Records from 2001 to 2025. Most recent: inspection, 17 June 2025.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 28
17 June 2025
Deficiency Check · Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Lihue · USCG Oceania District (CGD-O) · Activity 8161531
7 August 2024
Internal Structural Exam · Drydock Exam · Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Lihue · USCG Oceania District (CGD-O) · Activity 7980797
9 August 2023
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7763692
30 May 2023
Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7701356
25 May 2022
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7464969
12 May 2021
COI Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7195222
7 December 2020
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7107618
1 June 2020
Deficiency Check · Internal Structural Exam · Annual Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6965787
10 May 2019
Deficiency Check · DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6683246
22 May 2018
Drydock Exam · Internal Structural Exam · Administrative Inspection · DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6420999
9 May 2017
DAPI Audit · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6143276
2 May 2016
COI Inspection · DAPI Audit · Internal Structural Exam · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5863176
16 May 2014
Internal Structural Exam · Hull Examination · DAPI Audit · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4885390
17 May 2012
Annual Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4314483
15 October 2008
Damage Survey
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3345473
25 June 2008
DAPI Audit · Annual Inspection · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3247697
19 June 2007
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2967099
14 June 2007
Hull Examination · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2966414
14 June 2007
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2974968
19 June 2006
COI Inspection · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2673288
1 July 2004
Annual Inspection · Construction Oversight · Hull Examination · Deficiency Check · Plan Review "T" Boat
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2125277
31 January 2004
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2025873
19 August 2003
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1886904
11 July 2003
Hull Examination · Annual Inspection · Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1843536
18 July 2002
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1717280
19 June 2002
Annual Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1632287
24 August 2001
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1073379
28 June 2001
Initial Certification · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1408786
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 17 June 2025
Resolved
Vessels operated solely within 20 nautical miles of land must be equipped with a VHF-DSC radiotelephone installation meeting the requirements of § 80.1101(c)(2). VHF radio missing MMSI and LAT/LONG for DSC operation.
47 CFR 80.905
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2025
Resolved 4 August 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 June 2025
Resolved
In systems and applications where flexible hoses are permitted to be clamped: Double hose clamping is required where practicable. Missing double hose clamps on some systems. Provide double hose clamps.
46 CFR 182.410(d)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2025
Resolved 3 July 2025
Resolution: Double hose clamps provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 June 2025
Resolved
Each ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018. 01 life ring buoys on board vessel are missing Type II retroreflective material. 1 life ring buoy retroreflective material is worn. Add/replace retroreflective type material on life ring buoys.
46 CFR 185.604(i)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 June 2025
Resolved 3 July 2025
Resolution: Retro tape provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 June 2025
Resolved
Battery installations must be mounted to 46 CFR 183.350 to protect against shifting of the vessel and free from exposure to water splash or spray. Vessel's battery box not secured. Provide secured battery boxes.
46 CFR 183.350
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2025
Resolved 3 July 2025
Resolution: Batteries secured.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 1 June 2020
Resolved
47 CFR 80.903 - Every SPV subject to FCC regulations is required to have its radio installation inspected by an certified FCC technician had maintain a valid FCC Safety Radiotelephony Certificate. Vessel FCC Safety Radiotelephony Certificate is expired. Provide a valid FCC Safety Radiotelephony Certificate.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2020
Resolved 15 June 2020
Resolution: Vessel submitted valid FCC certificate. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 10 May 2019
Resolved
Vessels on limited coastwise routes are required a mimimum of 12 flares. Only 8 flares were present. Provide a sufficient number of flares.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 May 2019
Resolved 15 May 2019
Resolution: Missing flares provided.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 10 May 2019
Resolved
Disposable hydrostatic releases for EPIRBs are required to be replaced 2 years after the unit was installed. The hydrostatic release will expire the end of May 2019. Provide a new hydrostatic release.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2019
Resolved 15 May 2019
Resolution: Disposable hydrostatic release replaced with a new hydro.
Lifesaving › Visual Distress Signals (General) › Not on Board
Issued 22 May 2018
Resolved
Vessels on a limited coastwise route are required to have 12 flares total. At the time of inspection only 8 flares were made available. Provided required number of flares.
Action required: 705 - Other - as specified
Due 30 May 2018
Resolved 23 May 2018
Resolution: 4 additional flares were provided, inspected and placed into service on board the vessel.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 19 June 2006
Resolved
Provide CG light list, rules to the road and US Coast Pilot.
