Records from 1988 to 2026. Most recent: inspection, 19 May 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 55
19 May 2026
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8376349
19 August 2025
Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8162071
12 November 2024
Drydock Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8033480
6 May 2024
Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7907576
16 May 2023
Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7690612
30 November 2022
Drydock Exam · Administrative Inspection · Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7603084
20 April 2022
Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7434492
29 April 2021
Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7185941
10 February 2021
Administrative Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7138467
23 November 2020
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7100638
6 May 2020
COI Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6951636
1 July 2019
Administrative Inspection · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6732440
24 June 2019
Plan Review "T" Boat · Simplified Stability Test · Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6723703
10 April 2019
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6660100
30 October 2018
Drydock Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6571000
23 January 2012
DAPI Audit · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4230078
5 March 2008
Deficiency Check · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3296736
4 June 2007
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2946434
5 June 2006
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2666235
15 June 2005
COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2376971
9 June 2004
Annual Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2086348
16 June 2003
Annual Inspection · Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1825603
23 December 2002
Damage Survey
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1722321
20 December 2002
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1721535
28 May 2002
Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1632251
16 May 2002
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1617739
10 May 2002
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1618730
19 July 2001
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 52035
5 June 2001
Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1472636
11 September 2000
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 33534
18 July 2000
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1429391
26 August 1999
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 780601
13 July 1999
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1361019
16 April 1999
Hull Examination · COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1429167
8 October 1998
Plan Review "T" Boat · Examination of Repairs
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 802707
18 June 1998
Damage Survey
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1427542
12 June 1998
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 138254
12 June 1998
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 231638
28 June 1997
Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 781540
11 April 1997
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1450030
5 March 1996
Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1412952
26 August 1995
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 73077
8 March 1995
Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1396275
14 June 1994
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1325055
17 May 1994
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 145874
8 March 1994
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1379930
10 March 1993
Hull Examination · Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 833344
7 March 1993
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 145861
14 March 1992
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 952217
21 March 1991
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1241285
14 March 1991
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1241284
21 May 1990
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 909670
14 April 1990
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1219565
20 April 1989
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1345163
12 May 1988
Initial Certification · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1040302
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 19 August 2025
Resolved
A person may not employ or engage an individual in a position required to hold an MMC unless that individual maintains a current medical certificate. Master of vessel did not have a medical certificate. Vessel may not operate until a master with a valid medical certificate is provided.
46 CFR 15.401(c)
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 September 2025
Resolution: Observed completed medical certificate process.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 August 2025
Resolved
Fire extinguishing equipment installed on a vessel in excess of the requirements of §§ 181.400 and 181.500 must be designed, constructed, installed, and maintained in accordance with a recognized industry standard acceptable to the Commandant (CG-ENG-4). MI’s observed the following on the fixed carbon dioxide system: 1) no fire servicing report attesting to annual maintenance, 2) cylinder was not properly secured, 3) hydrostatic inspection was expired.
46 CFR 182.530
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 September 2025
Resolution: Observed cylinder had been hydrostatically tested and secured properly
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 19 August 2025
Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces: A space with a non-watertight closure, such as a space with a non-watertight hatch on the main deck. MI observed bilge alarms not working in fuel tank void and battery room void.
46 CFR 182.530
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 September 2025
Resolution: Observed fully functioning bilge alarms
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 19 August 2025
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspection of electrical equipment and systems, including the following (a) Inspection of all cable as far as practicable without undue disturbance of the cable or electrical apparatus. MI observed Port and starboard aft engine room lights being improperly supported by electrical wire. Lighting fixtures should be installed according to manufacturer's instructions.
46 CFR 176.806
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 September 2025
Resolved 24 September 2025
Resolution: Observed properly secured lights
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 19 August 2025
Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with § 80.59 once every five years. MI observed the vessel’s Safety Radiotelephony Certificate expired in 2024. Restricted to 1000' from shore.
