MAURY USCG vessel records Sign in
← All vessels

KOYO MARU

KOYO MARU is a 1987 freight ship. The Coast Guard has recorded 17 inspections since 1989, most recently in September 1999, along with 60 deficiencies — 6 with no resolution recorded — and 3 operational controls.

Records from 1989 to 1999. Most recent: operational control imposed, 10 September 1999.

Built
1987
Last inspected
10 September 1999
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8701832 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
305258
Flag
JAPAN
—
Maury page id
psix-305258

Inspections, by type

…with no type recorded16
Years with a record 6 calendar years (1989–1999)
The 17 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 27 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it1885 - Dead Weight, Ton
1950 - Convention (Subpart B), Gross Ton
629 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 17

10 September 1999 Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 432828
14 January 1999 Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 424591
1 December 1998 Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 723244
24 November 1998 Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 647075
19 November 1998 Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 422902
10 November 1998 Port Security Assessment
Type not classified · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 556618
14 August 1998 Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 419230
25 January 1998 Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 411946
24 November 1997 Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 410241
13 May 1997 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 403953
9 March 1997 Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 401372
1 February 1997 Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 399290
3 November 1995 Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 384570
1 November 1995 Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 384436
16 July 1993 Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 359646
11 November 1989 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 333641
1 April 1989 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 329507

Deficiency record · 60

Fire Fighting › Nozzles › Type
Issued 10 September 1999 No resolution recorded
MULTI-PURPOSE FIRE NOZZLE WHICH SHOOTS STREAM AND FOG REQUIRED. SEE SOLAS 74/78 II-2/4 ITEM 8.
Condition: Unknown
Action required: 705 - Other - as specified
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 10 September 1999 No resolution recorded
NON-CONDUCTIVE MATTING REQUIRED FOR ENGINE ROOM SWITCH BOARDS AND PUMP ROOMON DECK (AS NEEDED). SEE SOLAS 74/78 III 1/45/2.
Condition: Unknown
Action required: 705 - Other - as specified
Documentation › Logs/Records › Logbook (official)
Issued 10 September 1999 No resolution recorded
CREW WATCH ROTATION (CREW REST) NOT PROPERLY DOCUMENTED. SEE STCW VIII/1
Condition: Unknown
Action required: 705 - Other - as specified
Fire Fighting
Issued 10 September 1999 Resolved
EMERGENCY FIRE PUMP REQUIRED TO PROVIDE TWO STREAMS OF WATER. SEE SOLAS 74/78 II-2/4.3.1/4.2.2.
Condition: Unknown
Due 4 October 1999
Resolved 4 October 1999
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 10 September 1999 No resolution recorded
LIFE SAVING EQUIPMENT MAINT. RECORD NOT BEING MAINTAINED. SEE SOLAS 74/78 III/19.
Condition: Unknown
Action required: 705 - Other - as specified
Lifesaving › Immersion Suits › General
Issued 10 September 1999 No resolution recorded
