← All vessels
THELMA JEAN
Passenger Barge (Inspected) · Barge class · Built 1980s · USCG Heartland District (CGD-H) · Other hulls named THELMA JEAN
THELMA JEAN is a 1988 passenger barge (inspected). The Coast Guard has recorded 61 inspections since 1988, most recently in July 2026, along with 63 deficiencies.
Records from 1988 to 2026. Most recent: inspection, 2 July 2026.
- Built
- 1988
- Last inspected
- 2 July 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 63 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
927284
305062
Flag
UNITED STATES
—
Maury page id
psix-305062
Inspections, by type
…with no type recorded3
Years with a record
38 calendar years (1988–2026)
The 61 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.
Documentation record
Registered dimensions (L × B × D)80.0 ft × 28.0 ft × 4.0 ft
Registered tonnagegross 75 / net 75
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSERODINO, INC · GUILD, TN, UNITED STATES · built 1988
Hull materialSteel
PropulsionNone
Hull shapeBox
Hull configurationMonohull
Hailing portST LOUIS, MO
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 18 November 2025 · expires 30 November 2026
Service, as the file records itPassenger Barge (Inspected)
Hull formunknown (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it75 - Simplified, Net Ton
75 - Simplified, Gross Ton
75 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 61
2 July 2026
Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8426226
10 December 2025
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8275860
8 October 2024
Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8009624
19 September 2023
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7784964
15 September 2022
COI Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7557911
30 August 2022
Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7536502
8 July 2021
Deficiency Check · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7248860
12 November 2020
Deficiency Check · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7081663
14 November 2019
Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6834482
19 October 2018
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6565860
17 August 2017
COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6243560
26 July 2017
Administrative Inspection · Internal Structural Exam · Examination of Repairs · Deficiency Check · Hull Examination
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6211798
17 November 2016
Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6032499
28 September 2015
Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5730852
12 November 2014
Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5023160
2 May 2014
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4848707
21 November 2013
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4757420
7 November 2013
Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4744095
25 September 2012
COI Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4406764
30 July 2012
Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4396102
17 October 2011
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4166416
19 July 2011
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4087383
17 February 2011
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3947429
25 October 2010
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3877123
29 December 2009
Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3656352
11 August 2009
Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3562485
16 July 2009
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3536516
9 October 2008
Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3341328
4 October 2007
COI Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3070355
14 August 2007
Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3027394
1 November 2006
Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2812156
1 December 2005
Administrative Inspection · Annual Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2527145
16 November 2004
Administrative Inspection
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2242387
3 November 2004
Annual Inspection · Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2233790
2 December 2003
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1957284
12 November 2003
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1901778
17 September 2002
COI Inspection · Internal Structural Exam · Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1676708
3 July 2001
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1432547
24 July 2000
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1369777
2 September 1999
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 782611
1 July 1999
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1360989
28 June 1999
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1433508
31 October 1997
Hull Examination
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1464061
18 April 1997
Administrative
Administrative · MSO Paducah · USCG Heartland District (CGD-H) · Activity 774498
12 March 1996
COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1456344
18 July 1995
Administrative
Administrative · MSO Paducah · USCG Heartland District (CGD-H) · Activity 876099
20 March 1995
COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1142291
17 June 1994
Deficiency Check
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 869460
4 May 1994
Deficiency Check
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1367039
17 March 1994
COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1167907
20 May 1993
Deficiency Check
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 843372
4 May 1993
Hull Examination
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1149777
23 March 1993
COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1141605
26 March 1992
COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 951459
4 April 1991
COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 919161
5 April 1990
COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 930288
20 April 1989
COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1194467
27 August 1988
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1345634
3 August 1988
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1034005
3 August 1988
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1341855
10 May 1988
Initial Certification
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1201032
Deficiency record · 63
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 10 December 2025
Resolved
On a vessel of more than 19.8 meters (65 feet) in length, the minimum capacity of the fire pump must be 189 liters (50 gallons) per minute at a pressure of not less than 414 kPa (60 psi) at the pump outlet. The #1 fire pump was inoperable, prove proper operation of both fire pumps.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 10 December 2025
Resolved
A vessel of at least 7.9 meters (26 feet) in length must be provided with individual bilge lines and bilge suctions for each watertight compartment. The bilge system was not able to keep suction due a leak in the bilge piping. Prove proper operation of the bilge system.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 October 2023
Resolved
Each floating waterlight must be approved IAW 161.010 in Sub Q of this chapter. Replace expired battery within 30 days.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 July 2021
Resolved
An adult life jacket meeting 46 CFR 160.002, .005, or .055 must be provided for each person carried on board vessel. Two adult life jackets were condemned during inspection due to deterioration of flotation material. Authorized passenger count is reduced until minimum number of approved life jackets (PFDs) are on board.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 8 July 2021
Resolved
The sidelights of vessels of 20 meters or more in length shall be fitted with matt black inboard screens. Screen paint on screen for port sidelight had significantly deteriorated revealing a lighter coating. Renew screen coating to matt black.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 8 July 2021
Resolved
For vessels having a square bow, the name of the vessel must be marked on some clearly visible exterior part of the bow in a manner to avoid obliteration. The name must be marked on some clearly visible exterior part of the stern. Vessel name on bow obstructed by fitting and name not on stern of vessel. Properly mark name (not less than 4 inches in height).
