Records from 1988 to 2015. Most recent: inspection, 5 October 2015.
Documentation record
Registered dimensions (L × B × D)64.8 ft × 18.0 ft × 4.5 ft
Registered tonnagegross 92 / net 85
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSKIPPERLINER INDUSTRIES · LA CROSSE, WI, UNITED STATES · built 1988
Hull materialSteel
PropulsionDiesel Outdrive
Hull shapeShip
Hull configurationMonohull
Hailing portMILWAUKEE, WI
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 6 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it92 - Simplified, Gross Ton
85 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 38
5 October 2015
Damage Survey · Drydock Extension · Hull Examination · Examination of Repairs
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 5754498
23 July 2012
Re-Inspection
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 4387720
20 March 2010
COI Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 3704450
5 May 2008
Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 3202844
2 April 2008
Hull Examination
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 3176719
9 April 2007
Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 2906473
24 April 2006
Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 2624902
21 March 2005
COI Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 2309644
14 May 2004
Annual Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 2067288
3 June 2003
Annual Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1808437
26 February 2003
Hull Examination
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1749656
15 April 2002
Annual Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1605200
19 September 2001
Administrative
Administrative · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1074378
14 September 2001
Deficiency Check
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1071882
25 April 2001
Deficiency Check
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1064718
12 April 2001
Annual Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1465661
24 April 2000
Deficiency Check
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 819488
11 April 2000
COI Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 819494
7 April 1999
Re-Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1131092
3 April 1998
Re-Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1124123
2 March 1998
Hull Examination
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 782420
21 May 1997
Deficiency Check
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 775829
15 April 1997
COI Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1100626
8 May 1996
Re-Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1082260
26 April 1995
Deficiency Check
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 883826
20 April 1995
Re-Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1167649
10 June 1994
Type not recorded
No type recorded · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 654455
6 June 1994
Type not recorded
No type recorded · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 57326
22 April 1994
COI Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1167093
23 July 1993
Deficiency Check
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1143521
8 June 1993
Re-Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1143752
9 March 1993
Hull Examination
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1148047
6 May 1992
Re-Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 945065
20 May 1991
COI Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1219004
5 July 1990
Re-Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 920333
23 August 1989
Re-Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 895346
5 July 1988
Initial Certification
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 894651
29 June 1988
Initial Construction-Excluding Oversight · Hull Examination · Plan Review "T" Boat
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 894655
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 23 July 2012
Resolved
Bow thruster space open to passenger compartment via air conditioner duct space not properly sealed.
Due 24 August 2012
Resolved 27 September 2012
Resolution: Wasted duct and seal renewed when unit reinstalled.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 7 April 2010
Resolved
Provide proper ring life buoy floating water light to satisfaction of MSD Sturgeon Bay.
Due 30 April 2010
Resolved 23 April 2010
Resolution: Received email from [name withheld] attesting to purchase of new ring buoy water lights.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 7 April 2010
Resolved
Provide proper light cover for light in pilothouse to prevent electrical shock to the satisfaction of MSD Sturgeon Bay.
Due 30 April 2010
Resolved 23 April 2010
Resolution: Received email from [name withheld] attesting to installation of a new light fixture in the operating station.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 5 May 2008
Resolved
Provide proper Deck Rails for passenger protection at windows prior to carrying passengers with the windows open. To be repaired prior to 23 May 08 IAW 46-CFR-177.900.
Condition: Unknown
Due 23 May 2008
Resolved 29 May 2008
Resolution: Master provided verbal statement over landline that he installed the rail IAW the 835 requirement.
Fire Fighting › Fire Pumps › Pressure
Issued 21 March 2005
Resolved
Install pressure gauge in the fire main I.A.W. 46 CFR 181.300(b).
Action required: 705 - Other - as specified
Due 21 April 2005
Resolved 29 March 2005
Resolution: New gauge installed and tested sat.
Engineering › Thrusters › Hose
Issued 21 March 2005
Resolved
Replace fuel oil return flex hose on bow thruster diesel engine with an approved fuel oil flex hose I.A.W. 46 CFR 182.720(e).
Action required: 705 - Other - as specified
Due 21 April 2005
Resolved 29 March 2005
Resolution: Replaced with approved flex hose.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 21 March 2005
Resolved
Conduct fire and man overboard drils in the presence of a Coast Guard Inspector as river ice conditions permit.
Action required: 705 - Other - as specified
Due 21 April 2005
Resolved 31 March 2005
Resolution: Witnessed sat drills.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Marine Type Label
Issued 3 June 2003
Resolved
Replace two Class B-I CO2 portable fire extinguishers with Class A-II dry chemical portable fire extinguishers in the accomodation space, I.A.W. 46 CFR 181-500(a).
Due 3 June 2003
Resolved 3 June 2003
Resolution: Corrected prior to end of inspection.
Electrical › Lighting (service)
Issued 15 April 2002
Resolved
Replace existing household "Romex" cabling from main distribution panel to exterior lighting controls with approved marine type "boat cable" and secure properly. LEGACY COMPONENT DESC: Lighting Branch Circuit
Condition: Improper Installation
Due 15 June 2002
Resolved 26 February 2003
Operations/Management › Drills/Instruction
Issued 15 April 2002
Resolved
Drills to be conducted at later date when entire crew is on hired and onboard. LEGACY COMPONENT DESC: Man Overboard Recovery
Action required: 705 - Other - as specified
Due 30 May 2002
Resolved 20 May 2002
Resolution: Completed satisfactory drills
Lifesaving › Buoyant Apparatus
Issued 15 April 2002
Resolved
Replace retro-tape on ring buoy with approved type.
Condition: Improper/Lack of Maintenance
Due 31 May 2002
Resolved 20 May 2002
Resolution: Inspected and found satisfactory.
