Records from 2003 to 2025. Most recent: inspection, 13 November 2025.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 13 November 2025
Resolved
All other vessels must undergo an inspection for
certification as specified in 176.404 and annual
inspection as specified in paragraph (b)(1) of this
section. Your vessel must undergo an annual inspection
within the 3 months before or after each anniversary
date. Vessel lapsed 1st Annual Inspection, due 24OCT2025
(COI issued 24JUL2024). No scheduled or requested
inspection date. Submit CG-3752 to schedule COI renewal
inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 November 2025
Resolution: Completed COI ren, sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 4 November 2025
Resolved
All other vessels must undergo an inspection for
certification as specified in 176.404 and annual
inspection as specified in paragraph (b)(1) of this
section. Your vessel must undergo an annual inspection
within the 3 months before or after each anniversary
date. Vessel lapsed 1st Annual Inspection, due 24OCT2025
(COI issued 24JUL2024). No scheduled or requested
inspection date. Submit CG-3752 to schedule COI renewal
inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 November 2025
Resolution: Completed COI inspection, sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 19 June 2024
Resolved
A vessel to which this subchapter applies may not be operated without having on board a valid U.S. Coast Guard Certificate of Inspection. Vessel must comply with approved sail plan as described on the Temporary COI or submit a new sail plan.
46CFR115.100 (a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 June 2024
Resolution: Local CID approved new sail plan
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 15 June 2024
Resolved
The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed. Vessel was involved in several collisions, allisions, and groundings during transit from Jacksonville, FL. OCMI to conduct onboard Damage Survey prior to movement. 46 CFR 115.840
Action required: 60 - Rectify deficiencies prior to movement
Resolved 18 June 2024
Resolution: OCMI to conductED onboard Damage Survey.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 15 June 2024
Resolved
The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed. Conduct dry dock or provide dive report of props, shafts, rudders, and underwater appendages due to vessel running aground. 46 CFR 115.840
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 June 2024
Resolution: Vessel provide dive report of props, shafts, rudders, and underwater appendages.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 15 June 2024
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: (1) Charts of large enough scale to make safe navigation possible; (2) U.S. Coast Pilot or similar publication; (3) Coast Guard Light List; (4) Tide tables; and (5) Current tables, or a river current publication issued by the U.S. Army Corps of Engineers or a river authority. Vessel does not have current charts, navigation publications, or tides/current tables.
46 CFR 121.420 (a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 24 June 2024
Resolution: Charts and Nav rules were onboard. Showed representative onboard how to down load Coast Pilot.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 15 June 2024
Resolved
A vessel on a lakes, bays, and sounds, or rivers route must carry: (2) Three hand orange smoke distress signals approved in accordance with § 160.037 in subchapter Q of this chapter, or other standard specified by the Commandant. Vessel only had two of the three orange smoke distress signals onboard.
46 CFR 117.68(b)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 24 June 2024
Resolution: Flares onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 15 June 2024
Resolved
Each vessel without overnight accommodations certificated to operate on a lakes, bays, and sounds route must: (2) If operated in warm water, be provided with life floats of an aggregate capacity that will accommodate at least 50% of the total number of persons permitted on board. Vessel has no ready survival craft. All three of vessel’s life floats are in an unserviceable condition. Additionally, their stowage does not comply with 46 CFR 117.130 and 46 CFR 117.137; and their outfitting does not include the required equipment detailed in 46 CFR 117.175. Rectify prior to operating more than one mile from land.
46 CFR 117.207(b)
Action required: 705 - Other - as specified
Resolved 24 June 2024
Resolution: Vessel not required primary lifesaving due to route and no passengers
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 15 June 2024
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection. Window on starboard side, amidships is shattered.
46 CFR 116.100(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 October 2024
Resolution: Resolved
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 15 June 2024
Resolved
Each vessel must be provided with a visual and audible alarm at the operating station to indicate a high water level in … normally unmanned spaces. Visual alarm for engine room bilge alarm was inoperable.
46 CFR 119.530(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 July 2024
Resolved 16 October 2024
Resolution: Resolved
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 June 2024
Resolved
46CFR115.100(a): A vessel to which this subchapter applies may not be operated without having on board a valid U.S. Coast Guard Certificate of Inspection. Vessels COI authorizes operation within a Lakes, Bays, and Sounds route. Vessel is not authorized to transit beyond the boundary line. Prior to transiting beyond the boundary line, the vessel must stop and coordinate attendance of local marine inspectors from Sector Delaware Bay.
Action required: 705 - Other - as specified
Resolved 16 October 2024
Resolution: Delbay required no action
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 15 June 2024
Resolved
All self-propelled vessels must be fitted with a Federal
Communications Commission (FCC) type accepted general
marine radar system for surface navigation with a radar
screen mounted at the primary operating station. Radar
became inoperable during required tests. Fix or replace
with operable radar array. 46 CFR 121.404
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 August 2024
Resolution: Verified radar working.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 15 June 2024
Resolved
All vessels must have navigation lights that are in
compliance with Navigation Rules, except that a vessel
of more than 19.8 meters (65 feet) in length must
UL1104. Navlights were not of an approved type. Replace
all Nav lights with UL1104 approved fixtures.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 August 2024
Resolution: Verified proper installation and type approval of all navigation lights.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 15 June 2024
Resolved
In addition to the radiotelephone required by paragraph
(b) of this section, each vessel described in paragraph
(a) of this section while transiting any waters within a
Vessel Traffic Service Area, must have on board a
radiotelephone capable of transmitting and receiving on
the VTS designated frequency. Vessel only has one marine
VHF radio installed. Install additional VHF radio.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 August 2024
Resolution: Verified installation of new VHF radio.
