ENDEAVOR is a 1988 passenger vessel (inspected). The Coast Guard has recorded 80 inspections since 1988, most recently in June 2025, along with 101 deficiencies, 1 operational control and 1 casualty investigation in 2012.

Records from 1988 to 2025. Most recent: inspection, 5 June 2025.

Built
1988
Last inspected
5 June 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDI4037
305450
Flag
UNITED STATES
367694510
Maury page id
psix-305450

Inspections, by type

…with no type recorded13
Years with a record 35 calendar years (1988–2025)
The 80 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)50.0 ft × 17.0 ft × 8.0 ft
Registered tonnagegross 45 / net 36
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWESTPORT SHIPYARD, INC. · WESTPORT, WA, UNITED STATES · built 1988
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portMORRO BAY, CA
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 12 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it36 - Simplified, Net Ton
45 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDI4037MMSI 367694510 · active · compulsorily equipped · granted 16 July 2025, expires 30 September 2035
WDB6841MMSI 366931490 · expired · compulsorily equipped · granted 31 December 2013, cancelled 18 May 2024
WUY9826MMSI not assigned · cancelled · compulsorily equipped · granted 2 September 1998, cancelled 18 February 2004
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 80

5 June 2025 COI Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 8149921
29 August 2024 Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7991593
11 March 2024 Deficiency Check · Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7878022
29 February 2024 Simplified Stability Test · Administrative Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7867886
18 September 2023 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7794424
15 December 2022 Plan Review "T" Boat
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7609857
6 December 2022 Administrative Inspection · Plan Review "T" Boat
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7605290
13 September 2022 Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7541909
27 January 2022 Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7385774
1 September 2021 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7278390
9 June 2020 COI Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6972593
30 January 2020 Deficiency Check · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6899589
27 June 2019 Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6718375
5 September 2018 Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6519900
26 January 2018 Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6341592
30 August 2017 Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6255796
9 June 2016 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5896727
28 January 2016 Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5804012
23 June 2014 Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4900300
10 June 2014 COI Inspection · Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4886008
15 February 2012 Hull Examination
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4242260
7 February 2012 Deficiency Check · Damage Survey
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4239180
4 February 2012 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4240642
13 September 2011 Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4145385
10 September 2010 Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3846480
4 September 2008 Annual Inspection · Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3318650
25 April 2008 Simplified Stability Test
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3195327
16 April 2008 Hull Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3189770
21 September 2007 Deficiency Check · Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3066851
14 June 2006 Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2677863
2 May 2006 Hull Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2637761
24 May 2005 Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2362313
1 March 2005 Administrative Inspection
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2301438
11 August 2004 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2160951
26 July 2004 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2153995
29 June 2004 COI Inspection · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2113800
20 May 2004 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2157023
18 May 2004 Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2064306
10 July 2003 Administrative Inspection
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1842237
3 December 2002 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1710540
11 July 2002 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1643098
6 June 2001 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1362260
9 May 2001 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 221757
8 June 2000 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1391316
20 November 1999 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 754610
24 October 1999 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 141197
24 October 1999 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 211544
13 January 1999 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 61165
3 December 1998 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1424685
2 November 1998 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 804259
26 October 1998 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 73782
12 August 1998 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 20899
4 June 1998 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1452408
25 March 1998 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 94064
4 December 1997 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 185710
6 June 1997 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1364211
14 May 1997 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1103370
9 December 1996 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1363879
8 August 1996 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1360596
17 July 1996 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 108091
1 July 1996 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1355866
1 May 1996 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 73994
11 August 1995 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 879983
12 July 1995 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1374352
31 March 1995 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1148267
1 February 1995 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1385364
16 December 1994 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1449755
4 August 1994 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1374120
27 June 1994 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1448559
2 July 1993 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 842370
15 December 1992 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1142004
8 July 1992 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 948131
