MAURY USCG vessel records Sign in
← All vessels

HOS RIDGEWIND

HOS RIDGEWIND is a 2001 offshore supply vessel. The Coast Guard has recorded 51 inspections since 2001, most recently in March 2026, along with 27 deficiencies and 3 casualty investigations between 2006 and 2016.

Records from 2001 to 2026. Most recent: inspection, 3 March 2026.

Built
2001
Last inspected
3 March 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9260706 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
MEXICO
369528000 (licence lapsed)
Maury page id
psix-30523

Inspections, by type

…with no type recorded8
Years with a record 20 calendar years (2001–2026)
The 51 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it5631 - Displacement, Metric Ton
3116 - Dead Weight, Metric Ton
2861 - Convention (Subpart B), Gross Ton
858 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDA6136MMSI 369528000 · cancelled · compulsorily equipped · granted 10 August 2011, cancelled 3 August 2021
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 51

3 March 2026 PSC B
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8319513
11 September 2024 PSC B
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 8000560
7 March 2023 PSC B
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7646149
15 March 2022 PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7410853
7 March 2022 PSC B
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7404499
7 October 2020 PSC B
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7064297
1 April 2020 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6933618
8 January 2020 COE-Administrative
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6885213
21 October 2019 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6830769
25 April 2019 Ballast Water Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6670403
19 February 2019 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6651090
28 June 2018 SIP Inspection/Audit · MARPOL Annex I Examination · Administrative Inspection · Annual Inspection · MTSA/ISPS Verification · MARPOL Annex VI Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6458124
10 March 2017 MARPOL Annex II Examination · COI Inspection · MTSA/ISPS Verification · MARPOL Annex VI Survey · MARPOL Annex IV Survey · MARPOL Annex V Examination · MARPOL Annex I Examination · SIP Inspection/Audit
Physical examination · Activities Europe · Activity 6102443
23 November 2016 Type not recorded
No type recorded · Activities Europe · Activity 6046497
24 September 2016 In-Service Inspection
Physical examination · Activities Europe · Activity 5989229
11 May 2016 MARPOL Annex V Examination · MARPOL Annex VI Survey · SIP Inspection/Audit · MARPOL Annex IV Survey · MTSA/ISPS Verification · MARPOL Annex I Examination · Annual Inspection
Physical examination · Activities Europe · Activity 5874722
3 May 2016 Internal Structural Exam · Drydock Exam
Physical examination · Activities Europe · Activity 5867849
16 October 2015 Administrative Inspection · Construction Oversight
Physical examination · Activities Europe · Activity 5744136
7 October 2014 Administrative Inspection
Administrative · Activities Europe · Activity 5000449
19 August 2014 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4975212
20 May 2014 Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4862370
14 May 2014 MTSA/ISPS Verification · Construction Oversight · MARPOL Annex IV Survey · Periodic Inspection · MARPOL Annex VI Survey · Administrative Inspection · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4907676
18 July 2012 SIP Initial Entry · Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4382725
30 January 2012 Administrative Inspection · Construction Oversight · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4234476
28 December 2010 Plan Review (Other than "T") · Annual Inspection · Deficiency Check · Administrative Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3916602
16 September 2010 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3850947
27 January 2009 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3400125
7 January 2008 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3117609
25 October 2006 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2809210
24 October 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2806964
31 January 2006 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2576475
30 January 2006 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2576091
24 January 2006 Administrative Inspection · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2572144
7 January 2006 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2564184
14 December 2004 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2259297
17 November 2004 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2243145
1 September 2004 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2207735
29 June 2004 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2115480
4 June 2004 MTSA/ISPS Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2088641
26 May 2004 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2114224
20 April 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2048392
14 April 2004 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2044015
21 January 2004 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1989303
29 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1979359
17 June 2003 Administrative Inspection
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1819631
4 November 2002 Annual Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1700880
5 June 2002 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1626862
4 January 2002 Administrative Inspection
Administrative · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1475460
30 November 2001 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 773192
6 November 2001 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 772878
6 November 2001 Initial Construction-Excluding Oversight · Inclining Experiment · Initial Certification
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1458014

