MAURY USCG vessel records Sign in
← All vessels

SIR WINSTON

SIR WINSTON is a 1988 passenger vessel (inspected). The Coast Guard has recorded 109 inspections since 1988, most recently in November 2025, along with 293 deficiencies, 4 operational controls and 5 casualty investigations between 2003 and 2025.

Records from 1988 to 2025. Most recent: inspection, 13 November 2025.

Built
1988
Last inspected
13 November 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDP2182
302592
Flag
UNITED STATES
367773010, 368333930
Maury page id
psix-302592

Inspections, by type

…with no type recorded23
Years with a record 34 calendar years (1988–2025)
The 109 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)92.3 ft × 34.0 ft × 6.6 ft
Registered tonnagegross 97 / net 60
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSERVICE MARINE INDUSTRIES · AMELIA, LA, UNITED STATES · built 1988
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portALVA, FL
Trade endorsementsCoastwise, unrestricted, Recreational, Registry
DocumentationValid · issued 10 February 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it97 - Regulatory (Subpart C or D), Gross Ton
60 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDP2182MMSI 368333930 · active · compulsorily equipped · granted 19 September 2023, expires 19 September 2033
WDJ3954MMSI 367773010 · active · compulsorily equipped · granted 14 February 2017, expires 14 February 2027 · licensed under a name not among this hull’s recorded names (not shown)
WDI6448MMSI 367718810 · expired · compulsorily equipped · granted 3 March 2016, cancelled 9 May 2026 · licensed under a name not among this hull’s recorded names (not shown)
WDD5661MMSI 367161640 · expired · compulsorily equipped · granted 19 January 2007, cancelled 25 March 2017
WCY4955MMSI not assigned · expired · voluntarily equipped · granted 24 June 1998, cancelled 30 August 2008
WCN8994MMSI not assigned · expired · compulsorily equipped · granted 24 October 1994, cancelled 25 December 2004
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 109

13 November 2025 COI Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8267834
4 November 2025 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8264176
20 October 2025 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8255397
17 October 2025 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8256398
15 June 2024 In-Service Inspection · Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7935338
14 June 2024 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7934827
4 June 2024 In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7927240
3 June 2024 COI Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7925916
24 May 2024 Deficiency Check · Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7918622
24 May 2024 Type not recorded
No type recorded · Station Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7918783
24 May 2024 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7949735
20 March 2024 Examination of Repairs · Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7882396
10 October 2023 Deadweight Survey · Deficiency Check · Inclining Experiment · COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7807032
27 January 2022 Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7386373
13 January 2021 Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7123940
29 October 2020 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7086495
22 January 2020 Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6893631
23 October 2019 In-Service Inspection · Administrative Inspection · MTSA Verification · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6840137
15 July 2019 In-Service Inspection · MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6750419
1 July 2019 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6732105
12 October 2018 In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6560267
1 October 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6552349
27 August 2018 In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6523945
30 April 2018 Deficiency Check · Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6407988
22 December 2017 Internal Structural Exam · Hull Examination · Examination of Repairs
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6326776
27 July 2017 In-Service Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6222656
24 March 2017 In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6111231
4 February 2016 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5810148
11 January 2016 Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5795464
9 December 2015 Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5810131
3 October 2014 Security Breach
Type not classified · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5000606
29 June 2014 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4908338
19 May 2014 Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4864264
1 May 2014 Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4848744
20 March 2014 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4819628
1 December 2010 Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3902216
22 March 2010 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3727584
4 February 2010 Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3675424
5 November 2008 Internal Structural Exam · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3357732
27 May 2008 Deficiency Check · Annual Inspection · MTSA Verification
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3206942
29 January 2007 In-Service Inspection · MTSA Verification · COI Inspection · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2863200
16 May 2006 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 2663159
10 May 2006 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2645424
22 February 2006 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2589698
25 January 2006 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2572948
23 January 2006 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2602200
3 February 2005 Periodic Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2285779
18 January 2005 MTSA Verification
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2277452
16 August 2004 In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2167313
17 February 2004 Periodic Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2011449
16 December 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1968372
18 August 2003 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1880043
2 April 2003 Annual Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1766428
12 February 2003 Examination of Repairs · Damage Survey
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1738045
30 January 2003 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1737885
6 March 2002 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1492666
22 January 2002 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1483981
21 March 2001 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1413891
6 April 2000 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1048656
13 March 2000 Plan Review "T" Boat
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 819113
10 January 2000 Plan Review "T" Boat
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1046337
23 May 1999 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 84556
14 April 1999 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1124019
11 March 1999 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1415142
6 August 1998 Damage Survey · Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1440042
4 August 1998 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 121779
30 April 1998 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1123646
19 March 1998 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1368656
20 November 1997 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1396825
3 November 1997 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 781589
12 July 1997 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 93561
18 April 1997 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1104979
5 March 1997 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1442526
13 March 1996 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1390215
9 December 1995 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 229672
7 April 1995 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1358716
15 March 1995 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1401998
15 July 1994 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 654348
4 July 1994 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 214119
24 May 1994 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1019904
15 March 1994 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1431330
3 December 1993 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1415922
16 March 1993 COI Inspection · Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 837098
28 January 1993 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1138642
20 November 1992 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 830754
12 November 1992 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 961159
16 July 1992 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1140990
5 June 1992 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 3283
19 March 1992 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1255852
14 February 1992 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 952211
30 January 1992 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1007602
29 November 1991 Examination of Repairs
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1366706
25 November 1991 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1257055
21 October 1991 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1265995
23 May 1991 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1236541
17 May 1991 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 922309
10 May 1991 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 925541
9 April 1991 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 925934
20 March 1991 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 920926
11 May 1990 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1241095
10 May 1990 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 933269
10 May 1990 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1236848
11 April 1989 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 891518
26 September 1988 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1194996
25 August 1988 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1348964
20 July 1988 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1348282
1 July 1988 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1040877
27 May 1988 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1204446
2 May 1988 Initial Certification · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1205066

Deficiency record · 293

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 13 November 2025 Resolved
All other vessels must undergo an inspection for certification as specified in 176.404 and annual inspection as specified in paragraph (b)(1) of this section. Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel lapsed 1st Annual Inspection, due 24OCT2025 (COI issued 24JUL2024). No scheduled or requested inspection date. Submit CG-3752 to schedule COI renewal inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 November 2025
Resolution: Completed COI ren, sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 4 November 2025 Resolved
All other vessels must undergo an inspection for certification as specified in 176.404 and annual inspection as specified in paragraph (b)(1) of this section. Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel lapsed 1st Annual Inspection, due 24OCT2025 (COI issued 24JUL2024). No scheduled or requested inspection date. Submit CG-3752 to schedule COI renewal inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 November 2025
Resolution: Completed COI inspection, sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 19 June 2024 Resolved
A vessel to which this subchapter applies may not be operated without having on board a valid U.S. Coast Guard Certificate of Inspection. Vessel must comply with approved sail plan as described on the Temporary COI or submit a new sail plan. 46CFR115.100 (a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 June 2024
Resolution: Local CID approved new sail plan
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 15 June 2024 Resolved
The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed. Vessel was involved in several collisions, allisions, and groundings during transit from Jacksonville, FL. OCMI to conduct onboard Damage Survey prior to movement. 46 CFR 115.840
Action required: 60 - Rectify deficiencies prior to movement
Resolved 18 June 2024
Resolution: OCMI to conductED onboard Damage Survey.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 15 June 2024 Resolved
The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed. Conduct dry dock or provide dive report of props, shafts, rudders, and underwater appendages due to vessel running aground. 46 CFR 115.840
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 June 2024
Resolution: Vessel provide dive report of props, shafts, rudders, and underwater appendages.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 15 June 2024 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: (1) Charts of large enough scale to make safe navigation possible; (2) U.S. Coast Pilot or similar publication; (3) Coast Guard Light List; (4) Tide tables; and (5) Current tables, or a river current publication issued by the U.S. Army Corps of Engineers or a river authority. Vessel does not have current charts, navigation publications, or tides/current tables. 46 CFR 121.420 (a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 24 June 2024
Resolution: Charts and Nav rules were onboard. Showed representative onboard how to down load Coast Pilot.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 15 June 2024 Resolved
A vessel on a lakes, bays, and sounds, or rivers route must carry: (2) Three hand orange smoke distress signals approved in accordance with § 160.037 in subchapter Q of this chapter, or other standard specified by the Commandant. Vessel only had two of the three orange smoke distress signals onboard. 46 CFR 117.68(b)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 24 June 2024
Resolution: Flares onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 15 June 2024 Resolved
Each vessel without overnight accommodations certificated to operate on a lakes, bays, and sounds route must: (2) If operated in warm water, be provided with life floats of an aggregate capacity that will accommodate at least 50% of the total number of persons permitted on board. Vessel has no ready survival craft. All three of vessel’s life floats are in an unserviceable condition. Additionally, their stowage does not comply with 46 CFR 117.130 and 46 CFR 117.137; and their outfitting does not include the required equipment detailed in 46 CFR 117.175. Rectify prior to operating more than one mile from land. 46 CFR 117.207(b)
Action required: 705 - Other - as specified
Resolved 24 June 2024
Resolution: Vessel not required primary lifesaving due to route and no passengers
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 15 June 2024 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection. Window on starboard side, amidships is shattered. 46 CFR 116.100(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 October 2024
Resolution: Resolved
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 15 June 2024 Resolved
Each vessel must be provided with a visual and audible alarm at the operating station to indicate a high water level in … normally unmanned spaces. Visual alarm for engine room bilge alarm was inoperable. 46 CFR 119.530(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 July 2024
Resolved 16 October 2024
Resolution: Resolved
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 June 2024 Resolved
46CFR115.100(a): A vessel to which this subchapter applies may not be operated without having on board a valid U.S. Coast Guard Certificate of Inspection. Vessels COI authorizes operation within a Lakes, Bays, and Sounds route. Vessel is not authorized to transit beyond the boundary line. Prior to transiting beyond the boundary line, the vessel must stop and coordinate attendance of local marine inspectors from Sector Delaware Bay.
Action required: 705 - Other - as specified
Resolved 16 October 2024
Resolution: Delbay required no action
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 15 June 2024 Resolved
All self-propelled vessels must be fitted with a Federal Communications Commission (FCC) type accepted general marine radar system for surface navigation with a radar screen mounted at the primary operating station. Radar became inoperable during required tests. Fix or replace with operable radar array. 46 CFR 121.404
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 August 2024
Resolution: Verified radar working.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 15 June 2024 Resolved
All vessels must have navigation lights that are in compliance with Navigation Rules, except that a vessel of more than 19.8 meters (65 feet) in length must UL1104. Navlights were not of an approved type. Replace all Nav lights with UL1104 approved fixtures.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 August 2024
Resolution: Verified proper installation and type approval of all navigation lights.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 15 June 2024 Resolved
In addition to the radiotelephone required by paragraph (b) of this section, each vessel described in paragraph (a) of this section while transiting any waters within a Vessel Traffic Service Area, must have on board a radiotelephone capable of transmitting and receiving on the VTS designated frequency. Vessel only has one marine VHF radio installed. Install additional VHF radio.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 August 2024
Resolution: Verified installation of new VHF radio.
