Professional
The full record for this vessel
Behind this panel: 16 inspections, each with its date, unit and type; 12 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 16
13 May 2026
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8350508
15 April 2026
Drydock Exam · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8330911
13 May 2025
COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8095057
15 May 2024
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7908212
1 April 2024
Hull Examination · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7880986
19 July 2023
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7735878
13 July 2022
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7498676
20 April 2022
Hull Examination · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7413712
28 June 2021
Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7239059
27 May 2020
Hull Examination · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6957103
9 July 2019
Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6742189
7 August 2018
Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6504711
23 April 2018
Deficiency Check · Examination of Repairs · Hull Examination · Simplified Stability Test · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6398391
27 June 2017
Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6189009
11 May 2016
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5874991
29 April 2016
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5867088
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 28 June 2021
Resolved
Except as provided in §173.17, no person may use a vessel to which this part applies. The vessel state registration was not valid. Prohibited from operating with passengers until proof of state registration.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 July 2021
Resolution: The Operator sent proof of the State Registration.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 28 June 2021
Resolved
The Certificate of Inspection must be posted under glass in a conspicuous place on the vessel. If posting is impractical, the COI must be kept on board and made available on request. The COI was not on site.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Resolved 28 June 2021
Resolution: Sent operator a copy of COI.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 28 June 2021
Resolved
A person may not employ or engage an individual in a position required to hold an MMC unless that individual maintains a current medical certificate. Both vessel operators could not provide a medical certificate.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 July 2021
Resolution: Received email from operator with receipt stating that a new medical certificate was mailed by the REC.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 28 June 2021
Resolved
The master shall conducted sufficient man overboard and fire drills and log date with description. There was no record of training or drills conducted.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 July 2021
Resolution: Received picture from operator of logbook showing training and drills recorded.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 July 2019
Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck.
Vessel operator could not access the cover to operate the fuel shutoff valve.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2019
Resolved 22 July 2019
Resolution: Vessel operator added a screwdriver near the fuel shut off cover to assist in access of fuel shut off valve.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 July 2019
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked ‘‘First-Aid Kit’’. A first-aid kit.
Expired contents in First Aid Kit
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2019
Resolved 22 July 2019
Resolution: Vessel operator sent in photographs of new first aid kit
Stability › Incline Test › General
Issued 5 June 2018
Resolved
Not to operate in passenger service until stability test conducted.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 June 2018
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 23 April 2018
Resolved
TJT-02 Have working company drug and alcohol program in place IAW 46CFR16 by 02JUL18.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2018
Resolved 6 August 2018
Resolution: Company switched DAPI program to use Maritime Consortium and stated new crew list will all pre-employment background checks and EAP being conducted.
Stability › Intact Stability (when using lifting gear) › General
Issued 23 April 2018
Resolved
TJT-03 Not to carry more than 12 persons and 11 passengers until new stability letter drafted and issued; 46CFR176.306.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2018
Resolved 6 August 2018
Resolution: TEST CONDUCTED STABILITY LETTER ISSUED
Communications › Visual Communication › Signalling Lamp
Issued 23 April 2018
Resolved
TJT-04 Have onboard vessel working oil, water temp, and fuel gauges; 46CFR182.410 by 02JUL18.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2018
Resolved 6 August 2018
Resolution: All gauges for propulsion engine were operational.
Stability › Freeing Ports › General
Issued 23 April 2018
Resolved
TJT-05 Install non-returns on deck drainage scuppers by 02JUL18; 46CFR176.306.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2018
Resolved 6 August 2018
Resolution: . All port and starboard scuppers had non-return covers inplace.
Communications › Alarms/Indicators › High Water Alarm
Issued 27 June 2017
Resolved
High water alarm was not operational. High water alarm is not required so issued 14 day corrective date.
Action required: 705 - Other - as specified
Due 11 July 2017
Resolved 21 July 2017
Resolution: Rcvd email from vsl rep stating high water alarm was operational.