11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 May 2026
Resolved
Replace 02 Adult life jackets. Passenger count is lower to 20 passengers until life jackets are placed on vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 May 2026
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 6 May 2026
Resolved
Get a copy of the captains FCC operators license.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 May 2026
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 6 May 2026
Resolved
AFT high water alarm broken no light only audible alarm.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 May 2026
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 September 2025
Resolved
Proper brackets for 02 portable fire extinguishers need to be replaced with proper size brackets. Operation station and machinery area.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 September 2025
Resolved 19 September 2025
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 8 September 2025
Resolved
Captain needs to have a FCC operators license.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 September 2025
Resolved 19 September 2025
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 12 June 2024
Resolved
Engine failed to shut down when simulating discharge of fireboy system. Must conduct repairs and test to the satisfaction of attending CG Marine Inspector prior to carrying passengers.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 June 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 November 2023
Resolved
Life float had a big/deep hole in it with some of the flotation missing. Must replace life float.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2023
Resolved 21 December 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 November 2023
Resolved
Adult and child life jackets must be stowed separated from each other and labeled with Qty of each.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2023
Resolved 21 November 2023
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 8 November 2023
Resolved
First aid kit was missing aspirin. Replace missing aspirin so that you have a total of at least 100 tablets.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2023
Resolved 21 November 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 November 2023
Resolved
Fuel supply and return hoses do not meet the SAE J1942 standard and fittings do not meet the J1475 Standard. Must replace both hoses and fittings to meet the required standard.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2023
Resolved 21 December 2023
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 8 August 2022
Resolved
Company could not show verification that Company and all crew are currently enrolled in Consortium and meeting the Chemical testing program requirement. Must be able to provide proof of enrollment and preemployment drug test with negative results prior to carrying passengers on any of the companies vessels.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 August 2022
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 8 August 2022
Resolved
Floating water light for life float does not work, vessel restricted to daylight hours only until cleared.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 September 2022
Resolved 11 August 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 August 2022
Resolved
Steering fluid leak at the helm pump. Must repair and test to the satisfaction of attending CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 September 2022
Resolved 26 October 2022
Resolution: Installed new helm pump
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 August 2022
Resolved
Vessels hatch is in the way of connecting the tiller for emergency steering and un able to connect. Make repairs and test to the satisfaction of attending CG Marine Inspector.
Plan is to contact Sea Tow if loss of steering.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 September 2022
Resolved 26 October 2022
Resolution: New tiller fabricated, test SAT
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 8 August 2022
Resolved
EPIRB battery expired 2019, operational test was SAT, must replace battery on EPRIB.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 September 2022
Resolved 11 August 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 8 August 2022
Resolved
No alarms for low oil pressure and high jacket water temperature. Make repairs and test tot he satisfaction of attending CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 August 2022
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 8 August 2022
Resolved
Both life float paddles are dry rotted and breaking apart. Must replace both paddles that meet requirements and label with vessels name.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 September 2022
Resolved 11 August 2022
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 8 August 2022
Resolved
Life float needs to be labeled with vessel new name.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 September 2022
Resolved 11 August 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 August 2022
Resolved
All life jackets needs to be labeled with vessel new name.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 September 2022
Resolved 11 August 2022
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 8 August 2022
Resolved
Vessel name is missing on each side of the bow. Vessel will have name added on a wrap at drydock in NOV 2022.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 November 2022
Resolved 26 October 2022
Resolution: New wrap installed on each side of the vessel with name
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 8 August 2022
Resolved
Vessel name and hailing port must be on the stern. Vessel will have name added on a wrap at drydock in NOV 2022.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 November 2022
Resolved 26 October 2022
Resolution: vessels name and hailing port added to stern
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 August 2022
Resolved
Must label all bilge high water alarms and bilge pumps.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 September 2022
Resolved 11 August 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 8 August 2022
Resolved
Throttle controls speed of engine and transmission are worn and wont stay in place without bungee cords. Make repairs and test to the satisfaction of CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 September 2022
Resolved 26 October 2022
Resolution: New throttles were installed. Test SAT
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 May 2021
Resolved
24 inch life ring buoy has damage and needs replacing. Must replace 24 inch life ring buoy and label with vessel's name.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 June 2021
Resolved 14 June 2021
Resolution: Bought a new 24 inch life ring and labeled with vessel's name.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 10 May 2021
Resolved
Both Captains do not have FCC operators permit. Must have FCC operators permit if operating more than 6 passengers.
