MAURY USCG vessel records Sign in
← All vessels

PAPA JOE

PAPA JOE is a 1988 commercial fishing vessel. The Coast Guard has recorded 33 inspections since 1988, most recently in June 2006, along with 20 deficiencies.

Records from 1988 to 2006. Most recent: inspection, 27 June 2006.

Built
1988
Last inspected
27 June 2006
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WTB9391
302858
Flag
UNITED STATES
—
Maury page id
psix-302858

Inspections, by type

…with no type recorded4
Years with a record 19 calendar years (1988–2006)
The 33 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 20 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Fishing Vessel class in Maury's sources begin in 1972.

Documentation record

Registered dimensions (L × B × D)45.0 ft × 15.0 ft × 4.2 ft
Registered tonnagegross 18 / net 15
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDAVID'S ALUMINUM FABRICATORS INC · WESTWEGO, LA, UNITED STATES · built 1988
Hull materialAluminum
PropulsionDiesel Outdrive
Hull shapeShip
Hull configurationMonohull
Hailing portEMPIRE, LA
Trade endorsementsFishery
DocumentationValid · issued 29 January 2026 · expires 31 January 2027
Service, as the file records itCommercial Fishing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it18 - Simplified, Gross Ton
15 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WTB9391MMSI not assigned · expired · compulsorily equipped · granted 23 June 1998, cancelled 2 August 2008 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 33

27 June 2006 Administrative Inspection · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2693077
17 June 2005 COI Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2393658
20 April 2005 Hull Examination
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2338918
7 April 2005 Examination of Repairs
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2329134
9 September 2004 Annual Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2190934
29 August 2003 Annual Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1887043
27 May 2003 Internal Structural Exam · Hull Examination
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1803168
19 June 2002 Annual Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1633398
22 June 2001 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1366450
23 June 2000 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1369745
9 July 1999 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1093431
11 June 1999 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1369210
23 July 1998 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 798052
26 June 1998 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1447841
29 May 1998 Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1127027
14 November 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 668899
2 July 1997 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1451209
18 June 1996 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1400378
20 May 1996 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1402247
29 September 1995 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1422571
23 May 1995 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1355254
24 May 1994 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1419262
28 October 1993 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 668900
25 May 1993 Re-Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1423779
13 May 1993 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 144975
10 March 1993 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1146359
24 June 1992 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 954745
1 August 1991 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 668901
11 June 1991 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1009154
12 April 1990 Drydock Extension
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 925701
12 April 1990 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1234730
24 April 1989 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1341351
21 April 1988 Initial Certification
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1033795