19 July 1991 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1246870
7 May 1991 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 926023
10 July 1990 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 901347
4 December 1989 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1243212
24 August 1989 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1037838
13 July 1989 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 889031
25 July 1988 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1038016
19 July 1988 Initial Certification
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1033141

Deficiency record · 101

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 September 2023 Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck. Stbd fuel oil shutoff valve was inoperable from weather deck and local operation. Upon further investigation by operator, both valves were found inoperable. 46 CFR 182.455(b)(4)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 September 2023
Resolution: Vessel replaced valves.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 18 September 2023 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces: A space with a non-watertight closure, such as a space with a non-watertight hatch on the main deck. Fwd void bilge high level float did not alarm at operating station upon actuation. 46 CFR 182.530(a)(3)
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 October 2023
Resolved 12 October 2023
Resolution: Received video verification of properly functioning high water alarm.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 18 September 2023 Resolved
Electrical equipment on a vessel must be installed and maintained to: (a) Provide services necessary for safety under normal and emergency conditions. Aft machinery light was extinguished and did not adequately illuminate the space. 46 CFR 183.200(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 October 2023
Resolved 12 October 2023
Resolution: Received photos of newly installed light.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 18 September 2023 Resolved
Independent fuel tanks must be located and installed as described in this paragraph (b). All fuel tanks must be electrically bonded to a common ground. Fuel tank was grounded to fuel oil shutoff deck access covers not to a common ground. 46 CFR 182.440(b)(4)
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 October 2023
Resolved 12 October 2023
Resolution: Fuel tank grounding re-routed to common ground.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 18 September 2023 Resolved
Each survival craft must be: Stowed so that when the vessel sinks the survival craft floats free and, if inflatable, inflates automatically. IBA sea painter was not attached to weak link.46 CFR 180.130(a)(2)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 18 September 2023
Resolution: Sea painter was properly attached during inspection.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 13 September 2022 Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI. Vessel's testing devices were expired. Until such time that valid testing devices are available onboard,vessel must stay within 2 hours of a location to perform the required alcohol tests from the time of occurrence of the SMI. Vessel will need to replace testing devices as required and or show written policy attesting to how the vessel will obtain the devices and conduct the required alcohol tests within 2 hours from the time of occurrence of the SMI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 September 2022
Resolved 16 September 2022
Resolution: Vessel has replaced testing devices as required.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 1 September 2021 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each normally unmanned spaces. Vessel's high water level bilge alarms were not operable. Repair to satisfaction of attending Marine Inspector.
Action required: 10 - Deficiency Rectified
Resolved 1 September 2021
Resolution: Repaired to satisfaction of attending Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 September 2021 Resolved
Each ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant. Retro reflective material was wasted on ring life buoy. Replace/repair ring life buoy to satisfaction of attending Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 September 2021
Resolved 9 September 2021
Resolution: Replaced ring life buoy to satisfaction of attending Marine Inspector.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 1 September 2021 Resolved
The emergency instructions required by 46 CFR 185.510 must be designed to address the particular equipment, arrangement, and operation of each individual vessel. Vessel does not conduct Man-overboard procedures as dictated on posted emergency instructions. Amend emergency instructions to address the particular operation of the vessel and provide to attending Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 September 2021
Resolved 4 October 2021
Resolution: Removed portion of emergency procedures referring to placing crewmember in water.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 30 January 2020 Resolved
A vessel that is exposed to salt water for more than three months in any 12 month period must undergo a drydock examination and internal structural at least every two years. Vessel due for drydock and internal examination on 31JAN2020. Vessel prohibited from carriage of passengers or cargo until drydock and internal structural examinations have been completed to the satisfaction of attending USCG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 February 2020
Resolution: Vessel completed hull exm.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 27 June 2019 Resolved
Clean or replace running light lenses.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 July 2019
Resolved 8 July 2019
Resolution: Vessel replaced lenses on both running lights.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 27 June 2019 Resolved
Provide current coast pilot, light list, tides/currents, and charts.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 July 2019
Resolved 3 July 2019
Resolution: Vessel provided downloaded publications on board.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 27 June 2019 Resolved
Incorrect MMSI programmed into DSC VHF radio. Program correct MMSI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 July 2019
Resolved 3 July 2019
Resolution: Vessel demonstrated input of correct MMSI.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 27 June 2019 Resolved
Mark fuel oil shutoff valve locations.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 July 2019
Resolved 3 July 2019
Resolution: Vessel marked F/O shutoff valve locations.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 30 August 2017 Resolved
Provide a portable fire extinguisher in the E/R.
Action required: 705 - Other - as specified
Due 30 August 2017
Resolved 30 August 2017
Resolution: New portable fire extinguisher installed the same day.
Navigation › Piloting/Steering › US Coast Pilot
Issued 30 August 2017 Resolved
Provide updated pubs (coast pilot, light light, tide tables) hard copy or electronic.