09 - Working and Living Conditions › 092 - Working Conditions › Gangway, accommodation-ladder
Issued 15 June 2024
Resolved
At each inspection for certification all observed unsafe
practices, and other hazardous situations must be
corrected and all required guards and protective devices
must be in satisfactory condition. Vessel's bow gangway
support cabling, turnbuckles, shackles, in severely
deteriorated and wasted condition. Replace all support
cabling, turnbuckles, shackles, u-bolt clamps. Vessel is
restricted from using forward gangway to embark/
disembark passengers. 46 CFR 115.830(a)
16Sept update: Wire replaced but saddle clamps installed wrong.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 September 2024
Resolution: Saddle clamps installed
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Ship's occupational safety and health policies and programmes
Issued 15 June 2024
Resolved
Required chemical testing: Employers; must ensure all
agreements an arrangements concerning the implementation
of the Drug and Alcohol testing requirements are in
compliance with these provisions. Vessel's DAPI was
missing valid enrollment letter, listing of employees
enrolled. Ensure required information is included in
plan and properly implemented. 46 CFR 16.203(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 August 2024
Resolution: Verified enrollment, implementation into pre-employment drug testing etc.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 15 June 2024
Resolved
All vessels shall be provided with satisfactory
arrangement for draining any watertight compartment.
Vessel was unable demonstrate successful dewatering
through Void #3 bilge suction line. Repair line and
demonstrate proper operation of bilge suction line. 46 CFR 182.25-1(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 August 2024
Resolution: Verified Bilge suction from Void 3. All sat.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 15 June 2024
Resolved
A-Class bulkheads or decks must be composed of steel. In
addition, they must be so insulated with approved
structural insulation. Two areas identified:
1.)(RE-VERIFY insullation installed within false Overhead) Boundaries between High Risk Accommodation(7) areas
and High Risk Accommodation(7) Areas shall be A-60...
e.g. Deck 1 and Deck 2, insulation in the false overhead
attached to the above deck steel was found to have
fallen from originally installed areas in multiple
locations.
2.)(CLEARED 28AUG2024) Boundaries between Machinery Spaces(10) and High
Risk Accommodation(7) Areas shall be A-60... e.g. Engine
Room and Deck 1, insulation on the overhead was found to
have fallen from originally installed areas in multiple
locations.
Re-install approved structural fire protection
insulation in the above areas.
46 CFR 116.415(a)(2)(i)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 September 2024
Resolution: Insulation replaced with original.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 June 2024
Resolved
A fire hose must be attached to each fire hydrant at all
times. Engine room fire hose brass fitting was found
split rendering the hose ineffective against
manufacture's design. Replace engine room fire hose with
approved UL 19 compliant fire hose. 46 CFR 118.320
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 August 2024
Resolution: Verified new hose.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 15 June 2024
Resolved
At each inspection for certification and at every other
vessel inspection all observed unsafe practices, fire
hazards, and other hazardous situations must be
corrected and all required guards and protective devices
must be in satisfactory condition. Vessel's engine room
bilges was observed to have an excessive accumulation of
oil around all running machinery. Oil absorbent mats
were observed all through out engine room bilges, soaked
through, with pooled oil all around. Remove excessive
oil and clean engine room bilges.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 August 2024
Resolution: Verified engineroom cleanliness.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 15 June 2024
Resolved
A vessel is inspected for compliance with the standards
required by this subchapter. Machinery inspected in
accordance with standards acceptable to the cognizant
OCMI as good marine practice. Engine room was observed
to have Exhaust leak in exhaust piping on machinery. 46 CFR 115.800(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 August 2024
Resolution: Exhaust leaks fixed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 June 2024
Resolved
Battery chargers must have an ammeter connected in the
charging circuit. Battery charger under the bar on the
second deck that powers the forward gangway winch, was
identified to not have an approved ammeter in the
circuit. 46 CFR 120.350(f)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 August 2024
Resolution: Vessel removed battery charger.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 15 June 2024
Resolved
When operating a vessel on a body of water where the
discharge of untreated sewage is prohibited by the
Environmental Protection Agency the operator must secure
each Type III device acceptable methods include: (1)
Closing each valve leading to an overboard discharge and
removing the handle;(2) Padlocking each valve leading to
an overboard discharge in the closed position; or(3)
Using a non-releasable wire-tie to hold each valve
leading to an overboard discharge in the closed
position. Port side discharge valve was observed open.
secure valves to one of the three standards above. 33 CFR 159.7(c)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 August 2024
Resolution: Vessel installed lock on valves with chain.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 15 June 2024
Resolved
A vessel is inspected for compliance with the standards
required by this subchapter. Machinery, equipment,
materials, and arrangements not covered by standards in
this subchapter may be inspected in accordance with
standards acceptable to the cognizant OCMI as good
marine practice. While conducting engineering checks of
operating machinery. Vessel's both main engines and both
auxiliary generators were observed actively leaking oil
out of valve covers. 46 CFR 115.800
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 August 2024
Resolution: Cleared.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 14 June 2024
Resolved
"The area of operation for each vessel and any necessary operational limits are determined by the cognizant OCMI..."
1)Do not enter Sector New York COTP Zone until you have met the requirements outlined below or have been otherwise authorized by the Captain of the Port via the Vessel Traffic Service.