Condition: Unknown
Due 15 July 2006
Resolved 14 June 2007
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 19 June 2006
Resolved
Provide fixed fire system IAW 46CFR181.400 or remove all igniton sources from fuel tank space.
Condition: Unknown
Due 15 July 2006
Resolved 14 June 2007
Communications › Radio Communications › EPIRB
Issued 1 July 2004
Resolved
Prove operation of EPIRB prior to carrying passengers per 46 CFR 185.728, 180.64, CIDNOTE #22. EPIRB was inoperable when tested by the test function.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 July 2004
Communications › Radio Communications › EPIRB
Issued 1 July 2004
Resolved
Install EPIRB hydrostatic release. Hydro was past due date since July 2003.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 July 2004
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 1 July 2004
Resolved
Remove improper plastic fuel tank per 46CFR182.440. Directed by ACID to not write as a no-sail deficiency, since it was a previous inspector's oversight.
Due 31 July 2004
Resolved 3 September 2004
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 1 July 2004
Resolved
Install proper fuel tank per 46 CFR 182.440.
Due 31 July 2004
Resolved 3 September 2004
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 1 July 2004
Resolved
Install fixed fire extinguishing system per 46 CFR 181.400. No system presently onboard.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 July 2004
Navigation › Piloting/Steering › Marine Charts
Issued 1 July 2004
Resolved
Provide required charts and publications per 46 CFR 184.420, e.g. Tidal Current Tables, Rules of he Road, Coast Pilot [name withheld] and Tide Tables. Not written as a no-sail per ACID.
Due 31 July 2004
Resolved 7 July 2004
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 1 July 2004
Resolved
Prove compliant chemical testing program per 46 CFR 16. Could not complete audit based on Owner's lack of knowledge. No MIS report submitted. Policy was inadequate, missing return to work policy, statement regarding positive results forwarded to CG. Audit form noted owner's need to review federal regulations & implement in plan. Progran in substantial non-compliance. Not a no-sail per ACID.
Due 31 July 2004
Resolved 7 July 2004
Fire Fighting › Remote Fuel Shutoff › General
Issued 1 July 2004
Resolved
Label emergency fuel shutoff valves per 46 CFR 185.608. Not a no-sail per ACID.
Due 31 July 2004
Resolved 7 July 2004
Navigation › Piloting/Steering › Magnetic Compass
Issued 1 July 2004
Resolved
Properly mount magnetic compass per 46 CFR 84.402.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 July 2004
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 1 July 2004
Resolved
Provide first aid kit with required contents per 46 CFR 160.041.
Due 31 July 2004
Resolved 7 July 2004
Engineering › Gasoline Engine (propulsion) › Gasoline Fuel Tank Ventilation
Issued 1 July 2004
Resolved
Properly install flame screen on starboard fuel vent per 46 CFR 182.450 (e). Current installation has a gap that could allow flames to ignite vapors coming out of the vent. Not a no-sail per ACID.
Condition: Improper Installation
Due 31 July 2004
Resolved 7 July 2004
Fire Fighting › Fire Bucket › Quantity
Issued 1 July 2004
Resolved
Install two fire buckets per 46 CFR 181.610. Vessel only had one onboard. Not a no-sail per ACID.
Due 31 July 2004
Resolved 7 July 2004
Operations/Management › Drills/Instruction › Not Conducted
Issued 1 July 2004
Resolved
Conduct Annual Exam fire and man overboard drills.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 July 2004
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 1 July 2004
Resolved
Conduct underway operation of vessel to complete annual exam.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 July 2004
Operations/Management › Drug and Alcohol Testing
Issued 20 June 2003
Resolved
Comply with drug and alcohol testing requirements, for pre-employment and random employee testing. Provide Company drug and alcohol policy w/ signature sheet and initiate a EAP program. LEGACY COMPONENT DESC: Testing, Pre-employment
Condition: Improper/Lack of Maintenance
Due 20 July 2003
Resolved 10 July 2003
Engineering › Gasoline Engine (propulsion)
Issued 20 June 2003
Resolved
Start port side outboard engine and conduct u/w test.