09 - Working and Living Conditions › 092 - Working Conditions › Gangway, accommodation-ladder
Issued 15 June 2024 Resolved
At each inspection for certification all observed unsafe practices, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Vessel's bow gangway support cabling, turnbuckles, shackles, in severely deteriorated and wasted condition. Replace all support cabling, turnbuckles, shackles, u-bolt clamps. Vessel is restricted from using forward gangway to embark/ disembark passengers. 46 CFR 115.830(a) 16Sept update: Wire replaced but saddle clamps installed wrong.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 September 2024
Resolution: Saddle clamps installed
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Ship's occupational safety and health policies and programmes
Issued 15 June 2024 Resolved
Required chemical testing: Employers; must ensure all agreements an arrangements concerning the implementation of the Drug and Alcohol testing requirements are in compliance with these provisions. Vessel's DAPI was missing valid enrollment letter, listing of employees enrolled. Ensure required information is included in plan and properly implemented. 46 CFR 16.203(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 August 2024
Resolution: Verified enrollment, implementation into pre-employment drug testing etc.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 15 June 2024 Resolved
All vessels shall be provided with satisfactory arrangement for draining any watertight compartment. Vessel was unable demonstrate successful dewatering through Void #3 bilge suction line. Repair line and demonstrate proper operation of bilge suction line. 46 CFR 182.25-1(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 August 2024
Resolution: Verified Bilge suction from Void 3. All sat.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 15 June 2024 Resolved
A-Class bulkheads or decks must be composed of steel. In addition, they must be so insulated with approved structural insulation. Two areas identified: 1.)(RE-VERIFY insullation installed within false Overhead) Boundaries between High Risk Accommodation(7) areas and High Risk Accommodation(7) Areas shall be A-60... e.g. Deck 1 and Deck 2, insulation in the false overhead attached to the above deck steel was found to have fallen from originally installed areas in multiple locations. 2.)(CLEARED 28AUG2024) Boundaries between Machinery Spaces(10) and High Risk Accommodation(7) Areas shall be A-60... e.g. Engine Room and Deck 1, insulation on the overhead was found to have fallen from originally installed areas in multiple locations. Re-install approved structural fire protection insulation in the above areas. 46 CFR 116.415(a)(2)(i)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 September 2024
Resolution: Insulation replaced with original.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 June 2024 Resolved
A fire hose must be attached to each fire hydrant at all times. Engine room fire hose brass fitting was found split rendering the hose ineffective against manufacture's design. Replace engine room fire hose with approved UL 19 compliant fire hose. 46 CFR 118.320
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 August 2024
Resolution: Verified new hose.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 15 June 2024 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Vessel's engine room bilges was observed to have an excessive accumulation of oil around all running machinery. Oil absorbent mats were observed all through out engine room bilges, soaked through, with pooled oil all around. Remove excessive oil and clean engine room bilges.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 August 2024
Resolution: Verified engineroom cleanliness.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 15 June 2024 Resolved
A vessel is inspected for compliance with the standards required by this subchapter. Machinery inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. Engine room was observed to have Exhaust leak in exhaust piping on machinery. 46 CFR 115.800(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 August 2024
Resolution: Exhaust leaks fixed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 June 2024 Resolved
Battery chargers must have an ammeter connected in the charging circuit. Battery charger under the bar on the second deck that powers the forward gangway winch, was identified to not have an approved ammeter in the circuit. 46 CFR 120.350(f)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 August 2024
Resolution: Vessel removed battery charger.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 15 June 2024 Resolved
When operating a vessel on a body of water where the discharge of untreated sewage is prohibited by the Environmental Protection Agency the operator must secure each Type III device acceptable methods include: (1) Closing each valve leading to an overboard discharge and removing the handle;(2) Padlocking each valve leading to an overboard discharge in the closed position; or(3) Using a non-releasable wire-tie to hold each valve leading to an overboard discharge in the closed position. Port side discharge valve was observed open. secure valves to one of the three standards above. 33 CFR 159.7(c)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 August 2024
Resolution: Vessel installed lock on valves with chain.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 15 June 2024 Resolved
A vessel is inspected for compliance with the standards required by this subchapter. Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. While conducting engineering checks of operating machinery. Vessel's both main engines and both auxiliary generators were observed actively leaking oil out of valve covers. 46 CFR 115.800
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 August 2024
Resolution: Cleared.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 14 June 2024 Resolved
"The area of operation for each vessel and any necessary operational limits are determined by the cognizant OCMI..." 1)Do not enter Sector New York COTP Zone until you have met the requirements outlined below or have been otherwise authorized by the Captain of the Port via the Vessel Traffic Service. 2) All movements and transfer of control within the COTP Zone of New York and New Jersey must be in accordance with a tug assist plan reviewed by Vessel Traffic Service. This tug assist plan must be submitted in writing to this office for review prior to entering the COTP Zone. 3) Coordinate and report movements and towing evolutions within the COTP Zone through Vessel Traffic Service. 46 CFR 115.110(a)
Action required: 705 - Other - as specified
Resolved 3 July 2024
Resolution: Appealed and rescinded
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 3 June 2024 Resolved
Newly- hired vessel employees may be granted the access provided for in the paragraph (a) of this section only if: (1) the new hire has applied for a TWIC in accordance with 49 CFR part 1572... Newly hired engineer has not applied nor hold a VALID TWIC. New engineer/crew must be escorted into areas with restricted access. 33 cfr 104.267
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 August 2024
Resolution: Individual without TWIC no longer works there.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 3 June 2024 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date:Charts.... Inspectors identified that the charts on board were not up to date. Update charts to recent edition. 46 CFR 121.420
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 August 2024
Resolution: Charts are updated.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 3 June 2024 Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radio beacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the FCC, as set forth in 47 CFR part 80. Inspector identified that the radio equipment on board is without MMSI registration. 46 CFR 121.502
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 August 2024
Resolution: registered.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 3 June 2024 Resolved
Each vessel must be provided with a visual and audible alarm at the operating station to indicate a high water level... Operators informed inspectors that their high water alarm lights were not working as well as not labeled. 46 CFR 119.530
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 August 2024
Resolution: verified operation
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 3 June 2024 Resolved
Windows and other openings at the operating station must be of sufficient size and properly located to provide an adequate view for safe navigation in all operating conditions... Inspectors found motors for wipers removed with exposed wiring on the pilothouse windows. 46 cfr 116.1030
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 September 2024
Resolution: Wire properly installed in new housing.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 3 June 2024 Resolved
Glass and other glazing material used in windows must be of material that will not break into dangerous fragments if fractured... Inspectors found cracked windows and plexiglass. outfit vessel with proper windows 46 CFR 116.1010
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 August 2024
Resolution: provided paperwork from tech install verified tempered glass.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 June 2024 Resolved
Each lifeline on a ring life buoy must:(1) Be buoyant;(2) Be at least 18.3 meters (60 feet) in length;(3) Be non-kinking;(4) Have a diameter of at least 7.9 millimeters (5/16-inch);(5) Have a breaking strength of at least 5 kilonewtons (1,124 pounds); and(6) Be of a dark color if synthetic, or of a type certified to be resistant to deterioration from ultraviolet light. Inspectors identified lifebuoys with lines that were not in conformity with regulations as well as not labeled with vessel's name. Outfit lifebuoys with proper arrangements. 46 cfr 117.70
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 August 2024
Resolution: verified number, marking, and equipment.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 June 2024 Resolved
Each life jacket, immersion suit, and ring life buoy must be marked in clearly legible block capital letters with the vessel's name. Identified lifesaving equipment not labeled with vessel's name. Outfit vessel with lifesaving equipment that is labeled. 46 cfr 122.604
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 August 2024
Resolution: Labeled
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 June 2024 Resolved
A life preserver shall be of a highly visible color, such as Indian Orange, International Orange, or Scarlet Munsell Red. Identified multiple life preservers that have lost its highly visible color. Outfit vessel with proper life perservers. \ 46 cfr 160.001
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 August 2024
Resolution: counted required lifejackets verified material condition.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 June 2024 Resolved
panelboard must have:(1) A circuit directory cardholder; and(2) A circuit directory that has:(i) The circuit designation of each circuit;(ii) A description of the load of each circuit; and(iii) The rating or setting of the overcurrent protective device for each circuit. Identified panel in pilothouse to be mislabeled and outdated. Outfit vessel with updated circuit directories for all panels. UPDATE 28AUG24: Install proper breakr blanks or spare braker in fwd galley pannel. Switch off Spare breakers. 46 CFR 111.40-11
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 September 2024
Resolution: Blank installed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 3 June 2024 Resolved
a weathertight door with permanent watertight coamings that comply with the height requirements in table 171.124(d) must be provided for each opening located in a deck house or companionway that—(1) Gives access into the hull. Identified multiple doors that were not weatherproof. Outfit vessel with weather proof doors. 46 cfr 171.124
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 September 2024
Resolution: Weathertight doors fixed with foam gaskets and adjustments.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 3 June 2024 Resolved
All bulkheads and decks shall be classed as A-60, A-30, A-15, A-0, B-15, B-0, or C, depending upon the type of space on each side of the bulkhead or above and below the deck. Inspectors identified spray foam used to seal deck/bulkhead penetrations in numerous cases on the vessel. Maintain the structural fire protection of decks as required. 46 cfr 72.01-10
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 August 2024
Resolution: cleared
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 30 May 2024 Resolved
The Certificate of Inspection issued to a vessel describes the vessel, the route(s) that it may travel, the minimum manning requirements, the survival and rescue craft carried, the minimum fire extinguishing equipment and lifejackets required to be carried, the maximum number of passengers and total persons that may be carried, the number of passengers the vessel may carry in overnight accommodation spaces, the name of the owner and managing operator, any equivalencies accepted or authorized by the Commandant or any Officer in Charge, Marine Inspection (OCMI) in accordance with § 175.540 or § 175.550 of this chapter, and such other conditions of operations as may be determined by the cognizant OCMI. Prior to the carriage of passengers, have the cognizant OCMI conduct a new to zone inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 June 2024
Resolved 16 October 2024
Resolution: New to zone COI inspection complete.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 30 May 2024 Resolved
Each vessel must have a stability letter issued by the Coast Guard before the vessel is placed into service which sets forth conditions of operation. This vessel is permitted to operate on Protected Waters. Prior to departing Port Canaveral for an intended voyage to New York, provide voyage plan to MSU Port Canaveral for approval in accordance with COTP Order 24-038 issued on 24 May 2024.
Action required: 17 - Rectify deficiencies prior to departure
Due 6 June 2024
Resolved 2 June 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 May 2024 Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment, other than small buoyancy compartments, under all practicable conditions. The bilge pump and secondary bilge pump (fire) do not operate as designed. Prove proper operation of both bilge pumps.