Action required: 705 - Other - as specified
Due 30 September 2017
Resolved 11 September 2017
Resolution: Electronic pubs provided.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 30 August 2017 Resolved
Update first aid kit IAW 46 CFR 160.041.
Action required: 705 - Other - as specified
Due 30 September 2017
Resolved 11 September 2017
Resolution: New lifeboat first aid kit provided.
Communications › Radio Communications › EPIRB
Issued 9 June 2016 Resolved
Prior to carrying psgrs >3NM, provide proof of current EPIRB registration.
Condition: Invalid
Action required: 705 - Other - as specified
Due 10 June 2016
Resolved 6 July 2016
Resolution: EPIRB registered will NOAA to expire 09JUN18.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 9 June 2016 Resolved
Establish drug/alcohol policy
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 9 July 2016
Resolved 6 July 2016
Resolution: Drug and alcohol policy established.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 9 June 2016 Resolved
Master must complete 1-hr supervisory training.
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 July 2016
Resolved 6 July 2016
Resolution: Supervisory training completed.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 9 June 2016 Resolved
Replace alco-testers NLT 01JUL16
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 July 2016
Resolved 6 July 2016
Resolution: New alco testers on board.
Electrical › Electrical Distribution System (service) › Switch
Issued 9 June 2016 Resolved
Replace E/R light switch.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 9 July 2016
Resolved 6 July 2016
Resolution: E/R light switch replaced.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 9 June 2016 Resolved
Replace cover on receptacle near galley sink.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 9 July 2016
Resolved 6 July 2016
Resolution: Cover replaced on outlet.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 9 June 2016 Resolved
Install 2nd hose clamp on fuel shut-off valve.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 July 2016
Resolved 6 July 2016
Resolution: 2nd hose clamp installed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 9 June 2016 Resolved
Laz: clean terminal block & connections.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 July 2016
Resolved 6 July 2016
Resolution: Terminal block cleaned in laz.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 9 June 2016 Resolved
Post EAP 800 number in a location accessible to all crewmembers.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 June 2016
Resolved 9 June 2016
Resolution: EAP number posted.
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 9 June 2016 Resolved
Provide suitable storage location for combustible liquids or remove from vessel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 June 2016
Resolved 9 June 2016
Resolution: Combustibles removed from vessel.
Engineering › Steering Gear System › Rudder Stock
Issued 28 January 2016 Resolved
Repack rudder shaft seal.
Action required: 705 - Other - as specified
Due 28 February 2016
Resolved 9 February 2016
Construction/Loadline › Structures › End Bulkhead
Issued 28 January 2016 Resolved
Make the collision bulkhead water tight in way of the access plate.
Action required: 705 - Other - as specified
Due 28 February 2016
Resolved 9 February 2016
Engineering › Sea-water System (primary cooling) › Piping
Issued 28 January 2016 Resolved
Double clamp the hose connection to the port through-hull valve.
Action required: 705 - Other - as specified
Due 28 February 2016
Resolved 9 February 2016
Operations/Management › Equipment Service/Testing › EPIRB
Issued 10 June 2014 Resolved
EPIRB failed to meet the applicable requirements. Replace expired hydrostatic release & expired EPIRB battery.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 July 2014
Resolved 10 June 2014
Resolution: Corrected on the spot. Upon noticing discrepancy, Master had the deckhand run Englund Marine to purchase a new EPIRB. Within 1hr discrepancy was corrected.
Construction/Loadline › Hull › Keel
Issued 6 February 2012 Resolved
Make vessel available for hull inspection prior to the carriage of passengers. This item to be completed to the satisfaction of the attending Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 6 March 2012
Resolved 7 February 2012
Resolution: Vessel made available at drydock for inspection to the satisfaction of Marine Inspector.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 4 September 2008 Resolved
Provide two alcohol test kits.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 September 2008
Operations/Management › Drills/Instruction › Not Conducted
Issued 4 September 2008 Resolved
Conduct MOB and Fire drills with new crewmember and log in vessels logbook.
Due 8 September 2008
Resolved 11 September 2008
Communications › Radio Communications › EPIRB
Issued 4 September 2008 Resolved
Provide new hydrostatic release for EPIRB.
Due 8 September 2008
Resolved 11 September 2008
Navigation › Piloting/Steering › US Coast Pilot
Issued 4 September 2008 Resolved
Provide updated publications.
