HAWAIIAN CHIEFTAIN

HAWAIIAN CHIEFTAIN is a 1987 passenger vessel (inspected). The Coast Guard has recorded 86 inspections since 1990, most recently in February 2024, along with 134 deficiencies and 4 casualty investigations between 2010 and 2018.

Records from 1990 to 2024. Most recent: inspection, 1 February 2024.

Built
1987
Last inspected
1 February 2024
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDP4422
304631
Flag
UNITED STATES
368281000
Maury page id
psix-304631

Inspections, by type

…with no type recorded11
Years with a record 30 calendar years (1990–2024)
The 86 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)64.9 ft × 21.8 ft × 8.3 ft
Registered tonnagegross 58 / net 52
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderISLAND TRADER MARINE · LAHAINA, HI, UNITED STATES · built 1987
Hull materialSteel
PropulsionAuxiliary Sail
Hull shapeSail (Distinct Keel)
Hull configurationMonohull
Hailing portLAHAINA, HI
Trade endorsementsCoastwise, unrestricted, Recreational, Registry
DocumentationValid · issued 8 June 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it52 - Simplified, Net Ton
58 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDP4422MMSI 368281000 · active · compulsorily equipped · granted 22 February 2024, expires 22 February 2034
WDC8751MMSI 367092520 · expired · compulsorily equipped · granted 8 December 2015, cancelled 18 April 2026
WDC7668MMSI 366011000 · expired · compulsorily equipped · granted 3 November 2005, cancelled 8 July 2006
WDC5618MMSI 303409000 · expired · compulsorily equipped · granted 21 May 2005, cancelled 25 July 2015 · licensed under a name not among this hull’s recorded names (not shown)
WAA7737MMSI not assigned · expired · compulsorily equipped · granted 18 May 1995, cancelled 23 July 2005
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

MADELINE Commercial Fishing Vessel · MISLE 200358 · 5 December 1995 · activity 131684

Inspection history · 86

1 February 2024 Special Consideration
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7859453
10 August 2021 COI Inspection · Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7281986
11 September 2019 Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6981141
18 June 2019 Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6713790
27 November 2018 Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 6587673
13 October 2018 Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6555271
28 September 2018 Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6579924
27 September 2018 Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6550980
26 September 2018 Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 6550690
21 September 2018 Annual Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6547192
19 September 2018 Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 6544366
9 March 2018 Internal Structural Exam · Administrative Inspection · Damage Survey
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6371147
9 March 2018 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6453986
11 July 2017 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6274733
9 June 2017 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 6170811
17 November 2016 Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 6043050
9 September 2016 Annual Inspection · Administrative Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 5994453
14 September 2015 Deficiency Check · COI Inspection · Simplified Stability Test
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 5720421
18 August 2015 Inclining Experiment
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 5720461
18 August 2014 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4959025
7 May 2012 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4306716
22 September 2011 Annual Inspection · Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4150710
9 September 2011 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4132852
12 October 2010 Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3879006
23 September 2010 Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3827367
16 January 2010 In-Service Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3664898
15 January 2010 Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3627675
1 October 2008 Annual Inspection · Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3335628
16 June 2008 Administrative Inspection · Excursion Permit
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3239108
16 October 2007 Type not recorded
No type recorded · Station Tillamook Bay · USCG Northwest District (CGD-NW) · Activity 3081315
9 October 2007 Deficiency Check · COI Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3041919
10 September 2007 Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3052151
16 June 2007 Annual Inspection · Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2962978
13 January 2007 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2858898
10 February 2006 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2589117
2 November 2005 Deficiency Check
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2526257
9 September 2005 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2487937
26 July 2005 Re-Inspection
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2440166
26 October 2004 Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2228929
14 October 2004 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2213406
4 August 2004 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2150715
24 May 2004 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2097387
19 April 2004 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2047545
30 April 2003 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1779847
11 February 2003 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1743262
29 January 2003 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1736931
30 December 2002 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1724302
23 December 2002 Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 1722463
20 June 2002 Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1633950
7 June 2002 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1627886
3 April 2002 Annual Inspection · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1493142
21 February 2001 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1373336
26 January 2000 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1393319
2 April 1999 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 786777
29 March 1999 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1388771
5 January 1999 Hull Examination · Damage Survey
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1446721
3 January 1999 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 109774
30 March 1998 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 788188
17 February 1998 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1406259
20 January 1998 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1404504
4 February 1997 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1385885
14 January 1997 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1398591
7 May 1996 Deficiency Check · Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1456363
22 February 1996 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 885838
16 February 1996 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1434362
5 December 1995 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 131684
30 November 1995 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1394428
1 August 1995 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 874830
22 May 1995 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1181049
17 April 1995 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1166040
31 January 1995 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1409230
2 December 1994 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 857278
29 September 1994 Inclining Experiment
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1175299
15 July 1994 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 213543
31 May 1994 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1171807
6 April 1994 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 857770
8 March 1994 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1165180
16 August 1993 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 845914
24 June 1993 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 843742
23 December 1992 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 826547
18 May 1992 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1259166
20 April 1992 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 956870
10 March 1992 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1261328
8 March 1991 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 997684
2 March 1990 Plan Review "T" Boat · Hull Examination · Initial Certification
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1228362
2 March 1990 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1233212

Deficiency record · 134

99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 September 2018 Resolved
Prior to carrying passengers underway, replace the damaged port propeller to the satisfaction of attending USCG marine inspector. 46 CFR 182.100
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 October 2018
Resolution: Replacement-in-kind of bronze propeller: D.30" x P.22" LH x 4 blade
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 September 2018 Resolved
Vessel has no substantive written record of maintenance done to the sail rigging. NVIC 02-16 recommends a complete rig survey be done by a third party surveyor if there is no written preventive maintenance record for the rig. Inspection of the rigging shows that the crew is conducting regular repairs and maintenance, just not recording the results. Complete survey within 90 days provide copy to [name withheld].