Action required: 17 - Rectify deficiencies prior to departure
Due 31 May 2024
Resolved 30 May 2024
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 24 May 2024 Resolved
A self priming, power driven fire pump must be installed on each vessel. Prove proper operation of the fire pump.
Action required: 17 - Rectify deficiencies prior to departure
Due 31 May 2024
Resolved 30 May 2024
10 - Safety of Navigation › N/A - No Subsystem › Bridge operation
Issued 24 May 2024 Resolved
The owner or managing operator shall be prepared to test the steering systems of the vessel and make them available for inspection to the extent necessary to determine that they are in suitable condition and fit for the service intended. Demonstrate the steering system operates as designed.
Action required: 17 - Rectify deficiencies prior to departure
Due 31 May 2024
Resolved 30 May 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 May 2024 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. The port shaft seal leaks excessively.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 31 May 2024
Resolved 31 May 2024
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 24 May 2024 Resolved
A vessel must be operated in accordance with applicable laws and regulations and in such a manner as to afford adequate precaution against hazards that might endanger the vessel and the persons being transported. The port engine shaft seal leaks excessively. The bilge pumps do not operate as designed. Proper operation of the steering system is in question. Prior to movement, submit plan for rectifying these conditions to the OCMI.
Action required: 60 - Rectify deficiencies prior to movement
Due 31 May 2024
Resolved 30 May 2024
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 10 October 2023 Resolved
Vessel unable to conduct required drills at inspection. Vessel must conduct & document required training and drills for fire, man overboard, abandon ship. 46CFR122.520 46CFR122.524
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 October 2023
Resolved 16 October 2024
Resolution: Conducted new to zone COI inspection
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 2 March 2021 Resolved
ALL VESSELS SHALL BE PROVIDED WITH NOT LESS THAN TWO AVENUES OF ESCAPE FROM ALL GENERAL AREAS ACCESSIBLE TO THE PASSENGERS OR WHERE THE CREW MAY BE QUARTERED OR NORMALLY EMPLOYED. MAIN DECK FORWARD EGRESS ROUTE DOOR IS BLOCKED BY A BROW AND EQUIPMENT. MAKE EGRESS ROUTE CLEAR. 46 CFR 177.15-1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 3 March 2021
Resolved 23 March 2021
Resolution: egress route cleared, equipment moved and brow was removed from vessel
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 2 March 2021 Resolved
VESSELS SHALL BE INSPECTED FOR COMPLIANCE WITH STANDARDS REQUIRED BY THIS SUBCHAPTER. FOR ITEMS NOT COVERED, INSPECT IN ACCORDANCE WITH STANDARDS ACCEPTABLE TO [name withheld] MUST BE CAPABLE OF WITHSTANDING THE MAXIMUM LOAD FROM CONDITIONS EXPECTED DUE TO ITS LOCATION ON THE VESSEL AND AUTHORIZED ROUTE. REPLACE BROKEN WINDOW ON PORT SIDE MAIN DECK. 46 CFR 176.25-1 46 CFR 116.1020
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 3 March 2021
Resolved 23 March 2021
Resolution: window was replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 2 March 2021 Resolved
RAILS SHALL BE INSTALLED NEAR THE PERIPHERY OF ALL WEATHER DECKS ACCESSIBLE TO PASSENGERS AND CREW. FOC’SLE HAND RAIL HAS BEEN BROKEN OFF OF ITS MOUNTS BY THE FORWARD “DECORATIVE” BROW. 46 CFR 177.35-1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 2 March 2021
Resolved 23 March 2021
Resolution: rail was welded back in place, sat
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 2 March 2021 Resolved
MARINE INSPECTOR SHALL VIEW AND CONDUCT THE FOLLOWING TEST AND INSPECTION: TEST BY OPERATION ALL WATERTIGHT CLOSURES IN THE HULL, DECKS AND BULKHEADS. MAKE ENG ROOM WATERTIGHT DOOR CLOSE PROPERLY. 46 CFR 176.25-5
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 3 March 2021
Resolved 23 March 2021
Resolution: watertight door closed satisfactorily
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 2 March 2021 Resolved
EXAMINE ALL WEATHERTIGHT CLOSURES ABOVE WEATHER DECK. STARBOARD DOORS ON MAIN AND SECOND DECK EXHIBIT LARGE AREAS OF MATERIAL WASTAGE AT DOOR BOTTOMS. REPAIR AS ORIGINAL. 46 CFR 176.25-5(A)(5)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 March 2021
Resolved 7 December 2023
Resolution: Starboard main and second deck weather tight door and door frame bottom and door frame sides repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 March 2021 Resolved
THE TWO REQUIRED FIXED POWER BILGE PUMPS SHALL BE SELF-PRIMING AND SHALL BE DRIVEN BY DIFFERENT SOURCES OF POWER. MAIN DIESEL ENGINE DRIVEN PUMP WOULD NOT PRIME. ENSURE PUMP IS OPERATIONAL AS DESIGNED. 46 CFR 182.25-10(C)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 3 March 2021
Resolved 23 March 2021
Resolution: witnessed operation of engine driven pump with pressure at the forward hose
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 March 2021 Resolved
ALL WIRING SHALL BE RUN AS HIGH AS PRACTICABLE ABOVE THE BILGES. MOUNT GENERATOR STARTER ELECTRICAL WIRING OUT OF THE BILGE. 46 CFR 183.05-50(a)(1)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 March 2021
Resolved 23 March 2021
Resolution: witnessed wiring mounted in brackets out of the bilge
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 March 2021 Resolved
ALL ELECTRICAL INSTALLATIONS SHALL BE TO THE SATISFACTION OF THE [name withheld] IN GALLEY. REATTACH THE OUTLET RECEPTACLE IN AFT ENGINE ROOM.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 March 2021
Resolved 23 March 2021
Resolution: breaker panels satisfactorily labeled
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 March 2021 Resolved
CABLES ENTERING BOXES OR FITTINGS SHALL BE PROTECTED FROM ABRASION. CABLES LEADING INTO THE PORT GENERATOR JUNCTION BOX NEED TO BE PROTECTED. 46 CFR 183.10-20(F)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 March 2021
Resolved 23 March 2021
Resolution: cables bundled together and wrapped in electrical tape to prevent further abrasion from the generator junction box
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 2 March 2021 Resolved
THE TANK OPENING IN WAY OF PIPE CONNECTIONS SHALL BE PROPERLY REINFORCED WHERE NECESSARY. FUEL FILL PIPE IS WASTED AT WHERE IT INTERSECTS THE MAIN DECK. RENEW AS ORIGINAL. 46 CFR 182.20-22(C)(5)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 March 2021
Resolved 23 March 2021
Resolution: observed renewed piping
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 2 March 2021 Resolved
VESSELS NOT EQUIPPED WITH A SINGLE SOURCE EMERGENCY LIGHTING SYSTEM SHALL HAVE INDIVIDUAL STORAGE BATTERY POWERED AUTOMATICALLY OPERATED LIGHTS IN STRATEGIC LOCATIONS. 2ND DECK EMERGENCY LIGHTING INSTALLATION WAS NOT OPERABLE. 46 CFR 184.30-5(B)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 3 March 2021
Resolved 23 March 2021
Resolution: satisfactorily tested the emergency lighting on second deck
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 March 2021 Resolved
WHERE LIFE PRESERVERS ARE STOWED… THE CONTAINERS IN WHICH THEY ARE STOWED SHALL BE MARKED “LIFE PRESERVERS” AND WITH THE NUMBER CONTAINED THEREIN. LIFE JACKET STORAGE LOCATION FORWARD OF OPERATING STATION 3RD DECK WAS NOT PROPERLY LABELED. 46 CFR 180.25-15(B)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 March 2021
Resolved 23 March 2021
Resolution: MI observed new labeling on storage locations
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 March 2021 Resolved
EACH RING LIFE BUOY MUST BE MARKED WITH TYPE II RETROREFLECTIVE MATERIAL. REPLACE WORN RETROREFLECTIVE TAPE ON RING LIFE BUOYS. 46 CFR 122.604(I)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 March 2021
Resolved 23 March 2021
Resolution: observed satisfactory retro on ring life buoy
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 March 2021 Resolved
EACH LIFE JACKET MUST BE MARKED WITH TYPE I RETROREFLECTIVE MATERIAL. REPLACE WORN RETROREFLECTIVE TAPE ON SEPARATED LIFE JACKETS. 46 CFR 122.604(H)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 March 2021
Resolved 23 March 2021
Resolution: observed satisfactory retroreflective tape on lifejackets
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 29 October 2020 Resolved
To maintain a valid Certificate of Inspection, you must complete your annual inspection within the periods specified in 115.500(2)(b)(1) [annual inspection within 3 months before or after each anniversary date] and your Certificate of Inspection must be endorsed. Vessel is outside of three month window for Inspection and is not permitted to operate until annual inspection has been completed. 46 CFR 115.502
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 30 October 2020
Resolved 23 March 2021
Resolution: Vessel had annual inspection scheduled for 02MAR2021. Inspection held with deficiencies issued, MISLE activity 7123940
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 23 October 2019 Resolved
Emergency exit in the tool room is improperly labeled. Properly label emergency exit. 46CFR185.30-15
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 October 2019
Resolution: Properly labeled the emergency exit.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 October 2019 Resolved
Fuel strainer not of marine type and leaks. Ensure fuel filter on main engine is of a marine type and does not leak. 46CFR182.20-40(B)(5)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 October 2019
Resolution: Both strainers were replaced with marine type units.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 October 2019 Resolved
Battery cables were laying across the metal deck. Permanently install generator starter cables. 46CFR183.01-15(a)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 October 2019
Resolution: Battery cable were replaced and rerouted along the deck framing.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 23 October 2019 Resolved
Insulation throughout the engine room missing. Replace insulation is all areas where it is missing. 46CFR177.10-05 & 46CFR72.05-10(c)(1)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 October 2019
Resolution: Missing insulation was replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 23 October 2019 Resolved
Starboard generator cover has approximately 3 inch hole. Ensure hole is properly covered. 46CFR183.10-10(a)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 October 2019
Resolution: Opening in the generator doghouse was covered.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 October 2019 Resolved
Electrical receptacle in tool room. Receptacle needs to be removed. 46CFR183.01-15(a)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 October 2019
Resolution: Receptacle was removed and junction box was covered.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 October 2019 Resolved
Emergency fuel shut off valve is not labeled or attached. Fuel shot off valve should be properly labeled and reattached. 46CFR185.30-20(a) 46CFR182.20-40(b)(3)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 October 2019
Resolution: Shut off valve was reattached and properly labeled.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 23 October 2019 Resolved
AIS is inoperable. AIS should be properly put back in service. 33CFR164.46(b)(1)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 October 2019
Resolution: AIS was installed properly.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 23 October 2019 Resolved
Magnetic compass light inoperable. Light to be installed properly. 46CFR121.42
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 October 2019
Resolution: Compass light was provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 October 2019 Resolved
Ring buoy forward of the pilot house has worn retro reflective tape. Replace with proper retro reflective tape. 46CFR180.30-1(a)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 October 2019
Resolution: Retroreflective tape was provided.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 23 October 2019 Resolved
Cables through engine room bulkhead compromise the structural fire protection of the bulkhead. Cables through bulkhead should be properly sealed to meet fire rating of bulkhead. 46CFR183.01-15(a)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 October 2019
Resolution: Cables were properly sealed.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 15 July 2019 Resolved
Vessel not in operation/nor carrying any passengers. Vessel under contract for sale. Vessel did not provide crew to conduct MOB, Fire, Security drills. Vessel must conduct drills in the presence of a marine inspector prior to the carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 October 2019
Resolution: Drills were conducted satisfactorily.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 July 2019 Resolved
Vessel did not have annual testing records identifying the total number of individuals tested and test results. Vessel must provide annual testing records. The MIS report will satisfy these requirements.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2019
Resolved 23 October 2019
Resolution: Vessel representative provided documentation showing pre-employment and annual random drug testing.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 1 July 2019 Resolved
Annual overdue
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 July 2019
Resolution: Annual scheduled 7/15/19
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 12 October 2018 Resolved
182.20-40(B)(3) The shut off valve at the tank shall be operable from outside the tank compartment. The is not operable from outside the compartment, the reach rod and valve handle is not connected to the valve stem.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 October 2018
Resolved 15 July 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 October 2018 Resolved
183.350(f) Battery charges must have an ammeter connected in the charger circuit. There is a battery installation under the main deck bar with a battery charger that is not equipped with an ammeter.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 October 2018
Resolved 15 July 2019
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 12 October 2018 Resolved
185.30-15 All escape hatches shall be marked on both sides using at least 1 inch letters “Emergency Exit, Keep Clear.” The engine room escape hatch was not labeled on both sides.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 October 2018
Resolved 15 July 2019
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 12 October 2018 Resolved
180.78(a)(5) Child Life Jackets must be stowed separately from adult life jackets. Throughout the vessel, child and adult life jackets were stored together.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 October 2018
Resolved 15 July 2019
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 1 October 2018 Resolved
Vsl’s measured length in FT (Vsl dimension Must be measured in meters), Vsl is broadcasting incomplete dimension information (AIS Antenna Position “X” equals 0) and Vsl is not broadcasting static draft information
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 30 October 2019
Resolution: AIS is operational.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 30 April 2018 Resolved
Vessel must insert electrical blanks in the following breaker panels: operating station & galley.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 May 2018
Resolution: Blanks installed
Engineering › Bilge Water Management System › Strainer
Issued 30 April 2018 Resolved
Vessel must install a proper bilge suction strainer in the following locations: Laz & Void #2.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 May 2018
Resolution: Proper strainers installed.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 30 April 2018 Resolved
Replace all expired first aid kit items.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 May 2018
Resolution: First aid kit items replaced.