Due 12 September 2008
Resolved 11 September 2008
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 21 September 2007 Resolved
Provide two alcohol test kits onboard vessel prior to operating with passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 September 2007
Lifesaving › Lifefloat › Retroreflective Material
Issued 21 September 2007 Resolved
Replace retro-reflective tape on life ring and life float.
Due 28 September 2007
Resolved 9 October 2007
Resolution: Received phone call from [name withheld] stating that the retro-reflective material on the life-ring and life-float has been replaced.
Communications › Alarms/Indicators › Bilge Alarm
Issued 21 September 2007 Resolved
Prove proper operation of bilge high level alarms. Crew required to make 30 min. rounds of all spaces until proper operation of bilge alarms can be proven to Coast Guard Marine Inspector. All rounds must be logged in the vessels log until proper operation is proven to Coast Guard. Alarms must be fixed no later than 24 Sept. 2007.
Due 24 September 2007
Resolved 21 September 2007
Communications › Radio Communications › EPIRB
Issued 21 September 2007 Resolved
Replace battery in EPIRB. Vessel restricted to less than 3 NM until properly repaired.
Due 28 September 2007
Resolved 24 September 2007
Fire Fighting › Portable CO2 Fire Extinguisher › Pressure
Issued 21 September 2007 Resolved
Replace/Recharge one B-II portable fire extinguisher prior to operating with passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 September 2007
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 21 September 2007 Resolved
Replace outdated items in first aid kit.
Due 5 October 2007
Resolved 9 October 2007
Resolution: Received phone call from [name withheld] stating that all outdated first aid kit items have been replaced.
Engineering › Bilge Water Management System › Pump
Issued 21 September 2007 Resolved
Prove proper operation of bilge pump prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 September 2007
Resolution: Items cleared via faxed letter from vessel operator. Proper operation will be visually confirmed during next visit to area. Signed letter attached to Activity.
Communications › Radio Communications › EPIRB
Issued 29 June 2004 Resolved
Provide new EPIRB (new registration required). Provide NOAA registration date, hydrostatic release exp. date, and EPIRB battery exp. date. 46 CFR 180.64 Vessel is ltd to operating NMT 3 miles from shore.
Condition: Improper/Lack of Maintenance
Due 29 July 2004
Resolved 2 July 2004
Resolution: New antenna installed.
Stability › Watertight Integrity › General
Issued 29 June 2004 Resolved
Renew bait box drain hose (old RULE pump hose) in lazarette. Hose is to meet 46 CFR 182.520 (f).
Due 29 July 2004
Resolved 2 July 2004
Resolution: New hose installed.
Construction/Loadline › Structures › Deck Plating
Issued 29 June 2004 Resolved
Provide mechanical fastening for outboard (P&S) ends of underdeck strongbacks in way of aft main deck soft patch in lazarette (above the fuel tanks). 46 CFR 177.300
Due 29 July 2004
Resolved 2 July 2004
Resolution: Corrected.
Electrical › Electrical Distribution System (service) › Wiring
Issued 29 June 2004 Resolved
Repair/renew electrical supply terminals for aft compt. sub-bilge pump. 46 CFR 183.340
Condition: Improper/Lack of Maintenance
Due 29 July 2004
Resolved 2 July 2004
Resolution: Corrected.
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 29 June 2004 Resolved
Replace both fuel tank vent screens with 30 X 30 mesh, corrosion resistant, metallic vent screens. (Presently fitted with 20 X 20 mesh with gaps larger than vent openings) 46 CFR 182.450 (e)
Condition: Improper Installation
Due 29 July 2004
Resolved 2 July 2004
Resolution: Corrected.
Electrical › Electrical Distribution System (service) › Wiring
Issued 29 June 2004 Resolved
Replace power supply cable (presently orange colored elect. extension cord) for potable water pump, sewage overboard pump, and wash-down pump (and any others not noted) with cable meeting 46 CFR 183.340. (A jumper cable perm. installed to a 110 VAC invertor was also noted to master)
Condition: Improper Installation
Due 29 July 2004
Resolved 2 July 2004
Resolution: New and proper wire installed.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 29 June 2004 Resolved
Remove/relocate handle for sewage overboard valve or secure in "closed" position with a tamper-resistant device. 33 CFR 154
Condition: Improper Installation
Due 29 July 2004
Resolved 2 July 2004
Resolution: Corrected.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 29 June 2004 Resolved
Prove proper operation of the automatic shut-down (and reset) devices for both main diesel engines upon discharge of the fixed fire extinguishing system. 46 CFR 181.420 (a) Must be completed prior to the carriage of passengers.