2) All movements and transfer of control within the COTP Zone of New York and New Jersey must be in accordance with a tug assist plan reviewed by Vessel Traffic Service. This tug assist plan must be submitted in writing to this office for review prior to entering the COTP Zone.
3) Coordinate and report movements and towing evolutions within the COTP Zone through Vessel Traffic Service.
46 CFR 115.110(a)
Action required: 705 - Other - as specified
Resolved 3 July 2024
Resolution: Appealed and rescinded
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 3 June 2024
Resolved
Newly- hired vessel employees may be granted the access provided for in the paragraph (a) of this section only if: (1) the new hire has applied for a TWIC in accordance with 49 CFR part 1572... Newly hired engineer has not applied nor hold a VALID TWIC. New engineer/crew must be escorted into areas with restricted access.
33 cfr 104.267
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 August 2024
Resolution: Individual without TWIC no longer works there.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 3 June 2024
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date:Charts.... Inspectors identified that the charts on board were not up to date.
Update charts to recent edition.
46 CFR 121.420
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 August 2024
Resolution: Charts are updated.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 3 June 2024
Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radio beacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the FCC, as set forth in 47 CFR part 80. Inspector identified that the radio equipment on board is without MMSI registration.
46 CFR 121.502
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 August 2024
Resolution: registered.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 3 June 2024
Resolved
Each vessel must be provided with a visual and audible alarm at the operating station to indicate a high water level... Operators informed inspectors that their high water alarm lights were not working as well as not labeled.
46 CFR 119.530
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 August 2024
Resolution: verified operation
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 3 June 2024
Resolved
Windows and other openings at the operating station must be of sufficient size and properly located to provide an adequate view for safe navigation in all operating conditions... Inspectors found motors for wipers removed with exposed wiring on the pilothouse windows.
46 cfr 116.1030
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 September 2024
Resolution: Wire properly installed in new housing.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 3 June 2024
Resolved
Glass and other glazing material used in windows must be of material that will not break into dangerous fragments if fractured... Inspectors found cracked windows and plexiglass. outfit vessel with proper windows
46 CFR 116.1010
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 August 2024
Resolution: provided paperwork from tech install verified tempered glass.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 June 2024
Resolved
Each lifeline on a ring life buoy must:(1) Be buoyant;(2) Be at least 18.3 meters (60 feet) in length;(3) Be non-kinking;(4) Have a diameter of at least 7.9 millimeters (5/16-inch);(5) Have a breaking strength of at least 5 kilonewtons (1,124 pounds); and(6) Be of a dark color if synthetic, or of a type certified to be resistant to deterioration from ultraviolet light. Inspectors identified lifebuoys with lines that were not in conformity with regulations as well as not labeled with vessel's name. Outfit lifebuoys with proper arrangements.
46 cfr 117.70
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 August 2024
Resolution: verified number, marking, and equipment.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 June 2024
Resolved
Each life jacket, immersion suit, and ring life buoy must be marked in clearly legible block capital letters with the vessel's name. Identified lifesaving equipment not labeled with vessel's name. Outfit vessel with lifesaving equipment that is labeled.
46 cfr 122.604
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 August 2024
Resolution: Labeled
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 June 2024
Resolved
A life preserver shall be of a highly visible color, such as Indian Orange, International Orange, or Scarlet Munsell Red. Identified multiple life preservers that have lost its highly visible color. Outfit vessel with proper life perservers. \
46 cfr 160.001
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 August 2024
Resolution: counted required lifejackets verified material condition.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 June 2024
Resolved
panelboard must have:(1) A circuit directory cardholder; and(2) A circuit directory that has:(i) The circuit designation of each circuit;(ii) A description of the load of each circuit; and(iii) The rating or setting of the overcurrent protective device for each circuit. Identified panel in pilothouse to be mislabeled and outdated. Outfit vessel with updated circuit directories for all panels.
UPDATE 28AUG24: Install proper breakr blanks or spare braker in fwd galley pannel. Switch off Spare breakers.
46 CFR 111.40-11
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 September 2024
Resolution: Blank installed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 3 June 2024
Resolved
a weathertight door with permanent watertight coamings that comply with the height requirements in table 171.124(d) must be provided for each opening located in a deck house or companionway that—(1) Gives access into the hull. Identified multiple doors that were not weatherproof. Outfit vessel with weather proof doors.
46 cfr 171.124
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 September 2024
Resolution: Weathertight doors fixed with foam gaskets and adjustments.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 3 June 2024
Resolved
All bulkheads and decks shall be classed as A-60, A-30, A-15, A-0, B-15, B-0, or C, depending upon the type of space on each side of the bulkhead or above and below the deck. Inspectors identified spray foam used to seal deck/bulkhead penetrations in numerous cases on the vessel. Maintain the structural fire protection of decks as required.
46 cfr 72.01-10
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 August 2024
Resolution: cleared
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 30 May 2024
Resolved
The Certificate of Inspection issued to a vessel describes the vessel, the route(s) that it may travel, the minimum manning requirements, the survival and rescue craft carried, the minimum fire extinguishing equipment and lifejackets required to be carried, the maximum number of passengers and total persons that may be carried, the number of passengers the vessel may carry in overnight accommodation spaces, the name of the owner and managing operator, any equivalencies accepted or authorized by the Commandant or any Officer in Charge, Marine Inspection (OCMI) in accordance with § 175.540 or § 175.550 of this chapter, and such other conditions of operations as may be determined by the cognizant OCMI. Prior to the carriage of passengers, have the cognizant OCMI conduct a new to zone inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 June 2024
Resolved 16 October 2024
Resolution: New to zone COI inspection complete.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 30 May 2024
Resolved
Each vessel must have a stability letter issued by the Coast Guard before the vessel is placed into service which sets forth conditions of operation. This vessel is permitted to operate on Protected Waters. Prior to departing Port Canaveral for an intended voyage to New York, provide voyage plan to MSU Port Canaveral for approval in accordance with COTP Order 24-038 issued on 24 May 2024.
