Inspection history · 18
5 June 2025
COI Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 8149921
29 August 2024
Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7991593
11 March 2024
Deficiency Check · Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7878022
29 February 2024
Simplified Stability Test · Administrative Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7867886
18 September 2023
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7794424
15 December 2022
Plan Review "T" Boat
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7609857
6 December 2022
Administrative Inspection · Plan Review "T" Boat
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7605290
13 September 2022
Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7541909
27 January 2022
Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7385774
1 September 2021
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7278390
9 June 2020
COI Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6972593
30 January 2020
Deficiency Check · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6899589
27 June 2019
Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6718375
5 September 2018
Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6519900
26 January 2018
Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6341592
30 August 2017
Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6255796
9 June 2016
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5896727
28 January 2016
Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5804012
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 September 2023
Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck. Stbd fuel oil shutoff valve was inoperable from weather deck and local operation. Upon further investigation by operator, both valves were found inoperable. 46 CFR 182.455(b)(4)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 September 2023
Resolution: Vessel replaced valves.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 18 September 2023
Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces: A space with a non-watertight closure, such as a space with a non-watertight hatch on the main deck. Fwd void bilge high level float did not alarm at operating station upon actuation. 46 CFR 182.530(a)(3)
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 October 2023
Resolved 12 October 2023
Resolution: Received video verification of properly functioning high water alarm.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 18 September 2023
Resolved
Electrical equipment on a vessel must be installed and maintained to: (a) Provide services necessary for safety under normal and emergency conditions. Aft machinery light was extinguished and did not adequately illuminate the space. 46 CFR 183.200(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 October 2023
Resolved 12 October 2023
Resolution: Received photos of newly installed light.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 18 September 2023
Resolved
Independent fuel tanks must be located and installed as described in this paragraph (b). All fuel tanks must be electrically bonded to a common ground. Fuel tank was grounded to fuel oil shutoff deck access covers not to a common ground. 46 CFR 182.440(b)(4)
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 October 2023
Resolved 12 October 2023
Resolution: Fuel tank grounding re-routed to common ground.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 18 September 2023
Resolved
Each survival craft must be: Stowed so that when the vessel sinks the survival craft floats free and, if inflatable, inflates automatically. IBA sea painter was not attached to weak link.46 CFR 180.130(a)(2)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 18 September 2023
Resolution: Sea painter was properly attached during inspection.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 13 September 2022
Resolved
The marine employer must have a sufficient number of
alcohol testing devices readily accessible on board the
vessel to determine the presence of alcohol in the
system of each individual who was directly involved in
the SMI. Vessel's testing devices were expired. Until
such time that valid testing devices are available
onboard,vessel must stay within 2 hours of a location to
perform the required alcohol tests from the time of
occurrence of the SMI. Vessel will need to replace
testing devices as required and or show written
policy attesting to how the vessel will obtain the
devices and conduct the required alcohol tests within 2
hours from the time of occurrence of the SMI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 September 2022
Resolved 16 September 2022
Resolution: Vessel has replaced testing devices as required.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 1 September 2021
Resolved
On a vessel of at least 7.9 meters (26 feet) in length,
a visual and audible alarm must be provided at the
operating station to indicate a high water level in each
normally unmanned spaces. Vessel's high water level
bilge alarms were not operable. Repair to satisfaction
of attending Marine Inspector.
Action required: 10 - Deficiency Rectified
Resolved 1 September 2021
Resolution: Repaired to satisfaction of attending Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 September 2021
Resolved
Each ring life buoy must be marked with Type II
retroreflective material approved in accordance with 46
CFR 164.018 or other standard specified by the
Commandant. Retro reflective material was wasted on ring
life buoy. Replace/repair ring life buoy to satisfaction
of attending Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 September 2021
Resolved 9 September 2021
Resolution: Replaced ring life buoy to satisfaction of attending Marine Inspector.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 1 September 2021
Resolved
The emergency instructions required by 46 CFR 185.510
must be designed to address the particular equipment,
arrangement, and operation of each individual vessel.
