July 2008
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 3282353
29 April 2008
Administrative Inspection
Administrative · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 3191974
3 May 2007
Annual Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 2916259
5 May 2006
Periodic Inspection
Physical examination · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 2650637
11 April 2006
Construction Oversight
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2621747
15 April 2005
Re-Inspection
Physical examination · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 2332991
11 May 2004
Hull Examination · COI Inspection
Physical examination · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 2071109
13 November 2003
Administrative Inspection
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1947238
21 November 2001
Re-Inspection · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1376817
10 November 1999
Deficiency Check · Hull Examination · Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1456779
10 December 1998
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1424701
20 November 1998
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1393023
14 November 1997
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1468838
6 November 1997
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1468839
26 December 1996
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1431724
21 November 1996
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1456428
8 November 1995
Re-Inspection · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1189725
9 February 1995
Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 840671
10 November 1994
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1171714
15 November 1993
Hull Examination · Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1162987
2 August 1993
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1152449
4 November 1992
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1132469
12 November 1991
Hull Examination · Deficiency Check · COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 952431
20 May 1991
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1225693
19 May 1989
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 895182
2 May 1989
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1345827
20 May 1988
Initial Construction-Excluding Oversight · Initial Certification
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 892110
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 August 2025
Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets. Children's life jacket storage does not have the number of items marked on the container. 46 CFR 185.604(f)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 August 2025
Resolved 26 August 2025
Resolution: Operator marked number of childrens life jackets.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 4 August 2025
Resolved
Waste receptacles must be constructed of noncombustible materials with no openings in the sides or bottom. Waste receptacle for vessel is plastic. 46 CFR 177.405(f)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 August 2025
Resolved 22 August 2025
Resolution: Operator provided photo of metallic trash can onboard.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 4 August 2025
Resolved
Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information:(1) Date of the drill and training; and (2) General description of the drill scenario and training topics. Drills being conducted are not being logged to include description of drill scenario and training topic. 46 CFR 185.520(f)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 September 2025
Resolved 26 August 2025
Resolution: Operator logged drill
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 17 June 2024
Resolved
A vessel must carry adequate and up-to-date charts. Vessel's charts are out of date. Replace outdated paper charts.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2024
Resolved 30 July 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 June 2024
Resolved
Vessel must have an adequate lifebuoy. Vessel's lifebuoy is faded, torn, and unserviceable for the season. Replace unserviceable lifebuoy.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2024
Resolved 30 July 2024
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 5 December 2023
Resolved
Starboard head log has new damage on the outboard side from the weld seam of the next section to approx. 1ft to the front and the stabilizer fin has broken welds. Provide plans and repair to the satisfaction of the Coast Guard Marine Inspector.
Action required: 705 - Other - as specified
Resolved 17 May 2024
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 5 December 2023
Resolved
The deck boards are waterlogged and rotting away in a few locations also there is separation on the topside of the deck. Provide plans and repair to the satisfaction of the Coast Guard Marine Inspector.
Action required: 705 - Other - as specified
Resolved 17 May 2024
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 5 December 2023
Resolved
There is a missing nut on of the bolts that attaches the deck to the frame/pontoons (deck frame to pontoon port side 3rd frame from aft). Repair to the satisfaction of the Coast Guard Marine Inspector.
Action required: 705 - Other - as specified
Resolved 17 May 2024
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 December 2023
Resolved
The base of one of the rails is cracked (Port side rail near center cleat).Repair to the satisfaction of the Coast Guard Marine Inspector.
Action required: 705 - Other - as specified
Resolved 17 May 2024
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 5 December 2023
Resolved
The sewage tank needs to be permanently repaired, the previous use of epoxy is now also cracked. (Weld seam crack approx. 6-8”). Provide plans and repair to the satisfaction of the Coast Guard Marine Inspector.
Action required: 705 - Other - as specified
Resolved 17 May 2024
Resolution: TOILET HAS BEEN REMOVED AND TANK HAS BEEN CAPPED OFF
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 5 December 2023
Resolved
One of the connector plates on the deck frame is only hanging on by 01 bolt on the port side. Repair to the satisfaction of the Coast Guard Marine Inspector.
