Passenger (Inspected) · Passenger Ship class · Built 1980s · USCG Heartland District (CGD-H) · Other hulls named SOUTHERN WAVE
SOUTHERN WAVE is a 1987 passenger vessel (inspected). The Coast Guard has recorded 40 inspections since 2000, most recently in November 2025, along with 68 deficiencies, 1 operational control and 1 casualty investigation in 2011.
Records from 2000 to 2025. Most recent: inspection, 18 November 2025.
- Built
- 1987
- Last inspected
- 18 November 2025
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 68 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2011
Identity
1093469
WDA2424
3034
Flag
UNITED STATES
367505980
Maury page id
psix-3034
Inspections, by type
…with no type recorded1
Years with a record
22 calendar years (2000–2025)
The 40 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)47.0 ft × 25.0 ft × 2.6 ft
Registered tonnagegross 20 / net 16
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMAC'S BOATBUILDERS OF GWYNN'S ISLAND · GWYNN'S ISLAND, VA, UNITED STATES · built 1987
Hull materialFRP (Fiberglass)
PropulsionAuxiliary Sail
Hull shapeShip
Hull configurationMonohull
Hailing portSOUTH PADRE ISLAND, TX
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 14 July 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it20 - Simplified, Gross Ton
16 - Simplified, Net Ton
16 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDN9871MMSI 367505980 · active · compulsorily equipped · granted 25 August 2023, expires 25 August 2033 · licensed under a name not among this hull’s recorded names (not shown)
WDF9520MMSI 367505980 · expired · compulsorily equipped · granted 6 October 2011, cancelled 11 December 2021
WDA2424MMSI not assigned · expired · compulsorily equipped · granted 4 October 2000, cancelled 4 December 2010
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 40
18 November 2025
Vessel Attendance · Examination of Repairs · Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8270335
12 May 2025
COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 8133396
18 February 2025
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 8080794
3 October 2024
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 8016162
23 July 2024
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7961986
2 February 2024
Administrative Inspection · In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7859683
7 December 2023
Hull Examination · Deficiency Check
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7836046
21 August 2023
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7771228
30 August 2022
Annual Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7547091
8 December 2021
Hull Examination
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7365903
30 September 2021
Annual Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7774291
9 June 2020
COI Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6973925
12 December 2019
Drydock Exam
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6874574
18 September 2019
Annual Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6816712
15 October 2018
Deficiency Check
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6562943
10 September 2018
Annual Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6547206
12 December 2017
Drydock Exam
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6430627
26 June 2017
Deficiency Check
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6212895
19 June 2017
Annual Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6182265
14 September 2016
Annual Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6000832
8 December 2015
Drydock Exam
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 5784427
6 October 2014
Annual Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 4997340
6 December 2011
Hull Examination · Deficiency Check
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 4203101
29 September 2011
Deficiency Check
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 4158188
15 September 2011
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 4143994
25 January 2011
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3932479
3 December 2009
Hull Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3644563
30 September 2008
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 3335058
2 June 2008
Hull Examination
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 3234115
9 October 2007
Annual Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 3078639
26 February 2007
Type not recorded
No type recorded · Station South Padre Island · USCG Heartland District (CGD-H) · Activity 2877497
6 October 2006
Administrative Inspection · Deficiency Check · Annual Inspection · Deadweight Survey
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 2794915
11 August 2006
Hull Examination
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 2748172
13 August 2004
Annual Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 2165210
6 August 2004
Hull Examination
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 2160922
9 July 2003
Annual Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 1842208
9 May 2002
Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 1614805
27 June 2001
Re-Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 1067766
29 September 2000
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1054642
28 June 2000
Initial Certification · Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1455897
Deficiency record · 68
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 June 2025
Resolved
Each ring life buoy must be marked with Type II retroreflective material (SOLAS Retroreflective Tape) IAW 46 CFR 164.018 . Vessels ring life buoy was found with unserviceable retroreflective tape.
46 CFR 185.604 (i)
46 CFR 164.018
IMO Resolution A.658(16).