IMMERSION SUIT LIGHTS (FLASHER TYPE) REQUIRE BATTERIES WITH EXPIRATION DATES. SEE SOLAS 74/78 II 2/20.
Condition: Unknown
Action required: 705 - Other - as specified
Fire Fighting
Issued 10 September 1999 Resolved
FIRE DRILL AND LIFE BOAT DRILL INCOMPETENT. SEE SOLAS 74/78 III/18.3.
Condition: Unknown
Due 4 October 1999
Resolved 4 October 1999
Lifesaving › Lifebuoys › Stowage
Issued 10 September 1999 No resolution recorded
LIFE BOUY QUICK RELEASE SYSTEM DOES NOT OPERATE PROPERLY. SEE SOLAS 74/78 III/7/1.
Condition: Unknown
Action required: 705 - Other - as specified
Fire Fighting
Issued 10 September 1999 Resolved
FIRE DOOR SEALS THROUGHOUT THE VESSEL REQUIRE REPAIR AND/OR REPLACEMENT AS NEEDED. SEE SOLAS 74/78/II-2/47.
Condition: Unknown
Due 10 October 1999
Resolved 4 October 1999
Construction/Loadline
Issued 19 November 1998 Resolved
REPAIR HEAVY SET-IN ON HULL NEAR STARBOARD QUARTER. _x001C_ _x001C_ CONDITION OF CLASS IMPOSED
Condition: Unknown
Due 25 January 1999
Resolved 25 January 1999
Fire Fighting
Issued 19 November 1998 Resolved
REMOVE HOLD BACK DEVICES FROM STAIR TOWER FIRE DOORS.
Condition: Unknown
Due 3 December 1998
Resolved 3 December 1998
Lifesaving
Issued 19 November 1998 Resolved
SERVICE HYDROSTATIC RELEASE DEVICE FOR LIFERAFTS.
Condition: Unknown
Due 3 December 1998
Resolved 3 December 1998
Lifesaving
Issued 19 November 1998 Resolved
PROVIDE WEAKLINK FOR LIFERAFTS. _x001C_ DOCUMENTATION PROVIDED FOR ACCEPTANCE OF RAFTS WITHOUT WEAKLINKS.
Condition: Unknown
Due 3 December 1998
Resolved 3 December 1998
Lifesaving
Issued 19 November 1998 Resolved
ENSURE VHF RADIOS REQUIRED BY SOLAS 74(AMD) III/6.2.1.1 ARE READY FOR IMMEDIATE USE.
Condition: Unknown
Due 3 December 1998
Resolved 3 December 1998
Fire Fighting
Issued 19 November 1998 Resolved
CLEAR BLOCKED ACCESS TO FIRE EXTINGUISHER AT FORECASTLE.
Condition: Unknown
Due 3 December 1998
Resolved 3 December 1998
Navigation
Issued 19 November 1998 Resolved
PROVE PROPER OPERATION OF SHIPBOARD RADAR.
Condition: Unknown
Due 3 December 1998
Resolved 3 December 1998
Navigation
Issued 19 November 1998 Resolved
PROVIDE A CURRENTLY CORRECTED CHART OF UNALASKA BAY, AK.
Condition: Unknown
Due 3 December 1998
Resolved 3 December 1998
Fire Fighting
Issued 19 November 1998 Resolved
REPAIR INOPERABLE EMERGENCY FIRE PUMP.
Condition: Unknown
Due 3 December 1998
Resolved 3 December 1998
Documentation
Issued 19 November 1998 Resolved
CONDUCT PRE-ARRIVAL TESTS WITHIN 12 HOURS OF ENTRY INTO U.S. PORT.
Condition: Unknown
Due 3 December 1998
Resolved 3 December 1998
Lifesaving
Issued 19 November 1998 Resolved
CONDUCT SATISFACTORY EMERGENCY DRILLS.
Condition: Unknown
Due 3 December 1998
Resolved 3 December 1998
Construction/Loadline
Issued 19 November 1998 Resolved
REPAIR BROKEN BULWARK NEAR PORT BOW. _x001C_ _x001C_ CONDITION OF CLASS IMPOSED
Condition: Unknown
Due 25 January 1999
Resolved 25 January 1999
Fire Fighting
Issued 19 November 1998 Resolved
RENEW FIREMAIN PIPING IN WAY OF TWO SOFT PATCHES._x001C_ _x001C_ CONDITION OF CLASS IMPOSED
Condition: Unknown
Due 25 January 1999
Resolved 25 January 1999
Accommodation/Occupational Safety
Issued 19 November 1998 Resolved
REMOVE FOOD/RICE STORED IN DECK GEAR LOCKER NEAR GALLEY AND STORE IN SANITARY LOCATION.
Condition: Unknown
Due 3 December 1998
Resolved 3 December 1998
Fire Fighting
Issued 19 November 1998 Resolved
PROVIDE FIRE EXTINGUISHING ARRANGEMENT FOR PAINT LOCKER PAINT LOCKER IAW SOLAS REQUIREMENTS.
Condition: Unknown
Due 3 December 1998
Resolved 3 December 1998
Fire Fighting
Issued 19 November 1998 Resolved
REMOVE PAINT FROM FORECASTLE AND STORE IN PAINT LOCKER.