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 November 2018
Resolved 31 October 2018
Resolution: Received third party rigging survey attached in the document section of activity 6555271.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 21 September 2018 Resolved
Provide a prevenatative maintenenace plan to include general description, maintenance schedule and key rigging component inventory. Plan should include all components indentified in USCG NVIC 02-16.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 October 2018
Resolved 27 November 2018
Resolution: Company Rep e-mailed copy of draft rigging maintenance plan.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 21 September 2018 Resolved
Provide a third party rigging survey to attest to the current condition of the rig. Recommendations for continued service and to qualify all conditions (unsat) identified in the 12JULY17 rig survey report and letter from former vessel [name withheld] dated 11/17, approximately 50% of items were left uncorrected and no corrective action plan was on board. Provide prior to sailing with passengers. 46 CFR 176.700
Action required: 705 - Other - as specified
Due 25 September 2018
Resolved 26 September 2018
Resolution: Cleared CG835 issued new CG835 to require a third party survey in not more than 90 days.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 September 2018 Resolved
Provide a portable magazine locker made of 1/8" metal and lined with wood meeting the construction requirements in 46 CFR 160.38.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 October 2018
Resolved 27 November 2018
Resolution: Received photos from Historic Seaport Rep showing completed magizine locker installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 September 2018 Resolved
Provide a life jacket placard for for each type of life jacket provided on board. 46 CFR 185.516
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 October 2018
Resolved 27 November 2018
Resolution: Life jacket donning placard is onboard.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 21 September 2018 Resolved
Vessel must be operated within the limitations of the amended COI dated 19SEP2018. Deficiency to remain open until delivery of signed amended COI.
Action required: 705 - Other - as specified
Due 22 October 2018
Resolved 27 November 2018
Resolution: Vessel has current COI onboard.
Accommodation/Occupational Safety › Occupational Safety › Receptacle Outlet
Issued 25 September 2017 Resolved
Electrical outlet in the forward crew accommodation space overhead requires protective cover.
Due 9 October 2017
Resolved 26 September 2017
Resolution: Cover installed as directed.
Communications › Alarms/Indicators › Bilge Alarm
Issued 25 September 2017 Resolved
Port shaft high level alarm inoperable.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 September 2017
Resolution: Witnessed port shaft high level alarm woking properly with audible and visual indication at the operating station.
Communications › Alarms/Indicators › Bilge Alarm
Issued 25 September 2017 Resolved
Starboard shaft high level alarm inoperable.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 September 2017
Resolution: Witnessed starboard shaft high level alarm woking properly with audible and visual indication at the operating station.
Fire Fighting › Fire Bucket › Quantity
Issued 25 September 2017 Resolved
Vessel only has one (1) bucket for fire fighting and is required three (3) total.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 September 2017
Resolution: Verified (2) new fire buckets appropriately labeled and on board.
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 September 2017 Resolved
Secure dead end wires in potable water tank space.
Due 9 October 2017
Resolved 26 September 2017
Resolution: Witnessed dead end wires in potable water space were properly connected to the port and starboard high level alarms.
Fire Fighting › Fire Pumps › Pressure
Issued 25 September 2017 Resolved
Fixed fire pump inoperable. Proper operation of fixed fire pump must be witnessed by attending Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 September 2017
Resolution: Witnessed proper operation of the vessel's fixed fire pump.
Engineering › Bilge Water Management System › Pump
Issued 25 September 2017 Resolved
Fixed bilge system inoperable. Operation of the fixed bilge system must be witnessed by attending Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 September 2017
Resolution: Witnessed proper operation of the vessel's fixed bilge pump/system.
Lifesaving › Inflatable Liferafts › Not on Board
Issued 9 June 2017 Resolved
Provide 02 inflatable life rafts. Until this item is complete, total number of persons allowed on board is reduced to 30.
Action required: 705 - Other - as specified
Due 17 June 2017
Resolved 13 September 2017
Resolution: Received life raft servicing reports. All sat.
Communications › Alarms/Indicators › Bilge Alarm
Issued 14 September 2015 Resolved
Permanently affix bilge high level alarm within focsle.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 October 2015
Resolved 17 September 2015
Resolution: Bilge high level alarm within focsle has been permanently affixed.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 14 September 2015 Resolved
02 Adult Type I PFDs are missing and needs to be installed.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 October 2015
Resolved 17 September 2015
Resolution: 02 Adult Type I PFDs have been added to the vessel.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 14 September 2015 Resolved
Replace lagging on port marine engine exhaust.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 October 2015
Resolved 17 September 2015
Resolution: Lagging on port marine engine exhaust has been replaced.
Engineering › Fuel Oil Service System › Valve, Solenoid
Issued 18 August 2014 Resolved
Provide shut down of port main engine at the main pilothouse control IAW 46 CFR 184.620(b).
Due 19 September 2014
Resolved 18 September 2014
Resolution: Installed shut down at operating station for Port Engine.