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 June 2025
Resolved
Each life jacket must be marked with Type I retroreflective material approved in 46 CFR 164.018. Six life jackets where found with unserviceable retroreflective tape (SOLAS Retroreflective Tape). Reduce passenger count to 43 until rectified.
46 CFR 185.604 (h)
IMO RESOLUTION A.658(16) (5)
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 June 2025
Resolved
A serviceable adult life jacket must be provided for each person carried on board a vessel. Vessel had one torn life jacket. Reduce passenger count to 48 until rectified.
46 CFR 180.71 (a)
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 2 June 2025
Resolved
Portable extinguishers must be inspected and maintained in accordance with NFPA 10. Vessels 40 B:C fire extinguisher was waisted and unserviceable.
46 CFR 176.810(b)(1)
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 2 June 2025
Resolved
The intent of this part is to ensure that materials of each vessel are such as to provide for safe operation. Vessels stbd midship through hull valve is leaking.
46 CFR 177.01-5
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 June 2025
Resolved
This part is intended to provide a minimum standard of regulations for electrical installations. Vessel had an unapproved battery charge installed onboard.
46 CFR 183.05-30 (a)
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 2 June 2025
Resolved
A vessel must carry a first-aid kit approved under approval series 46 CFR 160.041. Expired components found in kit.
46 CFR 184.710
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 2 June 2025
Resolved
The intent of this part is to ensure that materials of each vessel are such as to provide for safe operation. Vessels port quarter has waisted core material. Repair vessel within one month.
46 CFR 177.01-5
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 June 2025
Resolved
This part is intended to provide a minimum standard of regulations for electrical installations and equipment that will result in a vessel that is reasonably safe from electrical fire. Vessel was found multiple electrical connections that where faulty.
46 CFR 183.05-30 (a)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 June 2025
Resolved
Auxiliary equipment shall be suitable in type and design for the purpose intended. The port bilge pump was found improperly mounted.
46 CFR 182.10-1
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 June 2025
Resolved
All equipment, including switches, fuses, etc., shall be of a type designed for the potential involved and so identified. Vessels distribution panel has multiple unlabeled breakers.
46 CFR 183.10-20 (i)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 February 2025
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection. Two bolts are not of proper length attaching the chain plates to the hull. Repair within one month.
46 CFR 177.100
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 February 2025
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection. Vessel has an insufficient preventative maintenance plan for the sails standing and running rigging in accordance with NAVIC 2-16. Submit PMP within one month.
46 CFR 177.100
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 23 July 2024
Resolved
Lakes, bays, and sounds route must carry three hand red flare distress signals approved in accordance with § 160.021 in subchapter Q of this chapter or other standard specified by the Commandant. Vessel did not have required flares onboard.
46 CFR 180.68 (b)(1)
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 23 July 2024
Resolved
Each vessel must be equipped with at least two operable portable battery lights. One portable light found onboard.
46 CFR 183.430
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 23 July 2024
Resolved
A vessel must be provided with bilge pumps in accordance with Table 182.520(a). Vessel did not have a portable hand bilge pump onboard during the inspection.
46 CFR 182.520 (a)
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 23 July 2024
Resolved
A vessel to which this subchapter applies may not be operated without having on board a valid U.S. Coast Guard Certificate of Documentation. No valid COD was onboard during the inspection.
46 CFR 176.100 (a)
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 23 July 2024
Resolved
On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate a high water level. MI found the high level alarms visible indicator OOC.
46 CFR 185.530 (a)
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 July 2024
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection. Sail rigging, mast, port, lower stay is cracked. Repair prior to using auxiliary sail.
46 CFR 177.100
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 July 2024
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection. Sail rigging, mast, stbd, lower wire rope not of proper size. Repair prior to using auxiliary sail.
46 CFR 177.100
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 July 2024
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection. Sail rigging, chain plates where found painted and unavailable for inspection. Remove chain plates and have inspected by the CG prior to using auxiliary sail.