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 30 April 2018 Resolved
Replace all plastic trash cans or relocate to ensure a potential fire would be limited to the receptacle.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 May 2018
Resolution: All plastic trashcans replaced with metal.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 30 April 2018 Resolved
Remove compressed gas cylinder from the vessel or provide proper storage.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 May 2018
Resolution: Gas cylinder removed.
Fire Fighting › Combustible Materials › Stowage
Issued 30 April 2018 Resolved
Remove all flammable materials from the vessels "workshop" or provide proper storage container.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 May 2018
Resolution: All flammable materials removed from the vessel.
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 30 April 2018 Resolved
All wiring must be properly fitted in all electrical fixtures in the following locations: Eng rm/Soda rm.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 May 2018
Resolution: All wires properly mounted in their fixtures.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 30 April 2018 Resolved
Properly sanitize all bar areas.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 May 2018
Resolution: All areas properly sanitized.
Construction/Loadline › Penetrations › Gasket
Issued 30 April 2018 Resolved
Replace the watertight gaskets for the following fixtures: Engine Room Door & Bow Hatch.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 May 2018
Resolution: Gaskets replaced.
Fire Fighting › Combustible Materials › Insulation
Issued 30 April 2018 Resolved
Remove and replace all oil soaked lagging on the STBD Generator.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 May 2018
Resolution: All lagging replaced.
Documentation › Logs/Records › Declaration of Inspection
Issued 30 April 2018 Resolved
Have an authorized engine manufacturer's representative evaluate all oil leaking by into the exhaust manifold's of both service generators and provide technicians report to the Coast Guard.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 May 2018
Resolution: Repair report provided. Exhaust manifold gaskets were found to be the cause and we're replaced by JBL engine mechanics.
Documentation › Safety/Response Plans/Programs › Damage Stability Calculation Program/Plans
Issued 4 August 2017 Resolved
Vessel must submit 1.13% lightship change as calculated by LeMole Architecure letter dated August 3, 2017 to the MSC.
Action required: 705 - Other - as specified
Due 18 August 2017
Resolved 17 August 2017
Resolution: Vessel submitted lightship changes to MSC for review.
Documentation › Safety/Response Plans/Programs › Damage Stability Calculation Program/Plans
Issued 4 August 2017 Resolved
Pending results of a stability calculations by MSC, vessel is restricted to 575 pax, 605 total persons on board.
Action required: 705 - Other - as specified
Resolved 5 September 2017
Resolution: MSC determined a 1.13% lightship change not requiring a new stability test. See MSC letter H2-1703356 dated 29AUG2017.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 4 August 2017 Resolved
Vessel must ensure all speakers and light trees are secure while underway.
Action required: 705 - Other - as specified
Due 18 August 2017
Resolved 17 August 2017
Resolution: Vessel secured all speakers and light trees with metal brackets to preventing a hazard to passengers during vessel movement.
Electrical › Lighting (service) › Lighting Fixture
Issued 4 August 2017 Resolved
Vessel must install covers over all engine room lights.
Action required: 705 - Other - as specified
Due 4 September 2017
Resolved 5 September 2017
Resolution: Vessel installed new covers over all lights.
Fire Fighting › Structural - A Class Divisions › Windows
Issued 4 August 2017 Resolved
Vessel must replace broken window, portside, main deck aft.
Action required: 705 - Other - as specified
Due 4 September 2017
Resolved 5 September 2017
Resolution: Vessel replaced broken window.
Electrical › Electric Supply System (service) › Battery Charger
Issued 4 August 2017 Resolved
Vessel must repair or replace battery charger amp meter.
Action required: 705 - Other - as specified
Due 4 September 2017
Resolved 5 September 2017
Resolution: Vessel replaced battery charger amp meter.
Documentation › Safety/Response Plans/Programs › General Arrangement Plans
Issued 4 August 2017 Resolved
Vessel must update/revise and submit for approval the electrical one line diagram w/ load analysis.
Action required: 705 - Other - as specified
Due 4 September 2017
Resolved 5 September 2017
Resolution: Vessel submitted updated electrical one line diagram.
Documentation › Safety/Response Plans/Programs › General Arrangement Plans
Issued 27 July 2017 Resolved
Alterations to the vessel were made without permission to include: new upper deck bar, lighting, wiring, outlets and air conditioning units. Vessel must submit an electrical one line diagram, load analysis and a material list/ spec sheets for work completed. 46CFR115.700
Action required: 705 - Other - as specified
Due 3 August 2017
Resolved 4 August 2017
Resolution: Vessel removed all new wiring, provided material list and weight information for bar and removed a/c unit.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 27 July 2017 Resolved
Vessel's ground detection meter does not work. Vessel must repair or replace and prove proper operation. 46CFR120.200 (b)
Action required: 705 - Other - as specified
Due 4 September 2017
Resolved 5 September 2017
Resolution: Vessel replaced amp meter and proved proper operation.
Electrical › Lighting (service) › Outlet Box
Issued 27 July 2017 Resolved
Vessel must ensure all electrical equipment exposed to the weather is in a watertight and corrosion resistant enclosure. 46CFR120.210 (b & c)
Action required: 705 - Other - as specified
Due 3 August 2017
Resolved 4 August 2017
Resolution: Vessel replaced all enclosures with new watertight/corrosion resistant enclosures.
Documentation › Safety/Response Plans/Programs › General Arrangement Plans
Issued 27 July 2017 Resolved
Due to changes in the vessel's general arrangement, vessel must submit an updated general arrangement drawing. 46CFR115.700 (b)
Action required: 705 - Other - as specified
Due 4 September 2017
Resolved 5 September 2017
Resolution: Vessel submitted a new general arrangement drawing showing new bar on the upper deck.
Operations/Management › Vessel Safety Management › Company Responsibilities/Authority
Issued 27 July 2017 Resolved
Vessel must submit all weight change (additions & subtractions) to the OCMI for review. 46CFR170
Action required: 705 - Other - as specified
Due 3 August 2017
Resolved 4 August 2017
Resolution: Vessel provided revised lightship values to the OCMI for review. A new deficiency will be issued for MSC submission.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 8 July 2016 Resolved
Provide company drug policy and employee assistance program. 46 CFR16.401
Due 9 July 2016
Resolved 5 August 2016
Resolution: Provided proof of company drug policy and employee assistance program to the satisfaction of the attending Coast Guard Marine Inspector.
Engineering › Bilge Water Management System › Not Operational
Issued 24 June 2016 Resolved
Repair High Water Alarm that’s designated for the Forward Peak Hold. The audible portion of the alarm is currently not working.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 June 2016
Resolved 8 July 2016
Resolution: Verified the repairs to the High Water Alarm that’s designated for the Forward Peak Hold. The audible portion of the alarm is currently operational.
Construction/Loadline › Structures › Scuttle
Issued 24 June 2016 Resolved
Replace the missing “opening device (ex. “T” handle) for the engine room emergency escape scuttle. The device must be located on the main deck within close vicinity of the scuttle.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 June 2016
Resolved 8 July 2016
Resolution: Vessel owner replaced the missing “opening device (ex. “T” handle) for the engine room emergency escape scuttle. ALL SAT to the satisfaction of the attending Coast Guard Marine Inspector.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 24 June 2016 Resolved
Repair the emergency lighting located on the 02 Deck in way of the forward portion of the dance floor.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 June 2016
Resolved 8 July 2016
Resolution: Verified repairs to the emergency lighting located on the 02 Deck in way of the forward portion of the dance floor.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 24 June 2016 Resolved
Replace retro-reflective tape on life jackets and forward main deck life ring, as per 46 CFR 185.604
Due 25 June 2016
Resolved 8 July 2016
Resolution: The retro-reflective tape on life jackets and forward main deck life ring have been renewed to the satisfaction of the attending Coast Guard Marine Inspector.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 24 June 2016 Resolved
Ensure annual servicing of portable fire extinguishers is conducted, as per 46 CFR 181.30-1
Due 25 June 2016
Resolved 8 July 2016
Resolution: Verified that the annual servicing of portable fire extinguishers was conducted.
