Records from 2016 to 2026. Most recent: inspection, 10 February 2026.
Inspection history · 19
10 February 2026
Annual Inspection · Vessel Attendance
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8308351
10 June 2025
Drydock Exam · Internal Structural Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8156674
25 February 2025
In-Service Inspection · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8085258
16 January 2025
Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8064058
18 August 2024
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7989659
24 June 2024
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7941201
24 May 2024
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7921863
30 January 2024
Deficiency Check · In-Service Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7846572
22 January 2024
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7852556
6 November 2023
COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7820854
24 February 2023
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7641293
23 January 2023
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7625661
24 January 2022
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7384489
21 October 2021
Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7337191
16 April 2021
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7176813
26 January 2021
Administrative Inspection · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7131707
22 January 2020
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6891411
17 October 2018
Deficiency Check · Drydock Exam · COI Inspection · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6563600
26 July 2016
Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5954448
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 30 January 2024
Resolved
The installation of fuel lines, including pipe, tube, and hose, must comply with the requirements of this paragraph. A suitable metal marine type strainer, meeting the requirements of the engine manufacturer, must be fitted in the fuel supply line in the engine compartment.
Fuel filter separator bowl not installed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 February 2024
Resolved 22 February 2024
Resolution: Separator bowls installed on all P/S engine and generator separators.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 January 2024
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets.
Adult and child life jackets were not separated.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 February 2024
Resolved 20 February 2024
Resolution: Adult/child life jackets are separated.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 January 2023
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. The lifebuoy on the upper deck was deteriorated and needs to be replaced.
46 CFR 176.808(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 February 2023
Resolution: Received photo evidence of a new lifebuoy.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 January 2023
Resolved
Each item of lifesaving equipment with an expiration date on it must be replaced if the expiration date has passed. The battery for the float light attached to the life buoy on the bottom deck was expired.
46 CFR 176.808(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 February 2023
Resolution: Received photo evidence the vessel purchased three new batteries.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 January 2023
Resolved
Each life jacket must be marked with Type I retroreflective material approved in 46 CFR 164.018 or other standard specified by the Commandant. Numerous life jackets had wasted retroreflective material that needs to be replaced.
46 CFR 180.25-25(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 February 2023
Resolution: Received photo evidence the vessel replaced retro on the life jackets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 January 2023
Resolved
Life Preservers for children shall be stowed separately. Child life jackets were stowed together with adult life jackets.
46 CFR 180.25-10(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 February 2023
Resolution: Received photo evidence there was a barrier placed between the adult and child life jackets.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 January 2023
Resolved
Propulsion machinery shall be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its design limits. The starboard engine had cooling water dripping from the hose attached at the aft part of the engine.
46 CFR 182.05-1
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 February 2023
Resolution: Received photo evidence the hose clamp was replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 January 2022
Resolved
The light must be a floating waterlight approved under approval series 161.010 or other standard specified by the Commandant. Vessel waterlight batteries were expired and will be restricted to daytime operations until corrected.
46 CFR 180.175(f)(4)
Action required: 705 - Other - as specified
Resolved 18 October 2022
Resolution: O/O sent documentation of corrected item.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 January 2022
Resolved
The floating waterlight must be attached around the body of the life float by a 3/8" lanyard, resistant to deterioration from ultraviolet light and at least 18' in length. Waterlight lanyard was deteriorated and needs to be replaced.
46 CFR 180.175(f)(4)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 February 2022
Resolved 18 October 2022
Resolution: O/O sent documentation of corrected item.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 January 2022
Resolved
Flexible hose shall be fabricated with an inner tube and a cover of synthetic rubber or other suitable material reinforced with wire braid. Wet exhaust, port and stbd engine fuel hose were found severely chaffed and need replacement.
46 CFR 182.20-40(a)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 February 2022
Resolved 18 October 2022
Resolution: O/O sent documentation of corrected item.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 January 2022
Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 1" high. Marking on remote fuel shutoff has faded. Remark existing lettering.
46 CFR 185.608
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 February 2022
Resolved 18 October 2022
Resolution: O/O sent documentation of corrected item.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 January 2021
Resolved
A bilge suction must be fitted with a suitable strainer having an open area not less than three times the area of the bilge pipe. Bilge suction in engine compartment missing strainer of appropriate size.