Condition: Improper Installation
Due 29 July 2004
Resolved 2 July 2004
Resolution: Corrected.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 29 June 2004 Resolved
Install guards around exposed flywheel/accessory pullies in front of both main diesel engines. 46 CFR 177.960
Condition: Improper Installation
Due 29 July 2004
Resolved 26 July 2004
Resolution: Corrected.
Engineering › Fuel Oil Service System › Filter
Issued 29 June 2004 Resolved
Remove petcock drain valves from both Racor fuel filters and replace with either solid plugs or solid-body drain valve fitted with a plug or cap. 46 CFR 182.455(b) (9).
Condition: Improper Installation
Due 29 July 2004
Resolved 2 July 2004
Resolution: Corrected.
Navigation › Collision/Grounding Avoidance › Radar
Issued 29 June 2004 Resolved
Prove proper operation of radar (presently won't orient proper heads-up display). 46 CFR 184.404 The vessel may not carry passengers on voyages off-shore until corrected.
Condition: Improper Installation
Due 29 July 2004
Resolved 2 July 2004
Resolution: Corrected.
Operations/Management › Drills/Instruction › Fire
Issued 29 June 2004 Resolved
Demonstrate to attending CG marine inspector, satisfactory fire and man-overboard drills. 46 CFR 185.520
Due 31 August 2004
Resolved 11 August 2004
Resolution: Conducted drills. All sat.
Operations/Management › Passenger Operations › Safety Orientation
Issued 11 May 2004 Resolved
Vessel must undergo an Inspection for Certification as a "New to Zone" operation prior to operating certificated. Complete to the satisfaction of the attending marine inspector. LEGACY COMPONENT DESC: Inspection ofr Certification-NTZ
Due 25 June 2004
Resolved 29 June 2004
Construction/Loadline › Hull
Issued 3 December 2002 Resolved
Repair blisters on exterior of under water hull.
Action required: 705 - Other - as specified
Resolved 5 December 2002
Engineering › Shafting/Propeller Arrangements › Stern Tube Bearing
Issued 3 December 2002 Resolved
Replace cutlass bearings on both shafts (total of 4).
Action required: 705 - Other - as specified
Resolved 5 December 2002
Engineering › Bilge Water Management System › Piping
Issued 3 December 2002 Resolved
Install suction strainers on all bilge pump piping.
Action required: 705 - Other - as specified
Resolved 5 December 2002
Engineering › Bilge Water Management System
Issued 3 December 2002 Resolved
Permanently mount submersable bilge pumps.
Action required: 705 - Other - as specified
Resolved 5 December 2002
Communications › Alarms/Indicators › Bilge Alarm
Issued 3 December 2002 Resolved
Permanently mount float switches for bilge high level alarms.
Action required: 705 - Other - as specified
Resolved 5 December 2002
Personnel › Certificates/Documents/Licenses
Issued 11 July 2002 Resolved
Missing CPR cards. LEGACY COMPONENT DESC: Certificate, CPR Course Completion
Condition: Unknown
Due 11 July 2002
Resolved 11 July 2002
Engineering › Bilge Water Management System
Issued 11 July 2002 Resolved
Visual indicator for high water alarm OOC. LEGACY COMPONENT DESC: High water alarm, visual
Condition: Unknown
Due 11 July 2002
Resolved 11 July 2002
Engineering › Fuel Oil Storage/Transfer System
Issued 11 July 2002 Resolved
Make proper repairs to fuel tank IAW 46CFR176.700. LEGACY COMPONENT DESC: Tank
Due 18 July 2002
Resolved 5 December 2002
Engineering › Fuel Oil Storage/Transfer System
Issued 11 July 2002 Resolved
Missing 30x30 mesh screen for starboard fuel vent. LEGACY COMPONENT DESC: Vent Pipe
Condition: Unknown
Due 11 July 2002
Resolved 11 July 2002
Documentation › Manuals/Policy Documentation
Issued 11 July 2002 Resolved
Missing waste management plan. LEGACY COMPONENT DESC: waste managment plan
Condition: Unknown
Due 18 July 2002
Resolved 11 July 2002
Lifesaving › Buoyant Apparatus
Issued 11 July 2002 Resolved
Waterlight OOC. LEGACY COMPONENT DESC: Waterlight
Condition: Unknown
Due 11 July 2002
Resolved 11 July 2002
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 11 July 2002 Resolved
Rejected two adult lifejackets. Lifejackets tore apart easily without effort.