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 24 June 2016 Resolved
Repair the secondary containment located on the exterior of the vessel in way of the starboard mid-section.
Due 25 June 2016
Resolved 8 July 2016
Resolution: Verified repairs to the secondary containment located on the exterior of the vessel in way of the starboard mid-section.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 24 June 2016 Resolved
Ensure all crew members are enrolled and pre-employment testing is conducted as per required DAPI Program (as per 46 CFR 16.201)
Due 25 June 2016
Resolved 8 July 2016
Resolution: Verified that all crew members are enrolled and pre-employment testing was conducted as per required DAPI Program.
Deck/Cargo › Cargo Stowage › General
Issued 24 June 2016 Resolved
Conduct general clean-up and remove and reorganize miscellaneous items in the bar hold.
Due 25 June 2016
Resolved 5 August 2016
Resolution: Verified that general clean-up and remove and reorganization of the miscellaneous items in the bar hold.
Lifesaving › Hand Flares › Quantity
Issued 4 February 2016 Resolved
Vessel was missing three (3) Red hand held flares
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 March 2016
Resolved 5 April 2016
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 4 February 2016 Resolved
Provide Orifginal copy of Certificate of Documentation and maintain onboard vessel
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 March 2016
Resolved 5 April 2016
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 4 February 2016 Resolved
Renew FCC Radio Safety Certificate
Due 4 March 2016
Resolved 5 April 2016
Documentation › Certificates/Documents › FCC SSL
Issued 4 February 2016 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Due 4 March 2016
Resolved 5 April 2016
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 4 February 2016 Resolved
Vessel All around Anchor light inoperable.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 March 2016
Resolved 5 April 2016
Communications › Public Address System › Loudspeaker
Issued 4 February 2016 Resolved
Vessel PA System inoperable. Prove proper operation of PA System.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 March 2016
Resolved 5 April 2016
Communications › Alarms/Indicators › High Water Alarm
Issued 4 February 2016 Resolved
Vessels High Water Alarms in all spaces were inoperable. Prove proper operation of all HW Alarms
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 March 2016
Resolved 5 April 2016
Engineering › Compressed Air System (control) › Compressor
Issued 4 February 2016 Resolved
STBD Side Air Compressor on vessel not operating in a proper working condition.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 March 2016
Resolved 5 April 2016
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 4 February 2016 Resolved
Vessel Structural Fire Protection insulation in Engine room and Muffler room needs to be secured in various locations.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 March 2016
Resolved 5 April 2016
Construction/Loadline › Structures › Scuttle
Issued 4 February 2016 Resolved
Make repairs and prove proper operation of the escape hatch/scuttle in engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 March 2016
Resolved 5 April 2016
Construction/Loadline › Structures › Scuttle
Issued 4 February 2016 Resolved
Make repairs and prove proper operation of the escape hatch/scuttle in muffler room.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 March 2016
Resolved 5 April 2016
Fire Fighting › Means of Escape › Emergency Lighting
Issued 4 February 2016 Resolved
Vessels Emergency lights were inoperable. Prove proper operation of emergency lighting system.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 March 2016
Resolved 5 April 2016
Lifesaving › Lifebuoys › Serviceable
Issued 4 February 2016 Resolved
Add one (01) Ring Lifebouy to make a total of three (3) onboard. One Lifebuoy removed due to cracked serfice.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 March 2016
Resolved 5 April 2016
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 4 February 2016 Resolved
Need to add (01) Floating Lights to Lifebuoy as required.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 March 2016
Resolved 5 April 2016
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 4 February 2016 Resolved
Remove adhesive residue from deck to avoid tripping/slipping hazards.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 March 2016
Resolved 5 April 2016
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 4 February 2016 Resolved
Add and secure High Temp lagging/insulation on Port and Starboard Engines and generators in areas missing or not secured.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 March 2016
Resolved 5 April 2016
Engineering › Diesel Engine (propulsion-direct drive) › Pump, High Pressure (fuel injection)
Issued 4 February 2016 Resolved
Provide chaffing gear on Stbd engine fuel pump line to avoid chaffing of line on engine.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 March 2016
Resolved 5 April 2016
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 4 February 2016 Resolved
Prior to recovering 1st deck floor covering, provide material specifications to the cognizant OCMI to ensure correct fire rating.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 July 2016
Resolution: Provided material specifications to the cognizant OCMI as to the correct fire rating.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 19 May 2014 Resolved
Re-label PFD numbering on boxes on upper deck.
Action required: 705 - Other - as specified
Due 30 June 2014
Resolved 22 July 2014
Resolution: PFD boxes correctly labeled.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 19 May 2014 Resolved
Provide halyard clip on ring buoy IWO front ramp.
Action required: 705 - Other - as specified
Due 30 June 2014
Resolved 22 July 2014
Resolution: Halyard replaced.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 19 May 2014 Resolved
Install new batteries in bridge flashlight.
Action required: 705 - Other - as specified
Due 30 June 2014
Resolved 22 July 2014
Resolution: Batteries replaced flashlights work.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 19 May 2014 Resolved
Update Coast Pilot and Light list
Action required: 705 - Other - as specified
Due 30 June 2014
Resolved 22 July 2014
Resolution: New Coast Pilot and Light list were on board.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 19 May 2014 Resolved
General housekeeping in Pilot house.
Action required: 705 - Other - as specified
Due 30 June 2014
Resolved 22 July 2014
Resolution: Pilot house was squared away.
Communications › Alarms/Indicators › Bilge Alarm
Issued 19 May 2014 Resolved
Replace high water indicator for hold #5 (and replace #6)
Action required: 705 - Other - as specified
Due 30 June 2014
Resolved 24 July 2014
Resolution: Vsl purchased and installed bilge high level alarm and is operable.
Operations/Management › Drills/Instruction › Fire
Issued 19 May 2014 Resolved
Start log for required safety and fire gear checks.
Action required: 705 - Other - as specified
Due 30 June 2014
Resolved 22 July 2014
Resolution: Log for safety and fire gear checks was established.
Deck/Cargo › Mooring/Anchoring › Mooring Line/Hawser
Issued 19 May 2014 Resolved
Replace worn mooring line.
Action required: 705 - Other - as specified
Due 30 June 2014
Resolved 22 July 2014
Resolution: Mooring lines were replaced.
Communications › Visual Communication › Signalling Lamp
Issued 19 May 2014 Resolved
Prove operation of WTD ligth.
Action required: 705 - Other - as specified
Due 30 June 2014
Resolved 22 July 2014
Resolution: WTD light is operational.
Fire Fighting › Combustible Materials › Furniture/Furnishings
Issued 19 May 2014 Resolved
Provide certs for new carpet.
Action required: 705 - Other - as specified
Due 31 August 2014
Resolved 27 March 2017
Resolution: Def cleared
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 19 May 2014 Resolved
Re-label lifejacket storage lockers to reflect accurate count.
Action required: 705 - Other - as specified
Due 30 June 2014
Resolved 22 July 2014
Resolution: PFD storage lockers were correctly labeled.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 19 May 2014 Resolved
Prover proper segregation of child-sized life preservers in lower deck locker.
Action required: 705 - Other - as specified
Due 30 June 2014
Resolved 22 July 2014
Resolution: Child PFDs were separate from Adult PFDs
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 19 May 2014 Resolved
Replace retro-reflective tape on life jackets as needed.
Action required: 705 - Other - as specified
Due 30 June 2014
Resolved 22 July 2014
Resolution: Retro tape was replaced as needed.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 19 May 2014 Resolved
Dispose of or replace discolored life jackets.
Action required: 705 - Other - as specified
Due 30 June 2014
Resolved 22 July 2014
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 19 May 2014 Resolved
Remove empty first aid kit from bulkhead in scullery
Action required: 705 - Other - as specified
Due 30 June 2014
Resolved 22 July 2014
Resolution: Empty first aid kit was removed.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 19 May 2014 Resolved
Properly secure mini fridge and microwave in galley.
Action required: 705 - Other - as specified
Due 30 June 2014
Resolved 22 July 2014
Resolution: Fridge and microwave were removed.
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 19 May 2014 Resolved
Dispose of all open food and beverage containers.
Action required: 705 - Other - as specified
Due 30 June 2014
Resolved 22 July 2014
Resolution: Trash was removed.
Electrical › Electric Supply System (service) › Cable
Issued 19 May 2014 Resolved
Properly splice electrical wiring in scullery overhead.
Action required: 705 - Other - as specified
Due 30 June 2014
Resolved 22 July 2014
Resolution: Wiring enclosed in J-box.
Electrical › Electric Supply System (service) › Cable
Issued 19 May 2014 Resolved
Properly dead-end wiring in scullery overhead and first deck aft passenger cabin and womens first deck head closet.
Action required: 705 - Other - as specified
Due 30 June 2014
Resolved 22 July 2014
Resolution: Wiring enclosed in J-box.
Electrical › Electric Supply System (service) › Cable
Issued 19 May 2014 Resolved
Hard wire accent (twinkle) lighting on main lower deck.
Action required: 705 - Other - as specified
Due 30 June 2014
Resolved 22 July 2014
Resolution: Wiring corrected.
Engineering › Freshwater Generation System › Piping
Issued 19 May 2014 Resolved
Provide guard for PWT sight glass.
Action required: 705 - Other - as specified
Due 31 August 2014
Resolved 27 March 2017
Resolution: Def cleared
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 19 May 2014 Resolved
Install approved SFP tape, in engine room, as need, i.e. above port generator.
Action required: 705 - Other - as specified
Due 30 June 2014
Resolved 22 July 2014
Resolution: Tape installed.
Engineering › Diesel Engine (propulsion-direct drive) › Exhaust Manifold
Issued 19 May 2014 Resolved
Install insulation on port maind diesel engine muffler.
Action required: 705 - Other - as specified
Due 31 August 2014
Resolved 27 March 2017
Resolution: Def cleared
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 19 May 2014 Resolved
Provide copy of valid COD
Action required: 705 - Other - as specified
Due 30 June 2014
Resolved 22 July 2014
Resolution: Original COD on board.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 19 May 2014 Resolved
Provide updated list of employee enrollment inf DAPI program.
Action required: 705 - Other - as specified
Due 31 August 2014
Resolved 27 March 2017
Resolution: Def cleared
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 19 May 2014 Resolved
Schedule DAPI audit.
Action required: 705 - Other - as specified
Due 30 June 2014
Resolved 22 July 2014
Resolution: DAPI audit completed.
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 1 May 2014 Resolved
Install new 150 psi pressure relief valve (02) on start air tanks.