46 CFR 182.25-5(b)
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 February 2021
Resolved 16 April 2021
Resolution: Photo evidence provided of adequate strainers installed on bilge suction pickups.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 26 January 2021
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date U.S. Coast Pilot and Coast Guard Light List. Extracts for the areas to be transited may be provided instead of the complete publication. U.S. Coast Pilot and Light List were last updated in 2014.
46 CFR 184.420(a)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 February 2021
Resolved 16 April 2021
Resolution: Coast Pilot and Light Lists updated to 2021.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 January 2021
Resolved
Valves for removing water or impurities from diesel fuel in water traps or strainers are permitted. These valves must be provided with caps or plugs to prevent fuel leakage. Flame shield bowls for port engine, stbd engine, and generator fuel filters are fitted with drain valves without caps or plugs to prevent fuel leakage.
46 CFR 182.458(b)(9)
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 February 2021
Resolved 16 April 2021
Resolution: Caps fitted to drains on flame shield bowls.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 January 2021
Resolved
Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Bonding wires attached to generator drip pan wasted and not serving original purpose.
46CFR183.200(b)
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 February 2021
Resolved 16 April 2021
Resolution: Bonding wires renewed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 January 2020
Resolved
The ring life buoy must be in accordance with 46 CFR 160.050 in subchapter Q. The life buoy grablines were wasted from weather exposure. repair or replace ring life buoy to meet requirements of CFR and provide proof of correction.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 February 2020
Resolved 30 January 2020
Resolution: Owner provided digital photo of newly purchased, properly label and taped ring life buoy.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 22 January 2020
Resolved
Each battery used in an item of lifesaving equipment, except inflatable survival craft equipment, must be replaced during the annual inspection if the expiration date of the battery has passed. The water light battery located on the ring life buoy was expired. Replace with manufacture recommended battery and provide proof of correction.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 February 2020
Resolved 30 January 2020
Resolution: Owner purchased new batteries for all ring life buoy lights onboard vessel.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 22 January 2020
Resolved
A vessel must carry adequate and up-to-date charts to include area of voyage route. Replace outdated charts to meet CFR requirements.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 February 2020
Resolved 30 January 2020
Resolution: Vessel Operator updated onbvoard vessel charts.
04 - Emergency Systems › N/A - No Subsystem › Location of emergency installations
Issued 22 October 2018
Resolved
Provide vessel specific emergency instructions.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 November 2018
Resolved 5 November 2018
Resolution: Cleared outstanding def after receiving appropriate instructions.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 22 October 2018
Resolved
"Sternlight" must be placed nearly as practicable at the stern showing an unbroken light over an arc of 135 degrees. Vessels current configuration partially blocks required arc of visibility.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 December 2018
Resolved 5 November 2018
Resolution: Cleared outstanding def. Received visual proof of vessels sternlight in approved location.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 October 2018
Resolved
Provide calibrated alcohol testing device.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 November 2018
Resolved 5 November 2018
Resolution: Cleared outstanding def. Vessels O/O provided new alcohol test kits.
Construction/Loadline › Penetrations › Valve Flange
Issued 26 July 2016
Resolved
Install through-hull valve at sink drain located at portside aft quarter.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 July 2016
Resolved 17 October 2018
Resolution: Inspected valve. all sat
Construction/Loadline › Penetrations › Valve Flange
Issued 26 July 2016
Resolved
Repair/replace through-hull valve for the head inlet located at the portside aft quarter
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 July 2016
Resolved 17 October 2018
Resolution: Inspected valve. all sat.
Construction/Loadline › Structures › Superstructure
Issued 26 July 2016
Resolved
Remove exterior overhead cover on the port and starboard side for examination
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 July 2016
Resolved 17 October 2018
Resolution: Installation sat.
Construction/Loadline › Structures › Superstructure
Issued 26 July 2016
Resolved
Cut open 01 deck aft ledge for life float for examination and repair
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 July 2016
Resolved 17 October 2018
Resolution: Repair was inspected. all sat.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 26 July 2016
Resolved
Remove/renew electrical outlet/box located in the shower
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 July 2016
Resolved 17 October 2018
Resolution: Junction box remains, however all electrical cables were discontinued. all sat.