Engineering › Sea-water System (primary cooling) › Piping
Issued 18 August 2014 Resolved
Provide hose clamps on raw water hose leading to main generator. 46 CFR 182.410(d)(4)
Due 27 August 2014
Resolved 19 August 2014
Resolution: New clamps placed on hose, corrected on site.
Engineering › Fuel Oil Service System › Hose
Issued 22 September 2011 Resolved
HO01. PRIOR TO SAILING REPLACE FO HOSE, W/ SAE-J1942 APPROVED TYPE, ON PORT SIDE MAIN ENGINE TO SATISFACTION OF THE MARINE INSPECTOR. 46CFR182.720
Action required: 705 - Other - as specified
Due 22 October 2011
Resolved 7 October 2011
Engineering › Lubricating Oil Service System › Hose
Issued 22 September 2011 Resolved
HO02. PRIOR TO SAILING REPLACE FO HOSE ON RETURN LINE W/ SAE-J1942 APPROVED TYPE, ON GENERATOR TO SATISFACTION OF THE MARINE INSPECTOR. 46CFR182.720
Action required: 705 - Other - as specified
Due 22 October 2011
Resolved 7 October 2011
Construction/Loadline › Structures › Superstructure
Issued 22 September 2011 Resolved
HO03. MAKE OVERHEAD VAPOR TIGHT IN THE ENGINE ROOM TO THE SATISFACTION OF THE MARINE INSPECTOR PRIOR TO SAILING. 46CFR177.405(E)
Action required: 17 - Rectify deficiencies prior to departure
Due 22 October 2011
Resolved 7 October 2011
Electrical › Electrical Distribution System (service) › Wiring
Issued 22 September 2011 Resolved
HO04. REMOVE DEAD END WIRES IN THE ENGINE ROOM TO THE SATISFACTION OF THE MARINE INSPECTOR. 46CFR183.340
Action required: 705 - Other - as specified
Due 22 October 2011
Resolved 7 October 2011
Communications › Radio Communications › EPIRB
Issued 22 September 2011 Resolved
HO05. REPLACE HYDROSTATIC RELEASE ON EPIRB W/ APPROVED TYPE TO THE SATISFACTION OF THE MARINE INSPECTOR PRIOR TO SAILING. CURRENT HYDROSTATIC RELEASE NOT SUITED FOR EPIRB. 46CFR180.64
Action required: 17 - Rectify deficiencies prior to departure
Due 22 October 2011
Resolved 7 October 2011
Fire Fighting › Portable CO2 Fire Extinguisher › Condition
Issued 22 September 2011 Resolved
HO06. REPLACE TWO B-II PORTABLE FIRE EXTINGUISHERS TO THE SATISFACTION OF THE MARINE INSPECTOR. OR HAVE ORIGINAL EXTINGUISHER RECERTFIED/RESERVICED TO COMPLY WITH NFPA 10. 46CFR181.500
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 October 2011
Resolved 23 September 2011
Engineering › Shafting/Propeller Arrangements › Propeller (controllable pitch)
Issued 9 September 2011 Resolved
Port propeller blades dented by impact with deadhead. Blades are off prop to be repaired. Provide evidence of successful repairs once completed.
Due 9 October 2011
Resolved 13 September 2011
Resolution: Propellers welded and faired. Vessel emailed pictures of repaired propeller.
Electrical › Electrical Distribution System (service) › Shore Connection Box
Issued 28 September 2010 Resolved
Provide/Install a proper electrical knob for the shore power panel 46 CFR 183.01-15
Condition: Damaged By Earlier Event
Due 15 October 2010
Resolved 12 October 2010
Engineering › Fuel Oil Service System › Valve
Issued 28 September 2010 Resolved
Provide proper valve handle for the generator fuel return line. 46 182.20-40
Condition: Damaged By Earlier Event
Due 15 October 2010
Resolved 12 October 2010
Documentation › Markings/Placards › Warning Signs
Issued 1 October 2008 Resolved
Provide signage marking location of Emergency Fuel Shut-Off (Should be viewable on main deck). 46 CFR 185.608
Condition: Improper/Lack of Maintenance
Due 1 November 2008
Resolved 8 October 2008
Resolution: Vessel owner procured sign.
Engineering › Fuel Oil Service System › Ventilation
Issued 1 October 2008 Resolved
Replace flame screen on all four fuel vent goose necks. Flame screen must be 30 X 30 mesh, corrosion resistant metallic material. 46 CFR 182.450.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 October 2008
Resolution: Vessel owner installed new flame screens.
Engineering › Sea-water System (primary cooling) › Piping
Issued 1 October 2008 Resolved
Replace bell reducer pepe fitting on shaft cooling supply line of the aft raw water manifold. 46 CFR 182.710
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 October 2008
Resolution: Vessel owner replaced fitting.
