MAURY USCG vessel records
← All vessels

GSL TEGEA

GSL TEGEA is a 2001 freight ship. The Coast Guard has recorded 32 inspections since 2016, most recently in December 2025, along with 4 deficiencies and 8 operational controls, 1 with no removal date recorded.

Records from 2016 to 2025. Most recent: inspection, 26 December 2025.

Built
2001
Last inspected
26 December 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
1 with no removal date recorded

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 26 December 2025
…with no type recorded6
Operational controls 1 with no removal date recorded
Years with a record 9 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9222986
Flag
LIBERIA
Maury page id
psix-30595

Documentation record

Tonnage as PSIX records it71621 - Dead Weight, Metric Ton
92730 - Displacement, Metric Ton
66058 - Convention (Subpart B), Gross Ton
35977 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 32

26 December 2025 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8287408
9 May 2025 PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8131558
3 April 2025 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8104854
17 March 2025 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8095153
27 January 2025 In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8069603
21 January 2025 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8067085
6 November 2024 PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8031209
20 August 2024 PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7981817
3 June 2024 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7925887
28 December 2023 PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7841807
24 July 2023 Administrative Inspection · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7750569
15 May 2023 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7688783
9 May 2023 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7684860
5 May 2023 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7681688
4 May 2023 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7680918
4 May 2023 Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7680989
3 May 2023 PSC B · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7677273
12 February 2023 Administrative Inspection · Ballast Water Examination · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7635412
6 October 2022 Administrative Inspection · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7569999
3 October 2022 PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7570373
11 January 2022 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7378507
26 October 2021 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7340253
25 October 2021 PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7339003
4 October 2019 ISPS II Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6828006
28 September 2019 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6823133
6 October 2018 Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6552965
26 September 2018 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6545466
10 October 2017 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6285101
22 July 2017 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6216893
20 May 2017 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6150869
13 May 2017 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6145225
28 July 2016 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5955611

Deficiency record · 4

02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 25 October 2021 Resolved
Steering gear control shall be provided for the main steering gear, both on the navigation bridge and in the steering gear compartment. (74 SOLAS (01) II-1/29.7.1) PSCO observed steering gear pump #2 not operational from the navigation bridge when using non-follow-up.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 25 October 2021
Resolved 25 October 2021
Resolution: Electrician repaired non-follow-up control connection between the bridge and #2 steering pump. Flag and Class were present to confirm satisfactory repair.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 October 2021 Resolved
Paint lockers and flammable liquid lockers shall be protected by an appropriate fire-extinguishing arrangement approved by the administration. (74 SOLAS (01) II-2/18.7) PSCO observed paint cans on the top tier of the paint rack stacked above the sprinkler system.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 25 October 2021
Resolved 25 October 2021
Resolution: Paint cans stacked higher than sprinkler heads were removed and placed lower in the space.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 26 September 2018 Resolved
IN A SHIP IN WHICH OIL FUEL IS USED, THER ARRANGEMENTS FOR THE UTILIZATION OF THE FUEL OIL SHALL BE SUCH AS TO ENSURE THE SAFETY OF THE SHIP AND PERSONS ON BNOARD. BUILT UP OIL AND OILY RAGS WERE OBSERVED UNDERNEATH THE 04 GENERATORS AND MAIN DIESEL ENGINE AS WELL AS BILGE NEAR MDE AND OIL PURIFYIN G ROOM.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 6 October 2018
Resolution: PSC NOLA completed deficiency check, satisfying the requirement.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 26 September 2018 Resolved
STAIRWAYS AND LIFT TRUNKS WHICH PENETRATE MORE THAN A SINGLE DECK SHALL BE SURROUNDED BY AT LEAST "A-0"CLASS DIVISIONS AND BE PROTECTED BY SELF CLOSING DOORS AT ALL LEVELS. THREE CLASS 'A' SELF CLOSING DOORS IN THE MAIN STAIRWAY AND ONE SELF CLOSING DOOR IN THE GALLEY DO NOT FULLY CLOSE. 74SOLAS('01 CONS) II-2/46.1
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 26 September 2018
Resolved 26 September 2018

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.