Condition: Unknown
Due 3 December 1998
Resolved 3 December 1998
Engineering
Issued 19 November 1998 Resolved
REPAIR MAIN DIESEL ENGINE TO ENSURE PROPER OPERATION.
Condition: Unknown
Due 3 December 1998
Resolved 3 December 1998
Fire Fighting
Issued 19 November 1998 Resolved
REMOVE HOLD BACK DEVICE FROM ENGINEROOM TO DECKHOUSE FIRE DOOR.
Condition: Unknown
Due 3 December 1998
Resolved 3 December 1998
Fire Fighting
Issued 19 November 1998 Resolved
REMOVE HOLD BACK DEVICE FROM ENGINEROOM TO STEERING ROOM FIRE DOOR.
Condition: Unknown
Due 3 December 1998
Resolved 3 December 1998
Electrical
Issued 19 November 1998 Resolved
INSTALL ELECTRICAL GRADE MATING IN FRONT OF ELECTRICAL SWITCHBOARDS.
Condition: Unknown
Due 3 December 1998
Resolved 3 December 1998
Electrical
Issued 19 November 1998 Resolved
MAKE EMERGENCY GENERATOR OPERATIONAL.
Condition: Unknown
Due 3 December 1998
Resolved 3 December 1998
Electrical
Issued 19 November 1998 Resolved
REPAIR OPEN LIGHTING FIXTURE IN CREW'S WATER CLOSET.
Condition: Unknown
Due 3 December 1998
Resolved 3 December 1998
Lifesaving
Issued 25 January 1998 Resolved
RESCUE BOAT MOTOR WAS INOPERABLE.
Condition: Unknown
Due 26 February 1998
Resolved 28 January 1998
Lifesaving
Issued 25 January 1998 Resolved
THERE WAS NO EMBARKATION LADDER FOR THE RESCUE BOAT.
Condition: Unknown
Due 26 February 1998
Resolved 28 January 1998
Fire Fighting
Issued 25 January 1998 Resolved
THE PORTABLE FIREFIGHTING PUMP WAS IN-OPERABLE. THE GASOLINE PUMP WOULD NOTTAKE SUCTION.
Condition: Unknown
Due 26 February 1998
Resolved 28 January 1998
Lifesaving
Issued 25 January 1998 Resolved
THE RESCUE BOAT WASN'T STOWED IN A READY FOR USE CONDITION._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 26 February 1998
Resolved 28 January 1998
Lifesaving
Issued 13 May 1997 Resolved
SOLAS: CHAP III, REG 47.1.7 OUTBOARD ENGINE MUST BE "FITTED" TO RESCUE BOAT_x001C_ OUTBOARD ENGINE WAS STOWED IN SHIP'S ENGINE ROOM 3 DECKS BELOW, REQUIRE TWOSTRONG CREW TO HAUL TO BOAT DECK & 20 MIN TO INSTALL ONBOARD.
Condition: Unknown
Due 2 June 1997
Resolved 2 June 1997
Fire Fighting
Issued 13 May 1997 Resolved
SOLAS: CHAP II-2 REG 46.1 SELF CLOSING DOORS REQUIRED IN STAIRTOWERS._x001C_ _x001C_ SELF CLOSURE DEVICES ON 3 DOORS ACCESSING STAIRTOWER & UPPER AND LOWER DOORACCESSING ENGINE ROOM HAD BEEN DISABLED & PARTIALLY REMOVED.
Condition: Unknown
Due 2 June 1997
Resolved 2 June 1997
Fire Fighting
Issued 13 May 1997 Resolved
SOLAS: CHAP II-2 REG 47.2 HOLD-BACK HOOKS NOT ALLOWED ON SELF-CLOSING DOORS_x001C_ STAIRWAY/ENG ROOM DOORS WHICH HAD SELF CLOSURE DEVICES DISABLED OR REMOVED_x001C_HAD ALSO BEEN FITTED WITH HOLD-BACK HOOKS.
Condition: Unknown
Due 2 June 1997
Resolved 2 June 1997
Lifesaving
Issued 13 May 1997 Resolved
SOLAS: CHAP III REG 7.1.2 & 7.1.3 LIFEBUOYS WITH LINE & LIGHTS TO BE EQUALLY DISTRIBUTED ON BOTH SIDES OF THE SHIP, LIFELINES AND LIGHTS SHOULD REMAIN ATTACHED TO RINGBUOYS.
Condition: Unknown
Due 2 June 1997
Resolved 2 June 1997
Lifesaving
Issued 13 May 1997 Resolved
SOLAS: CHAP III, REG 14.1 - RESCUE BOAT STOWAGE MUST ALLOW LAUNCHING WITHIN5 MIN._x001C_ RESCUE BOAT WAS VERY SECURE, CREW OF 3-4 REQUIRED EXCESS OF 30 MIN TO UNLASH & MAKE READY FOR LAUNCHING.
Condition: Unknown
Due 2 June 1997
Resolved 2 June 1997
Lifesaving
Issued 13 May 1997 Resolved
SOLAS: CHAP III, REG 19.6.2 REQUIRED WEEKLY INSPECTION & TEST OPERATION OFRESCUE BOAT ENGINE._x001C_ ENGINE REQUIRED MINOR MAINTENANCE TO START & RUN, MASTER ACKNOWLEDGED THAT THE ENGINE HAD NOT BEEN RUN/OPERATED ON A WEEKLY BASIS.
Condition: Unknown
Due 2 June 1997