Electrical › Electrical Distribution System (service) › Cable
Issued 1 October 2008 Resolved
Remove all dead-end cable in engine room, including three cables extending from SSDG control box. 46 CFR 183.340
Due 1 November 2008
Resolved 8 October 2008
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 1 October 2008 Resolved
Install protective guard over drive pulley belt on port side fwd exhaust fan in engine room. 46 CFR 177.960
Condition: Improper/Lack of Maintenance
Due 1 November 2008
Resolved 8 October 2008
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 1 October 2008 Resolved
Install protective guard over squirrel cage blower discharge in port side engine room overhead. 46 CFR 177.960
Due 1 November 2008
Resolved 8 October 2008
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 1 October 2008 Resolved
Make all electrical outlets in the engineroom weather-tight / splash-proof. 46 CFR 183.210
Due 1 November 2008
Resolved 8 October 2008
Engineering › Fuel Oil Service System › Hose
Issued 1 October 2008 Resolved
Replace fuel oil return hose on stbd main diesel engine. Hose must be SAE J1942 compliant. 46 CFR 182.720
Due 1 November 2008
Resolved 8 October 2008
Engineering › Fuel Oil Service System › Pump
Issued 1 October 2008 Resolved
Re-attach electric fuel pump on stbd main diesel engine (missing bolt). 46 CFR 182.100
Due 1 November 2008
Resolved 8 October 2008
Electrical › Electrical Distribution System (service) › Panelboard
Issued 1 October 2008 Resolved
Re-insert conduit into connector fittings (stuffing tubes) on SSDG and the main switch board panel. 46 CFR 183.340
Due 1 November 2008
Resolved 8 October 2008
Electrical › Lighting (service) › Lighting Fixture
Issued 1 October 2008 Resolved
Replace missing cover oc light fixture above the port main diesel engine. 46 CFR 183.410
Due 1 November 2008
Resolved 8 October 2008
Engineering › Fuel Oil Service System › Filter
Issued 1 October 2008 Resolved
Install solid plugs in Racor drain valves located on each MDE fuel supply. 46 CFR 182.455
Due 1 November 2008
Resolved 8 October 2008
Electrical › Electrical Distribution System (service) › Panelboard
Issued 1 October 2008 Resolved
Install covers over openings in electrical panels P201 and P101 in engine room to restore splash/drip proof construction (openings are from removal of original latches). 46 CFR 183.210
Due 1 November 2008
Resolved 8 October 2008
Electrical › Electrical Distribution System (service) › Panelboard
Issued 1 October 2008 Resolved
Remove vocer and clean/remove corrosion/salt from main electrical distribution panel P201. 46 CFR 183.210
Due 1 November 2008
Resolved 8 October 2008
Electrical › Electrical Distribution System (service) › Panelboard
Issued 1 October 2008 Resolved
Replace missing circuit index for main electrical distribution panel P201. 46 CFR 183.220
Due 1 November 2008
Resolved 8 October 2008
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 1 October 2008 Resolved
Remove all excess waste oil from the engine room bilges. 46 CFR 176.830
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 October 2008
Construction/Loadline › Structures › Ventilators
Issued 9 October 2007 Resolved
Repair wasted port engineroom vent.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 November 2007
Resolved 12 October 2007
Resolution: Weld repaired hole in ventilator.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 9 October 2007 Resolved
Provide and place onboard light list.
Action required: 705 - Other - as specified
Due 10 November 2007
Resolved 12 October 2007
Resolution: Light list downloaded and placed onboard. New hard copy will be purchased when they become available.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 9 October 2007 Resolved
Electrical box cover on sewage pump motor missing, replace.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 November 2007
Resolved 12 October 2007
Resolution: Installed cover.
Stability › Watertight Integrity › General
Issued 9 October 2007 Resolved
Install alarm switch for watertight tight door in aft bulkhead of main hold.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 November 2007
Resolved 12 October 2007
Resolution: Switch installed and tested sat.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 9 October 2007 Resolved
Provide and place onboard 25 adult lifejackets to replace failed lifejackets. Total passenger count reduced to 28 until lifejackets are replaced.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 November 2007
Resolved 12 October 2007
Resolution: New lifejackets placed on-board and properly marked.
Engineering › Diesel Engine (auxiliary) › Pump, High Pressure (fuel injection)
Issued 9 October 2007 Resolved
Repair/replace leaking high pressure injector fuel line on generator prime mover.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 November 2007
Resolved 12 October 2007
Resolution: Replaced gasket and tested, sat.
Engineering › Bilge Water Management System › Eductor
Issued 7 September 2007 Resolved
Need follow-up testing of bilge water system to be witnessed by attending marine inspector during next annual exam in October 2007. Prove proper operation of bilge suction repair/replacement
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 October 2007
Resolved 9 October 2007
Resolution: Tested bilge pumping system, sat.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 16 June 2007 Resolved
No proof of enrollment available on board. owner will fax to Portland office.
Condition: Unknown
Due 16 July 2007
Resolved 19 June 2007
Resolution: Main office faxed list of crew enrolled.
Electrical › Electric Generation Source (service) › Generator
Issued 16 June 2007 Resolved
Ships service generator inoperable due to heat exchanger failure on prime mover. Vessel has electric fire pump. Prove proper operation of generator and installed fire pump prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 July 2007
Resolved 19 June 2007
Resolution: Vessel received heat exchanger and installed. Tested installed fire pump, Sat
Electrical › Electrical Distribution System (service) › Cable
Issued 16 June 2007 Resolved
Secure loose wire on water heater. Wire clamp is missing on the water heater service connection allowing wire to chafe on the metal box.
Action required: 705 - Other - as specified
Due 16 June 2007
Resolved 19 June 2007
Resolution: Installed clamp securing wires.
Lifesaving › Lifejacket/PFD (Type II) › Condition
Issued 16 June 2007 Resolved
2 life jackets failed due to cracks in outer jacket. vessel has 50 onboard and requires 53. Passengers limited to not more than 50 until corrected.