Action required: 705 - Other - as specified
Due 21 May 2014
Resolved 19 May 2014
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 1 May 2014 Resolved
Install SFP above port generator
Action required: 705 - Other - as specified
Due 21 May 2014
Resolved 19 May 2014
Stability › Watertight Integrity › Weathertight Enclosure
Issued 1 May 2014 Resolved
Renew forepeak hatch next drydock
Action required: 705 - Other - as specified
Due 30 April 2015
Resolved 2 March 2017
Resolution: Def cleared
Accommodation/Occupational Safety › Potable Water System › General
Issued 1 December 2010 Resolved
Prove operation of valve in fwd. water tank.
Due 26 May 2011
Resolved 23 June 2011
Resolution: New ball valve installed.
Operations/Management › Navigation Safety › Requirements for Vessels at Anchor
Issued 1 December 2010 Resolved
Route anchor line for proper operation.
Due 26 May 2011
Resolved 23 June 2011
Resolution: Anchor line is properly arranged.
Personnel › Training › Crisis Management/Human Behaviour
Issued 27 May 2008 Resolved
COMPLETE MTSA VERIFICATION WITH CSO AND VSO PRESENT FOR DRILLS
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 July 2008
Resolved 17 June 2008
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 27 May 2008 Resolved
REMOVE ALL PAINT FROM VESSEL
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 June 2008
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 27 May 2008 Resolved
REMOVE ACETYLENE BOTTLE FROM VESSEL
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 May 2008
Resolution: CLEARED
Stability › Weathertight Integrity › General
Issued 27 May 2008 Resolved
MAKE PERMANENT REPAIRS TO DOOR SEALS 01 DECK FWD
Action required: 705 - Other - as specified
Due 10 June 2008
Resolved 17 June 2008
Fire Fighting › Means of Escape › Emergency Lighting
Issued 27 May 2008 Resolved
MAKE PERMANENT REPAIRS TO THE EMERGENCY LIGHTING IN THE ENGINE ROOM
Action required: 705 - Other - as specified
Due 10 June 2008
Resolved 27 May 2008
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 27 May 2008 Resolved
REMOVE DEAD END WIRING IN BOTH THE GALLEY AND THE STERN AREA
Action required: 705 - Other - as specified
Resolved 17 June 2008
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 27 May 2008 Resolved
INSTALL LIGHT COVERS MAIN DECK
Action required: 705 - Other - as specified
Due 10 June 2008
Resolved 27 May 2008
Resolution: CLEARED
Fire Fighting › Means of Escape › Escape Route Signs
Issued 27 May 2008 Resolved
RE-PAINT ALL EMERGENCY ESCAPE HATCHES.
Action required: 705 - Other - as specified
Due 10 June 2008
Resolved 17 June 2008
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 27 May 2008 Resolved
PROVIDE SPECIFICATION SHEETS FOR NEWLY INSTALLED CARPET
Action required: 705 - Other - as specified
Due 10 June 2008
Resolved 17 June 2008
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 27 May 2008 Resolved
PROPERLY SECURE FWD GATE - MAIN DECK.
Action required: 705 - Other - as specified
Due 10 June 2008
Resolved 17 June 2008
Stability › Weathertight Integrity › General
Issued 27 May 2008 Resolved
REPAIR WINDOW SEALS MAIN DECK - STBD.
Action required: 705 - Other - as specified
Resolved 17 June 2008
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 27 May 2008 Resolved
CAP PORT SEWAGE PIPE MAIN DECK.
Action required: 705 - Other - as specified
Due 10 June 2008
Resolved 17 June 2008
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 27 May 2008 Resolved
INSTALL LIGHT GLOBE CAGES - 02 DECK.
Action required: 705 - Other - as specified
Due 10 June 2008
Resolved 17 June 2008
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 27 May 2008 Resolved
INSTALL LIGHT GLOBE MAIN DECK - FREEZER.
Action required: 705 - Other - as specified
Due 10 June 2008
Resolved 17 June 2008
Engineering › Bilge Water Management System › Not Installed
Issued 27 May 2008 Resolved
REPAIR HIGH LEVEL BILGE ALARM LIGHT - FORPEAK
Action required: 705 - Other - as specified
Due 10 June 2008
Resolved 17 June 2008
Engineering › Bilge Water Management System › Piping
Issued 27 May 2008 Resolved
DEMONSTRATE PROPER OPERATION OF THE BILGE SYSTEM PRIOR TO JUNE 10, 2008
Action required: 705 - Other - as specified
Due 10 June 2008
Resolved 17 June 2008
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 9 March 2007 Resolved
Provide 31 Type I Adult lifejackets to reflect new total passenger amount as a result of the deck rail criteria.
Action required: 705 - Other - as specified
Resolved 13 April 2010
Lifesaving › Lifebuoys › Serviceable
Issued 29 January 2007 Resolved
Replace 02 wasted ring buoys
Action required: 705 - Other - as specified
Resolved 12 February 2007
Communications › Radio Communications › VHF Radiotelephone
Issued 29 January 2007 Resolved
Provide evidence of a current FCC Safety Radio Telephony Certificate.
Action required: 705 - Other - as specified
Resolved 12 February 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 29 January 2007 Resolved
Remove all dead end wiring from vessel
Action required: 705 - Other - as specified
Resolved 12 February 2007
Engineering › Bilge Water Management System › Not Operational
Issued 29 January 2007 Resolved
Make permanent repairs to the forpeak high level alarm indicator and identify all alarms on the console.
Action required: 705 - Other - as specified
Resolved 12 February 2007
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 29 January 2007 Resolved
Replace missing light cover 2nd deck STBD side
Action required: 705 - Other - as specified
Resolved 12 February 2007
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 29 January 2007 Resolved
Replace machinery guards for #1 generator.
Action required: 705 - Other - as specified
Resolved 12 February 2007
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 29 January 2007 Resolved
Seal all blanks in switchboard panel
Action required: 705 - Other - as specified
Resolved 12 February 2007
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 29 January 2007 Resolved
Rewire soup kettle
Action required: 705 - Other - as specified
Resolved 12 February 2007
Fire Fighting › Means of Escape › Emergency Lighting
Issued 29 January 2007 Resolved
Repair emergency light in the galley
Action required: 705 - Other - as specified
Resolved 12 February 2007
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 29 January 2007 Resolved
Remove all unused paint from the vessel
Action required: 705 - Other - as specified
Resolved 9 March 2007
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 29 January 2007 Resolved
Preform all emergency drills in the presence of a USCG marine inspector.
Action required: 705 - Other - as specified
Resolved 9 March 2007
Engineering › Diesel Engine (propulsion-direct drive) › Gear/Clutch Starter (electric)
Issued 29 January 2007 Resolved
Make permanent repiars to the STBD starter.
Action required: 705 - Other - as specified
Resolved 12 February 2007
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 29 January 2007 Resolved
Replace 121 adult type I lifejackets. Passenger count reduced until all jackets are onboard.
Action required: 705 - Other - as specified
Resolved 12 February 2007
Construction/Loadline › Hull › Weld
Issued 22 February 2006 Resolved
Found a broken paddle on cosmetic paddle wheel assembly and various paddles were missing bolts. O/O to provide proof of a proper repair and replacement of missing bolts.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 March 2006
Resolution: Paddle wheel support bracket was re-welded and re-bolted.
Engineering › Bilge Water Management System › Piping
Issued 22 February 2006 Resolved
Stuffing tube through watertight bulkhead needs to be repacked.
Action required: 705 - Other - as specified
Due 2 March 2006
Resolved 3 March 2006
Resolution: Stuffing tube was repacked.
Engineering › Diesel Engine (propulsion-reduction gear) › Cylinder Head
Issued 25 January 2006 Resolved
Vessel suffered an port engine casualty while transiting to dry-dock.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 January 2007
Engineering › Diesel Engine (propulsion-direct drive)
Issued 17 February 2004 Resolved
Provide lagging on port MDE exhaust. LEGACY COMPONENT DESC: Piping (exhaust)
Due 17 March 2004
Resolved 17 March 2004
Lifesaving › Lifejacket/PFD (General)
Issued 17 February 2004 Resolved
Provide stowage for PFDs. LEGACY COMPONENT DESC: Storage
Due 17 March 2004
Resolved 17 March 2004
Documentation › Certificates/Documents
Issued 17 February 2004 Resolved
Post all pages of COI and stability letter. LEGACY COMPONENT DESC: Certificate of Inspection
Due 17 March 2004
Resolved 17 March 2004
Engineering › Shafting/Propeller Arrangements
Issued 17 February 2004 Resolved
Tighten shaft packing. LEGACY COMPONENT DESC: Propeller Shaft
Due 17 March 2004
Resolved 17 March 2004
Engineering
Issued 17 February 2004 Resolved
Label emergency escape scuttles.
Due 17 March 2004
Resolved 17 March 2004
Engineering › Shafting/Propeller Arrangements
Issued 18 August 2003 Resolved
Dry-dock vessel prior to carrying passengers to evaluate the vessel's shafts and propellers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 September 2003
Resolved 18 September 2003
Construction/Loadline › Structures
Issued 6 March 2002 Resolved
provide closure for 01 deck door stbd side.
Due 6 April 2002
Resolved 12 February 2003
Construction/Loadline › Hull
Issued 22 January 2002 Resolved
Crop and renew fractured areas in way of shell plate aft. LEGACY COMPONENT DESC: Hull Plating
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 30 January 2002
Stability › Watertight Integrity
Issued 22 January 2002 Resolved
Replace/renew manhole cover gasket and bolt on forecastle hatch - make hatch opeartional.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 30 January 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 22 January 2002 Resolved
Clean excess oil from engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 30 January 2002
Engineering › Bilge Water Management System
Issued 22 January 2002 Resolved
Replace foot strainer for bilge suction pickup in potable water hold. LEGACY COMPONENT DESC: Strainer
Action required: 705 - Other - as specified
Resolved 30 January 2002
Engineering › Shafting/Propeller Arrangements
Issued 22 January 2002 Resolved
Use a proper cotter pin and locking nuts on port propeller.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 30 January 2002
Engineering › Generator (propulsion-electric)
Issued 22 January 2002 Resolved
Repair/replace as originial exhaust system to starboard side Ship Service Generator.
Action required: 705 - Other - as specified
Resolved 30 January 2002
Construction/Loadline
Issued 21 March 2001 Resolved
LIGHTS FOR ALARMS ON BILGE HIGH LEVEL ALARM PANEL INOP.
Condition: Unknown
Due 21 March 2001
Resolved 12 April 2001
Electrical
Issued 11 March 1999 Resolved
REMOUNT CONTROLLER FOR POTABLE WATER PUMP IN FWD HOLD.
Condition: Unknown
Due 11 April 1999
Resolved 20 April 1999
Construction/Loadline
Issued 11 March 1999 Resolved
PROVIDE WRITTEN REPAIR PROPOSAL FOR HAIRLINE CRACKS IN HULL IN LAZERETTE.
Condition: Unknown
Due 11 April 1999
Resolved 20 April 1999
Construction/Loadline
Issued 11 March 1999 Resolved
RELOCATE ENGINE ROOM AND FWD HOLD BILGE ALARM JUNCTION BOXES TO A POINT ABOVE HIGH LEVEL SENSOR.