46 CFR 177.100
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 July 2024
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection. Sail rigging, turn buckle, port, two mid stays found with the incorrect type for sail plan. Repair prior to using auxiliary sail.
46 CFR 177.100
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 23 July 2024
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. MI found the mast head light extinguished. The vessel is limited to daylight without reduced visibility operations.
46 CFR 183.420
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 2 February 2024
Resolved
Repairs or alterations to equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI. Vessel has an unapproved 120 Voltage AC system. All unapproved components shall be removed from the vessel no latter than Tuesday, February 13th.
46 CFR 176.700 (a)
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 August 2023
Resolved
Each connection to a conductor or terminal part of a conductor must be made within an enclosure. Vessel has multiple extension cords used for the 120 Volt AC system. System is to remain secured until it has passed inspection by C.G MI.
46 CFR 183.340 (g)(1)
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 August 2023
Resolved
Repairs or alterations to equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI. Vessel has an unapproved 120 Voltage AC system. System is to remain secured until it has passes inspection by a C.G MI.
46 CFR 176.700 (a)
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 21 August 2023
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection. Vessel has multiple holes in the deck and through the hull. Temporary repair completed. Complete repair during Dec22 DD.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 21 August 2023
Resolved
Lakes, bays, and sounds route must carry three hand red flare distress signals approved in accordance with 46 CFR 160.021 in subchapter Q of this chapter or other standard specified by the Commandant. Vessel did not have required flares onboard.
46 CFR 180.68 (b)(1)
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 21 August 2023
Resolved
A vessel must comply with the applicable requirements for any radio including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. Vessel had an expired station license, bridge to bridge, and no individual radio permit. Vessel must only operate with the approved hand held VHF radio. Rectify within 14 days
46 CFR 184.502
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 August 2023
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection. Vessel has an insufficient preventative maintenance plan for the sails standing and running rigging in accordance with NAVIC 2-16. Vessel is to use engine power only until rectified.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 21 August 2023
Resolved
Each vessel inspected and certificated under the provisions of this subchapter must be in full compliance with the terms of the COI. Vessel does not have a master with a Auxiliary Sail Endorsement on their MMC. Vessel is to use engine power only until rectified.
46 CFR 176.100 (b)
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 21 August 2023
Resolved
The Coast Guard will issue a medical certificate to a mariner meeting the medical and physical standards for merchant mariners. The master did not have a valid medical certificate on board during the inspection. The vessels master shall have a valid medical certificate to operate.
46 CFR 10.301
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 August 2023
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection. Vessels 12 Volt DC system has a broken bus bar near the aft battery compartment.
46 CFR 177.100
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 August 2023
Resolved
Each battery must secured to protect against shifting with the roll and pitch of the vessel, and free from exposure to water splash or spray. Batteries must be mounted in trays lined with, or constructed of, a material that is resistant to damage by the electrolyte.
Vessel does not have batteries in trays or strapped down are exposed to salt water.