Resolved 2 June 1997
Navigation
Issued 1 February 1997 Resolved
OBTAIN CURRENT COPIES OF COAST PILOT NO. 9 AND LIGHT LIST PRIOR TO VESSEL DEPARTURE.
Condition: Unknown
Due 4 February 1997
Resolved 4 February 1997
Navigation
Issued 1 February 1997 Resolved
REPLACE BROKEN VALVE STEM ON VALVE "B" TO HAND HYDRAULIC PUMP ON STEERING SYSTEM PRIOR TO VESSEL REENTRY INTO U.S. WATERS.
Condition: Unknown
Due 9 March 1997
Resolved 9 March 1997
Navigation
Issued 1 February 1997 Resolved
MAKE CORRECTIONS OR OBTAIN CURRENT LOCAL CHARTS NO. 16530, 16528 AND 16529.
Condition: Unknown
Due 4 February 1997
Resolved 4 February 1997
Lifesaving
Issued 1 February 1997 Resolved
SERVICE TWO LIFERAFTS OR OBTAIN EXTENSION FROM FLAG ADMINISTRATION PRIOR TOVESSEL DEPARTURE FROM PORT OF DUTCH HARBOR.
Condition: Unknown
Due 4 February 1997
Resolved 4 February 1997
Lifesaving
Issued 1 February 1997 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 4 February 1997
Resolved 4 February 1997
Lifesaving
Issued 1 February 1997 Resolved
RECHARGE 2 SELF-CONTAINED BREATHING APPARATUS PRIOR TO VESSEL DEPARTURE FROM PORT OF DUTCH HARBOR, AK.
Condition: Unknown
Due 4 February 1997
Resolved 4 February 1997
Documentation
Issued 1 November 1995 Resolved
VSL COULD NOT PRODUCE SAFE MANNING DOCUMENT ISSUED BY CLASS AS PER SOLAS 74V/13
Condition: Unknown
Due 6 November 1995
Resolved 6 November 1995
Navigation
Issued 1 November 1995 Resolved
U.S. COAST PILOT WAS NOT CURRENTLY CORRECTED
Condition: Unknown
Due 3 November 1995
Resolved 3 November 1995
Navigation
Issued 1 November 1995 Resolved
TIDAL CURRENT TABLES OR EQUIVALENT NOT ON BOARD
Condition: Unknown
Due 3 November 1995
Resolved 3 November 1995
Construction/Loadline
Issued 1 November 1995 Resolved
HOLE IN BULKHEAD PORT SIDE AT FAN SPACE USED AS DRAIN FOR A/C. NO FITTING IN PLACE. SOLAS 74 II-2/42
Condition: Unknown
Due 3 November 1995
Resolved 3 November 1995
Construction/Loadline
Issued 1 November 1995 Resolved
PIPING TO SLOP TANK FROM FUEL CENTRIFUGAL SEPERATOR MISSING.
Condition: Unknown
Due 3 November 1995
Resolved 3 November 1995
Fire Fighting
Issued 1 November 1995 Resolved
E/R FIRE DOOR MISSING SELF CLOSING DEVICE AS PER SOLAS 74 II-2/47.1
Condition: Unknown
Due 2 February 1997
Resolved 2 February 1997
Deck/Cargo
Issued 1 November 1995 Resolved
PERMANENT SMALL DISCHARGE CONTAINMENT AROUND SERVICE TANK VENTS AND LUBE OIL TANK VENTS MISSING
Condition: Unknown
Due 2 February 1997
Resolved 2 February 1997
Documentation
Issued 16 July 1993 Resolved
VESSEL DID NOT HAVE ANY OIL TRANSFER PROCEDURES POSTED OR AVAILABLE IN LANGUAGE OF THE CREW AS REQUIRED BY 33 C.F.R. 155.740.
Condition: Unknown
Due 2 November 1995
Resolved 2 November 1995
Navigation
Issued 16 July 1993 Resolved
CREW FAILED TO PROPERLY POST A COMPLETE MANEUVERING FACT DATA SHEET AS REQUIRED BY 33 C.F.R. 164.35(g).
Condition: Unknown
Due 2 November 1995
Resolved 2 November 1995
Documentation
Issued 16 July 1993 Resolved
VESSEL FAILED TO HAVE OIL TRANSFER PROCEDURES ONBOARD VESSEL FOR REVIEW AS REQUIRED BY 33 C.F.R. 155.750.
Condition: Unknown
Due 2 November 1995
Resolved 2 November 1995
Documentation
Issued 16 July 1993 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 16 July 1993
Resolved 19 July 1993
Documentation
Issued 1 April 1989 Resolved
***VSL DID NOT HAVE OIL TRANSFER PROCEDURES.
Condition: Unknown
Due 2 November 1995
Resolved 2 November 1995
Navigation
Issued 1 April 1989 Resolved
***MANUEVERING FACT SHEET DID NOT CONTAIN VSL STOPPING DISTANCES AND SPEEDS.
Condition: Unknown
Due 2 November 1995
Resolved 2 November 1995

Ownership record