MAURY USCG vessel records Sign in
← All vessels

DYC

DYC is a 1988 passenger vessel (inspected). The Coast Guard has recorded 54 inspections since 1988, most recently in May 2026, along with 51 deficiencies.

Records from 1988 to 2026. Most recent: inspection, 13 May 2026.

Built
1988
Last inspected
13 May 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

305964
Flag
UNITED STATES
—
Maury page id
psix-305964

Inspections, by type

Years with a record 36 calendar years (1988–2026)
The 54 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it4 - Regulatory (Subpart C or D), Gross Ton
4 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 54

13 May 2026 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8350508
15 April 2026 Drydock Exam · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8330911
13 May 2025 COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8095057
15 May 2024 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7908212
1 April 2024 Hull Examination · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7880986
19 July 2023 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7735878
13 July 2022 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7498676
20 April 2022 Hull Examination · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7413712
28 June 2021 Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7239059
27 May 2020 Hull Examination · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6957103
9 July 2019 Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6742189
7 August 2018 Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6504711
23 April 2018 Deficiency Check · Examination of Repairs · Hull Examination · Simplified Stability Test · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6398391
27 June 2017 Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6189009
11 May 2016 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5874991
29 April 2016 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5867088
3 June 2014 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4878341
6 May 2014 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4851762
19 June 2012 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4347596
13 December 2011 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4206988
13 May 2009 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3474110
24 April 2008 Hull Examination · Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3194762
4 June 2007 Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2951026
25 May 2006 Re-Inspection · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2658459
19 May 2005 COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2362018
14 May 2004 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2067391
3 May 2004 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2058312
24 July 2003 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1855606
11 July 2002 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1644772
21 May 2002 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1618998
11 May 2001 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1450638
25 May 2000 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1464945
10 May 2000 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1408514
26 May 1999 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 802944
27 May 1998 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1126382
1 May 1998 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1124146
2 June 1997 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1109700
20 May 1997 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1099558
11 July 1996 Re-Inspection · Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1087613
9 May 1996 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1083290
30 May 1995 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 873994
19 May 1995 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 929782
30 June 1994 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1140388
24 May 1994 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1171405
27 April 1994 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 858250
20 May 1993 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 831700
19 May 1992 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 946295
27 April 1992 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1270460
14 May 1991 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1228826
4 October 1990 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1242299
20 June 1990 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 917168
25 April 1990 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1041326
5 May 1989 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1035456
6 May 1988 Hull Examination · Initial Certification
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1043216

