YUKON QUEEN is a 1988 passenger vessel (inspected). The Coast Guard has recorded 13 inspections since 2016, most recently in May 2023, along with 11 deficiencies — 1 with no resolution recorded —, 1 operational control and 3 casualty investigations between 2007 and 2015.
Records from 2007 to 2023. Most recent: operational control imposed, 7 May 2023.
This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
DocumentationValid · issued 12 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it28 - Regulatory (Subpart C or D), Gross Ton 19 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 13
7 May 2023Damage Survey · Administrative Inspection · Deficiency Check
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 May 2023Resolved
The YUKON QUEEN sustained fire damage in the engine room and the reliability of the vessel’s systems presents a risk while operating under its own power. Prior to movement submit a tow plan to this office or cognizant Captain of the Port for review and acknowledgment for each intended transit. Each transit shall be made in accordance with a tow plan that has been reviewed and acknowledged by the cognizant Captain of the Port. This requirement remains in place until the vessel has been deemed safe to transit on its own power by the attending marine inspector.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 9 May 2023
Resolution: Tow plan was received and approved.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 7 May 2023No resolution recorded
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its COI giving consideration to provisions for a seaworthy hull, protection against fire, means of escape in case of a sudden unexpected casualty, guards and rails in hazardous places, ventilation of enclosed spaces, and necessary facilities for passengers and crew. Vessel sustained fire damage, causing unknown damage to the vessel's structure, electrical systems, and machinery. Operator shall determine the extent of the damage and coordinate repairs with the attending Coast Guard Inspector. Vessel is restricted from carrying passengers until a re-inspection of all vessel systems is completed to the satisfaction of the attending Coast Guard marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 10 April 2023Resolved
Each connection to a conductor or terminal part of a conductor must be made within an enclosure. Bilge pump and high water alarm splices were not made within an enclosure. Additionally, the electrical enclosure above the bilge pump is missing the cover.
46 CFR 183.340(g)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 April 2023
Resolution: Bilge high water alarm terminal ends were placed into the enclosure and the cover was replaced.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 April 2023Resolved
Fire extinguishing equipment installed on a vessel in excess of the requirements of §§ 181.400 and 181.500 must be designed, constructed, installed, and maintained in accordance with a recognized industry standard acceptable to the Commandant (CG-ENG-4). Vessel had 01 excess fire extinguisher that had not been serviced annually.
46 CFR 181.120(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 April 2023
Resolution: Fire extinguisher has been serviced.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 10 April 2023Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. Vessels 1st aid kit had expired aspirin.
46 CFR 184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 April 2023
Resolution: Expired items have been replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 April 2023Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. Starboard alternator cover was found cracked and loose.
46 CFR 177.960
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 April 2023
Resolution: Alternator cover has been replaced.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 10 April 2023Resolved
Provision shall be made by means of plugs, covers, etc., to prevent the admission of air into the space protected. The aft engine room natural ventilation opening is not fixed with a closure.
46 CFR 181.20-35 (Old T)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 April 2023
Resolution: Aft E/R natural ventialltion has been fixed with a cover.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 April 2023Resolved
Each floating waterlight must be approved in accordance with § 161.010 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.110. Floating waterlight battery was not replaced annually per manufacturers instructions.
46 CFR 180.70(d)(1)
Action required: 10 - Deficiency Rectified
Resolved 10 April 2023
Resolution: Battery has been replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 April 2022Resolved
The discharge ends of vent pipes shall be fitted with removable flame screens or flame arresters. The flame
screens shall consist of a single screen of corrosion resistant wire of at least 30 x 30 mesh. Installed flame screens are not 30 x 30 mesh.
46 CFR 182.20-35 (OLD T)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2022
Resolved 14 May 2022
Resolution: 30x30 flame screen has been installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 April 2022Resolved
Where liquid level indicating gages are installed, they shall be of heat resistant materials, adequately protected from mechanical damage and provided at the tank connections with devices which will automatically close in the event of rupture of the gage or gage lines. Fuel tank sight glasses do not have devices that will automatically close in the event of a rupture. Valves are to remain closed at all times while vessel is in operation until devices are installed at next DDX.
Action required: 705 - Other - as specified
Resolved 13 March 2023
Resolution: Sight glasses were removed and a threaded plug was installed on both tanks.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 13 June 2019Resolved
A vessel of at least 7.9 meters in length, a visual and audible alarm must be provided at the operating station to indicate high water level in a space with a through hull fitting below the deepest load waterline. No visual alarm for the tank room.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 July 2019
Resolved 10 July 2019
Resolution: Administratively cleared. Rcvd certification fm vsl master that visual alarm for tank rm now operational.
22 May 2007Routine · role: Involved in a Marine Casualty · 1 injured · activity 2944886
21 July 2008Routine · role: Involved in a Marine Casualty · activity 3304925
19 June 2015Routine · role: Involved in a Marine Casualty · activity 5921872
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.