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 November 2020
Resolved
Fire main piping and fittings must comply with subpart G, part 182 (Piping Systems). Forward fire main piping (a vital piping system) leaked at fire hose connection point due to incorrect combination of threaded fittings. Prove proper operation of fire main and hose connection. Corrected by end of inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 November 2020
Resolved
An adult life jacket meeting 46 CFR 160.002, .005, or .055 must be provided for each person carried on board vessel. Two adult life jackets were condemned during inspection due to deterioration of flotation material. Authorized passenger count is reduced until minimum number of approved life jackets (PFDs) are on board. Corrected during inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 November 2018
Resolved
Ferry Barge was missing 01 adult size life jacket. Add 01 life jacket to barge to meet passenger life saving COI requirements.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 November 2018
Resolved
Replace worn hydraulic hoses on vehicle ramp actuators.
Engineering › Bilge Water Management System › Not Operational
Issued 12 September 2017
Resolved
Installed bilge pumps would not take suction on bilge manifold. Prove proper operation prior to carrying passengers for hire.
Engineering › Bilge Water Management System › Strainer
Issued 26 July 2017
Resolved
Bilge strainers in voids #3 and #8 were wasted beyond suitability. Strainers required to be replaced.
Lifesaving › Lifebuoys › Serviceable
Issued 17 November 2016
Resolved
Buoyance of ring lifebuoy severly compromized due to internal water logged material affecting manufacturing standard requirement found in 46 CFR 160.050. Ring to be removed from service and replaced with an approved device.
Engineering › Bilge Water Management System › Strainer
Issued 3 August 2012
Resolved
Replace wasted bilge strainer in void #7.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 17 October 2011
Resolved
Install flashing yellow navigational light in accordance with Rules of the Road
Lifesaving › Lifebuoys › Serviceable
Issued 17 October 2011
Resolved
Install new battery in life buoy (ring) flashing light assembly. Although operating, the light's battery shelf life expired in 2010 and is considered unreliable.
Fire Fighting › Fire Pumps › Power Source
Issued 17 October 2011
Resolved
Both installed fire pumps have excessive oil leaks. The MO side fire pump has many loose components including the ignition system and muffler. Both pump housings leak thus allowing the pump to lose its water prime. Vessel crew struggled to get the pumps primed during fire drill. Overhaul both pumps to make them more reliable.
Electrical › Lighting (service) › Lighting Branch Circuit
Issued 17 October 2011
Resolved
Throughout barge, properly connect and place all navigational light wiring connections in junction boxes to make them more reliable. Seal all junction boxes from all natural elements.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 3 November 2010
Resolved
Properly repair/replace inoperable navigation light. Correct prior to conducting night operations.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 29 October 2009
Resolved
Removed from service 02 adult and 07 child PFD's.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 29 October 2009
Resolved
Life line bag was in poor condition and would not allow line to be freely pulled out.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 11 August 2009
Resolved
Lanyard on waterlight wasted.
Operations/Management › Drills/Instruction › Not Conducted
Issued 11 August 2009
Resolved
Man overboard and fire drills not conducted due to weather.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 14 August 2007
Resolved
electrical box covers to be replaced in #1 and #8 voids
Construction/Loadline › Hull › Weld
Issued 14 August 2007
Resolved
Repair cracked welds on both landing ramps, as marked.
Engineering › Bilge Water Management System › Strainer
Issued 14 August 2007
Resolved
Replace strainers to original in #1 and #2 voids, lower strainer in #1 void to less than 1 inch off of the deck
Fire Fighting › Remote Fuel Shutoff › General
Issued 15 November 2004
Resolved
Properly mark emergency shut off valves on MV Brussels.
Engineering › Fuel Oil Service System › Hose
Issued 15 November 2004
Resolved
Properly double clamp fuel lines on STBD engine.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 15 November 2004
Resolved
Properly install safety guard on exposed moving parts of alternator attached to STBD engine
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 15 November 2004
Resolved
Properly replace broken tamper seals on all portable fire extinguishers.
Lifesaving › Lifejacket/PFD (Type IV) › Condition
Issued 15 November 2004
Resolved
Replace type IV life ring, nearest to the MV Brussels.