Action required: 17 - Rectify deficiencies prior to departure
Due 6 June 2024
Resolved 2 June 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 May 2024
Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment, other than small buoyancy compartments, under all practicable conditions. The bilge pump and secondary bilge pump (fire) do not operate as designed. Prove proper operation of both bilge pumps.
Action required: 17 - Rectify deficiencies prior to departure
Due 31 May 2024
Resolved 30 May 2024
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 24 May 2024
Resolved
A self priming, power driven fire pump must be installed on each vessel. Prove proper operation of the fire pump.
Action required: 17 - Rectify deficiencies prior to departure
Due 31 May 2024
Resolved 30 May 2024
10 - Safety of Navigation › N/A - No Subsystem › Bridge operation
Issued 24 May 2024
Resolved
The owner or managing operator shall be prepared to test the steering systems of the vessel and make them available for inspection to the extent necessary to determine that they are in suitable condition and fit for the service intended. Demonstrate the steering system operates as designed.
Action required: 17 - Rectify deficiencies prior to departure
Due 31 May 2024
Resolved 30 May 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 May 2024
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. The port shaft seal leaks excessively.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 31 May 2024
Resolved 31 May 2024
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 24 May 2024
Resolved
A vessel must be operated in accordance with applicable laws and regulations and in such a manner as to afford adequate precaution against hazards that might endanger the vessel and the persons being transported. The port engine shaft seal leaks excessively. The bilge pumps do not operate as designed. Proper operation of the steering system is in question. Prior to movement, submit plan for rectifying these conditions to the OCMI.
Action required: 60 - Rectify deficiencies prior to movement
Due 31 May 2024
Resolved 30 May 2024
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 10 October 2023
Resolved
Vessel unable to conduct required drills at inspection.
Vessel must conduct & document required training and drills for fire, man overboard, abandon ship.
46CFR122.520
46CFR122.524
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 October 2023
Resolved 16 October 2024
Resolution: Conducted new to zone COI inspection
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 2 March 2021
Resolved
ALL VESSELS SHALL BE PROVIDED WITH NOT LESS THAN TWO AVENUES OF ESCAPE FROM ALL GENERAL AREAS ACCESSIBLE TO THE PASSENGERS OR WHERE THE CREW MAY BE QUARTERED OR NORMALLY EMPLOYED. MAIN DECK FORWARD EGRESS ROUTE DOOR IS BLOCKED BY A BROW AND EQUIPMENT. MAKE EGRESS ROUTE CLEAR.
46 CFR 177.15-1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 3 March 2021
Resolved 23 March 2021
Resolution: egress route cleared, equipment moved and brow was removed from vessel
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 2 March 2021
Resolved
VESSELS SHALL BE INSPECTED FOR COMPLIANCE WITH STANDARDS REQUIRED BY THIS SUBCHAPTER. FOR ITEMS NOT COVERED, INSPECT IN ACCORDANCE WITH STANDARDS ACCEPTABLE TO [name withheld] MUST BE CAPABLE OF WITHSTANDING THE MAXIMUM LOAD FROM CONDITIONS EXPECTED DUE TO ITS LOCATION ON THE VESSEL AND AUTHORIZED ROUTE. REPLACE BROKEN WINDOW ON PORT SIDE MAIN DECK.
46 CFR 176.25-1
46 CFR 116.1020
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 3 March 2021
Resolved 23 March 2021
Resolution: window was replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 2 March 2021
Resolved
RAILS SHALL BE INSTALLED NEAR THE PERIPHERY OF ALL WEATHER DECKS ACCESSIBLE TO PASSENGERS AND CREW. FOC’SLE HAND RAIL HAS BEEN BROKEN OFF OF ITS MOUNTS BY THE FORWARD “DECORATIVE” BROW.
46 CFR 177.35-1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 2 March 2021
Resolved 23 March 2021
Resolution: rail was welded back in place, sat
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 2 March 2021
Resolved
MARINE INSPECTOR SHALL VIEW AND CONDUCT THE FOLLOWING TEST AND INSPECTION: TEST BY OPERATION ALL WATERTIGHT CLOSURES IN THE HULL, DECKS AND BULKHEADS. MAKE ENG ROOM WATERTIGHT DOOR CLOSE PROPERLY.
46 CFR 176.25-5
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 3 March 2021
Resolved 23 March 2021
Resolution: watertight door closed satisfactorily
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 2 March 2021
Resolved
EXAMINE ALL WEATHERTIGHT CLOSURES ABOVE WEATHER DECK. STARBOARD DOORS ON MAIN AND SECOND DECK EXHIBIT LARGE AREAS OF MATERIAL WASTAGE AT DOOR BOTTOMS. REPAIR AS ORIGINAL.