Condition: Unknown
Due 11 July 2002
Resolved 11 July 2002
Engineering › Fuel Oil Storage/Transfer System
Issued 11 July 2002 Resolved
Make proper repair to mounting bracket for fuel tank starboard side IAW46CFR182.440(b)(3). LEGACY COMPONENT DESC: Tank
Condition: Unknown
Due 18 July 2002
Resolved 5 December 2002
Lifesaving
Issued 1 July 1996 Resolved
Provide log and conduct man overboard/abandon ship drills and training as per IFR 46 CFR 185.520.
Condition: Unknown
Due 1 July 1996
Resolved 1 July 1996
Fire Fighting
Issued 1 July 1996 Resolved
Provide log and conduct firefighting drills and training as per IFR 46 CFR 185.524.
Condition: Unknown
Due 1 July 1996
Resolved 1 July 1996
Lifesaving
Issued 1 July 1996 Resolved
Provide log and conduct weekly maintenance asper IFR 46 CFR 185.720.
Condition: Unknown
Due 1 July 1996
Resolved 1 July 1996
Lifesaving
Issued 1 July 1996 Resolved
Provide log and conduct quarterly maintenance as per IFR 46 CFR 185.722.
Condition: Unknown
Due 1 July 1996
Resolved 1 July 1996
Construction/Loadline
Issued 1 July 1996 Resolved
Provide positive means to secure overboard discharge from electric submersible pumps as per IFR 46 CFR 182.520(e)(7).
Condition: Unknown
Due 1 July 1996
Resolved 1 July 1996
Lifesaving
Issued 1 July 1996 Resolved
Provide log and conduct emergency training as per IFR 46 CFR 185.420.
Condition: Unknown
Due 1 July 1996
Resolved 1 July 1996
Engineering
Issued 1 July 1996 Resolved
Provide metal drip pans for RACOR fuel filters as per 46 CFR 182.20- 40(b)(5).
Condition: Unknown
Due 1 July 1996
Resolved 1 July 1996
Engineering
Issued 1 July 1996 Resolved
Mark emergency fuel shutoffs with direction of operation.
Condition: Unknown
Due 1 July 1996
Resolved 1 July 1996
Fire Fighting
Issued 12 July 1995 Resolved
Replace corroded accomodation space forward port portable fire extinguisherwith properly serviced B-II portable extinguisher.
Condition: Unknown
Due 12 August 1995
Resolved 25 August 1995
Engineering
Issued 12 July 1995 Resolved
Replace or renew broken valve handle for port emergency fuel shutoff valve and prove proper operation.
Condition: Unknown
Due 12 August 1995
Resolved 25 August 1995
Lifesaving
Issued 12 July 1995 Resolved
Renew or replace forward buoyant apparatus with CG approved buoyant apparatus and provide proper markings.
Condition: Unknown
Due 12 July 1995
Resolved 25 August 1995
Fire Fighting
Issued 1 February 1995 Resolved
BRING FIXED HALON FIRE EXTINGUISHING SYSTEM FOR THE ENGINE ROOM INTO COMPLIANCE WITH 46 CFR 162.029. INCLUDING MANUAL PULL CABLE, ENGINE AND VENTILATION SHUTDOWNS, SYSTEM INDICATOR LIGHT AT THE OPERATING STATION AND APPLICABLE WARNING SIGNS.
Condition: Unknown
Due 1 February 1995
Resolved 1 February 1995
Electrical
Issued 16 December 1994 Resolved
REPLACE LIGHT FIXTURE IN STORAGE COMPARTMENT FORWARD OF STEERING/FUEL TANK COMPARTMENT WITH AN APPROVED MARINE LIGHT FIXTURE.
Condition: Unknown
Due 16 December 1994
Resolved 16 December 1994
Construction/Loadline
Issued 16 December 1994 Resolved
REPLACE GASKET TO AFT HATCH COVER TO STEERING/FUEL TANK COMPARTMENT.
Condition: Unknown
Due 16 December 1994
Resolved 16 December 1994
Lifesaving
Issued 27 June 1994 Resolved
PROPERLY STENCIL VESSEL'S NAME ON EPIRB.