Navigation › Piloting/Steering
Issued 12 November 2003
Resolved
Provide copy of current navigation rules. LEGACY COMPONENT DESC: Inland Navigation Rules
Communications › Audible Communications › Horn/Whistle
Issued 12 November 2003
Resolved
Repair/replace UTV air horn and show proper operation.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 12 November 2003
Resolved
Properly mark vessel name and place reflective tape on life ring. LEGACY COMPONENT DESC: Markings (ship name/port)
Construction/Loadline
Issued 1 July 1999
Resolved
Replace all loading ramp hydraulic hoses
Construction/Loadline
Issued 1 July 1999
Resolved
Prove proper operation of the bilge pumping system
Construction/Loadline
Issued 1 July 1999
Resolved
Install sufficient number of clamps on hydraulic piping for loading ramps to keep pipes from vibrating.
Electrical
Issued 1 July 1999
Resolved
Install covers on all battery boxes.
Fire Fighting
Issued 1 July 1999
Resolved
Properly mount all portable fire extinguishers
Engineering
Issued 1 July 1999
Resolved
Repair or replace hydraulic oil hose fitting on top of fluid reservoir.
Documentation
Issued 28 June 1999
Resolved
Provide proof of stability letter
Construction/Loadline
Issued 28 June 1999
Resolved
Install check valve in bilge suction line.
Construction/Loadline
Issued 28 June 1999
Resolved
Prior to carrying passengers prove proper operation of bilge system._x001C_ (All void suctions)
Construction/Loadline
Issued 28 June 1999
Resolved
Properly repair all reach rods for bilge suction valves.
Construction/Loadline
Issued 28 June 1999
Resolved
Repair all fractures on the Coupling of the Tow Alton.
Electrical
Issued 28 June 1999
Resolved
Install plug in junction box for nav lighting.
Fire Fighting
Issued 28 June 1999
Resolved
Recharge or remove B-II fire extinguisher.
Lifesaving
Issued 28 June 1999
Resolved
Mount No Smoking, Marpol and garbage placard on barge.
Lifesaving
Issued 28 June 1999
Resolved
Renew Lifering line with 60' of 5/16" floating line.
Construction/Loadline
Issued 28 June 1999
Resolved
Repair Hydralic leak on tow (Alton) coupling fitting.
Construction/Loadline
Issued 28 June 1999
Resolved
Provide hand bilge pump with a Minimum capacity of 10 gpm.
Construction/Loadline
Issued 28 June 1999
Resolved
Paint draft marks contrasting in color. (White)
Lifesaving
Issued 28 June 1999
Resolved
Prior to using the tow vessel Alton to push an inspected vessel it must pass a satisfactory inspection by the attending maringe inspector.
Fire Fighting
Issued 28 June 1999
Resolved
Install double hose clamps on fire pump discharge flex hose.
Lifesaving
Issued 28 June 1999
Resolved
Install Coast Guard approved First Aid kit.
Accommodation/Occupational Safety
Issued 31 October 1997
Resolved
MAKE PERMANENT REPAIRS TO BOW LOADING RAMP, AT LEADING EDGE, WHERE FRACTURED.
Construction/Loadline
Issued 31 October 1997
Resolved
RENEW OR REPLACE SEALING GASKETS ON ALL MAIN DECK HATCH COVERS.
Fire Fighting
Issued 4 May 1994
Resolved
PROVIDE EVIDENCE THAT THE NEW 50 FT. FIRE HOSE MEETS THE APPROPRIATE UL STANDARD OR FEDERAL SPECIFICATION AS REQUIRED BY 46 CFR 181.15-10(C),(D), AND (F) OR REPLACE THE HOSE WITH ONE MEETING THE REQUIRED UL STANDARD OR FEDERAL SPECIFICATION.
Lifesaving
Issued 17 March 1994
Resolved
THE NUMBER OF ADULT PASSENGERS ALLOWED ON BOARD IS LIMITED TO 25 UNTIL 1 ADDITIONAL ADULT SIZE PFD IS PLACED ON BOARD.
Accommodation/Occupational Safety
Issued 17 March 1994
Resolved
NO PASSENGERS ARE ALLOWED ON THE VESSEL DECK UNTIL GATES AND RAILS IN ACCORDANCE WITH 46 CFR 177.35-1 ARE INSTALLED.
Fire Fighting
Issued 17 March 1994
Resolved
REPLACE 1.5" FIRE HOSE THAT IS SHOWING SIGNS OF DETERIORATION WITH AN ACCEPTABLE 1.5" HOSE IN ACCORDANCE WITH 46 CFR 181.15-10(c), (d), AND (f).
Documentation
Issued 17 March 1994
Resolved
POST MARPOL V GARBAGE POLLUTION PLACARD.
Construction/Loadline
Issued 4 May 1993
Resolved
COMPLETE MAINTENANCE ON ALL BILGE VALVE REACH RODS AND SHOW SATISFACTORY OPERATION OF ALL VALVES.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.