46 CFR 176.25-5(A)(5)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 March 2021
Resolved 7 December 2023
Resolution: Starboard main and second deck weather tight door and door frame bottom and door frame sides repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 March 2021
Resolved
THE TWO REQUIRED FIXED POWER BILGE PUMPS SHALL BE SELF-PRIMING AND SHALL BE DRIVEN BY DIFFERENT SOURCES OF POWER. MAIN DIESEL ENGINE DRIVEN PUMP WOULD NOT PRIME. ENSURE PUMP IS OPERATIONAL AS DESIGNED.
46 CFR 182.25-10(C)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 3 March 2021
Resolved 23 March 2021
Resolution: witnessed operation of engine driven pump with pressure at the forward hose
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 March 2021
Resolved
ALL WIRING SHALL BE RUN AS HIGH AS PRACTICABLE ABOVE THE BILGES. MOUNT GENERATOR STARTER ELECTRICAL WIRING OUT OF THE BILGE.
46 CFR 183.05-50(a)(1)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 March 2021
Resolved 23 March 2021
Resolution: witnessed wiring mounted in brackets out of the bilge
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 March 2021
Resolved
ALL ELECTRICAL INSTALLATIONS SHALL BE TO THE SATISFACTION OF THE [name withheld] IN GALLEY. REATTACH THE OUTLET RECEPTACLE IN AFT ENGINE ROOM.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 March 2021
Resolved 23 March 2021
Resolution: breaker panels satisfactorily labeled
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 March 2021
Resolved
CABLES ENTERING BOXES OR FITTINGS SHALL BE PROTECTED FROM ABRASION. CABLES LEADING INTO THE PORT GENERATOR JUNCTION BOX NEED TO BE PROTECTED.
46 CFR 183.10-20(F)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 March 2021
Resolved 23 March 2021
Resolution: cables bundled together and wrapped in electrical tape to prevent further abrasion from the generator junction box
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 2 March 2021
Resolved
THE TANK OPENING IN WAY OF PIPE CONNECTIONS SHALL BE PROPERLY REINFORCED WHERE NECESSARY. FUEL FILL PIPE IS WASTED AT WHERE IT INTERSECTS THE MAIN DECK. RENEW AS ORIGINAL.
46 CFR 182.20-22(C)(5)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 March 2021
Resolved 23 March 2021
Resolution: observed renewed piping
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 2 March 2021
Resolved
VESSELS NOT EQUIPPED WITH A SINGLE SOURCE EMERGENCY LIGHTING SYSTEM SHALL HAVE INDIVIDUAL STORAGE BATTERY POWERED AUTOMATICALLY OPERATED LIGHTS IN STRATEGIC LOCATIONS. 2ND DECK EMERGENCY LIGHTING INSTALLATION WAS NOT OPERABLE.
46 CFR 184.30-5(B)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 3 March 2021
Resolved 23 March 2021
Resolution: satisfactorily tested the emergency lighting on second deck
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 March 2021
Resolved
WHERE LIFE PRESERVERS ARE STOWED… THE CONTAINERS IN WHICH THEY ARE STOWED SHALL BE MARKED “LIFE PRESERVERS” AND WITH THE NUMBER CONTAINED THEREIN. LIFE JACKET STORAGE LOCATION FORWARD OF OPERATING STATION 3RD DECK WAS NOT PROPERLY LABELED.
46 CFR 180.25-15(B)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 March 2021
Resolved 23 March 2021
Resolution: MI observed new labeling on storage locations
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 March 2021
Resolved
EACH RING LIFE BUOY MUST BE MARKED WITH TYPE II RETROREFLECTIVE MATERIAL. REPLACE WORN RETROREFLECTIVE TAPE ON RING LIFE BUOYS.
46 CFR 122.604(I)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 March 2021
Resolved 23 March 2021
Resolution: observed satisfactory retro on ring life buoy
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 March 2021
Resolved
EACH LIFE JACKET MUST BE MARKED WITH TYPE I RETROREFLECTIVE MATERIAL. REPLACE WORN RETROREFLECTIVE TAPE ON SEPARATED LIFE JACKETS.
46 CFR 122.604(H)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 March 2021
Resolved 23 March 2021
Resolution: observed satisfactory retroreflective tape on lifejackets
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 29 October 2020
Resolved
To maintain a valid Certificate of Inspection, you must complete your annual inspection within the periods specified in 115.500(2)(b)(1) [annual inspection within 3 months before or after each anniversary date] and your Certificate of Inspection must be endorsed. Vessel is outside of three month window for Inspection and is not permitted to operate until annual inspection has been completed.