Action required: 705 - Other - as specified
Resolved 17 May 2024
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 5 December 2023
Resolved
The wire bundle going to the starboard engine is deteriorating. All wires should be protected from the weather.
Action required: 705 - Other - as specified
Resolved 17 May 2024
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 5 December 2023
Resolved
Deck frame pitting Port side 2nd frame in from aft under screws. Provide plans and repair to the satisfaction of the Coast Guard Marine Inspector.
Action required: 705 - Other - as specified
Resolved 17 May 2024
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 23 May 2022
Resolved
Provide a complete and unexpired First Aid Kit that complies with 46 CFR 160.041
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2022
Resolved 20 July 2022
Resolution: bought new first aid kit that met the Qspec.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 23 May 2022
Resolved
Post emergency instructions that are specific to your vessels operations and design.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2022
Resolved 3 June 2022
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 23 May 2022
Resolved
Ring life buoy must be marked with Type II Retro-reflective material approved in accordance with 46 CFR 164.018 and must be applied in accordance with IMO Resolution A.658(16)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2022
Resolved 3 June 2022
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 27 May 2021
Resolved
FIRST AID KIT HAD EXPIRED ITEMS
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2021
Resolved 30 May 2021
Resolution: VESSEL BOUGHT NEW FIRST AID KIT
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 25 June 2020
Resolved
Provide onboard a valid Certificate of Documentation with the required COASTWISE endorsement prior to the carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 June 2020
Resolution: Vessel rep sent email receipt confirmation of payment for Coastwise endorsement.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 June 2020
Resolved
Provide on board an approved life jacket for each person permitted on the COI (41). Passenger count is reduced to 28 people until defective life jackets have been replaced with new ones and placed into service on the vessel. The COI states the vessel shall have 10 approved child life jackets on board. Only 06 children are permitted on board the vessel with the current life jackets until 10 new are purchased and placed into service on the vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 August 2020
Resolution: placed in special note
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 25 June 2020
Resolved
Provide on board the appropriate number of approved distress signals.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 July 2020
Resolution: Owner sent pictures of non-expired distress signals.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 25 June 2020
Resolved
Provide on board Aspirin (100 ct) in First Aid Kit in accordance with 46 CFR 160.041.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2020
Resolved 10 July 2020
Resolution: Owner sent picture of appropiate amount of aspirin.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 June 2020
Resolved
Completely remove wire or place wire nut on exposed wire end under operating console.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2020
Resolved 25 July 2020
Resolution: Owner sent phot of corrected wire.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 25 June 2020
Resolved
Replace sun faded fire extinguishers placards on aft deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2020
Resolved 25 July 2020
Resolution: Owner sent photo of replaced signage.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 25 June 2020
Resolved
Provide on board and mount emergency instructions that pertain to the vessel and are in accordance with 46 CFR 185.512.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2020
Resolved 25 July 2020
Resolution: Owner sent photo of posted instructions.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 25 June 2020
Resolved
Conduct and log fire, man overboard and abandon ship drills in accordance with 46 CFR Subpart E. Record of drills will be examined at next annual inspection.
Action required: 705 - Other - as specified
Resolved 17 August 2020
Resolution: will verify at next inspection that drills are being conducted accordingly
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 June 2019
Resolved
Provide appropiate number of PFDs according to COI. 46 CFR 180.71
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 June 2019
Resolution: Verifeid 41 PFDs onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 June 2019
Resolved
Make available for inspection, all additional child sized PFDs. 46 CFR 180.71
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2019
Resolved 19 June 2019
Resolution: Verified additional child sized PFDs.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 June 2019
Resolved
Provide servicable fire extinguisher at helm. 46 CFR 181.500
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 June 2019
Resolution: Verified fire extinguisher at helm is serviceable.
01 - Certificates & Documentation › 013 - Documents › Fire control plan - all
Issued 3 June 2019
Resolved
Replace faded fire extinguisher signs on stern. 46 CFR 176.810
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2019
Resolved 19 June 2019
Resolution: Verified replaced signs for fire extinguishers.