Deficiency record · 27

14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 7 March 2022 Resolved
Oil filtering equipment will ensure that any oily mixture discharged into the sea has an oil content not exceeding 15 ppm. The vessels oil filtering equipment is not operable. MARPOL I/14.6
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 March 2022
Resolved 8 March 2022
Resolution: Recieved technician report. Tech installed new pump to the OWS system. Ran function test. All systems and alarms operating withing manufacturer's specificaitons.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 7 October 2020 Resolved
BEFORE SHIP LEAVES PORT AND AT ALL TIMES DURING THE VOYAGE, ALL LIFE SAVING APPLIANCES SHALL BE IN WORKING ORDER AND READY FOR IMMEDIATE USE. RESCUE BOAT ENGINE UNABLE TO START DUE TO CORROSION ON BATTERY TERMINAL. SOLAS 74 (2014 CONS.) III/20.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 7 October 2020
Resolved 7 October 2020
Resolution: BATTERY WAS CHANGED OUT PRIOR TO USCG LEAVING THE VESSEL.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 28 June 2018 Resolved
Three watertight doors have gaskets with gaps of approximately 1/2" to 1/4". Ensure watertight doors are watertight prior to departure from port.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 July 2018
Resolution: New gaskets properly installed.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 28 June 2018 Resolved
Outboard engine on rescue boat is not listed on the rescue boat approval letter. Install proper outboard as per USCG approval letter.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 July 2018
Resolved 6 July 2018
Resolution: Evinrude 40 hp ETEC installed as required by rescue boat approval.
Electrical › Electric Generation Source (service) › Circuit Breaker
Issued 29 March 2017 Resolved
Reverse-power relay inoperable on #3 auxillary generator output breaker.
Action required: 705 - Other - as specified
Due 29 April 2017
Resolved 31 March 2017
Resolution: Rcvd attestation from Master that reverse power relay on the #3 Gen output breaker is now fully operational.
Communications › Alarms/Indicators › Engineers' Assistance-needed Alarm
Issued 4 June 2016 Resolved
Vessels PSTP's need to be approved by MSC then verified by the attending Marine Inspector.
Action required: 705 - Other - as specified
Due 30 June 2016
Resolved 10 June 2016
Resolution: Vessel provided us with the approval letter from MSC dated 29MAR2016, testing still needs to be completed.
Fire Fighting › Fire Pumps › Capacity
Issued 4 June 2016 Resolved
Vessels fire pumps (Regular and Emergency pump) operate at 150PSI and do not have a pressure relief valve installed. According to the vessels ICR FIRE-06 the pumps should not operate above 125PSI.
Action required: 705 - Other - as specified
Due 30 June 2016
Resolved 14 June 2016
Resolution: Vessel replaced pump impellers, decreasing the PSI to 122-125
Operations/Management › Streamlined Inspection Program › VAP Review and Revision
Issued 4 June 2016 Resolved
Vessel has not been completing monthly summary correction reports.
Action required: 705 - Other - as specified
Due 30 June 2016
Resolved 23 June 2016
Resolution: Vessel has been completing both ICR's and SCR's, vessel rep was unable to explain or extract information out of the computer based program. Vessel rep [name withheld] provided a power point presentation explaining the process.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 7 October 2014 Resolved
OWS (oily water separator) is not able to draw a suction on the oily residue tank due to a cracked diaphragm on the OWS supply pump. Vessel is required to retain all oily residues onboard until OWS is operational. Chief Engineer to provide attestation of proper operation of OWS.
Action required: 705 - Other - as specified
Due 3 November 2014
Resolved 3 November 2014
Resolution: Received e-mail from engineer stating that the cracked suction pipe was repaired and a satisfactory operational test was conducted to prove proper operation.
Deck/Cargo › Cargo Stowage › General
Issued 28 December 2010 Resolved
Submit plans for new FRAC package to MSC for approval or submit to ABS under NVIC 10-82 or have class submit plans to MSC under NVIC 10-92.
Due 28 January 2011
Resolved 6 January 2011
Documentation › Certificates/Documents › International Tonnage Certificate
Issued 28 December 2010 Resolved
Receive proper tonnage cert from class & submit to OCMI.
Due 28 January 2011
Resolved 6 January 2011
Fire Fighting › Fixed CO2 Fire Extinguishing System › Location
Issued 28 December 2010 Resolved
Mark exterior pump room WTD's as CO2 protected space