Condition: Unknown
Due 11 April 1999
Resolved 20 April 1999
Electrical
Issued 6 August 1998 Resolved
PRIOR TO CARRYING PASSENGERS PROVE PROPER OPERATION OF THE GENERATOR SET UNDER A LOAD IN THE PRESENCE OF A MARINE INSPECTOR.
Condition: Unknown
Due 6 August 1998
Resolved 12 August 1998
Electrical
Issued 6 August 1998 Resolved
PRIOR TO CARRYING PASSENGERS MEGGER ALL CONTROL AND LOAD WIRES ON BOTH PORTAND STBD SWITCHBOARDS.
Condition: Unknown
Due 6 August 1998
Resolved 12 August 1998
Electrical
Issued 6 August 1998 Resolved
PRIOR TO CARRYING PASSENGERS CONDUCT A RUNNING LOAD TEST FOR A MINIMUM OF TWO HOURS.
Condition: Unknown
Due 6 August 1998
Resolved 12 August 1998
Electrical
Issued 6 August 1998 Resolved
PRIOR TO CARRYING PASSENGERS PROVE PROPER OPERATION OF THE 120/208 SYSTEM ON THE PORT AND STARBOARD GENERATOR SETS.
Condition: Unknown
Due 6 August 1998
Resolved 12 August 1998
Electrical
Issued 6 August 1998 Resolved
PRIOR TO CARRYING PASSENGERS WIPE AND CLEAN BOTH GENERATOR EXCITER FIELDS.
Condition: Unknown
Due 6 August 1998
Resolved 12 August 1998
Construction/Loadline
Issued 19 March 1998 Resolved
INSTALL MISSING FOREPEAK BILGE SUCTION VALVE WITH REACH ROD.
Condition: Unknown
Due 19 March 1998
Resolved 19 March 1998
Fire Fighting
Issued 19 March 1998 Resolved
PROVIDE PROPER BRACKET FOR ENGINE ROOM C02 FIRE EXTINGUISHER._x001C_
Condition: Unknown
Due 19 March 1998
Resolved 19 March 1998
Lifesaving
Issued 19 March 1998 Resolved
PRIOR TO CARRYING PASSENGERS, PROVIDE PROOF OF ENROLLMENT IN CG CERTIFIED DRUG TESTING PROGRAM/CONSORTIUM.
Condition: Unknown
Due 19 April 1998
Resolved 25 March 1998
Engineering
Issued 19 March 1998 Resolved
REPLACE DETERIORATED START AIR HOSE ON S/S GENERATOR.
Condition: Unknown
Due 19 March 1998
Resolved 19 March 1998
Lifesaving
Issued 19 March 1998 Resolved
REPAIR P.A. SYSTEM SPEAKER ON 02 DECK BEHIND PILOT HOUSE.
Condition: Unknown
Due 19 March 1998
Resolved 19 March 1998
Construction/Loadline
Issued 19 March 1998 Resolved
PROVE PROPER OPERATION OF ENGINE ROOM WTD "OPEN/CLOSE" VISUAL INDICATOR LIGHT.
Condition: Unknown
Due 19 March 1998
Resolved 19 March 1998
Lifesaving
Issued 19 March 1998 Resolved
PROPERLY SEPERATE AND STOW CHILD PFD'S FROM ADULT PFD'S IN 02 DECK AFT LIFEJACKET STOWAGE.
Condition: Unknown
Due 19 March 1998
Resolved 19 March 1998
Construction/Loadline
Issued 19 March 1998 Resolved
ADJUST WATERTIGHT DOOR TO ENGINE ROOM.
Condition: Unknown
Due 19 March 1998
Resolved 19 March 1998
Electrical
Issued 19 March 1998 Resolved
INSTALL APPROVED ELECTRICAL OUTLETS FOR CARBONATING PUMPS.
Condition: Unknown
Due 19 March 1998
Resolved 19 March 1998
Navigation
Issued 19 March 1998 Resolved
REPAIR PILOT HOUSE RUDDER ANGLE INDICATOR.
Condition: Unknown
Due 19 March 1998
Resolved 19 March 1998
Fire Fighting
Issued 19 March 1998 Resolved
PROVIDE PROPER SPANNER WRENCHES AND APPROVED LINED FIRE HOSES AT EACH HOSE STATION.
Condition: Unknown
Due 19 March 1998
Resolved 19 March 1998
Fire Fighting
Issued 19 March 1998 Resolved
PROVIDE FOUR(4) APPROVED FIRE HOSE NOZZLES IAW 46 CFR 181.15-10.
Condition: Unknown
Due 19 March 1998
Resolved 19 March 1998
Electrical
Issued 19 March 1998 Resolved
REMOVE "DEAD END" WIRING ABOVE MAIN DECK STAGE AREA.
Condition: Unknown
Due 19 March 1998
Resolved 19 March 1998
Accommodation/Occupational Safety
Issued 5 March 1997 Resolved
REPAIR LEAK IN HOT WATER HEATER. LOCATED MAIN DECK FWD VOID
Condition: Unknown
Due 5 March 1997
Resolved 5 March 1997
Documentation
Issued 5 March 1997 Resolved
OBTAIN FCC OPERATOR LICENSE.
Condition: Unknown
Due 5 March 1997
Resolved 5 March 1997
Electrical
Issued 5 March 1997 Resolved
PERMANENTLY ELECTRICALLY WIRE STRING LIGHTS AND TWO GALLEY REFFER UNITS IN MAIN GALLEY.
Condition: Unknown
Due 5 March 1997
Resolved 5 March 1997
Fire Fighting
Issued 5 March 1997 Resolved
MOUNT ENGINE ROOM 15LB CO2 IN BRACKET.
Condition: Unknown
Due 5 March 1997
Resolved 5 March 1997
Electrical
Issued 5 March 1997 Resolved
PROPERLY SECURE OR REMOVE DEAD END WIRING IN PILOTHOUSE AND THROUGHOUT VESSEL.
Condition: Unknown
Due 5 March 1997
Resolved 5 March 1997
Lifesaving
Issued 5 March 1997 Resolved
CORRECT PUBLIC ADDRESS SPEAKER LOCATIONS.
Condition: Unknown
Due 5 March 1997
Resolved 5 March 1997
Lifesaving
Issued 5 March 1997 Resolved
OBTAIN REQUIRED FIRST AID KIT, IAW 46 CFR 121.710
Condition: Unknown
Due 5 March 1997
Resolved 5 March 1997
Navigation
Issued 5 March 1997 Resolved
OBTAIN PROPER NAVIGATION PUBLICATIONS IAW 121.610
Condition: Unknown
Due 5 March 1997
Resolved 5 March 1997
Engineering
Issued 5 March 1997 Resolved
REPAIR FUEL OIL LEAKS IN ENGINE ROOM SUCTION PIPING.
Condition: Unknown
Due 5 March 1997
Resolved 5 March 1997
Electrical
Issued 5 March 1997 Resolved
INSTALL BLANKS IN OPEN BREAKER CUTOUTS IN MAIN SWITCHBOARD.
Condition: Unknown
Due 5 March 1997
Resolved 5 March 1997
Engineering
Issued 5 March 1997 Resolved
INSTALL DOUBLE CLAMPS ON RUBBER HOSES NOT HAVING ASSEMBLED HOSE CONNECTIONS
Condition: Unknown
Due 5 March 1997
Resolved 5 March 1997
Construction/Loadline
Issued 15 March 1995 Resolved
1. REPLACE GASKET IN WATERTIGHT DOOR TO ENGINEROOM.
Condition: Unknown
Due 15 March 1995
Resolved 15 March 1995
Engineering
Issued 15 March 1995 Resolved
CORRECT IMPROPER WIRE SPLICES ON PORT AND STARBOARD MAIN ENGINES OIL SENSORS.
Condition: Unknown
Due 15 March 1995
Resolved 15 March 1995
Lifesaving
Issued 15 March 1995 Resolved
REPLACE GRAB LINE ON WHEELHOUSE LIFERING.
Condition: Unknown
Due 15 March 1995
Resolved 15 March 1995
Engineering
Issued 15 March 1995 Resolved
REPLACE INSULATION ON PORT AND STARBOARD MAIN EXHAUST PIPES WHERE EXPOSED.
Condition: Unknown
Due 15 March 1995
Resolved 15 March 1995
Lifesaving
Issued 15 March 1995 Resolved
REMOVE BOUYANT APPARATUS FROM VESSEL.
Condition: Unknown
Due 15 March 1995
Resolved 15 March 1995
Electrical
Issued 15 March 1994 Resolved
MOUNT MEAT SLICER TO GALLEY BULKHEAD.
Condition: Unknown
Due 15 March 1994
Resolved 15 March 1994
Electrical
Issued 15 March 1994 Resolved
REPLACE ELECTRICAL CORD ATTACHED TO MEAT SLICER.
Condition: Unknown
Due 15 March 1994
Resolved 15 March 1994
Unknown
Issued 15 March 1994 Resolved
REMOVE ALL PAINT, VARANISH AND SPRAY CANS FROM AFTER MACHINERY SPACE.
Condition: Unknown
Due 15 March 1994
Resolved 15 March 1994
Documentation
Issued 15 March 1994 Resolved
PROVIDE OCMI WITH A COPY OF CURRENT FCC SAFETY CERTIFICATE.
Condition: Unknown
Due 15 March 1994
Resolved 15 March 1994
Electrical
Issued 15 March 1994 Resolved
DOUBLE NUT ALL BATTERY TERMINAL LUGS.
Condition: Unknown
Due 15 March 1994
Resolved 15 March 1994
Electrical
Issued 15 March 1994 Resolved
PROVIDE OCMI WITH COPIES OF APPROVED AND UPDATED ELECTRICAL DRAWINGS.
Condition: Unknown
Due 15 March 1994
Resolved 15 March 1994
Lifesaving
Issued 16 March 1993 Resolved
PROVIDE 2 LIFERINGS WITH PROPER GRABLINES AND STENCILING._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 April 1993
Resolved 29 April 1993
Navigation
Issued 16 March 1993 Resolved
PROVE PROPER OPERATION OF FATHOMETER_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 April 1993
Resolved 29 April 1993
Engineering
Issued 16 March 1993 Resolved
REPLACE FLAME SCREENS IN VENTILATION FOR VOIDS AND FUEL TANKS WITH 30X30 WIRE MESH._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 April 1993
Resolved 29 April 1993
Accommodation/Occupational Safety
Issued 20 November 1992 Resolved
PROVIDE A MEANS TO KEEP GALLEY WASH DOWN WATER FROM ENTERING THE VOID SPACES BELOW.
Condition: Unknown
Due 20 November 1992
Resolved 20 November 1992
Accommodation/Occupational Safety
Issued 19 March 1992 Resolved
REMOVE LOCK FROM GALLEY DOOR AND REPLACE WITH LATCH OPERATED MECHANISM.