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 July 2007
Resolved 19 June 2007
Resolution: Three new lifejackets placed on board.
Communications › Radio Communications › EPIRB
Issued 16 June 2007 Resolved
EPIRB Battery out of date. Hydro static release out of date. Complete prior to voyage on high seas. outside of 3NM.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 July 2007
Resolved 29 June 2007
Resolution: Purchased EPIRB battery and hydro release, placed on board.
Electrical › Electrical Distribution System (service) › Cable
Issued 16 June 2007 Resolved
Replace missing cover on lighting fixture in engine room, eliminate splice in wire servicing light.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 July 2007
Resolved 19 June 2007
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 16 June 2007 Resolved
Provide insulation for exposed exhaust piping on generator.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 July 2007
Resolved 19 June 2007
Resolution: Wrapped pipe with fiberglass tape.
Engineering › Bilge Water Management System › Strainer
Issued 16 June 2007 Resolved
Replace all corroded bilge suction strainers/foot valves. Complete to the satisfaction of the attending CG Marine Inspector, prior to end of dry-dock in September of 2007.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2007
Resolved 17 September 2007
Electrical › Electrical Distribution System (service) › Cable
Issued 16 June 2007 Resolved
Provide clamp for wire in light fixture in space under the great cabin.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 July 2007
Resolved 19 June 2007
Deck/Cargo › Cargo Stowage › General
Issued 13 January 2007 Resolved
Remove all class 1.1 or 1.2 explosives (black powder) from the vessel. 46 CFR 147.40
Due 13 January 2007
Resolved 13 January 2007
Deck/Cargo › Cargo Stowage › General
Issued 13 January 2007 Resolved
Install wire rope tie downs to gun powder box.
Action required: 705 - Other - as specified
Due 25 January 2007
Resolved 24 January 2007
Resolution: Wire rope was installed
Deck/Cargo › Cargo Stowage › General
Issued 13 January 2007 Resolved
Mark gun powder box IAW with 46 CFR 160.038-5
Action required: 705 - Other - as specified
Due 25 January 2007
Resolved 24 January 2007
Resolution: Marking was IAW 46 CFR 160.038-5
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 2 November 2005 Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, CONDUCT NEW TO ZONE INSPECTION, TO INCLUDE UNDERWAY DRILLS.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 December 2005
Resolved 22 February 2006
Resolution: Annual inspection completed, including underway drills.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 2 November 2005 Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE PROVIDE PROOF OF CURRENT COD, FCC CERTIFICATES, DRUG TESTING PROGRAM AND EPIRB REGISTRATION.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 December 2005
Resolved 10 February 2006
Resolution: Verified current documents.
Lifesaving › Inflatable Buoyant Apparatus › Not on Board
Issued 26 July 2005 Resolved
INSTALL LIFE RAFTS WITH PROPER ATTACHMENTS.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 September 2005
Resolved 2 November 2005
Resolution: LIFE RAFTS INSTALLED PROPERLY.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 26 July 2005 Resolved
CONDUCT UNDERWAY MAN OVERBOARD, FIRE DRILLS AND UNDERWAY OPERATIONS.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 September 2005
Resolved 2 November 2005
Resolution: SEE NEW REQUIREMENT.
Documentation › Certificates/Documents › FCC SSL
Issued 26 July 2005 Resolved
PROVIDE PROOF OF THE FOLLOWING CURRENT DOCUMENTS - FCC SAFETY RADIO TELEPHONY, WASTE MANAGEMENT PLAN, DRUG TESTING PROGRAM, ETC.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 September 2005
Resolved 2 November 2005
Resolution: SEE NEW REQUIREMENT.
Fire Fighting › Fire Pumps › Arrangement
Issued 26 July 2005 Resolved
PROVE PROPER OPERATION OF ALL VESSEL SYSTEMS INCLUDING FIRE FIGHTING, PROPULSION , STEERING, BILGE PUMPS AND ALARMS, NAV GEAR, ETC.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 September 2005
Resolved 2 November 2005
Resolution: FIRE AND BILGE PUMP, PROPULSION, STEERING, ALARMS, ETC. TESTED SAT.
Electrical › Electric Generation Source (service) › Generator
Issued 26 July 2005 Resolved
PROVIDE BELT AND PULLEY COVER FOR THE GENERATOR.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 September 2005
Resolved 2 November 2005
Resolution: COVER INSTALLED.
Engineering › Fuel Oil Service System › Piping
Issued 4 August 2004 Resolved
Secure fuel oil leak on return line for generator.
Due 10 August 2004
Resolved 11 August 2004
Electrical › Electrical Distribution System (service) › Wiring
Issued 4 August 2004 Resolved
Make fitting watertight for wiring through forward collision bulkhead.
Due 10 August 2004
Resolved 11 August 2004
Electrical › Electrical Distribution System (service) › Wiring
Issued 4 August 2004 Resolved
Make fittings watertight for wiring through aft watertight bulkhead under captain's cabin.
Due 10 August 2004
Resolved 11 August 2004
Construction/Loadline › Penetrations › Valve Flange
Issued 4 August 2004 Resolved
Blank off unused through hull valve-fitting under main berthing space on centerline.
Due 10 August 2004
Resolved 11 August 2004
Electrical › Lighting (service) › Lighting Fixture
Issued 4 August 2004 Resolved
Properly mount light fixture in crawl space under captain's cabin.
