MAURY USCG vessel records Sign in
← All vessels

CORNELIA

CORNELIA is a 2000 freight ship. The Coast Guard has recorded 31 inspections since 2001, most recently in October 2016, along with 14 deficiencies and 9 operational controls.

Records from 2001 to 2016. Most recent: inspection, 17 October 2016.

Built
2000
Last inspected
17 October 2016
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9216597 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
COOK ISLANDS
—
Maury page id
psix-30434

Inspections, by type

…with no type recorded15
Years with a record 10 calendar years (2001–2016)
The 31 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it16807 - Convention (Subpart B), Gross Ton
7637 - Convention (Subpart B), Net Ton
32139 - Displacement, Ton
24516 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 31

17 October 2016 ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6023775
16 October 2016 Type not recorded
No type recorded · Station Duluth · USCG Great Lakes District (CGD-GL) · Activity 6023425
7 October 2016 Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6020048
5 January 2016 Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 5790964
3 November 2015 MARPOL Annex I Examination · ILO-147 Exam
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 5756989
3 November 2015 Type not recorded
No type recorded · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 5769002
29 October 2015 MARPOL Annex I Examination · Random ISPS/MTSA/PSC
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 5753197
19 October 2015 Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 5745950
20 June 2012 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4343905
18 June 2012 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4349128
17 June 2012 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4346648
4 December 2009 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3644825
21 July 2009 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3541413
6 October 2008 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3339594
18 July 2008 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3310955
6 November 2007 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3094099
26 July 2007 Random ISPS/MTSA-No PSC
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3008028
3 June 2007 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2950252
20 February 2007 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2874351
16 February 2007 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2873128
16 February 2007 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2873288
17 October 2006 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2802346
25 August 2006 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2759749
1 August 2006 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2732635
21 July 2006 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2720089
30 January 2006 ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 2575828
8 October 2003 Ballast Water Examination · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1923673
12 February 2003 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1743615
17 September 2002 Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1676714
23 April 2002 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1607997
12 September 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 293623

Deficiency record · 14

Construction/Loadline › Penetrations › Gasket
Issued 17 October 2016 Resolved
#5 hatch cover gasket missing section.
Action required: 705 - Other - as specified
Due 17 November 2016
Resolved 17 October 2016
Resolution: Corrected on the spot.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 17 October 2016 Resolved
Electrical Panel tied shut with nylon string.
Due 17 November 2016
Resolved 17 October 2016
Resolution: Corrected on the spot.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 17 October 2016 Resolved
Galley doors are tied back without automatic closure devices.
Due 17 November 2016
Resolved 17 October 2016
Resolution: Corrected on the spot.
Electrical › Electrical Distribution System (service) › Cable
Issued 17 October 2016 Resolved
Dead end cables found in BOSN locker along with extnsion cord being used in a permanent manner.
Action required: 705 - Other - as specified
Due 17 November 2016
Resolved 17 October 2016
Resolution: Flag submitted report clearing def.
Documentation › Logs/Records › Oil Record Book
Issued 3 November 2015 Resolved
The oil record book part I shall be completed when there is a discharge overboard or disposal otherwise of bilge water which has accumulated in the machinery space. After reviewing the sounding of the dirty water tank a significant change occured between 03OCT2015-04OCT2015. Vessel failed to document in the ORB the transfer of the dirty bilge water tank's contents to another location.
Action required: 705 - Other - as specified
Due 3 November 2015
Resolved 3 November 2015
Resolution: Vessel was detained due to inconsistencies found in the ORB prior to the current [name withheld] embarking. Since his embarkation the ORB was filled out properly.
Documentation › Safety Management System › Safety/Environmental Protection Policy
Issued 3 November 2015 Resolved
The ship shall comply with the policy requirements of the ISM code. Objective evidence discovered in an expanded MARPOL exam revealed that the company/vessel failed to fully implement the requirements of the ISM Code through the Safety Management System as noted by deficiencies found during the MARPOL Exam.
Action required: 15 - Rectify deficiencies by next port
Due 5 November 2015
Resolved 5 November 2015
Resolution: Vessel was detained due to inconsistencies found in the ORB prior to the current Chief Engineer embarking. Since his embarkation the ORB was filled out properly as per the vessel's safety management system.
Fire Fighting › Structural - Main Vertical Zones › General
Issued 29 October 2015 Resolved
0750-Fire Prevention-Fire doors in main vertical zone bulkheads and stationary enclosures shall be self closing and be capable of closing against an angle of inclination of up to 3.5 degrees opposing closure. The ladder well door on the main deck was incapable of closing completely.-SOLAS 74(01 CONS)Chp. II-2 Reg. 30.4.1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 October 2015
Resolved 29 October 2015
Resolution: A-60 self closing door was adjusted and fixed during exam.
Lifesaving › Lifebuoys › Serviceable
Issued 29 October 2015 Resolved
0650-Lifebuoys-Before the ship leaves port and at all times during the voyage all life saving appliances shall be in working order and ready for immediate use. The starboard side lifebuoy forward of the superstructure is unserviseable.-SOLAS 74(14 CONS)Chp. III Reg. 20.2
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 October 2015
Resolved 29 October 2015
Resolution: Lifebuoy was replaced.
Construction/Loadline › Markings › Load Line Mark
Issued 29 October 2015 Resolved
1299-Other(Load Lines)-Details of marking (load lines) the ring, lines, and letters shall be painted in a white or yellow on a dark ground or in black on a light ground. The plimsoll mark is not painted and not visable.-ICLL Annex I/8
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 29 October 2015
Resolved 17 October 2016
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder Head
Issued 29 August 2008 Resolved
During transit outbound from SECBALT AOR vessel's ME began to overheat. Vsl anchored in Annapolis Anchorage and made repairs. Class to attest to satisfactory repair/operation prior to departure from next US port (SEC HR zone). SOLAS 74/78 amended (97 ed) I/11
Action required: 705 - Other - as specified
Resolved 30 August 2008
Resolution: Received satisfactory class report attesting to the cause and repair of the M/E
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 28 August 2008 Resolved
The rudder angle indicator is unable to go to 35 degrees on the port side. The max it will go to is 32 degrees. Class to attest to proper operation of the rudder. SOLAS 74/78 (97 cons.) ch. II-1/29.3.2
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 6 October 2008
Resolution: Rudder operation normal as per Class attestation.
Engineering › Sea-water System (primary cooling) › Piping
Issued 28 August 2008 Resolved
There is a spot weld on the salt water inlet cooling line of the #2 generator. This repair is leaking. Class to attest to repairs. SOLAS74/78 (97 cons.) Ch. I/11
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 6 October 2008
Resolution: New section of pipe installed.
Lifesaving
Issued 12 September 2001 Resolved
Life jackets missing personal marker lights. Provide reciept of approved lights prior to 14 SEP 01.
Condition: Unknown
Due 14 September 2001
Resolved 23 April 2002
Resolution: MSO PHILADELPHIA CONDUCTED DEFICIENCY FOLLOW UP EXAM AND CLEARED DEFICIENCY.
Fire Fighting
Issued 12 September 2001 Resolved
Two scba units on board. 4 air bottles on board. 1 bottle has less than 50 bar. Fire plan requires 3 bottles per unit. Provide receipt for service (one) and procurement of 2 bottles prior to 14 SEP 01.
Condition: Unknown
Due 14 September 2001
Resolved 26 April 2002
Resolution: Faxed copy of receipt to MSO Philadelphia.