Condition: Unknown
Due 19 March 1992
Resolved 19 March 1992
Construction/Loadline
Issued 19 March 1992 Resolved
BULKHEAD ON MAIN DECK FORWARD OF GALLEY IS TO BE REMOVED.
Condition: Unknown
Due 19 March 1992
Resolved 19 March 1992
Engineering
Issued 19 March 1992 Resolved
IAW WITH 46 CFR 176.25-30 OPEN THE STBD PRESSURE VSL AND MAKE AVAILABLE FORINTERNAL INSPECTION.
Condition: Unknown
Due 19 March 1992
Resolved 19 March 1992
Fire Fighting
Issued 19 March 1992 Resolved
THE INTERIOR STRUCTURE DOOR IN THE A-60 BULKHEAD BETWEEN THE MAIN AND SECOND DECKS REQUIRES A LATCHING MECHANISM TO KEEP IT SHUT.
Condition: Unknown
Due 19 March 1992
Resolved 19 March 1992
Electrical
Issued 29 November 1991 Resolved
INSTALL MACHINERY GUARD ON PORT SIDE SHIP SERVICE GENERATOR WHEEL BALANCER._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 29 November 1991
Resolved 29 November 1991
Engineering
Issued 29 November 1991 Resolved
PROVIDE DOCUMENTATION THAT THE WELDER UTILIZED TO MAKE REPAIRS TO CRACK IN STBD MUFFLER EXHAUST PIPE WAS QUALIFIED._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 5 December 1991
Resolved 5 December 1991
Engineering
Issued 29 November 1991 Resolved
PROVIDE SATISFACTORY EVIDENCE OF HAVING CONDUCTED A DYE PENETRANT TEST OF THE STARBOARD MAIN ENGINE EXHAUST MUFFLER AT INTERFACE OF MUFFLER BODY AND OUTLET PIPE.
Condition: Unknown
Due 29 November 1991
Resolved 29 November 1991
Engineering
Issued 29 November 1991 Resolved
PROVIDE SUPPORT BRACKETS FOR PORT AND STARBOARD MAIN ENGINE EXHAUST MUFFLERS.
Condition: Unknown
Due 29 November 1991
Resolved 29 November 1991
Fire Fighting
Issued 20 March 1991 Resolved
REPLACE OIL SOAKED INSULATION ON BULKHEADS AND UNDER MAIN DECK IN STARBOARDAFT CORNER OF ENGINEROOM.
Condition: Unknown
Due 20 March 1991
Resolved 20 March 1991
Accommodation/Occupational Safety
Issued 20 March 1991 Resolved
CORRECT VENTILATION OF DIESEL ENGINE COMPARTMENT TO MEET THE REQUIREMENTS OF 46 CFR 182.20-45(C),(D) AND (E).
Condition: Unknown
Due 20 March 1991
Resolved 20 March 1991
Accommodation/Occupational Safety
Issued 20 March 1991 Resolved
CLEAN ENGINEROOM VENTILATION FAN AND COWLING OF OILY RESIDUE.
Condition: Unknown
Due 20 March 1991
Resolved 20 March 1991
Engineering
Issued 20 March 1991 Resolved
DOUBLE HOSE CLAMP ALL HYDRAULIC HOSES ON ENGINE CLUTCH RAMS.
Condition: Unknown
Due 20 March 1991
Resolved 20 March 1991
Engineering
Issued 20 March 1991 Resolved
RENEW KEEL COOLER JABSCO PUMP GASKET AND PROVE OPERATION.
Condition: Unknown
Due 20 March 1991
Resolved 20 March 1991
Engineering
Issued 20 March 1991 Resolved
PROVE OPERATIONAL PRIMARY BILGE PUMP.
Condition: Unknown
Due 20 March 1991
Resolved 20 March 1991
Engineering
Issued 20 March 1991 Resolved
REPLACE WASTED HOSES ON PORT DIESEL ENGINE.
Condition: Unknown
Due 20 March 1991
Resolved 20 March 1991
Engineering
Issued 20 March 1991 Resolved
PROVIDE ONE PORTABLE GAS OPERATED AT LEAST 50 GPM PUMP UNTIL THE PRIMARY BILGE PUMP IS PROVED OPERATIONAL.
Condition: Unknown
Due 20 March 1991
Resolved 20 March 1991
Electrical
Issued 20 March 1991 Resolved
PROVE SATISFACTORY LOW LUBE OIL TRIP AND ALARM ON SHIP SERVICE GENERATORS.
Condition: Unknown
Due 20 March 1991
Resolved 20 March 1991
Unknown
Issued 11 May 1990 Resolved
PROVE PROPER OPERATION OF ALL TRIP'S AND ALARMS REQUIRED FOR MAIN DIESEL ENGINES AND PRIME MOVERS FOR GENERATORS
Condition: Unknown
Due 11 May 1990
Resolved 11 May 1990
Accommodation/Occupational Safety
Issued 11 May 1990 Resolved
OPEN ALL PRESSURE VESSELS FOR INTERNAL INSPECTION
Condition: Unknown
Due 11 May 1990
Resolved 11 May 1990
Lifesaving
Issued 11 May 1990 Resolved
REPAIR CRACKED OUTER COVERS OF ALL BUOYANT APPARATUS IN ACCORDANCE WITH MANUFACTURER'S SPECS
Condition: Unknown
Due 11 May 1990
Resolved 11 May 1990
Lifesaving
Issued 11 April 1989 Resolved
PROVIDE SUFFICIENT FLOAT-FREE LINK CAPACITY FOR EACH BOUYANT APPARATUS.
Condition: Unknown
Due 11 April 1989
Resolved 11 April 1989
Lifesaving
Issued 11 April 1989 Resolved
STENCIL CAPACITY OF BOUYANT APPARATUS ON EACH APPARATUS.
Condition: Unknown
Due 11 April 1989
Resolved 11 April 1989
Lifesaving
Issued 11 April 1989 Resolved
STENCIL ALL LIFE LACKET BOXES AND LOCKERS WITH THE ACTUAL NUMBER OF JACKETSCONTAINED.
Condition: Unknown
Due 11 April 1989
Resolved 11 April 1989
Fire Fighting
Issued 11 April 1989 Resolved
RE-STINCIL FIRE AXE.
Condition: Unknown
Due 11 April 1989
Resolved 11 April 1989
Fire Fighting
Issued 11 April 1989 Resolved
PROPERLY STENCIL ALL FIRE STATIONS INSIDE VESSEL.
Condition: Unknown
Due 11 April 1989
Resolved 11 April 1989
Electrical
Issued 11 April 1989 Resolved
REPLACE BATTERIES AND MAKE OPERABLE ALL FIVE EMERGENCY LIGHTS AND DEMONSTRATE.
Condition: Unknown
Due 11 April 1989
Resolved 11 April 1989
Accommodation/Occupational Safety
Issued 11 April 1989 Resolved
CLEAN OUT BILGE UNDER GALLEY AND LAZZERETTE.
Condition: Unknown
Due 11 April 1989
Resolved 11 April 1989
Electrical
Issued 11 April 1989 Resolved
DEMONSTRATE GENERATOR CUT OFFS, ALARMS AND OVER SPEED TRIPS ON BOTH GENERATORS. THIS IS TO BE COMPLETED BY AN ENGINEER FAMILIAR WITH THE ENGINES.
Condition: Unknown
Due 11 April 1989
Resolved 11 April 1989
Construction/Loadline
Issued 11 April 1989 Resolved
MAKE THE BRIDGE ALARM FOR THE ENGINE ROOM WATER TIGHT DOOR OPERABLE.
Condition: Unknown
Due 11 April 1989
Resolved 11 April 1989
Lifesaving
Issued 11 April 1989 Resolved
STENCIL ONE RING BUOY WITH NAME OF VESSEL.
Condition: Unknown
Due 11 April 1989
Resolved 11 April 1989
Lifesaving
Issued 11 April 1989 Resolved
PROVIDE 60' PAINTER ON 1 RING BUOY AND REPLACE FLOAT LIGHT.
Condition: Unknown
Due 11 April 1989
Resolved 11 April 1989
Navigation
Issued 11 April 1989 Resolved
OBTAIN CURRENT RADIO TELEPHONY CERTIFICATE FROM FCC.
Condition: Unknown
Due 11 April 1989
Resolved 11 April 1989
Lifesaving
Issued 25 August 1988 Resolved
PROVIDE MEANS TO MAKE ALL LIFE PRESERVERS STOWED IN LOCKERS ON UPPER DECK COMPLETELY ACCESSIBLE.
Condition: Unknown
Due 25 August 1988
Resolved 25 August 1988
Lifesaving
Issued 25 August 1988 Resolved
PROPERLY MARK QUANTITY OF ADULT AND CHILD LIFE PRESERVERS STOWED IN LOCKERSON UPPER DECK.
Condition: Unknown
Due 25 August 1988
Resolved 25 August 1988
Lifesaving
Issued 25 August 1988 Resolved
PROVIDE SEPARATE STOWAGE FOR AND LABEL LIFE PRESERVERS STOWED IN FWD LOCKERLOWER DECK.
Condition: Unknown
Due 25 August 1988
Resolved 25 August 1988
Electrical
Issued 1 July 1988 Resolved
DETERMINE USE AND PROPERLY INSULATE OR REMOVE WIRES IN OVERHEAD RUN IN ENGINE ROOM.
Condition: Unknown
Due 1 July 1988
Resolved 1 July 1988
Construction/Loadline
Issued 1 July 1988 Resolved
PROVIDE PROPER CLASS A BULKHEAD PENETRATIONS FOR CABLES PENETRATING THE BULKHEAD BETWEEN THE ENGINE ROOM AND THE VOID SPACE AFT OF THE ENGINE ROOM.
Condition: Unknown
Due 1 July 1988
Resolved 1 July 1988
Electrical
Issued 1 July 1988 Resolved
MAKE PERMANENT INSTALLATION OR REMOVE WIRES SUPPLYING POWER TO THE PORT ANDSTBD UPPER DECK LADDER LIGHTS.
Condition: Unknown
Due 1 July 1988
Resolved 1 July 1988
Lifesaving
Issued 1 July 1988 Resolved
PROVIDE SEPARATE STOWAGE LOCATIONS ON THE UPPER DECKS FOR ADULT AND CHILD LIFE PRESERVERS AND PROPERLY MARK THOSE LOCATIONS.
Condition: Unknown
Due 1 July 1988
Resolved 1 July 1988

Casualty record · 5

30 January 2003Routine · role: Involved in a Marine Casualty · activity 1737885
23 January 2006Routine · role: Involved in a Marine Casualty · activity 2602200
22 March 2010Routine · role: Involved in a Marine Casualty · at CANAL DRAW BRIDGE · activity 3727584
24 May 2024Routine · role: Involved in a Marine Casualty · activity 7949735
17 October 2025Routine · role: Involved in a Marine Casualty · activity 8256398
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

ANNABEL LEE (2003–2010). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.