Due 10 August 2004
Resolved 11 August 2004
Engineering › Bilge Water Management System › Interface Detector
Issued 4 August 2004 Resolved
Properly mount bilge float switch in crawl space under captain's cabin.
Due 10 August 2004
Resolved 11 August 2004
Construction/Loadline › Hull › Side Shell
Issued 4 August 2004 Resolved
Prove watertight integrity of all port lights.
Due 10 August 2004
Resolved 11 August 2004
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 4 August 2004 Resolved
Provide new tail shafts for both main engines.
Action required: 705 - Other - as specified
Due 10 September 2004
Resolved 14 October 2004
Operations/Management › Drug and Alcohol Testing
Issued 19 April 2004 Resolved
Complete DAPI audit.
Action required: 705 - Other - as specified
Due 19 May 2004
Resolved 24 May 2004
Electrical › Electrical Distribution System (service)
Issued 19 April 2004 Resolved
Provide cover in way of hole in fuse panel located stbd side aft in engine room. LEGACY COMPONENT DESC: Panelboard
Action required: 705 - Other - as specified
Due 19 May 2004
Resolved 24 May 2004
Engineering › Lubricating Oil Service System
Issued 19 April 2004 Resolved
Provide proof oil filter hoses in way of port and stbd engines meet J-1942 standards IAW 46 CFR 182.720 LEGACY COMPONENT DESC: Hose
Action required: 705 - Other - as specified
Due 19 May 2004
Resolved 24 May 2004
Communications › Alarms/Indicators
Issued 19 April 2004 Resolved
Provide seperate indicator light for high water bilge alarm in way of focsle. LEGACY COMPONENT DESC: Bilge Alarm
Action required: 705 - Other - as specified
Due 19 May 2004
Resolved 24 May 2004
Accommodation/Occupational Safety › Occupational Safety
Issued 19 April 2004 Resolved
Install machinery guard in way of stbd engine. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Action required: 705 - Other - as specified
Due 19 May 2004
Resolved 24 May 2004
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 19 April 2004 Resolved
Remove expired items from first aid kit.
Due 19 April 2004
Resolved 19 April 2004
Lifesaving
Issued 19 April 2004 Resolved
Renew expired batteries in way of floating water light.
Due 19 April 2004
Resolved 19 April 2004
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 19 April 2004 Resolved
Provide life line in way of life ring.
Due 19 April 2004
Resolved 19 April 2004
Accommodation/Occupational Safety › Occupational Safety
Issued 23 December 2002 Resolved
Noted numerous containers of flammable and conbustible materials (paints, solvents, thinner, etc...) being stored in the fore peak storage area. Vsl rep. indicated that it is only stored there at this time while the vsl is in the yard. Issued rqmt to remove items from fore peak.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 January 2003
Resolved 29 January 2003
Resolution: Cleared out materials from fore peak.
Construction/Loadline › Structures
Issued 23 December 2002 Resolved
Dogs for QAWTD between engine room and storage area below galley had been modified, removing the quick acting device joining the dogs on both sides of the door, leaving half of the door unsecured. Issued rqmt to provide means to secure WTD between engine room and storage area. LEGACY COMPONENT DESC: Machinery Space Opening
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 January 2003
Resolved 29 January 2003
Resolution: WTD was secured. Dogs worked properly.
Stability
Issued 23 December 2002 Resolved
Noted during examination that below deck bilge spaces were stuffed with excess materials. Discussed with vsl rep. that the vessel was probably in violation of its stability letter. Issued rqmt to remove the excess stores and materials from vsl being stowed in below deck spaces.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 January 2003
Resolved 29 January 2003
Resolution: Corrected
Accommodation/Occupational Safety › Medical/First Aid
Issued 3 April 2002 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Due 3 April 2002
Resolved 3 April 2002
Resolution: Corrected on the spot.
Construction/Loadline › Structures
Issued 3 April 2002 Resolved
Replace broken port hole starboard side forward. LEGACY COMPONENT DESC: Windows
Action required: 705 - Other - as specified
Due 3 May 2002
Resolved 7 June 2002
Resolution: Port hole glass renewed.
Fire Fighting › Fire Pumps
Issued 3 April 2002 Resolved
Repair leaking seal on fire pump. LEGACY COMPONENT DESC: Gland Sealing
Action required: 705 - Other - as specified
Due 3 May 2002
Resolved 14 June 2002
Resolution: Seal repaired and tested to the satisfaction of attending marine inspector.
Communications › Radio Communications
Issued 3 April 2002 Resolved
Post emergency broadcast placard by radio located on deck. LEGACY COMPONENT DESC: Broadcast Placard
Due 3 April 2002
Resolved 3 April 2002
Documentation
Issued 21 February 2001 Resolved
Correct the vessel's Certificate of Documentation to show the vessel's actual length.
Condition: Unknown
Due 21 March 2001
Resolved 3 April 2002
Resolution: Certificate of Documentation has correct vessel length.
Lifesaving
Issued 21 February 2001 Resolved
Renew 406 EPIRB hydrostatic release.
Condition: Unknown
Due 25 February 2001
Resolved 25 February 2001
Documentation
Issued 21 February 2001 Resolved
Have on board and maintain "sail plan" as required by the vessel's stability letter.
Condition: Unknown
Due 21 March 2001
Resolved 29 April 2002
Resolution: Sail plan is now onboard the vessel.