Deficiency record · 20

Accommodation/Occupational Safety › Potable Water System
Issued 29 August 2003 Resolved
Replace potable water fill cap. LEGACY COMPONENT DESC: Fill Cap
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 September 2003
Resolved 29 August 2003
Lifesaving › Lifejacket/PFD (Type I)
Issued 29 August 2003 Resolved
Restencil vessel name on all child size PFD's and life bouy. LEGACY COMPONENT DESC: Marking
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 September 2003
Resolved 29 August 2003
Electrical › Electric Supply System (service)
Issued 29 August 2003 Resolved
Place dead end electrical wires in starboard engine compartment in electrical enclosure or remove. LEGACY COMPONENT DESC: Cable
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 September 2003
Resolved 29 August 2003
Engineering › Bilge Water Management System
Issued 29 August 2003 Resolved
Install metal pipe brace on bilge piping into collision bulkhead. LEGACY COMPONENT DESC: Piping
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 September 2003
Resolved 29 August 2003
Electrical › Electric Supply System (service)
Issued 29 August 2003 Resolved
Install metal straps in way of cable runs in hold space, starboard side. LEGACY COMPONENT DESC: Cable
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 September 2003
Resolved 29 August 2003
Unknown
Issued 11 June 1999 Resolved
CONDUCT DRILLS IN ACCORDANCE WITH 46CFR185.520,524 AND LOG SAME.
Condition: Unknown
Due 11 June 1999
Resolved 11 June 1999
Construction/Loadline
Issued 11 June 1999 Resolved
INSTALL BILGE HIGH LEVEL ALARMS WITH VISUAL AND AUDIBLE INDICATORS IN ACCORDANCE WITH 46CFR182.530.
Condition: Unknown
Due 11 June 1999
Resolved 11 June 1999
Construction/Loadline
Issued 26 June 1998 Resolved
WELD CRACKED WELDS IN FOREPEAK AND MID-BODY PORT CORNER.
Condition: Unknown
Due 26 June 1998
Resolved 26 June 1998
Deck/Cargo
Issued 26 June 1998 Resolved
REPLACE RELIEF VALVE ON AIR PUMP WITH ASME APPROVED RELIEF VALVE.
Condition: Unknown
Due 26 June 1998
Resolved 26 June 1998
Fire Fighting
Issued 26 June 1998 Resolved
REPLACE NOZZLE ON HOSE.
Condition: Unknown
Due 26 June 1998
Resolved 26 June 1998
Documentation
Issued 2 July 1997 Resolved
WRITTEN NOTICE WAS NOT RECEIVED 30 TO 60 DAYS PRIOR TO EXPIRATION OF COI THAT A SMALL PGR VSL WOULD BE REQUIRED TO BE INSPECTED. NOTICE RECEIVED 02JUL97; COI EXPIRED 24MAY97.
Condition: Unknown
Due 2 July 1997
Resolved 3 July 1997
Documentation
Issued 2 July 1997 Resolved
VESSEL COI EXPIRED 24MAY97. VESSEL LOGS INDICATE CONTINUED OPERATION.
Condition: Unknown
Due 2 July 1997
Resolved 3 July 1997
Accommodation/Occupational Safety
Issued 20 May 1996 Resolved
PROVIDE AND MOUNT MARPOL, GARBAGE DISCHARGE, PLACARD
Condition: Unknown
Due 20 May 1996
Resolved 20 May 1996
Documentation
Issued 20 May 1996 Resolved
PROVIDE FCC SAFETY RADIO TELEPHONY CERTIFICATE, VESSEL IS RESTRICTED TO NOTMORE THAN 1000 FEET FROM SHORE
Condition: Unknown
Due 20 May 1996
Resolved 20 May 1996
Engineering
Issued 20 May 1996 Resolved
LABEL FUEL OIL SHUTOFF VALVES
Condition: Unknown
Due 20 May 1996
Resolved 20 May 1996
Fire Fighting
Issued 20 May 1996 Resolved
INSTALL PRESSURE GUAGE ON DISCHARGE SIDE OF FIRE PUMP
Condition: Unknown
Due 20 May 1996
Resolved 20 May 1996
Electrical
Issued 20 May 1996 Resolved
PROVIDE GLOBE (GLASS) FOR LIGHT FIXTURE IN PORT ENGINE COMPARTMENT
Condition: Unknown
Due 20 May 1996
Resolved 20 May 1996
Fire Fighting
Issued 20 May 1996 Resolved
INSTALL PORTABLE FIRE EXTINGUISHER BRACKET AT OPERATOR'S STATION
Condition: Unknown
Due 20 May 1996
Resolved 20 May 1996
Accommodation/Occupational Safety
Issued 20 May 1996 Resolved
REPLACE/REPAIR MSD LEVEL INDICATOR GUAGE (3/4 FULL)
Condition: Unknown
Due 20 May 1996
Resolved 20 May 1996
Construction/Loadline
Issued 20 May 1996 Resolved
PROVIDE METALLIC BILGE PIPING SYSTEM WHICH RUNS THROUGH A CENTRAL CONTROL POINT OR MANIFOLD
Condition: Unknown
Due 20 June 1996
Resolved 12 June 1996

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.