14 - Pollution Prevention › 145 - MARPOL Annex V › Placards
Issued 3 June 2019
Resolved
POst update garbage placard. 46 CFR 185.702
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2019
Resolved 19 June 2019
Resolution: Verified updated garbage placard posted.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 June 2019
Resolved
Post emergency instructions. 46 CFR 185.510
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2019
Resolved 19 June 2019
Resolution: Emergency instructions posted.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 June 2019
Resolved
Replace expired items in First Aid Kit. 46 CFR 184.710
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2019
Resolved 19 June 2019
Resolution: Verified all first aid items were serviceable.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 March 2019
Resolved
Remove and replace broken PVC pipe that holds electrical wire runs under deck of vsl
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 April 2019
Resolved 23 April 2019
Resolution: Removed and replaced broken PVC pipe that holds electrical wire runs under deck of vsl
Lifesaving › Hand Flares › Quantity
Issued 27 June 2017
Resolved
Provide 03 orange hand flares
Action required: 705 - Other - as specified
Due 27 June 2017
Resolved 27 June 2017
Resolution: Corrected on the spot.
Fire Fighting › Fire Bucket › Quantity
Issued 27 June 2017
Resolved
Provide 03 metallic fire buckets.
Action required: 705 - Other - as specified
Due 27 June 2017
Resolved 27 June 2017
Resolution: Corrected on the spot.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 12 May 2016
Resolved
Replace the 60' Life line for the Ring Buoy as required by 46 CFR 180.70(c) and to the satisfaction of the Attending Marine Inspector
Condition: Placed in Improper Service
Due 27 May 2016
Resolved 31 May 2016
Resolution: Vessel replaced 60' life line with bouyant type.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 12 May 2016
Resolved
Vessel is only certified to carry 34 passengers until 7 Coast Guard approved additional type I life jackets are provided on board. Seven of the Life jackets were not serviceable.
Condition: Improper/Lack of Maintenance
Due 30 May 2016
Resolved 31 May 2016
Resolution: Vessel purchased 8 additional Type I life jackets and placed them on board.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 12 May 2016
Resolved
Vessel did not have a complete first aid kit. Kit was missing 10 ammonia inhalants
Condition: Placed in Improper Service
Due 30 May 2016
Resolved 7 June 2016
Resolution: Owner provided reciept of new ammonia inhalants.
Lifesaving › Immersion Suits › Approval
Issued 21 November 2001
Resolved
PROVIDE CREW TRAINING, CONDUCT DRILLS AND LOG THEM.
Condition: Unknown
Due 16 December 2001
Resolved 20 March 2004
Navigation › Piloting/Steering › Marine Charts
Issued 21 November 2001
Resolved
PROVIDE LIGHT LIST, COAST PILOT AND NAV RULES.
Condition: Unknown
Due 16 December 2001
Resolved 20 March 2004
Accommodation/Occupational Safety
Issued 21 November 2001
Resolved
SECURE AFT PLYWOOD BULKHEAD TO VESSEL STRUCTURE.
Condition: Unknown
Due 27 November 2001
Resolved 27 November 2001
Engineering
Issued 21 November 2001
Resolved
PROPERLY VENT FUEL TANKS IAW 46 CFR 182.450
Condition: Unknown
Due 27 November 2001
Resolved 27 November 2001
Electrical › Electrical Distribution System (service) › Busway
Issued 21 November 2001
Resolved
REMOVE DEAD END WIRES FROM FUEL TANK SPACE.
Condition: Unknown
Due 16 December 2001
Resolved 20 March 2004
Construction/Loadline
Issued 21 November 2001
Resolved
PITTING DISCOVERED. REMOVE BOTTOM PAINT FROM PORT SIDE 4TH SECTION AFT FOR INSPECTION.
Condition: Unknown
Due 27 November 2001
Resolved 27 November 2001
Construction/Loadline
Issued 21 November 2001
Resolved
SUBMIT PROPOSAL ON REAPIR OF ENGINE BRACKET(S)
Condition: Unknown
Due 27 November 2001
Resolved 27 November 2001
Lifesaving
Issued 10 November 1999
Resolved
REPAIR/REPLACE RING BUOY LIGHT AND ATTACH 3-6 FT LINE WITH DETACHABLE CLIP.