Navigation
Issued 26 January 2000 Resolved
Provide an air receiver, that is ASTM certified, for the vessel's horn and service air system. The air receivers that are not ASTM certified must be removed or taken out of service. A suitable horn must be provided as per the Navigation Rules.
Condition: Unknown
Due 26 January 2000
Resolved 26 January 2000
Documentation
Issued 26 January 2000 Resolved
Provide an annual MIS report on the vessel's drug testing program results to the Coast Guard in accordance with 46CFR16.
Condition: Unknown
Due 26 January 2000
Resolved 26 January 2000
Navigation
Issued 29 March 1999 Resolved
INSTALL PROPER LIGHT BULBS IN NAV. LIGHT FIXTURES. VESSEL IS RESTRICTED TODAYLIGHT OPERATIONS UNTIL REQUIREMENT HAS BEEN CORRECTED.
Condition: Unknown
Due 29 March 1999
Resolved 29 March 1999
Accommodation/Occupational Safety
Issued 29 March 1999 Resolved
INSTALL AN EMERGENCY ESCAPE LADDER IN FORWARD BERTHING AREA.
Condition: Unknown
Due 29 March 1999
Resolved 29 March 1999
Navigation
Issued 17 February 1998 Resolved
Provide corrected or most current charts of Southern California operating area i.e. San Pedro Bay, Ventura, San Diego, etc.
Condition: Unknown
Due 17 February 1998
Resolved 17 February 1998
Lifesaving
Issued 17 February 1998 Resolved
Provide Class I, 406 mHZ EPIRB. Until corrected, vessel limited to 3 milesfrom shore while carrying passengers.
Condition: Unknown
Due 17 February 1998
Resolved 17 February 1998
Lifesaving
Issued 17 February 1998 Resolved
Provide lifejacket donning placard.
Condition: Unknown
Due 17 February 1998
Resolved 17 February 1998
Navigation
Issued 17 February 1998 Resolved
Provide emergency radio instruction placard as per 46 C.F.R. Part 184.510.
Condition: Unknown
Due 17 February 1998
Resolved 17 February 1998
Documentation
Issued 7 May 1996 Resolved
PROVIDE CURRENT CERTIFICATE OF DOCUMENTATION
Condition: Unknown
Due 6 June 1996
Resolved 10 May 1996
Accommodation/Occupational Safety
Issued 16 February 1996 Resolved
Provide proper ventilation to forepeak compartment.
Condition: Unknown
Due 16 February 1996
Resolved 16 February 1996
Construction/Loadline
Issued 16 February 1996 Resolved
Replace plastic seavalve for forward head/grey water tank with a metallic valve.
Condition: Unknown
Due 16 February 1996
Resolved 16 February 1996
Navigation
Issued 17 April 1995 Resolved
SWING BOAT AND RECALIBRATE MAGNETIC COMPASS. PROVIDE NEW DEVIATION CARD.
Condition: Unknown
Due 17 April 1995
Resolved 17 April 1995
Documentation
Issued 17 April 1995 Resolved
PROVIDE CURRENT FCC CERTIFICATES: 1) SHIP RADIO STATION PERMIT, 2) RADIO SAFETY TELEPHONY.
Condition: Unknown
Due 17 April 1995
Resolved 17 April 1995
Electrical
Issued 17 April 1995 Resolved
REPLACE COVER PLATE FOR ELECTRICAL OUTLET NEXT TO GALLEY SINK.
Condition: Unknown
Due 17 April 1995
Resolved 17 April 1995
Fire Fighting
Issued 17 April 1995 Resolved
REPLACE STBD FIRE HOSE WITH UL APPROVED OR FM LINED HOSE.
Condition: Unknown
Due 17 April 1995
Resolved 17 April 1995
Engineering
Issued 17 April 1995 Resolved
INSTALL LOW VENTILATION DUCTING FOR ENGINEROOM IAW 46 CFR 182.20-45.
Condition: Unknown
Due 17 April 1995
Resolved 17 April 1995
Lifesaving
Issued 17 April 1995 Resolved
REMOVE ALL PAINT, THINNERS, STAINS, AND ALL RELATED EQUIPMENT FROM FORE PEAK. ALSO REMOVE HALON FIRE EXTINGUISHER BOTTLE FROM FORE PEAK. EITHER PROPERLY STORE PAINTS IN A DEDICATED AND SPECIFICALLY DESIGNATED STAND ALONE PAINT LKR OR REMOVE RELATED ITEMS OR SUBMIT PLANS TO MODIFY FORE PEAK
Condition: Unknown
Due 17 April 1995
Resolved 17 April 1995
Electrical
Issued 17 April 1995 Resolved
PROVIDE GLASS GLOBES OR LIGHT COVERS FOR THE FOLLOWING LIGHTS: 1) LAZARETTE COMPARTMENT, 2) GALLEY OVERHEAD IN WAY OF STOVE, 3) OVERHEAD RED LIGHT IN CREWS QUARTERS BY LADDER, 4) STBD SIDE LIGHT OF PAINT LOCKER.
Condition: Unknown
Due 17 April 1995
Resolved 17 April 1995
Electrical
Issued 17 April 1995 Resolved
COVER OLD 12 VOLT ELECTRICAL PANEL BLANK IN SHIP'S LIBRARY.
