MAURY USCG vessel records Sign in
← All vessels

RIVER QUEEN

RIVER QUEEN is a 1988 passenger vessel (inspected). The Coast Guard has recorded 61 inspections since 1988, most recently in October 2025, along with 26 deficiencies — 1 with no resolution recorded —.

Records from 1988 to 2025. Most recent: inspection, 28 October 2025.

Built
1988
Last inspected
28 October 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WTA2197
306819
Flag
UNITED STATES
367344120
Maury page id
psix-306819

Inspections, by type

…with no type recorded1
Years with a record 36 calendar years (1988–2025)
The 61 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)64.9 ft × 27.2 ft × 6.0 ft
Registered tonnagegross 70 / net 56
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderEAST BAY BOAT WORKS INC · HARKERS ISLAND, NC, UNITED STATES · built 1988
Hull materialWood
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portBRIELLE, NJ
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 22 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it70 - Simplified, Gross Ton
56 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WTA2197MMSI 367344120 · active · compulsorily equipped · granted 6 April 2018, expires 2 June 2028
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 61

28 October 2025 Drydock Exam · Administrative Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8259540
22 April 2025 Internal Structural Exam · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8116470
17 April 2024 Annual Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7897012
2 November 2023 Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7819106
10 May 2023 In-Service Inspection · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7691486
6 May 2022 Deficiency Check · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7445527
14 April 2022 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7439171
2 November 2021 Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7343361
22 April 2021 COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7174066
5 November 2020 Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7090423
20 July 2020 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7011461
26 June 2019 DAPI Audit · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6727260
31 October 2018 Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6568059
29 May 2018 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6420243
1 May 2017 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6110513
2 November 2016 In-Service Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6033477
23 August 2016 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5981285
20 April 2016 Administrative Inspection · DAPI Audit · Deficiency Check · COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5858849
9 May 2014 DAPI Audit · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4865377
22 May 2012 Simplified Stability Test
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4317331
7 May 2012 DAPI Audit · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4302377
1 December 2011 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4199255
2 November 2010 Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3883462
13 April 2009 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3451981
29 April 2008 Annual Inspection · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3192063
23 March 2007 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2892137
5 April 2006 Administrative Inspection · COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2616139
20 January 2006 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2576753
5 April 2005 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2324709
2 November 2004 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2234832
6 April 2004 Periodic Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2039382
3 April 2003 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1767133
29 October 2002 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1697070
23 April 2002 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1608111
3 April 2001 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1066435
12 April 2000 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1048957
13 April 1999 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1124450
20 October 1998 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 804183
14 April 1998 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 789210
6 March 1997 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1097561
1 October 1996 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1145093
10 July 1996 Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1086795
10 April 1996 Re-Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1079549
31 March 1995 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1090096
31 March 1995 COI Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1152162
5 October 1994 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1171113
15 April 1994 MARPOL Annex V Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1168818
20 April 1993 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1147381
8 April 1993 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 833136
29 October 1992 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 963001
13 October 1992 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1246738
9 April 1992 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1268075
9 October 1991 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1245159
11 April 1991 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 912042
3 October 1990 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 919150
11 April 1990 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1213956
21 November 1989 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 918390
5 June 1989 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1341833
17 November 1988 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 892825
22 June 1988 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1205652
9 June 1988 Hull Examination · Initial Construction-Excluding Oversight · Plan Review "T" Boat · Initial Certification
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 892338