Deficiency record · 51

01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 28 June 2021 Resolved
Except as provided in §173.17, no person may use a vessel to which this part applies. The vessel state registration was not valid. Prohibited from operating with passengers until proof of state registration.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 July 2021
Resolution: The Operator sent proof of the State Registration.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 28 June 2021 Resolved
The Certificate of Inspection must be posted under glass in a conspicuous place on the vessel. If posting is impractical, the COI must be kept on board and made available on request. The COI was not on site.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Resolved 28 June 2021
Resolution: Sent operator a copy of COI.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 28 June 2021 Resolved
A person may not employ or engage an individual in a position required to hold an MMC unless that individual maintains a current medical certificate. Both vessel operators could not provide a medical certificate.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 July 2021
Resolution: Received email from operator with receipt stating that a new medical certificate was mailed by the REC.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 28 June 2021 Resolved
The master shall conducted sufficient man overboard and fire drills and log date with description. There was no record of training or drills conducted.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 July 2021
Resolution: Received picture from operator of logbook showing training and drills recorded.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 July 2019 Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck. Vessel operator could not access the cover to operate the fuel shutoff valve.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2019
Resolved 22 July 2019
Resolution: Vessel operator added a screwdriver near the fuel shut off cover to assist in access of fuel shut off valve.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 July 2019 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked ‘‘First-Aid Kit’’. A first-aid kit. Expired contents in First Aid Kit
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2019
Resolved 22 July 2019
Resolution: Vessel operator sent in photographs of new first aid kit
Stability › Incline Test › General
Issued 5 June 2018 Resolved
Not to operate in passenger service until stability test conducted.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 June 2018
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 23 April 2018 Resolved
TJT-02 Have working company drug and alcohol program in place IAW 46CFR16 by 02JUL18.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2018
Resolved 6 August 2018
Resolution: Company switched DAPI program to use Maritime Consortium and stated new crew list will all pre-employment background checks and EAP being conducted.
Stability › Intact Stability (when using lifting gear) › General
Issued 23 April 2018 Resolved
TJT-03 Not to carry more than 12 persons and 11 passengers until new stability letter drafted and issued; 46CFR176.306.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2018
Resolved 6 August 2018
Resolution: TEST CONDUCTED STABILITY LETTER ISSUED
Communications › Visual Communication › Signalling Lamp
Issued 23 April 2018 Resolved
TJT-04 Have onboard vessel working oil, water temp, and fuel gauges; 46CFR182.410 by 02JUL18.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2018
Resolved 6 August 2018
Resolution: All gauges for propulsion engine were operational.
Stability › Freeing Ports › General
Issued 23 April 2018 Resolved
TJT-05 Install non-returns on deck drainage scuppers by 02JUL18; 46CFR176.306.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2018
Resolved 6 August 2018
Resolution: . All port and starboard scuppers had non-return covers inplace.
Communications › Alarms/Indicators › High Water Alarm
Issued 27 June 2017 Resolved