Condition: Unknown
Due 18 January 2000
Resolved 18 January 2000
Navigation
Issued 10 November 1999
Resolved
INSTALL LIGHT ON MAGNETIC COMPASS.
Condition: Unknown
Due 18 January 2000
Resolved 18 January 2000
Lifesaving
Issued 10 November 1999
Resolved
REPAIR/REPLACE RING BUOY PERIPHERAL LINE.
Condition: Unknown
Due 18 January 2000
Resolved 18 January 2000
Lifesaving
Issued 10 November 1999
Resolved
PROVIDE UPDATED FIRST AID KIT IN ACCORDANCE WITH 46CFR160.041.
Condition: Unknown
Due 18 January 2000
Resolved 18 January 2000
Electrical
Issued 10 November 1999
Resolved
PUT BATTERIES IN TRAYS AND MOUNT TO PREVENT MOVEMENT.
Condition: Unknown
Due 18 January 2000
Resolved 18 January 2000
Lifesaving
Issued 10 November 1999
Resolved
REPAIR/REPLACE 15 ADULT PFDS AND PUT VESSEL NAME ON 6 CHILD PFDS.
Condition: Unknown
Due 18 January 2000
Resolved 18 January 2000
Lifesaving
Issued 20 November 1998
Resolved
INSTALL HALYARD CLIP ON RING BUOY WATERLIGHT LINE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 November 1998
Resolved 20 November 1998
Lifesaving
Issued 20 November 1998
Resolved
INSTALL MEANS OF RELEASING PFD'S FROM OVERHEAD COMPARTMENTS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 November 1998
Resolved 20 November 1998
Lifesaving
Issued 20 November 1998
Resolved
INSTALL RETRO TAPE ON RING BUOY._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 November 1998
Resolved 20 November 1998
Documentation
Issued 14 November 1997
Resolved
PROVIDE CURRENT FCC SAFETY RADIOTELEPHONE CERT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 1 December 1997
Resolved 1 December 1997
Documentation
Issued 14 November 1997
Resolved
PROVIDE CURRENT FCC STATION LICENSE.
Condition: Unknown
Due 1 December 1997
Resolved 1 December 1997
Lifesaving
Issued 21 November 1996
Resolved
RENEW RING BUOY._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 November 1996
Resolved 21 November 1996
Fire Fighting
Issued 21 November 1996
Resolved
PROVIDE 3-2 1/2 GL FIRE BUCKETS WITH LANYARDS ATTACHED TO EACH. LABEL EACH "FIRE BUCKET."_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 November 1996
Resolved 21 November 1996
Fire Fighting
Issued 21 November 1996
Resolved
SERVICE/RENEW 1-BI FIRE EXTINGUISHER._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 November 1996
Resolved 21 November 1996
Fire Fighting
Issued 10 November 1994
Resolved
Affix suitable extension to suction side of hand fire/bilge pump.
Condition: Unknown
Due 10 November 1994
Resolved 10 November 1994
Documentation
Issued 10 November 1994
Resolved
Provide proof vessels document is valid.
Condition: Unknown
Due 10 November 1994
Resolved 10 November 1994
Accommodation/Occupational Safety
Issued 12 November 1991
Resolved
REMOVE CAP OVERBOARD DISCHARGE VALVE FOR SEWAGE TANK HAS ON BOTTOM OF SWEAGE TANK AND INSTALL CONNECTION TO ALLOW PUMING TANK TO A RECEPTION FACILITY ASHORE.
Condition: Unknown
Due 6 December 1991
Resolved 10 January 1992
Engineering
Issued 2 May 1989
Resolved
DEMONSTRATE OPERATION OF PROPULSION ENGINES AND FATHOMETER.
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Electrical
Issued 2 May 1989
Resolved
REMOVE WIRE NUTS AND INSTALL SPLICE IN MSD SWITCH WIRING IN A JUNCTION BOX.
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989