46 CFR 115.502
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 30 October 2020
Resolved 23 March 2021
Resolution: Vessel had annual inspection scheduled for 02MAR2021. Inspection held with deficiencies issued, MISLE activity 7123940
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 23 October 2019
Resolved
Emergency exit in the tool room is improperly labeled. Properly label emergency exit. 46CFR185.30-15
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 October 2019
Resolution: Properly labeled the emergency exit.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 October 2019
Resolved
Fuel strainer not of marine type and leaks. Ensure fuel filter on main engine is of a marine type and does not leak. 46CFR182.20-40(B)(5)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 October 2019
Resolution: Both strainers were replaced with marine type units.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 October 2019
Resolved
Battery cables were laying across the metal deck. Permanently install generator starter cables. 46CFR183.01-15(a)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 October 2019
Resolution: Battery cable were replaced and rerouted along the deck framing.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 23 October 2019
Resolved
Insulation throughout the engine room missing. Replace insulation is all areas where it is missing. 46CFR177.10-05 &
46CFR72.05-10(c)(1)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 October 2019
Resolution: Missing insulation was replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 23 October 2019
Resolved
Starboard generator cover has approximately 3 inch hole. Ensure hole is properly covered. 46CFR183.10-10(a)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 October 2019
Resolution: Opening in the generator doghouse was covered.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 October 2019
Resolved
Electrical receptacle in tool room. Receptacle needs to be removed. 46CFR183.01-15(a)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 October 2019
Resolution: Receptacle was removed and junction box was covered.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 October 2019
Resolved
Emergency fuel shut off valve is not labeled or attached. Fuel shot off valve should be properly labeled and reattached. 46CFR185.30-20(a)
46CFR182.20-40(b)(3)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 October 2019
Resolution: Shut off valve was reattached and properly labeled.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 23 October 2019
Resolved
AIS is inoperable. AIS should be properly put back in service. 33CFR164.46(b)(1)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 October 2019
Resolution: AIS was installed properly.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 23 October 2019
Resolved
Magnetic compass light inoperable. Light to be installed properly. 46CFR121.42
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 October 2019
Resolution: Compass light was provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 October 2019
Resolved
Ring buoy forward of the pilot house has worn retro reflective tape. Replace with proper retro reflective tape. 46CFR180.30-1(a)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 October 2019
Resolution: Retroreflective tape was provided.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 23 October 2019
Resolved
Cables through engine room bulkhead compromise the structural fire protection of the bulkhead. Cables through bulkhead should be properly sealed to meet fire rating of bulkhead. 46CFR183.01-15(a)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 October 2019
Resolution: Cables were properly sealed.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 15 July 2019
Resolved
Vessel not in operation/nor carrying any passengers. Vessel under contract for sale. Vessel did not provide crew to conduct MOB, Fire, Security drills. Vessel must conduct drills in the presence of a marine inspector prior to the carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 October 2019
Resolution: Drills were conducted satisfactorily.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 July 2019
Resolved
Vessel did not have annual testing records identifying the total number of individuals tested and test results. Vessel must provide annual testing records. The MIS report will satisfy these requirements.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2019
Resolved 23 October 2019
Resolution: Vessel representative provided documentation showing pre-employment and annual random drug testing.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 1 July 2019
Resolved
Annual overdue
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 July 2019
Resolution: Annual scheduled 7/15/19
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 12 October 2018
Resolved
182.20-40(B)(3) The shut off valve at the tank shall be operable from outside the tank compartment. The is not operable from outside the compartment, the reach rod and valve handle is not connected to the valve stem.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 October 2018
Resolved 15 July 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 October 2018
Resolved
183.350(f) Battery charges must have an ammeter connected in the charger circuit. There is a battery installation under the main deck bar with a battery charger that is not equipped with an ammeter.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 October 2018
Resolved 15 July 2019
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 12 October 2018
Resolved
185.30-15 All escape hatches shall be marked on both sides using at least 1 inch letters “Emergency Exit, Keep Clear.” The engine room escape hatch was not labeled on both sides.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 October 2018
Resolved 15 July 2019
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 12 October 2018
Resolved
180.78(a)(5) Child Life Jackets must be stowed separately from adult life jackets. Throughout the vessel, child and adult life jackets were stored together.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 October 2018
Resolved 15 July 2019
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 1 October 2018
Resolved
Vsl’s measured length in FT (Vsl dimension Must be measured in meters), Vsl is broadcasting incomplete dimension information (AIS Antenna Position “X” equals 0) and Vsl is not broadcasting static draft information
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 30 October 2019
Resolution: AIS is operational.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 30 April 2018
Resolved
Vessel must insert electrical blanks in the following breaker panels: operating station & galley.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 May 2018
Resolution: Blanks installed
Engineering › Bilge Water Management System › Strainer
Issued 30 April 2018
Resolved
Vessel must install a proper bilge suction strainer in the following locations: Laz & Void #2.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 May 2018
Resolution: Proper strainers installed.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 30 April 2018
Resolved
Replace all expired first aid kit items.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 May 2018
Resolution: First aid kit items replaced.
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 30 April 2018
Resolved
Replace all plastic trash cans or relocate to ensure a potential fire would be limited to the receptacle.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 May 2018
Resolution: All plastic trashcans replaced with metal.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 30 April 2018
Resolved
Remove compressed gas cylinder from the vessel or provide proper storage.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 May 2018
Resolution: Gas cylinder removed.
Fire Fighting › Combustible Materials › Stowage
Issued 30 April 2018
Resolved
Remove all flammable materials from the vessels "workshop" or provide proper storage container.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 May 2018
Resolution: All flammable materials removed from the vessel.
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 30 April 2018
Resolved
All wiring must be properly fitted in all electrical fixtures in the following locations: Eng rm/Soda rm.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 May 2018
Resolution: All wires properly mounted in their fixtures.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 30 April 2018
Resolved
Properly sanitize all bar areas.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 May 2018
Resolution: All areas properly sanitized.
Construction/Loadline › Penetrations › Gasket
Issued 30 April 2018
Resolved
Replace the watertight gaskets for the following fixtures: Engine Room Door & Bow Hatch.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 May 2018
Resolution: Gaskets replaced.
Fire Fighting › Combustible Materials › Insulation
Issued 30 April 2018
Resolved
Remove and replace all oil soaked lagging on the STBD Generator.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 May 2018
Resolution: All lagging replaced.
Documentation › Logs/Records › Declaration of Inspection
Issued 30 April 2018
Resolved
Have an authorized engine manufacturer's representative evaluate all oil leaking by into the exhaust manifold's of both service generators and provide technicians report to the Coast Guard.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 May 2018
Resolution: Repair report provided. Exhaust manifold gaskets were found to be the cause and we're replaced by JBL engine mechanics.