High water alarm was not operational. High water alarm is not required so issued 14 day corrective date.
Action required: 705 - Other - as specified
Due 11 July 2017
Resolved 21 July 2017
Resolution: Rcvd email from vsl rep stating high water alarm was operational.
Construction/Loadline › Structures › Deck Plating
Issued 24 April 2008 Resolved
Forward storage compartment; fiberglass covering (non-structural) in bottom of compartment cracked. Cut out and renew.
Action required: 705 - Other - as specified
Resolved 24 June 2008
Resolution: All repairs completed sat.
Construction/Loadline › Structures › Deck Plating
Issued 24 April 2008 Resolved
Renew removable access board on deck, stbd of console due to rot.
Action required: 705 - Other - as specified
Due 24 June 2008
Resolved 24 June 2008
Resolution: Board repaired sat.
Engineering › Sea-water System (primary cooling) › Piping
Issued 24 April 2008 Resolved
Renew non-metallic hose between engine manifold and exhaust elbow due to dry rot.
Action required: 705 - Other - as specified
Due 24 June 2008
Resolved 24 June 2008
Resolution: Metalic hose re-newed sat.
Engineering › Bilge Water Management System › Not Operational
Issued 13 July 2006 Resolved
REPAIR INOPERABLE BILGE PUMP
Due 27 July 2006
Resolved 2 August 2006
Resolution: Pump repaired sat.
Engineering › Fuel Oil Service System › Filter
Issued 25 May 2006 Resolved
Replace missing filter bowl.
Due 27 July 2006
Resolved 2 August 2006
Resolution: Filter bowl provided sat.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 25 May 2006 Resolved
Provide proof of enrollment.
Due 27 July 2006
Resolved 2 August 2006
Resolution: proof of enrollment provided sat.
Navigation › Collision/Grounding Avoidance
Issued 14 May 2004 Resolved
Repair bow navigation light. LEGACY COMPONENT DESC: Navigation Lights
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 May 2004
Resolved 4 June 2004
Resolution: Bow navigation light repaired.
Lifesaving › Lifebuoys
Issued 14 May 2004 Resolved
Stencil vessels name on lifering. LEGACY COMPONENT DESC: Markings (ship name/port)
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 27 May 2004
Resolved 4 June 2004
Resolution: Vessels name stenciled on lifering.
Operations/Management › Drills/Instruction
Issued 14 May 2004 Resolved
Post a lifejacket doning instruction placard on the vessel. LEGACY COMPONENT DESC: Safety Orientation
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 May 2004
Resolved 4 June 2004
Resolution: Lifejacket doning instruction placard installed.
Communications › Radio Communications
Issued 14 May 2004 Resolved
Repair/replace VHF radio antenna. LEGACY COMPONENT DESC: VHF Radiotelephone
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 27 May 2004
Resolved 4 June 2004
Resolution: New VHF antenna installed.
Fire Fighting › Ventilation Systems
Issued 18 July 2003 Resolved
Provide means to secure ventilation for engine compartment. LEGACY COMPONENT DESC: Duct Hatches
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 July 2003
Resolved 18 July 2003
Resolution: Covers purchased and installed by owner.
Lifesaving
Issued 26 May 1999 Resolved
PROVIDE OPERATIONAL FLASHLIGHT.
Condition: Unknown
Due 28 May 1999
Resolved 28 May 1999
Lifesaving
Issued 26 May 1999 Resolved
RE-APPLY RETROREFLECTIVE TAPE TO THREE CHILD PFDS.
Condition: Unknown
Due 28 May 1999
Resolved 28 May 1999
Lifesaving
Issued 26 May 1999 Resolved
REPAIR WATERLIGHT ON RING BUOY AND APPLY RETROREFLECTIVE TAPE.
Condition: Unknown
Due 28 May 1999
Resolved 28 May 1999
Fire Fighting
Issued 26 May 1999 Resolved
INSTALL B-II PORTABLE FIRE EXTINGUISHER FOR A TOTAL OF 2 B-II EXTINGUISHERS.
Condition: Unknown
Due 28 May 1999
Resolved 28 May 1999
Fire Fighting
Issued 26 May 1999 Resolved
COME INTO COMPLIANCE WITH FIXED FIRE FIGHTING REGS IAW 46CFR181.400.
Condition: Unknown
Due 28 May 1999
Resolved 28 May 1999
Navigation
Issued 20 May 1997 Resolved
PROVE PROPER OPERATION OF ANCHOR LIGHT.
Condition: Unknown
Due 9 June 1997
Resolved 9 June 1997
Engineering
Issued 20 May 1997 Resolved
PROVIDE HEAT SHIELD FOR RACOR FUEL FILTER.
Condition: Unknown
Due 9 June 1997
Resolved 9 June 1997
Navigation