47 CFR 80.159(e)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 June 2021
Resolved 17 June 2021
Resolution: Received email with Captains FCC operator's permit
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 10 May 2021
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 June 2021
Resolved 16 June 2021
Resolution: Received picture of new Medical certifacation.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 May 2021
Resolved
2 child life jackets need retro tape replaced. Must replace retro tape on both life jackets.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 June 2021
Resolved 14 June 2021
Resolution: Replaced all retro on both life jackets.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 10 May 2021
Resolved
First aid kit was missing couple items and also had expired items. Must repace all missing and expired items to meet requirements.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 June 2021
Resolved 16 June 2021
Resolution: All expired or missing items were replaced.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 10 May 2021
Resolved
Vessel did not have any CG approve NAV Charts onboard and GPS was not updated with latest software to meet requirements in NVIC 01-16. Must replace missing paper CG approved NAV Chart or update GPS
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 June 2021
Resolved 11 May 2021
Resolution: Updated GPS with latest software.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 10 May 2021
Resolved
Life float has DOT retro tape. Retro tape must be SOLAS. Replace all retro tape with CG approved SOLAS tape.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 June 2021
Resolved 14 June 2021
Resolution: Replaced all retro tape with SOLAS
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 10 May 2021
Resolved
Life float net frame is broken. Must repair frame to meet standards.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 June 2021
Resolved 14 June 2021
Resolution: welded frame back together.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 16 November 2020
Resolved
The transom area around the outboard supports for the swim platform are weak and flexible due to no stiffener support. Add stiffener inside the transom in order to support the swim platform support.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 16 December 2020
Resolved 19 January 2021
Resolution: Cut hole in deck, added new stiffeners on each side and then tabbed in place.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 1 November 2018
Resolved
Vessel must post sign indicating that vessel documents are available upon request since the vessel does not have adequate space within cabin that is protected to post documents.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 February 2019
Resolved 5 February 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 November 2018
Resolved
Vessel had several deteriorated lifevests. Passenger count reduced to 15 adults and 02 children until the full compliment of life vests on the COI is provided.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 February 2019
Resolved 5 February 2019
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 1 November 2018
Resolved
Vessel's life float was condemned and removed from the vessel. Vessel route restricted to within three miles until the lifefloat is replaced and/or vessel requests 3 mile route to be permanently in place.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 February 2019
Resolved 5 February 2019
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 1 November 2018
Resolved
VHF radio not programmed with GPS
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 February 2019
Resolved 5 February 2019
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 1 November 2018
Resolved
Vessel did not have up to date Coast Pilot, Tide/Current Tables, and Light list
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 February 2019
Resolved 5 February 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 1 November 2018
Resolved
Visual indicator for the high water alarms is not activating.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 February 2019
Resolved 5 February 2019
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 1 November 2018
Resolved
Emergency instructions do not reflect vessel operations.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 February 2019
Resolved 5 February 2019
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 1 November 2018
Resolved
Vessel's ventilation shutdown was inoperable due to improper installation of a bracket for the intake hose.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 31 January 2019
Resolved 31 January 2019
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 15 June 2017
Resolved
All PFDs need new reflective material.
Action required: 705 - Other - as specified
Due 29 June 2017
Resolved 29 June 2017
Resolution: All PFDs were renewed.
Lifesaving › Lifebuoys › Serviceable
Issued 15 June 2017
Resolved
Life ring reflective material is wasted and must be replaced.
Action required: 705 - Other - as specified
Due 29 June 2017
Resolved 29 June 2017
Resolution: Reflective material was replaced.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 15 June 2017
Resolved
strobe lanyard does not have a detachable clip. Install new clip.
Action required: 705 - Other - as specified
Due 29 June 2017
Resolved 29 June 2017
Resolution: New clip was installed.
Navigation › Piloting/Steering › Magnetic Compass
Issued 15 June 2017
Resolved
Compass light is extinguished. Replace/renew.
Action required: 705 - Other - as specified
Due 29 June 2017
Resolved 29 June 2017
Resolution: Entire compass was renewed, and tested all sat.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 15 June 2017
Resolved
Epirb testing and Lifecraft maintenance is not being logged. provide new log and maintain.
Action required: 705 - Other - as specified
Due 29 June 2017
Resolved 29 June 2017
Resolution: New logs were provided and new inspections have been logged.