46 CFR 80.903
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 24 September 2025
Resolution: Observed new Safety Radiotelephony Certificate
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 19 August 2025
Resolved
Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information: (1) Date of the drill and training; and (2) General description of the drill scenario and training topics. Fire fighting drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information: (1) Date of the drill and training; and (2) General description of the drill scenario and training topics. MI observed fire and man-overboard drills not logged.
46 CFR 185.520(f)
46 CFR 185.524(d)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 19 August 2025
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 16 May 2024
Resolved
Excessive accumulation of water was noted from the port rudder which was seeping water past the packing glands. Tighten packing gland to prevent excessive water from entering the vessel.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2024
Resolved 16 May 2024
Resolution: Excessive accumulation of water was noted from the port rudder which was seeping water past the packing glands. Tighten packing gland to prevent excessive water from entering the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 May 2024
Resolved
A vessel must carry one floating waterlight. Life ring floating marker light has expired battery. Replace with in date battery.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2024
Resolved 21 May 2024
Resolution: A vessel must carry one floating waterlight. Life ring floating marker light has expired battery. Replace with in date battery.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 16 May 2024
Resolved
Each electrical connection...must be within an enclosure and secured to prevent loosening. wiring was noted disconnected under the vessels starboard engine. Reconnect the wires, secure the ends in a junction box or pack pull and remove the wires.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2024
Resolved 16 May 2024
Resolution: Each electrical connection...must be within an enclosure and secured to prevent loosening. wiring was noted disconnected under the vessels starboard engine. Reconnect the wires, secure the ends in a junction box or pack pull and remove the wires.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 29 April 2021
Resolved
Each nozzle must be of a corrosion-resistant material and be capable of being changed between a solid stream and a spray pattern. Vessels current arrangement did not provide for successful transition from straight stream to flush due to lack of maintenance and corrosion. Replace or repair to satisfaction of MI.
46 CFR 181.320 (d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2021
Resolved 2 July 2021
Resolution: Vessel rep submitted objective evidence clearing deficiency for hose and nozzle.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 17 July 2019
Resolved
Ladder leading to anchor locker is loose off of the bulkhead.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 May 2020
Resolution: Witnessed ladder fixed at time of Annual isnpection, all sat
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 23 January 2012
Resolved
Repair broken stantion on aft boarding deck.
Action required: 705 - Other - as specified
Due 14 April 2012
Resolved 14 May 2012
Resolution: Re-welded broken stantion.
Stability › Weathertight Integrity › General
Issued 23 January 2012
Resolved
Repair leaking deck drain on aft port quarter.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 April 2012
Resolved 14 May 2012
Resolution: Repaired leaking deck drain.
Stability › Watertight Integrity › General
Issued 23 January 2012
Resolved
Tighten port rudder packing.
Action required: 705 - Other - as specified
Due 14 April 2012
Resolved 14 May 2012
Resolution: Tightened ridder packing.
Engineering › Reduction Gearing/Clutches
Issued 23 December 2002
Resolved
Repair gear casing and any associated damage incurred in grounding of vessel. LEGACY COMPONENT DESC: Casing
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 April 2003
Resolved 16 June 2003
Resolution: Inspected installation of both new reduction gears.
Construction/Loadline › Hull
Issued 23 December 2002
Resolved
Repair FRP damage to the keel incurred during grounding of the vessel. LEGACY COMPONENT DESC: Keel
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 April 2003
Resolved 16 June 2003
Resolution: Inspected satisfactory repairs to skeg.
Engineering › Shafting/Propeller Arrangements
Issued 23 December 2002
Resolved
Repair/replace damaged propellors incurred during grounding of the vessel. LEGACY COMPONENT DESC: Propeller (fixed pitch)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 April 2003
Resolved 16 June 2003
Resolution: Operator installed new propellers.