Due 20 July 2003
Resolved 20 June 2003
Operations/Management › Drug and Alcohol Testing
Issued 19 June 2002
Resolved
There is no evidence of current enrollment in a EAP/Drug Testing Consortium. Provide proof of current enrollment in a durg screening program/consortium in accordance with 46 CFR Part 16. LEGACY COMPONENT DESC: Employee Coverage
Action required: 705 - Other - as specified
Due 19 July 2002
Resolved 18 July 2002
Resolution: Owner provided proof of consortium registration.
Operations/Management › Drills/Instruction
Issued 19 June 2002
Resolved
There is no evidence that training or drills is being conducted or that the EPIRB is being checked monthly. There was no means presented for accounting for passengers. Provide a logbook documenting training, EPIRB tests, and required drills in accordance with 46CFR 185.420 & 185.520. LEGACY COMPONENT DESC: Logkeeping
Action required: 705 - Other - as specified
Due 19 July 2002
Resolved 18 July 2002
Resolution: Master provided log with drills and monthly EPIRB test.
Navigation › Collision/Grounding Avoidance
Issued 19 June 2002
Resolved
The all around white light mounted on the stern is inoperable. Provide proof of repair to sternlight in accordance with 46CFR 183.420. Note: Vessel COI limits operation to daylight hours only. LEGACY COMPONENT DESC: Navigation Lights
Action required: 705 - Other - as specified
Due 19 July 2002
Resolved 18 July 2002
Resolution: Master provided working navigation lights.
Communications › Radio Communications
Issued 19 June 2002
Resolved
The vessel did not have an Emergency Broadcast Placard. Provide an Emergency Broadcast Placard in accordance with 46CFR 184.506. LEGACY COMPONENT DESC: Emergency Broadcast Placard
Action required: 705 - Other - as specified
Due 19 July 2002
Resolved 18 July 2002
Resolution: Master provided Emergency Broadcast Placard.
Lifesaving › Lifejacket/PFD (Type I)
Issued 19 June 2002
Resolved
The vessel did not have lifejackets aboard in the quantities specified by the COI. Provide 4 more adult and 1 more child size lifejackets in accordance with 46CFR 180.71. Vessel is restricted to the carriage of 18 adult and 2 child sized passengers until corrected. LEGACY COMPONENT DESC: Quantity
Action required: 705 - Other - as specified
Due 19 July 2002
Resolved 18 July 2002
Resolution: Master provided all required lifejackets.
Lifesaving › Lifejacket/PFD (General)
Issued 19 June 2002
Resolved
Found upper portion of lifejacket donning procedures placard wiped clean. Replace existing faded lifejacket donning placard in accordance with 46CFR 185.516. LEGACY COMPONENT DESC: Donning Instructions
Action required: 705 - Other - as specified
Due 19 July 2002
Resolved 18 July 2002
Resolution: Master provided new lifejacket donning placard.
Lifesaving › Emergency Outfit
Issued 19 June 2002
Resolved
Several items were missing from the 1st aid kit. Replace expired items in 1st aid kit and replenish missing items to bring kit up to standard in accordance with modified list provided from 46CFR 160.041. LEGACY COMPONENT DESC: 1st Aid Kit
Action required: 705 - Other - as specified
Due 19 July 2002
Resolved 18 July 2002
Resolution: Master provided a 1st aid kit in accordance with regulations.
Fire Fighting › Remote Fuel Shutoff
Issued 19 June 2002
Resolved
Vessel operator unable to locate/demonstrate the fuel oil cut-off valves. Provide and demonstrate method for quickly securig fuel to outboard engines in the event of a fire (fuel oil cut-of valves for forward and aft fuel tanks).
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 19 July 2002
Resolved 18 July 2002
Resolution: Master provided fuel cut off valves for outboard engines.
Pollution Prevention/Response › Prevention Equipment
Issued 19 June 2002
Resolved
Found worn and barely readable MARPOL V and Oil Pollution placards. Provide legible MARPOL V and Oil Pollution placards in accordance with 33CFR 155.450 & 151.59. LEGACY COMPONENT DESC: Placards
Action required: 705 - Other - as specified
Due 19 July 2002
Resolved 18 July 2002
Resolution: Master provided new MARPOL V and Oil pollution placard.
Engineering
Issued 28 June 2001
Resolved
Provide proof that F/O hoses meet requirements as outlined in 46CFR182.720(e).
Condition: Unknown
Due 15 July 2001
Resolved 24 August 2001