46 CFR 183.350 (b)&(e)
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 August 2022
Resolved
Missing Sail plan: rectify prior to sail operations
Personnel › Certificates/Documents/Licenses › License, Master
Issued 19 June 2017
Resolved
liccense out of date
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 19 June 2017
Resolved
name of vsl on both side of hull
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 19 June 2017
Resolved
no proof of enrollment
Engineering › Fuel Oil Service System › Hose
Issued 15 September 2011
Resolved
Repair/Renew fuel hose connection to outboard engine. 46CFR182.15-40
Operations/Management › Drills/Instruction › Not Conducted
Issued 15 September 2011
Resolved
Conduct underway/under sail man overboard and fire drills in presence of CG inspector. 46CFR176.404
Deck/Cargo › Mooring/Anchoring › Mooring Line/Hawser
Issued 15 September 2011
Resolved
Renew fwd port side swage fitting for the fwd stay. 46CFR177.330
Deck/Cargo › Mooring/Anchoring › Mooring Line/Hawser
Issued 15 September 2011
Resolved
Replace and/or add cotter pins where missing on turnbuckles for rigging. 46CFR177.330
Documentation › Certificates/Documents › FCC SSL
Issued 15 September 2011
Resolved
Provide valid FCC radio station license. 46CFR80.13
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 15 September 2011
Resolved
Provide valid FCC safety certificate. Vessel is restricted to 1000 feet from shore until corrected. 47CFR80.903
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 15 September 2011
Resolved
Renew A-II fire extinguisher. 46CFR176.810
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 15 September 2011
Resolved
Renew/repair fwd netting where passengers have access. 46CFR176.402
Accommodation/Occupational Safety › Cooking Systems › LPG System Requirements
Issued 15 September 2011
Resolved
Secure LPG cylinder and position safety relief valveso it sischarges overboard. 46CFR184.240
Accommodation/Occupational Safety › Cooking Systems › LPG System Requirements
Issued 15 September 2011
Resolved
Provide /post warning label in accordance with ABYC A-I standard for LPG. 46CFR184.240
Accommodation/Occupational Safety › Cooking Systems › LPG System Requirements
Issued 15 September 2011
Resolved
Provide in line gauge for LPG cylinder. 46CFR184.240
Accommodation/Occupational Safety › Cooking Systems › LPG System Requirements
Issued 15 September 2011
Resolved
Secure grill. 46CFR184.220
Navigation › Piloting/Steering › Coast Guard Light List
Issued 15 September 2011
Resolved
Provide Coast Pilot and light list for area of operation. 46CFR184.420
Navigation › Piloting/Steering › Marine Charts
Issued 15 September 2011
Resolved
Provide approved navigation chart for area of operation. 46CFR184.420
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 15 September 2011
Resolved
Provide CG approved first aid kit. 46CFR184.410
Documentation › Markings/Placards › Lifejacket Placard
Issued 15 September 2011
Resolved
Post life jacket donning placard. 46CFR185.516
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 September 2011
Resolved
Make proper wire splices and provide non-releasable connectors at bus ties. 46CFR183.05-45
Operations/Management › Drug and Alcohol Testing › Testing, Random
Issued 15 September 2011
Resolved
Enroll crew members in a drug testing program. 46CFR16.
Accommodation/Occupational Safety › Cooking Systems › LPG System Requirements
Issued 15 September 2011
Resolved
Renew LPG fuel hose. 46CFR184.240
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 30 September 2008
Resolved
Renew Certificate of Documentation to show Coastwise trade.
Stability › Incline Test › General
Issued 6 October 2006
Resolved
Complete dead weight survey & submit stability calculations to MSC for issuance of a stability letter prior to 1Nov2006
Lifesaving › Lifebuoys › Approval
Issued 6 October 2006
Resolved
Replace ring buoy.
Fire Fighting › Fire Bucket › Availability
Issued 6 October 2006
Resolved
Place three 2.5 gallon fire buckets on board
Communications › Alarms/Indicators › Bilge Alarm
Issued 6 October 2006
Resolved
Prove proper operation of bilge high water alarm.
Navigation › Piloting/Steering › Marine Charts
Issued 6 October 2006
Resolved
Place charts of operating area on-board vessel.
Communications › Audible Communications › Horn/Whistle
Issued 6 October 2006
Resolved
Prove proper operation of sound producing device (horn).
Operations/Management › Drills/Instruction › Not Conducted
Issued 6 October 2006
Resolved
Complete required fire, man-overboard, flooding drills prior to carrying passengers
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 6 October 2006
Resolved
Place tide tables on-board.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 6 October 2006
Resolved
Replace 1st aid kit.
Documentation
Issued 28 June 2000
Resolved
Complete NVDC requirements and provide a copy of the Certificate of Documentation for the S/V Southern Wave to the Marine Safety Satellite Office in Brownsville, TX.
Casualty record · 1
19 April 2011Routine · role: Involved in a Marine Casualty · activity 3994491
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.