Documentation › Safety/Response Plans/Programs › Damage Stability Calculation Program/Plans
Issued 4 August 2017
Resolved
Vessel must submit 1.13% lightship change as calculated by LeMole Architecure letter dated August 3, 2017 to the MSC.
Action required: 705 - Other - as specified
Due 18 August 2017
Resolved 17 August 2017
Resolution: Vessel submitted lightship changes to MSC for review.
Documentation › Safety/Response Plans/Programs › Damage Stability Calculation Program/Plans
Issued 4 August 2017
Resolved
Pending results of a stability calculations by MSC, vessel is restricted to 575 pax, 605 total persons on board.
Action required: 705 - Other - as specified
Resolved 5 September 2017
Resolution: MSC determined a 1.13% lightship change not requiring a new stability test. See MSC letter H2-1703356 dated 29AUG2017.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 4 August 2017
Resolved
Vessel must ensure all speakers and light trees are secure while underway.
Action required: 705 - Other - as specified
Due 18 August 2017
Resolved 17 August 2017
Resolution: Vessel secured all speakers and light trees with metal brackets to preventing a hazard to passengers during vessel movement.
Electrical › Lighting (service) › Lighting Fixture
Issued 4 August 2017
Resolved
Vessel must install covers over all engine room lights.
Action required: 705 - Other - as specified
Due 4 September 2017
Resolved 5 September 2017
Resolution: Vessel installed new covers over all lights.
Fire Fighting › Structural - A Class Divisions › Windows
Issued 4 August 2017
Resolved
Vessel must replace broken window, portside, main deck aft.
Action required: 705 - Other - as specified
Due 4 September 2017
Resolved 5 September 2017
Resolution: Vessel replaced broken window.
Electrical › Electric Supply System (service) › Battery Charger
Issued 4 August 2017
Resolved
Vessel must repair or replace battery charger amp meter.
Action required: 705 - Other - as specified
Due 4 September 2017
Resolved 5 September 2017
Resolution: Vessel replaced battery charger amp meter.
Documentation › Safety/Response Plans/Programs › General Arrangement Plans
Issued 4 August 2017
Resolved
Vessel must update/revise and submit for approval the electrical one line diagram w/ load analysis.
Action required: 705 - Other - as specified
Due 4 September 2017
Resolved 5 September 2017
Resolution: Vessel submitted updated electrical one line diagram.
Documentation › Safety/Response Plans/Programs › General Arrangement Plans
Issued 27 July 2017
Resolved
Alterations to the vessel were made without permission to include: new upper deck bar, lighting, wiring, outlets and air conditioning units. Vessel must submit an electrical one line diagram, load analysis and a material list/ spec sheets for work completed. 46CFR115.700
Action required: 705 - Other - as specified
Due 3 August 2017
Resolved 4 August 2017
Resolution: Vessel removed all new wiring, provided material list and weight information for bar and removed a/c unit.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 27 July 2017
Resolved
Vessel's ground detection meter does not work. Vessel must repair or replace and prove proper operation. 46CFR120.200 (b)
Action required: 705 - Other - as specified
Due 4 September 2017
Resolved 5 September 2017
Resolution: Vessel replaced amp meter and proved proper operation.
Electrical › Lighting (service) › Outlet Box
Issued 27 July 2017
Resolved
Vessel must ensure all electrical equipment exposed to the weather is in a watertight and corrosion resistant enclosure. 46CFR120.210 (b & c)
Action required: 705 - Other - as specified
Due 3 August 2017
Resolved 4 August 2017
Resolution: Vessel replaced all enclosures with new watertight/corrosion resistant enclosures.
Documentation › Safety/Response Plans/Programs › General Arrangement Plans
Issued 27 July 2017
Resolved
Due to changes in the vessel's general arrangement, vessel must submit an updated general arrangement drawing. 46CFR115.700 (b)
Action required: 705 - Other - as specified
Due 4 September 2017
Resolved 5 September 2017
Resolution: Vessel submitted a new general arrangement drawing showing new bar on the upper deck.
Operations/Management › Vessel Safety Management › Company Responsibilities/Authority
Issued 27 July 2017
Resolved
Vessel must submit all weight change (additions & subtractions) to the OCMI for review. 46CFR170
Action required: 705 - Other - as specified
Due 3 August 2017
Resolved 4 August 2017
Resolution: Vessel provided revised lightship values to the OCMI for review. A new deficiency will be issued for MSC submission.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 8 July 2016
Resolved
Provide company drug policy and employee assistance program. 46 CFR16.401
Due 9 July 2016
Resolved 5 August 2016
Resolution: Provided proof of company drug policy and employee assistance program to the satisfaction of the attending Coast Guard Marine Inspector.
Engineering › Bilge Water Management System › Not Operational
Issued 24 June 2016
Resolved
Repair High Water Alarm that’s designated for the Forward Peak Hold. The audible portion of the alarm is currently not working.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 June 2016
Resolved 8 July 2016
Resolution: Verified the repairs to the High Water Alarm that’s designated for the Forward Peak Hold. The audible portion of the alarm is currently operational.