Deficiency record · 26

02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 5 January 2026 No resolution recorded
Port and starboard aft corner posts supporting paddle wheel structure show signs of structural distress. Both posts are being pulled aft by the weight of the paddle wheel structure on stays. Submit repair proposal and make repairs to the satisfaction of [name withheld] original due date of November 28, 2025 is past due. Vessel is required to submit a repair proposal to address the corner posts prior to the carriage of passengers. 46 CFR 176.610(b) 701 C
Action required: 705 - Other - as specified
Due 30 November 2026
Resolution: Vessel to make temp repairs consisting of thru-bolts and plates. Structural analysis and/or permanent repairs due at fastener pulling
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 17 April 2024 Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with § 80.59 once every five years. The FCC-licensed technician must use the latest FCC Information Bulletin, How to Conduct an Inspection of a Small Passenger Vessel. If the ship passes the inspection, the technician will issue a Communications Act Safety Radiotelephony Certificate. Vessel's Radiotelephony Certificate expired June 2023. Conduct required inspection and provide valid Radiotelephony Certificate onboard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2024
Resolved 23 April 2024
Resolution: Received renewed Radio Telephony Certificate.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 April 2022 Resolved
Secure dead in wires/splices behind the operating station. 46 CFR 183.200(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2022
Resolved 6 May 2022
Resolution: Received satisfactory photographs of repair.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 April 2022 Resolved
Replace line attached to ring lifebuoy to attached floating light with line at least 3 feet in length and attach around body of lifebuoy. 46 CFR 180.70(d)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2022
Resolved 6 May 2022
Resolution: Received satisfactory photographs of repair.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 22 April 2021 Resolved
The Vessels current COI expired 20APR2021. Vessel must submit an application for re-inspection to the OCMI at least 30 days prior to the expiration date of the Certificate of Inspection. Vessel must receive USCG 5 year inspection prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 April 2021
Resolved 22 April 2021
Resolution: Contducted satisfactory inspection.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 April 2021 Resolved
Engine room, starboard side, one foot above the chine, hull planking is separated. Provide written repair plans to address and repair affected area. Old "T" 46 CFR 176.25-50
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2021
Resolved 2 November 2021
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 22 April 2021 Resolved
VHF radio in pilothouse does not have it's own dedicated circuit. Provide VHF radio with it's own circuit. Provide photos of breaker dedicated to VHF. Old "T" 46 CFR 183.10-20(m)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2021
Resolved 2 November 2021
Resolution: VHF radio has its own dedicated circuit that is battery powered, sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 April 2021 Resolved
Top deck, near pilothouse, dead end cable for equipment that has been replaced, needs to be removed. Remove cable. Old "T" 46 CFR 183.01-1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2021
Resolved 2 November 2021
Resolution: Dead end cable was removed, sat.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 22 April 2021 Resolved
Main fuel shutoff valve connected to reach rod is leaking. Tighten connections to eliminate leak. Old "T" 46 CFR 182.20-40(b)(3)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2021
Resolved 2 November 2021
Resolution: Bonnet valve was tighten, main fuel shutoff valve sat.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 22 April 2021 Resolved
Radio operators permit not on board. Provide photo of Operators Permit. Restricted to 1000 feet from shore. 46 CFR 184.502
Action required: 705 - Other - as specified
Resolved 2 November 2021
Resolution: Radio operator permit was onboard for inspections, sat.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 22 April 2021 Resolved
Engine room, under battery box on starboard side; wood has wasted due to contact with battery acid. Crop and renew rotted wood prior to next credit drydock. Old "T" 46 CFR 176.25-50
Action required: 705 - Other - as specified
Resolved 11 January 2022
Resolution: Repairs made.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 22 April 2021 Resolved
Engine room has 2x4 support that is not properly secured. Secure support, provide photos prior to next credit drydock. Old "T" 46 CFR 176.25-50
Action required: 705 - Other - as specified
Resolved 2 November 2021
Resolution: Support brace in engine room overhead access over port side engine was replaced, sat.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 5 November 2020 Resolved
Ensure the threee fixed CO2 system bottles are properly stowed in accordance with manufacturer's instructions for installations not in a vertical position. 46CFR181.410(c)(7)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 November 2020
Resolution: Attended vessel and witnessed CO2 cylinders properly stowed. Owner had the servicing company confirm stowage and found it was in fact incorrectly installed.
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 5 November 2020 Resolved
Install placard at entrance to engine room stating that the area is protected by a CO2 extinguishing system. 46CFR185.612(g)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2020
Resolved 23 November 2020
Resolution: Proper placarding was installed at entrace to engine room and CO2 bottle storage space.
Communications › Radio Communications › VHF Radiotelephone
Issued 20 April 2016 Resolved
Prove proper operation of DSC radio
Action required: 705 - Other - as specified
Due 20 May 2016
Resolved 5 May 2016
Resolution: Installed new radios
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 20 April 2016 Resolved
Replace mast head light and lens. May not operate in low light and/or night time operations.
Action required: 705 - Other - as specified
Due 20 May 2016
Resolved 5 May 2016
Resolution: Installed new lights
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 20 April 2016 Resolved
Provide drug awarness training with crew and document.
Action required: 705 - Other - as specified
Due 20 May 2016
Resolved 5 May 2016
Resolution: Training provided and documented
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 20 April 2016 Resolved
Crew member [name withheld] is out of DAPI compliance and not currently enrolled, he may not act as a crew member.
Action required: 705 - Other - as specified
Due 20 May 2016
Resolved 5 May 2016
Resolution: Member completed drug testing and is on compant compliance list.
Stability › Intact Righting Energy › General
Issued 1 December 2011 Resolved
Based on the new AAWPP your vessel has been restricted to the following passenger count of 129 Passengers and 4 crew.
Action required: 705 - Other - as specified
Resolved 28 February 2013
Resolution: Vessel took stability reduction.
Documentation › Markings/Placards › Garbage Placard
Issued 13 April 2009 Resolved
MARPOL V placard is not posted onboard vessel.
Due 21 April 2009
Resolved 21 April 2009
Resolution: MARPOL V placard posted onboard.
Documentation › Certificates/Documents › FCC SSL
Issued 13 April 2009 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Due 28 April 2009
Resolved 21 April 2009
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Electrical › Lighting (service) › Switch
Issued 13 April 2009 Resolved
A Light Switch cover and electrical box cover in #2 compartment were found broken. Vessel owner is required to replace them.
Condition: Unknown
Due 28 April 2009
Resolved 21 April 2009
Resolution: Both light switch cover & electrical box cover replaced w/ new.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 3 April 2006 Resolved
COI Expired, issued 835 for vessel not to carry passengers for hire until a satisfactory COI exam has been completed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 April 2006
Resolution: COI completed.
Construction/Loadline
Issued 14 April 1998 Resolved
PRIOR TO OPERATING WITH PASSANGERS MAKE PERMINANT REPAIRS TO THE LEAK IN THE ENGINE ROOM, STARBOARD SIDE, IN WAY OF FRAME 6 FORWARD OF THE AFT BULKHEAD NEXT TO THE KEEL COOLER HULL PENATRATION.
Condition: Unknown
Due 30 April 1998
Resolved 30 April 1998
Engineering
Issued 8 April 1993 Resolved
PROVIDE GUARD FOR BELT DRIVEN FIRE PUMP. TO BE COMPLETED TO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR, NO LATER THAN 22 APR 93.
Condition: Unknown
Due 3 May 1993
Resolved 3 May 1993
Accommodation/Occupational Safety
Issued 17 November 1988 Resolved
REMOVE 2 INCH VALVE FOR NISD DISCHARGE UNDERWATER OR MAKE THE OPERATOR OF THE VALVE A TWO STEP OPERATOR THAT PROHIBITS EASY USE OF THIS VALVE.
Condition: Unknown
Due 17 November 1988
Resolved 17 November 1988