Condition: Unknown
Due 27 June 1994
Resolved 27 June 1994
Engineering
Issued 27 June 1994 Resolved
MOUNT EMERGENCY FUEL SHUTOFF PLACARD AND PROVIDE EASILY ACCESSIBLE KEY TO OPEN COVER FOR REMOTE FUEL SHUTOFF VALVES.
Condition: Unknown
Due 27 June 1994
Resolved 27 June 1994
Construction/Loadline
Issued 27 June 1994 Resolved
PROVIDE/INSTALL KEEPER CHAINS ON ALL 3 HATCHES EXPOSED TO WEATHER.
Condition: Unknown
Due 27 June 1994
Resolved 27 June 1994
Fire Fighting
Issued 27 June 1994 Resolved
PROPERLY SERVICE FIXED FIRE EXTINGUISHING SYSTEM.
Condition: Unknown
Due 27 June 1994
Resolved 27 June 1994
Lifesaving
Issued 27 June 1994 Resolved
RENEW OUTDATED EPIRB BATTERY.
Condition: Unknown
Due 27 June 1994
Resolved 27 June 1994
Engineering
Issued 27 June 1994 Resolved
TIGHTEN OR RENEW PACKING ON STARBOARD SHAFT.
Condition: Unknown
Due 27 June 1994
Resolved 27 June 1994
Electrical
Issued 27 June 1994 Resolved
REPLACE GLOBES FOR LIGHTS IN DIVE EQUIPMENT COMPARTMENT AND ENGINE ROOM.
Condition: Unknown
Due 27 June 1994
Resolved 27 June 1994
Electrical
Issued 27 June 1994 Resolved
REMOUNT LIGHT IN ENGINE ROOM.
Condition: Unknown
Due 27 June 1994
Resolved 27 June 1994
Electrical
Issued 27 June 1994 Resolved
REMOVE ALLIGATOR CLIPPED HARD WIRING FROM BATTERY.
Condition: Unknown
Due 27 June 1994
Resolved 27 June 1994
Electrical
Issued 27 June 1994 Resolved
RENEW ELECTRICAL JUNCTION BOXES IN AFT STORAGE COMPARTMENT AND IN AFTER STEERING.
Condition: Unknown
Due 27 June 1994
Resolved 27 June 1994
Electrical
Issued 27 June 1994 Resolved
PROPERLY SECURE WIRING IN AFT STEERING.
Condition: Unknown
Due 27 June 1994
Resolved 27 June 1994
Navigation
Issued 8 July 1992 Resolved
RENEW THE STERN RUNNING LIGHT.
Condition: Unknown
Due 30 July 1992
Resolved 29 July 1992
Engineering
Issued 10 July 1990 Resolved
REPLACE PACKING ON PORT AND STBD PACKING GLANDS OR ADJUST TO ELIMINATE EXCESSIVE LEAKING.
Condition: Unknown
Due 10 July 1990
Resolved 10 July 1990
Navigation
Issued 4 December 1989 Resolved
DOUBLE NUT OR DRILL AND PIN STEERING ASSEMBLY PRIOR TO CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 4 December 1989
Resolved 4 December 1989
Navigation
Issued 4 December 1989 Resolved
MAKE PORT AND STARBOARD RUDDER QUADRANT AVAILABLE FOR INSPECTION AFTER INSTALLATION.
Condition: Unknown
Due 4 December 1989
Resolved 4 December 1989
Engineering
Issued 13 July 1989 Resolved
REPLACE THE PORT EMERGENCY FUEL SHUTDOWN VALVE.
Condition: Unknown
Due 13 July 1989
Resolved 13 July 1989
Fire Fighting
Issued 19 July 1988 Resolved
PROVIDE VENTILATION CLOSURES FOR ALL VENTILATION OPENINGS SERVING THE ENGINE COMPARTMENT.
Condition: Unknown
Due 19 July 1988
Resolved 19 July 1988
Unknown
Issued 19 July 1988 Resolved
THE OFFICER IN CHARGE, MARINE INSPECTIONS, HONOLULU, HAWAII, SHALL BE CONTACTED BEFORE THE VESSEL CARRIES PASSENGERS FOR HIRE.
Condition: Unknown
Due 19 July 1988
Resolved 19 July 1988

Casualty record · 1

4 February 2012Routine · role: Involved in a Marine Casualty · activity 4240642
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.