Construction/Loadline › Structures › Scuttle
Issued 24 June 2016
Resolved
Replace the missing “opening device (ex. “T” handle) for the engine room emergency escape scuttle. The device must be located on the main deck within close vicinity of the scuttle.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 June 2016
Resolved 8 July 2016
Resolution: Vessel owner replaced the missing “opening device (ex. “T” handle) for the engine room emergency escape scuttle. ALL SAT to the satisfaction of the attending Coast Guard Marine Inspector.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 24 June 2016
Resolved
Repair the emergency lighting located on the 02 Deck in way of the forward portion of the dance floor.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 June 2016
Resolved 8 July 2016
Resolution: Verified repairs to the emergency lighting located on the 02 Deck in way of the forward portion of the dance floor.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 24 June 2016
Resolved
Replace retro-reflective tape on life jackets and forward main deck life ring, as per 46 CFR 185.604
Due 25 June 2016
Resolved 8 July 2016
Resolution: The retro-reflective tape on life jackets and forward main deck life ring have been renewed to the satisfaction of the attending Coast Guard Marine Inspector.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 24 June 2016
Resolved
Ensure annual servicing of portable fire extinguishers is conducted, as per 46 CFR 181.30-1
Due 25 June 2016
Resolved 8 July 2016
Resolution: Verified that the annual servicing of portable fire extinguishers was conducted.
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 24 June 2016
Resolved
Repair the secondary containment located on the exterior of the vessel in way of the starboard mid-section.
Due 25 June 2016
Resolved 8 July 2016
Resolution: Verified repairs to the secondary containment located on the exterior of the vessel in way of the starboard mid-section.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 24 June 2016
Resolved
Ensure all crew members are enrolled and pre-employment testing is conducted as per required DAPI Program (as per 46 CFR 16.201)
Due 25 June 2016
Resolved 8 July 2016
Resolution: Verified that all crew members are enrolled and pre-employment testing was conducted as per required DAPI Program.
Deck/Cargo › Cargo Stowage › General
Issued 24 June 2016
Resolved
Conduct general clean-up and remove and reorganize miscellaneous items in the bar hold.
Due 25 June 2016
Resolved 5 August 2016
Resolution: Verified that general clean-up and remove and reorganization of the miscellaneous items in the bar hold.
Lifesaving › Hand Flares › Quantity
Issued 4 February 2016
Resolved
Vessel was missing three (3) Red hand held flares
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 March 2016
Resolved 5 April 2016
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 4 February 2016
Resolved
Provide Orifginal copy of Certificate of Documentation and maintain onboard vessel
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 March 2016
Resolved 5 April 2016
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 4 February 2016
Resolved
Renew FCC Radio Safety Certificate
Due 4 March 2016
Resolved 5 April 2016
Documentation › Certificates/Documents › FCC SSL
Issued 4 February 2016
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Due 4 March 2016
Resolved 5 April 2016
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 4 February 2016
Resolved
Vessel All around Anchor light inoperable.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 March 2016
Resolved 5 April 2016
Communications › Public Address System › Loudspeaker
Issued 4 February 2016
Resolved
Vessel PA System inoperable. Prove proper operation of PA System.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 March 2016
Resolved 5 April 2016
Communications › Alarms/Indicators › High Water Alarm
Issued 4 February 2016
Resolved
Vessels High Water Alarms in all spaces were inoperable. Prove proper operation of all HW Alarms
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 March 2016
Resolved 5 April 2016
Engineering › Compressed Air System (control) › Compressor
Issued 4 February 2016
Resolved
STBD Side Air Compressor on vessel not operating in a proper working condition.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 March 2016
Resolved 5 April 2016
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 4 February 2016
Resolved
Vessel Structural Fire Protection insulation in Engine room and Muffler room needs to be secured in various locations.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 March 2016
Resolved 5 April 2016
Construction/Loadline › Structures › Scuttle
Issued 4 February 2016
Resolved
Make repairs and prove proper operation of the escape hatch/scuttle in engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 March 2016
Resolved 5 April 2016
Construction/Loadline › Structures › Scuttle
Issued 4 February 2016
Resolved
Make repairs and prove proper operation of the escape hatch/scuttle in muffler room.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 March 2016
Resolved 5 April 2016
Fire Fighting › Means of Escape › Emergency Lighting
Issued 4 February 2016
Resolved
Vessels Emergency lights were inoperable. Prove proper operation of emergency lighting system.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 March 2016
Resolved 5 April 2016
Lifesaving › Lifebuoys › Serviceable
Issued 4 February 2016
Resolved
Add one (01) Ring Lifebouy to make a total of three (3) onboard. One Lifebuoy removed due to cracked serfice.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 March 2016
Resolved 5 April 2016
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 4 February 2016
Resolved
Need to add (01) Floating Lights to Lifebuoy as required.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 March 2016
Resolved 5 April 2016
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 4 February 2016
Resolved
Remove adhesive residue from deck to avoid tripping/slipping hazards.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 March 2016
Resolved 5 April 2016
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 4 February 2016
Resolved
Add and secure High Temp lagging/insulation on Port and Starboard Engines and generators in areas missing or not secured.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 March 2016
Resolved 5 April 2016
Engineering › Diesel Engine (propulsion-direct drive) › Pump, High Pressure (fuel injection)
Issued 4 February 2016
Resolved
Provide chaffing gear on Stbd engine fuel pump line to avoid chaffing of line on engine.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 March 2016
Resolved 5 April 2016
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 4 February 2016
Resolved
Prior to recovering 1st deck floor covering, provide material specifications to the cognizant OCMI to ensure correct fire rating.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 July 2016
Resolution: Provided material specifications to the cognizant OCMI as to the correct fire rating.