Due 4 January 2011
Resolved 24 January 2011
Fire Fighting › Means of Escape › Emergency Lighting
Issued 28 December 2010 Resolved
Install emergency lighting in client workshop & lab & tie into ship's emergency system.
Due 28 January 2011
Resolved 24 January 2011
Engineering › Pressure Vessel › Marking and Stamping
Issued 28 December 2010 Resolved
Provide U1A certificates for air receivers located in pump room.
Due 28 January 2011
Resolved 6 January 2011
Fire Fighting › Fixed Deck Foam System › Monitors
Issued 28 December 2010 Resolved
provide current foam analysis letter for foam stored in deck tanks.
Due 28 January 2011
Resolved 6 January 2011
Engineering › Diesel Engine (propulsion-reduction gear) › Pump, High Pressure (fuel injection)
Issued 7 January 2008 Resolved
Fuel Pressure regulator for #1 Main Engine leaking fuel from top side of diaphram. Renew Pressure regulator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 February 2008
Resolved 27 January 2009
Engineering › Fuel Oil Service System › Filter
Issued 7 January 2008 Resolved
Fuel leaks noted on all Racor fuel filters for Generator Prime Movers. Fix all leaks.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 February 2008
Resolved 27 January 2009
Engineering › Fuel Oil Service System › Filter
Issued 7 January 2008 Resolved
Missing drain plug on #3 Generator Racor housing. Install plug.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 February 2008
Resolved 27 January 2009
Engineering › Fuel Oil Service System › Piping
Issued 7 January 2008 Resolved
Spray tape missing from several High Pressure lines. Install SOLAS spray tape on all high pressure fittings.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 February 2008
Resolved 27 January 2009
Electrical › Electrical Distribution System (service) › Switchboard
Issued 7 January 2008 Resolved
Reverse Power relay would not open breaker until it had heated up, it could not be determine if it opened on Reverse Power or Thermal over-load. Service Reverse Power relay and reset to MFG specifications.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 February 2008
Resolved 27 January 2009
Fire Fighting › Semiportable Chemical-Foam Fire Extinguishers › Number
Issued 7 January 2008 Resolved
No Semi-Portable fire extinguisher onboard, COI requires 2 B-V's. Provide 450lbs of Dry Chemical for the Filling and Discharging of Marine Portable tanks.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 February 2008
Resolved 27 January 2009
Resolution: Vessel has (4) AFFF stations located on the back deck.
Engineering › Pressure Vessel › Relief Valve
Issued 24 January 2006 Resolved
Install Relief Vlaves on both Air Receivers prior to vessel operating.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 24 January 2006
Resolved 25 January 2006
Resolution: Relief valves installed.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 24 January 2006 Resolved
Show approval for #16 Ballast Tank conversion to fuel. Conduct all tests to demonstrate that tanks meet all requirements necessary. This testing is to be done at next dry dock, and approval is to be provided immediately. MSC letter attached to documents section.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 December 2006
Resolved 27 November 2006
Lifesaving
Issued 6 November 2001 Resolved
Ensure warning statement is incorporated into the maneuvering information fact sheet as per 33 CFR 164.35(g)(7).
Condition: Unknown
Due 12 December 2001
Resolved 12 December 2001
Navigation
Issued 6 November 2001 Resolved
Ensure emergency instructions are displayed at each muster station and in spaces where offshore workers are carried as per 46 CFR 133.80.
Condition: Unknown
Due 12 December 2001
Resolved 12 December 2001
Navigation
Issued 6 November 2001 Resolved
Ensure there is a simple operating instruction with a block diagram showingthe change over procedures for remote steering gear control systems and display on navigation bridge as per 33 CFR 164.35(k).
Condition: Unknown
Due 12 December 2001
Resolved 12 December 2001
Lifesaving
Issued 6 November 2001 Resolved
Replace all un approved decking in the lab space with Coast Guard approved decking.
Condition: Unknown
Due 12 December 2001
Resolved 12 December 2001

Casualty record · 3

1 December 2006Routine · role: Involved in a Marine Casualty · activity 2833676
16 November 2013Routine · role: Involved in a Marine Casualty · activity 4756168
23 November 2016Routine · role: Involved in a Marine Casualty · 1 injured · activity 6046497
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

BJ BLUE RAY (2006). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.