Records from 2011 to 2026. Most recent: inspection, 30 July 2026.
Inspection history · 53
30 July 2026
Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8451173
4 July 2026
Attraction Vessel Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8427401
27 October 2025
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8259188
19 September 2025
Attraction Vessel Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8238641
25 August 2025
Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8198514
8 October 2024
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7997912
6 June 2024
In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7931753
13 November 2023
Attraction Vessel Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7824074
28 September 2023
Hull Examination · Annual Inspection · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7781576
14 November 2022
Attraction Vessel Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7593794
6 October 2022
Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7574921
12 May 2022
Attraction Vessel Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7479052
15 November 2021
Attraction Vessel Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7351285
5 November 2021
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7346037
22 October 2021
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7338005
20 October 2021
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7336314
12 October 2021
COI Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7331290
24 September 2021
Drydock Exam · Internal Structural Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7319472
3 September 2021
Attraction Vessel Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7305985
3 June 2021
In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7253541
20 November 2020
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7089490
15 October 2020
Attraction Vessel Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7094555
28 February 2020
Special
Type not classified · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6917697
17 December 2019
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6861826
21 November 2019
Excursion Permit
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6861966
13 November 2019
Attraction Vessel Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6853870
8 October 2019
Attraction Vessel Exam · In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6834888
3 October 2019
Attraction Vessel Exam · Administrative Inspection · In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6827078
23 September 2019
Drydock Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6819205
5 April 2019
Administrative Inspection · Special · Attraction Vessel Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6656450
6 February 2019
Attraction Vessel Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6621302
18 January 2019
DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6611976
4 January 2019
Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6607392
6 December 2018
Special · Attraction Vessel Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6586653
31 October 2018
In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6571693
17 October 2018
Attraction Vessel Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6576555
31 August 2018
In-Service Inspection · Attraction Vessel Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6527131
27 August 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6524159
1 June 2018
In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6423280
23 May 2018
Administrative Inspection · Attraction Vessel Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6394997
8 March 2018
In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6368314
4 December 2017
Annual Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6294892
8 November 2017
Attraction Vessel Exam · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6303456
1 November 2017
In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6298254
27 October 2017
In-Service Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6298848
6 October 2017
Internal Structural Exam · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6286122
16 June 2017
In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6180224
10 March 2017
Type not recorded
No type recorded · Station St Petersburg · USCG Southeast District (CGD-SE) · Activity 6103936
10 February 2017
Excursion Permit · Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6085865
25 November 2016
Attraction Vessel Exam · Deficiency Check · Special
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6045890
31 October 2016
Deficiency Check · COI Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6030573
3 June 2016
Attraction Vessel Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5896341
6 January 2016
DAPI Audit · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5789205
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 22 October 2021
Resolved
A self propelled vessel of 65 feet or more in length, engaged in commercial service must have a properly installed, operational Coast Guard Type approved AIS onboard. Vessels AIS is not currently operational. 33 CFR 164.46
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 November 2021
Resolved 15 November 2021
Resolution: AIS Installed
01 - Certificates & Documentation › 012 - Crew Certificates › Doc evidence for personnel on passenger ships
Issued 12 October 2021
Resolved
DAPI complaince paperwork incomplete.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 October 2021
Resolved 22 October 2021
Resolution: Recieved DAPI paperwork via email.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 12 October 2021
Resolved
Charts missing for route.
Coast Pilot Missing
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 October 2021
Resolved 22 October 2021
Resolution: Rcvd evidence of Nautical Pubs were downloaded to stand-alone device. Purchase of charts.
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 12 October 2021
Resolved
Could not demonstrate test of VHF/DSC
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 October 2021
Resolved 22 October 2021
Resolution: Photo of successful DSC test
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 12 October 2021
Resolved
Alarms for crew spaces were expired and did not have UL 217 conformance
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 October 2021
Resolved 22 October 2021
Resolution: MI from Sector Maryland-NCR ([name withheld]) verified purchase, testing and installion of UL217 approved Smoke Detectors onboard vessel
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 October 2021
Resolved
Epirb missing outer latch, allowing water to get into the case.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2021
Resolved 3 November 2021
Resolution: Could not find new cover. Replaced EPIRP.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 12 October 2021
Resolved
Gauges not working at the operating station.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2021
Resolved 28 April 2022
Resolution: Rcv'd evidence (email) of defs being completed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 October 2021
Resolved
Sight glass on both fuel tanks is made from fuel hose.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 October 2021
Resolved 22 October 2021
Resolution: Plastic sight-glasses removed. Valves closed and capped.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 October 2021
Resolved
Battery terminals loose on the gen starting battery (top)
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2021
Resolved 3 November 2021
Resolution: Tightened
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 October 2021
Resolved
Racor on fwd blkhd(bottom) lacks flame impingment bowl or metal bottom with tapered plug.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2021
Resolved 28 March 2022
Resolution: See activity 7351285 for update on this item.