Condition: Unknown
Due 17 April 1995
Resolved 17 April 1995
Electrical
Issued 17 April 1995 Resolved
MARK ALL EMERGENCY LIGHTS WITH 1/2 INCH "E" MARKS.
Condition: Unknown
Due 17 April 1995
Resolved 17 April 1995
Navigation
Issued 17 April 1995 Resolved
PROVIDE BLACK CONICAL DAYSHAPE.
Condition: Unknown
Due 17 April 1995
Resolved 17 April 1995
Construction/Loadline
Issued 6 April 1994 Resolved
CAP THE UNUSED 1 1/4" BALL VALVE IN THE CARGO HOLD BILGE WITH A METAL CAP.
Condition: Unknown
Due 21 April 1994
Resolved 12 April 1994
Deck/Cargo
Issued 6 April 1994 Resolved
REPLACE THE WASTED RETAINING PIN IN ANCHOR CHAIN DETACHABLE LINKS (ONE PORTAND ONE STARBOARD OF TWO LINKS ON EACH ANCHOR RODE). MAY PROVIDE ONE VIABLEANCHOR RODE OF THREE SHOTS USING THE TWO GOOD LINKS AS AN INTERIM MEASURE TO PERMIT THE CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 6 April 1994
Resolved 6 April 1994
Electrical
Issued 6 April 1994 Resolved
PROPERLY SUPPORT LOOSE WIRING (ARMORED CABLE) TO STARBOARD OF THE FORWARD HOLDING TANK.
Condition: Unknown
Due 21 April 1994
Resolved 12 April 1994
Electrical
Issued 6 April 1994 Resolved
REMOVE OR TERMINATE IN A JUNCTION BOX DEADENDED WIRING IWO ANCHOR CHAIN BOXES (TWO ARMORED CABLE, ONE ROMEX CABLE).
Condition: Unknown
Due 6 April 1994
Resolved 6 April 1994
Accommodation/Occupational Safety
Issued 6 April 1994 Resolved
PROVIDE WRITTEN DOCUMENTATION TO THE [name withheld] AND FUTURE COMPLETED MODIFICATIONS TO THE CARGO HOLD AREA, SPECIFICALLY ADDRESSING THEIMPACT OF EXISTING AND FUTURE COMPLETED MODIFICATIONS ON VESSEL STABILITY.
Condition: Unknown
Due 6 April 1994
Resolved 6 April 1994
Documentation
Issued 8 March 1994 Resolved
RENEW MASTERS LICENSE EXPIRED 18FEB94.
Condition: Unknown
Due 8 March 1994
Resolved 8 March 1994
Documentation
Issued 24 June 1993 Resolved
PROVIDE CURRENT FCC CERTIFICATES: SHIP RADIO STATION PERMIT, MARINE RADIO OPERATOR PERMIT, & RADIO TELEPHONY.
Condition: Unknown
Due 24 June 1993
Resolved 24 June 1993
Documentation
Issued 24 June 1993 Resolved
PROVIDE CURRENT CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 24 June 1993
Resolved 24 June 1993
Fire Fighting
Issued 24 June 1993 Resolved
PROVIDE 1 50'X1.5" UL APPROVED FIRE HOSE.
Condition: Unknown
Due 24 June 1993
Resolved 24 June 1993
Lifesaving
Issued 24 June 1993 Resolved
PROVE OPERATION OF EMERGENCY LIGHTING.
Condition: Unknown
Due 24 June 1993
Resolved 24 June 1993
Documentation
Issued 20 April 1992 Resolved
PROVIDE WASTE MANAGEMENT PLAN.
Condition: Unknown
Due 20 May 1992
Resolved 20 May 1992
Fire Fighting
Issued 20 April 1992 Resolved
REPLACE STBD FIREHOSE WITH UL APPROVED HOSE.
Condition: Unknown
Due 20 May 1992
Resolved 20 May 1992
Documentation
Issued 20 April 1992 Resolved
PROVIDE DRUG TESTING PROGRAM.
Condition: Unknown
Due 20 April 1992
Resolved 20 April 1992
Electrical
Issued 20 April 1992 Resolved
PROVIDE COVERS FOR ELECTRICAL JUNCTION BOX ON ANCHOR WINDLASS AND BOX IN NAV ROOM.
Condition: Unknown
Due 20 May 1992
Resolved 20 May 1992
Lifesaving
Issued 20 April 1992 Resolved
PROVIDE MOUNTS FOR FLOATLIGHTS ON LIFEFLOAT AND RING BUOY FWD.
Condition: Unknown
Due 20 May 1992
Resolved 20 May 1992
Accommodation/Occupational Safety
Issued 10 March 1992 Resolved
REMOVE THE TYPE I MSD INSTALLED IN THE FORWARD HEAD AND REPLACE IT WITH A MSD TYPE APPROVED FOR USE ON INSPECTED VESSELS OR PROVIDE PROOF THAT THE UNIT HAS BEEN ACCEPTED BY COMDT (G-MVI-3) FOR USE ON UNINSPECTED VESSELS.
Condition: Unknown
Due 20 May 1992
Resolved 20 May 1992

Casualty record · 4

1 May 2010Routine · role: Involved in a Marine Casualty · activity 3731030
14 July 2010Routine · role: Transiting Vicinity of Primary Subject · activity 3795816
9 March 2018Routine · role: Involved in a Marine Casualty · activity 6453986
27 September 2018Routine · role: Involved in a Marine Casualty · activity 6550980
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.