Vessel does not conduct Man-overboard procedures as
dictated on posted emergency instructions. Amend
emergency instructions to address the particular
operation of the vessel and provide to attending Marine
Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 September 2021
Resolved 4 October 2021
Resolution: Removed portion of emergency procedures referring to placing crewmember in water.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 30 January 2020
Resolved
A vessel that is exposed to salt water for more than three months in any 12 month period must undergo a drydock examination and internal structural at least every two years. Vessel due for drydock and internal examination on 31JAN2020. Vessel prohibited from carriage of passengers or cargo until drydock and internal structural examinations have been completed to the satisfaction of attending USCG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 February 2020
Resolution: Vessel completed hull exm.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 27 June 2019
Resolved
Clean or replace running light lenses.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 July 2019
Resolved 8 July 2019
Resolution: Vessel replaced lenses on both running lights.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 27 June 2019
Resolved
Provide current coast pilot, light list, tides/currents, and charts.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 July 2019
Resolved 3 July 2019
Resolution: Vessel provided downloaded publications on board.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 27 June 2019
Resolved
Incorrect MMSI programmed into DSC VHF radio. Program correct MMSI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 July 2019
Resolved 3 July 2019
Resolution: Vessel demonstrated input of correct MMSI.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 27 June 2019
Resolved
Mark fuel oil shutoff valve locations.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 July 2019
Resolved 3 July 2019
Resolution: Vessel marked F/O shutoff valve locations.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 30 August 2017
Resolved
Provide a portable fire extinguisher in the E/R.
Action required: 705 - Other - as specified
Due 30 August 2017
Resolved 30 August 2017
Resolution: New portable fire extinguisher installed the same day.
Navigation › Piloting/Steering › US Coast Pilot
Issued 30 August 2017
Resolved
Provide updated pubs (coast pilot, light light, tide tables) hard copy or electronic.
Action required: 705 - Other - as specified
Due 30 September 2017
Resolved 11 September 2017
Resolution: Electronic pubs provided.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 30 August 2017
Resolved
Update first aid kit IAW 46 CFR 160.041.
Action required: 705 - Other - as specified
Due 30 September 2017
Resolved 11 September 2017
Resolution: New lifeboat first aid kit provided.
Communications › Radio Communications › EPIRB
Issued 9 June 2016
Resolved
Prior to carrying psgrs >3NM, provide proof of current EPIRB registration.
Condition: Invalid
Action required: 705 - Other - as specified
Due 10 June 2016
Resolved 6 July 2016
Resolution: EPIRB registered will NOAA to expire 09JUN18.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 9 June 2016
Resolved
Establish drug/alcohol policy
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 9 July 2016
Resolved 6 July 2016
Resolution: Drug and alcohol policy established.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 9 June 2016
Resolved
Master must complete 1-hr supervisory training.
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 July 2016
Resolved 6 July 2016
Resolution: Supervisory training completed.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 9 June 2016
Resolved
Replace alco-testers NLT 01JUL16
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 July 2016
Resolved 6 July 2016
Resolution: New alco testers on board.
Electrical › Electrical Distribution System (service) › Switch
Issued 9 June 2016
Resolved
Replace E/R light switch.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 9 July 2016
Resolved 6 July 2016
Resolution: E/R light switch replaced.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 9 June 2016
Resolved
Replace cover on receptacle near galley sink.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 9 July 2016
Resolved 6 July 2016
Resolution: Cover replaced on outlet.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 9 June 2016
Resolved
Install 2nd hose clamp on fuel shut-off valve.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 July 2016
Resolved 6 July 2016
Resolution: 2nd hose clamp installed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 9 June 2016
Resolved
Laz: clean terminal block & connections.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 July 2016
Resolved 6 July 2016
Resolution: Terminal block cleaned in laz.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 9 June 2016
Resolved
Post EAP 800 number in a location accessible to all crewmembers.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 June 2016
Resolved 9 June 2016
Resolution: EAP number posted.
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 9 June 2016
Resolved
Provide suitable storage location for combustible liquids or remove from vessel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 June 2016
Resolved 9 June 2016
Resolution: Combustibles removed from vessel.
Engineering › Steering Gear System › Rudder Stock
Issued 28 January 2016
Resolved
Repack rudder shaft seal.
Action required: 705 - Other - as specified
Due 28 February 2016
Resolved 9 February 2016
Construction/Loadline › Structures › End Bulkhead
Issued 28 January 2016
Resolved
Make the collision bulkhead water tight in way of the access plate.
Action required: 705 - Other - as specified
Due 28 February 2016
Resolved 9 February 2016
Engineering › Sea-water System (primary cooling) › Piping
Issued 28 January 2016
Resolved
Double clamp the hose connection to the port through-hull valve.
Action required: 705 - Other - as specified
Due 28 February 2016
Resolved 9 February 2016