Operations/Management › Drills/Instruction
Issued 28 May 2002
Resolved
Perform fire/man overboard drill to the satisfaction of the attending Coast Guard Marine Inspector. LEGACY COMPONENT DESC: Man Overboard Recovery
Due 15 June 2002
Resolved 16 June 2003
Resolution: Witnessed satisfactory drills.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 16 May 2002
Resolved
Provide the necessary documentation showing the completion of work, probable cause and operational check of failed engine turbocharger. LEGACY COMPONENT DESC: Turbocharger
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 May 2002
Resolved 17 May 2002
Accommodation/Occupational Safety
Issued 13 July 1999
Resolved
Resecure Port Upper Deck Rail IAW 46CFR177.900
Condition: Unknown
Due 13 July 1999
Resolved 13 July 1999
Accommodation/Occupational Safety
Issued 13 July 1999
Resolved
Resecure Overhead Paneling in Sewage Compartment Port Side.
Condition: Unknown
Due 20 July 1999
Resolved 20 July 1999
Electrical
Issued 13 July 1999
Resolved
Seal Electrical Stuffing Tubes, number in use (Port Side) in Steering Compartment.
Condition: Unknown
Due 20 July 1999
Resolved 20 July 1999
Fire Fighting
Issued 13 July 1999
Resolved
Repair Fire Main System Piping Leaks (3) IAW 45CFR176.800
Condition: Unknown
Due 14 July 1999
Resolved 20 July 1999
Engineering
Issued 13 July 1999
Resolved
Resecure Bonding Wire to Port Fuel Oil Tank (46CFR182.400
Condition: Unknown
Due 20 July 1999
Resolved 20 July 1999
Fire Fighting
Issued 16 April 1999
Resolved
Install fire detection in engine room.
Condition: Unknown
Due 16 April 1999
Resolved 16 April 1999
Engineering
Issued 16 April 1999
Resolved
Correct fuel leaks in system.
Condition: Unknown
Due 16 April 1999
Resolved 16 April 1999
Electrical
Issued 16 April 1999
Resolved
Correct battery terminals.
Condition: Unknown
Due 16 April 1999
Resolved 16 April 1999
Electrical
Issued 16 April 1999
Resolved
Hard wire all battery chargers.
Condition: Unknown
Due 16 April 1999
Resolved 16 April 1999
Accommodation/Occupational Safety
Issued 16 April 1999
Resolved
Mount all benches and have vessel ready for passengers.
Condition: Unknown
Due 16 April 1999
Resolved 16 April 1999
Engineering
Issued 16 April 1999
Resolved
Install plugs in J/W system, both main engines.
Condition: Unknown
Due 16 April 1999
Resolved 16 April 1999
Unknown
Issued 11 April 1997
Resolved
Provide inventory and instructions for first aid kit._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 25 April 1997
Resolved 16 May 1997
Engineering
Issued 11 April 1997
Resolved
Pvovide rotating machinery guards on Stbd Jabsco pump._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 April 1997
Resolved 11 April 1997
Engineering
Issued 11 April 1997
Resolved
Provide turbocharger exhaust blankets on inboard sides of port and stbd engines._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 May 1997
Resolved 16 May 1997
Lifesaving
Issued 11 April 1997
Resolved
Provide life jacket donning placard._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 April 1997
Resolved 11 April 1997
Fire Fighting
Issued 8 March 1994
Resolved
PROVIDE MEANS OF AUTOMATIC SHUTDOWN OF MDE'S PRIOR TO ACTIVATING HALON SYSTEM.
Condition: Unknown
Due 8 March 1994
Resolved 8 March 1994
Engineering
Issued 8 March 1994
Resolved
INSTALL REAPIRED TACH DRIVE CABLE FOR EACH MAIN DIESEL ENGINE.
Condition: Unknown
Due 8 March 1994
Resolved 8 March 1994
Engineering
Issued 8 March 1994
Resolved
INSTALL GUARD IN WAY OF EACH MAIN DIESEL ENGINE.