Issued 20 May 1997 Resolved
184.506 Post a durable placard next to all radio telephone installations with the emergency broadcast instructions and information specific to the individual vessel. See 184.510.
Condition: Unknown
Due 29 May 1997
Resolved 9 June 1997
Engineering
Issued 20 May 1997 Resolved
MARK REMOTE FUEL SHUT OFF VALVES INCLEARLY LEGIBLE LETTERS AT LEAST 1 INCH HIGH INDICATING THE PURPOSE OF THE VALVE AND DIRECTION OF OPERATION. IAW 46CFR 185.608.
Condition: Unknown
Due 29 May 1997
Resolved 9 June 1997
Lifesaving
Issued 20 May 1997 Resolved
POST EMERGENCY CHECK LIST IAW 46CFR 185.510 AND 185.512.
Condition: Unknown
Due 29 May 1997
Resolved 9 June 1997
Lifesaving
Issued 20 May 1997 Resolved
PROVIDE SPACER AND RENEW BATTERY FOR RING BUOY WATER LIGHT.
Condition: Unknown
Due 9 June 1997
Resolved 9 June 1997
Engineering
Issued 11 July 1996 Resolved
REMOVE DUCT TAPE AND PROPERLY RECONNECT THE PORT AIR SUPPLY DUCT TO THE MDE.
Condition: Unknown
Due 25 July 1996
Resolved 6 August 1996
Navigation
Issued 11 July 1996 Resolved
RESECURE THE LOOSE STERN LIGHT.
Condition: Unknown
Due 25 July 1996
Resolved 6 August 1996
Engineering
Issued 11 July 1996 Resolved
DOUBLE CLAMP THE FLEXIBLE FUEL HOSE FROM FILTER TO ENGINE.
Condition: Unknown
Due 26 July 1996
Resolved 6 August 1996
Documentation
Issued 11 July 1996 Resolved
PROVIDE PROOF OF PAYMENT OF THE ANNUAL USER FEE.
Condition: Unknown
Due 25 July 1996
Resolved 29 July 1996
Documentation
Issued 11 July 1996 Resolved
PRIOR TO CARRYING MORE THAN SIX PASSENGERS, PROVIDE PROOF OF COMPLIANCE WITH THE DRUG TESTING REQUIREMENTS CONTAINED IN 46 CFR PART 16.
Condition: Unknown
Due 25 July 1996
Resolved 6 August 1996
Lifesaving
Issued 11 July 1996 Resolved
PRIOR TO CARRYING MORE THAN SIX PASSENGERS, PROVIDE ONE ADDITIONAL ADULT COAST GUARD APPROVED TYPE I PFD.
Condition: Unknown
Due 25 July 1996
Resolved 6 August 1996
Engineering
Issued 11 July 1996 Resolved
RESTENCIL THE EMERGENCY FUEL SHUTOFF VALVE LOCATION.
Condition: Unknown
Due 25 July 1996
Resolved 6 August 1996
Lifesaving
Issued 11 July 1996 Resolved
PRIOR TO CARRYING MORE THAN SIX PASSENGERS, PROVIDE A COAST GUARD APPROVED RING BUOY WITH RETROREFLECTIVE TAPE, WATERLIGHT, LINE AND WATERLIGHT LANYARD.
Condition: Unknown
Due 25 July 1996
Resolved 6 August 1996
Lifesaving
Issued 19 May 1995 Resolved
IN ACCORDANCE WITH 46 CFR 185.25-1, POST EMERGENCY INSTRUCTTIONS ABOARD THEVESSEL NO LATER THAN 31MAY95.
Condition: Unknown
Due 31 May 1995
Resolved 30 May 1995
Fire Fighting
Issued 19 May 1995 Resolved
RECONNECT THE LOOSE ELECTRICAL LEADS TO THE BELT DRIVEN FIRE/BILGE PUMP ANDPROVE PROPER OPERATION NO LATER THAN 31MAY95.
Condition: Unknown
Due 31 May 1995
Resolved 30 May 1995
Engineering
Issued 19 May 1995 Resolved
REPLACE THE 30X30 FLAME SCREEN MESH ON THE FUEL TANK VENT LINE NO LATER THAN 31MAY95.
Condition: Unknown
Due 31 May 1995
Resolved 30 May 1995
Documentation
Issued 24 May 1994 Resolved
PRIOR TO USE OF VHF-FM RADIO PROVIDE PROOF OF VALID FCC STATION LICENSE OR REMOVE RADIO FROM VESSEL.
Condition: Unknown
Due 24 June 1994
Resolved 30 June 1994
Documentation
Issued 24 May 1994 Resolved
PROVIDE SATISFACTORY EVIDENCE THAT CHEMICAL TESTING REQUIRED BY 46 CFR PART16 IS BEING CONDUCTED OF VESSEL'S CREW.
Condition: Unknown
Due 24 June 1994
Resolved 30 June 1994
Engineering
Issued 24 May 1994 Resolved
INSTALL FLAME SCREEN ON FUEL TANK VENT.
Condition: Unknown
Due 24 June 1994
Resolved 30 June 1994
Construction/Loadline
Issued 20 June 1990 Resolved
PROVE PROPER OPERATION OF ENGINE DRIVEN RESCUE BILGE PUMP.
Condition: Unknown
Due 20 June 1990
Resolved 20 June 1990
Electrical
Issued 20 June 1990 Resolved
FLOATING ELECTRIC WATERLIGHT OOC. TROUBLE SHOOT AMD PROVE PROPER OPERATIONOF RING BOUY WATERLIGHT PRIOR TO NIGHT TIME OPERATION.
Condition: Unknown
Due 20 June 1990
Resolved 20 June 1990
Unknown
Issued 20 June 1990 Resolved
STERNLIGHT AND ANCHOR LITE OOC. TROUBLE SHOOT AND PROVE PROPER OPERATION OF NAVIGATION LITES PRIOR TO NIGHT TIME OPERATION.
Condition: Unknown
Due 20 June 1990
Resolved 20 June 1990

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.