Lifesaving › Lifejacket/PFD (Type I)
Issued 15 April 2002
Resolved
Replace retro tape on three adult type 1 PFD with approved material. LEGACY COMPONENT DESC: Retroreflective Material
Condition: Improper/Lack of Maintenance
Due 31 May 2002
Resolved 20 May 2002
Resolution: Inspected and found satisfactory.
Unknown
Issued 12 April 2001
Resolved
UPDATE SENIOR DECKHAND DESIGNATION LETTER TO REFLECT CURRENT CREWMEMBERS.
Condition: Unknown
Due 16 April 2001
Resolved 10 May 2001
Unknown
Issued 12 April 2001
Resolved
INSTALL APPROVED INSULATING MATERIAL UNDER ENGINE HATCH COVERS IAW 46 CFR 177.410
Condition: Unknown
Due 12 April 2001
Resolved 12 April 2001
Unknown
Issued 12 April 2001
Resolved
PERFORM UNERWAY DRILLS (FIRE, MAN OVERBOARD) IN PRESENCE OF USCG.
Condition: Unknown
Due 9 May 2001
Resolved 10 May 2001
Unknown
Issued 12 April 2001
Resolved
IMPROVE OPERATION OF SLIDING DOOR, STARBOARD SIDE, FORWARD SO AS IT MOVES FREELY FOR EMERGENCY EXIT.
Condition: Unknown
Due 20 April 2001
Resolved 10 May 2001
Unknown
Issued 12 April 2001
Resolved
PROVIDE CURRENT DOCUMENTATION FOR VESSEL (RENEWAL STICKER).
Condition: Unknown
Due 26 April 2001
Resolved 10 May 2001
Electrical
Issued 11 April 2000
Resolved
MAKE PERMANENT REPAIRS AND DEMONSTRATE PROPER OPERATION OF THE OIL PRESSUREGAUGE ON VESSELS SHIP SERVICE GENERATOR.
Condition: Unknown
Due 27 June 2000
Resolved 27 June 2000
Engineering
Issued 11 April 2000
Resolved
MAKE PROPER REPAIRS TO THE BOW THRUSTER JACKET WATER TEMPERATURE GAUGE.
Condition: Unknown
Due 27 June 2000
Resolved 27 June 2000
Construction/Loadline
Issued 11 April 2000
Resolved
CLEAN EDGES OF THE FORWARD WEATHER DECK HATCH COVERS AND MAKE WATERTIGHT.
Condition: Unknown
Due 27 June 2000
Resolved 27 June 2000
Construction/Loadline
Issued 11 April 2000
Resolved
MAKE REPAIRS TO THE FRACTURE GLASS (2) ON THE STBD SIDE OF THE VESSELS MAINDECK.
Condition: Unknown
Due 27 June 2000
Resolved 27 June 2000
Lifesaving
Issued 15 April 1997
Resolved
CONDUCT THE FOLLOWING EMERGENCY DRILL'S: FIRE, MAN OVERBOARD AND STEERING CASUALTY. ALL DRILL'S ARE TO BE TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 15 April 1997
Resolved 15 April 1997
Electrical
Issued 15 April 1997
Resolved
MAKE REPAIRS AND PROVE SATISFACTORY OPERATION OF THE AMPERE AND FREQUENCY METER FOR THE 40 KW SHIP SERVICE GENERATOR.
Condition: Unknown
Due 15 April 1997
Resolved 15 April 1997
Engineering
Issued 20 April 1995
Resolved
REPLACE PLASTIC CLOTHES DRIER HOSE AND INSTALL A FIREPROOF TYPE FLEX DUCT HOSE IN WAY OF THE SUPPLY AND EXHAUST VENTS FOR THE BOW THRUSTER COMPARTMENT.
Condition: Unknown
Due 20 April 1995
Resolved 20 April 1995
Engineering
Issued 20 April 1995
Resolved
REPAIR DIESEL OIL LEAK IN WAY OF THE PORT MAIN DIESEL ENGINE FUEL PUMP SOLENOID. REPAIRS SHALL BE MADE PRIOR TO CARRIAGE OF PASSENGERS FOR HIRE.
Condition: Unknown
Due 20 April 1995
Resolved 20 April 1995
Engineering
Issued 8 June 1993
Resolved
PROVIDE A NATURAL VENTILATION SUPPLY FOR THE AFT DIESEL STORAGE TANK SPACE.MINIUM VENT OPENING SHALL BE NO LESS THAN 1-1/2". REF: 46 CFR 182.20-50.
Condition: Unknown
Due 8 June 1993
Resolved 8 June 1993
Electrical
Issued 8 June 1993
Resolved
PROVIDE AN EMERGENCY DISCONNECT SWITCH IN THE NORMALLY UNGROUNDED MAIN SUPPLY CONDUCTOR, IN WAY OF ALL SUPPLY BATTERIES. LOCATION OF THE SWITCHESSHALL BE AS CLOSELY AS PRACTICABLE TO THE BATTERY. _x001C_ REF: 46 CFR 183.05-10 (f).
Condition: Unknown
Due 8 June 1993
Resolved 8 June 1993
Lifesaving
Issued 8 June 1993
Resolved
VESSEL TO PROVIDE SIX (6) ADDITIONAL ADULT LIFEJACKETS, TO COMPLY WITH VESSELS COI LIFESAVING REQUIREMENT. TOTAL ADULT PERSONS ON BOARD SHALL BE REDUCED BY SIX (6) UNTIL ADDITIONAL JACKETS ARE PROVIDED.
Condition: Unknown
Due 8 June 1993
Resolved 8 June 1993