Condition: Unknown
Due 8 March 1994
Resolved 8 March 1994
Engineering
Issued 10 March 1993
Resolved
PROVE PROPER OPERATION OF STARBOARD MAIN DIESEL ENGINE PRIOR TO CARRIAGE OFPASSENGERS FOR HIRE.
Condition: Unknown
Due 10 March 1993
Resolved 10 March 1993
Documentation
Issued 10 March 1993
Resolved
PROVIDE EVIDENCE OF COMPLIANCE WITH THE REQUIREMENTS IN 46 CFR 16 FOR CHEMICAL (DRUG) TESTING OF CREW, INCLUDING RANDOM TESTING.
Condition: Unknown
Due 9 April 1993
Resolved 14 April 1993
Lifesaving
Issued 10 March 1993
Resolved
RENEW WASTED (WET ROT) LADDER IN WAY OF AFT CHAIN LOCKER COMPARTMENT WHICH COLLASPED DURING INSPECTION.
Condition: Unknown
Due 17 March 1993
Resolved 14 April 1993
Engineering
Issued 10 March 1993
Resolved
PROVE PROPER OPERATION OF SUPPLY AND EXHAUST VENTILATION FANS IN ENGINE COMPARTMENT.
Condition: Unknown
Due 10 March 1993
Resolved 10 March 1993
Construction/Loadline
Issued 14 March 1991
Resolved
MAKE REPAIRS TO AFT SECTION OF PASSENGER LOADING/UNLOADING PLATFORM ON THE PORT SIDE BY COMPLETION OF THE NEXT SCHEDULED DRYDOCK.
Condition: Unknown
Due 14 March 1991
Resolved 14 March 1991
Navigation
Issued 14 April 1990
Resolved
REPAIR OR REPLACE INOPERATIVE MASTHEAD LIGHT.
Condition: Unknown
Due 14 April 1990
Resolved 14 April 1990
Documentation
Issued 14 April 1990
Resolved
PROVIDE A CURRENT AND ORIGINAL COAST GUARD MARINE DOCUMENT.
Condition: Unknown
Due 14 April 1990
Resolved 14 April 1990
Construction/Loadline
Issued 14 April 1990
Resolved
PROVIDE A CAPTURE CHAIN FOR STEERING GEAR COMPARTMENT IAW 46 CFR 171.124(B).
Condition: Unknown
Due 14 April 1990
Resolved 14 April 1990
Accommodation/Occupational Safety
Issued 12 May 1988
Resolved
ADD TO THE MSD INSTRUCTIONS TO INCLUDE BURNING MATERIALS (CIGARETTES, MATCHES, ETC.).
Condition: Unknown
Due 12 May 1988
Resolved 12 May 1988
Construction/Loadline
Issued 12 May 1988
Resolved
PERMANENTLY MARK THE VESSEL'S OFFICIAL NUMBER AND MARK THE PROPER HAILING PORT.
Condition: Unknown
Due 12 May 1988
Resolved 12 May 1988
Documentation
Issued 12 May 1988
Resolved
PROVIDE THE VESSEL'S MARINE DOCUMENT.
Condition: Unknown
Due 12 May 1988
Resolved 12 May 1988
Lifesaving
Issued 12 May 1988
Resolved
PROVIDE 2 ADDITIONAL ADULT AND ONE ADDITIONAL CHILD TYPE I PERSONAL FLOTATION DEVICE.
Condition: Unknown
Due 12 May 1988
Resolved 12 May 1988
Documentation
Issued 12 May 1988
Resolved
POST THE VESSEL'S CERTIFICATE OF INSPECTION AND STABILITY LETTER.
Condition: Unknown
Due 12 May 1988
Resolved 12 May 1988
Accommodation/Occupational Safety
Issued 12 May 1988
Resolved
FIT THE UPPER DECK RAILINGS WITH SOLID BULWARKS, CHAIN LINK FENCE OR EQUIVALENT.
Condition: Unknown
Due 12 May 1988
Resolved 12 May 1988