Def Closed 3/28/22.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 October 2021
Resolved
Boom Topping lift double braided nylon has core showing around aftermost thimble and needs to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2021
Resolved 3 November 2021
Resolution: Replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 20 November 2020
Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment, other than small buoyancy compartments, under all practicable conditions. Vessel was unable to demostrate their bilge pumping system.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 November 2020
Resolved 20 November 2020
Resolution: Vessel was able to demostrate their bilge system.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 November 2020
Resolved
Connections must be made to battery terminals with permanent type connectors. Spring clips or other temporary type clamps are prohibited. Vessel had wing nuts on their starting batteries for their generator.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 December 2020
Resolved 20 November 2020
Resolution: Vessel installed wing nuts.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 20 November 2020
Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. Post side, aft FO valve would not shut all the way.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 December 2020
Resolved 20 November 2020
Resolution: Corrected on the spot.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 20 November 2020
Resolved
A hatch exposed to the weather must be watertight. The FO shut off on the starboard side aft one on the main deck is leaking water in the engine room.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 November 2020
Resolved 20 November 2020
Resolution: Cleared on the spot.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 20 November 2020
Resolved
Gauges to indicate engine revolutions per minute (RPM), jacket water discharge temperature, and lubricating oil pressure must be provided for all propulsion engines installed in the vessel. The gauges must be readily visible at the operating station. The LO and JW gauge do not work at the helm.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 December 2020
Resolved 14 November 2022
Resolution: See activity 7351285 for update on this item
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 January 2019
Resolved
A vessel must have one or more ring life buoys approved in accordance with 46 CFR 160.050 in subchapter Q.
Ring life buoy grab line is deteriorated.
Replace grab line. 46CFR180.70
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 February 2019
Resolved 13 March 2019
Resolution: Operator installed new ring buoy and grab line.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 27 August 2018
Resolved
Vsl is broadcasting: Call Sign from expired FCC License.
Condition: Invalid
Action required: 705 - Other - as specified
Due 27 September 2018
Resolved 30 August 2018
Resolution: Checked FCC LIC call sign and EXP. date SAT, looked at call sign AIS "A" broadcasting as same as well.
Lifesaving › Visual Distress Signals (General) › Expired
Issued 27 October 2017
Resolved
Vessel had 02 orange smoke distress signals that were expired. Ensure non-expired orange smoke or red flare equivalent are onboard. Vessel restricted to Lake, Bays, Sounds route until 02 smke/red flare are provided.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 October 2017
Resolved 1 November 2017
Resolution: Qualified Marine inspector witnessed correct number of flares for LBS plus LC route.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 27 October 2017
Resolved
EPIRB hydrostatic release is expired. Ensure EPIRB is equipped with valid hydrostatic release . Vessel is restricted to waters within 3nm of coastline.
Condition: Invalid
Action required: 705 - Other - as specified
Due 27 October 2017
Resolved 1 November 2017
Resolution: Qualified Marine inspector witnessed new hydrostatic release.
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 27 October 2017
Resolved
Vessel had escessive paint and solvents stowed in engine compartment. N0 more than five gallons of flammable liquids may be stowed in any machinery space in containers of one gallon or less. Stow all paints/solvents in exces of fove gallons in an appropriate receptacle or remove from vessel prior to carrying passengers.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 October 2017
Resolved 1 November 2017
Resolution: Master attested to the removal of all excess paints and solvents from the vessel.
Communications › Alarms/Indicators › Bilge Alarm
Issued 31 October 2016
Resolved
Repair forepeak bilge alarm, can barely hear buzzer and light is not functioning.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2016
Resolved 27 November 2016
Resolution: Operator replaced float switch, verified proper operation.
Documentation › Certificates/Documents › Permit, Other
Issued 31 October 2016
Resolved
Provide FCC Marine Radio Operators Permit.
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 November 2016
Resolved 10 November 2016
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 31 October 2016
Resolved
Provide alcohol test kits. Current kits are expired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2016
Resolved 7 November 2016
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 31 October 2016
Resolved
Ammonia Inhalents expired and 1st aid kit is missing required items as per 46 CFR 160.041.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2016
Resolved 30 November 2016
Resolution: Verified required items were replaced.