MAURY USCG vessel records
← All vessels

RIVER QUEEN

RIVER QUEEN is a 1988 passenger vessel (inspected). The Coast Guard has recorded 18 inspections since 2016, most recently in October 2025, along with 18 deficiencies — 1 with no resolution recorded —.

Records from 2016 to 2025. Most recent: inspection, 28 October 2025.

Built
1988
Last inspected
28 October 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 28 October 2025
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WTA2197
306819
Flag
UNITED STATES
Maury page id
psix-306819

Documentation record

Registered dimensions (L × B × D)64.9 ft × 27.2 ft × 6.0 ft
Registered tonnagegross 70 / net 56
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderEAST BAY BOAT WORKS INC · HARKERS ISLAND, NC, UNITED STATES · built 1988
Hull materialWood
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portBRIELLE, NJ
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 22 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it70 - Simplified, Gross Ton
56 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 18

28 October 2025 Drydock Exam · Administrative Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8259540
22 April 2025 Internal Structural Exam · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8116470
17 April 2024 Annual Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7897012
2 November 2023 Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7819106
10 May 2023 In-Service Inspection · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7691486
6 May 2022 Deficiency Check · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7445527
14 April 2022 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7439171
2 November 2021 Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7343361
22 April 2021 COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7174066
5 November 2020 Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7090423
20 July 2020 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7011461
26 June 2019 DAPI Audit · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6727260
31 October 2018 Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6568059
29 May 2018 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6420243
1 May 2017 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6110513
2 November 2016 In-Service Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6033477
23 August 2016 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5981285
20 April 2016 Administrative Inspection · DAPI Audit · Deficiency Check · COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5858849

Deficiency record · 18

02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 5 January 2026 No resolution recorded
Port and starboard aft corner posts supporting paddle wheel structure show signs of structural distress. Both posts are being pulled aft by the weight of the paddle wheel structure on stays. Submit repair proposal and make repairs to the satisfaction of [name withheld] original due date of November 28, 2025 is past due. Vessel is required to submit a repair proposal to address the corner posts prior to the carriage of passengers. 46 CFR 176.610(b) 701 C
Action required: 705 - Other - as specified
Due 30 November 2026
Resolution: Vessel to make temp repairs consisting of thru-bolts and plates. Structural analysis and/or permanent repairs due at fastener pulling
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 17 April 2024 Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with § 80.59 once every five years. The FCC-licensed technician must use the latest FCC Information Bulletin, How to Conduct an Inspection of a Small Passenger Vessel. If the ship passes the inspection, the technician will issue a Communications Act Safety Radiotelephony Certificate. Vessel's Radiotelephony Certificate expired June 2023. Conduct required inspection and provide valid Radiotelephony Certificate onboard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2024
Resolved 23 April 2024
Resolution: Received renewed Radio Telephony Certificate.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 April 2022 Resolved
Secure dead in wires/splices behind the operating station. 46 CFR 183.200(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2022
Resolved 6 May 2022
Resolution: Received satisfactory photographs of repair.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 April 2022 Resolved
Replace line attached to ring lifebuoy to attached floating light with line at least 3 feet in length and attach around body of lifebuoy. 46 CFR 180.70(d)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2022
Resolved 6 May 2022
Resolution: Received satisfactory photographs of repair.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 22 April 2021 Resolved
The Vessels current COI expired 20APR2021. Vessel must submit an application for re-inspection to the OCMI at least 30 days prior to the expiration date of the Certificate of Inspection. Vessel must receive USCG 5 year inspection prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 April 2021
Resolved 22 April 2021
Resolution: Contducted satisfactory inspection.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 April 2021 Resolved
Engine room, starboard side, one foot above the chine, hull planking is separated. Provide written repair plans to address and repair affected area. Old "T" 46 CFR 176.25-50
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2021
Resolved 2 November 2021
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 22 April 2021 Resolved
VHF radio in pilothouse does not have it's own dedicated circuit. Provide VHF radio with it's own circuit. Provide photos of breaker dedicated to VHF. Old "T" 46 CFR 183.10-20(m)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2021
Resolved 2 November 2021
Resolution: VHF radio has its own dedicated circuit that is battery powered, sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 April 2021 Resolved
Top deck, near pilothouse, dead end cable for equipment that has been replaced, needs to be removed. Remove cable. Old "T" 46 CFR 183.01-1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2021
Resolved 2 November 2021
Resolution: Dead end cable was removed, sat.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 22 April 2021 Resolved
Main fuel shutoff valve connected to reach rod is leaking. Tighten connections to eliminate leak. Old "T" 46 CFR 182.20-40(b)(3)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2021
Resolved 2 November 2021
Resolution: Bonnet valve was tighten, main fuel shutoff valve sat.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 22 April 2021 Resolved
Radio operators permit not on board. Provide photo of Operators Permit. Restricted to 1000 feet from shore. 46 CFR 184.502
Action required: 705 - Other - as specified
Resolved 2 November 2021
Resolution: Radio operator permit was onboard for inspections, sat.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 22 April 2021 Resolved
Engine room, under battery box on starboard side; wood has wasted due to contact with battery acid. Crop and renew rotted wood prior to next credit drydock. Old "T" 46 CFR 176.25-50
Action required: 705 - Other - as specified
Resolved 11 January 2022
Resolution: Repairs made.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 22 April 2021 Resolved
Engine room has 2x4 support that is not properly secured. Secure support, provide photos prior to next credit drydock. Old "T" 46 CFR 176.25-50
Action required: 705 - Other - as specified
Resolved 2 November 2021
Resolution: Support brace in engine room overhead access over port side engine was replaced, sat.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 5 November 2020 Resolved
Ensure the threee fixed CO2 system bottles are properly stowed in accordance with manufacturer's instructions for installations not in a vertical position. 46CFR181.410(c)(7)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 November 2020
Resolution: Attended vessel and witnessed CO2 cylinders properly stowed. Owner had the servicing company confirm stowage and found it was in fact incorrectly installed.
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 5 November 2020 Resolved
Install placard at entrance to engine room stating that the area is protected by a CO2 extinguishing system. 46CFR185.612(g)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2020
Resolved 23 November 2020
Resolution: Proper placarding was installed at entrace to engine room and CO2 bottle storage space.
Communications › Radio Communications › VHF Radiotelephone
Issued 20 April 2016 Resolved
Prove proper operation of DSC radio
Action required: 705 - Other - as specified
Due 20 May 2016
Resolved 5 May 2016
Resolution: Installed new radios
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 20 April 2016 Resolved
Replace mast head light and lens. May not operate in low light and/or night time operations.
Action required: 705 - Other - as specified
Due 20 May 2016
Resolved 5 May 2016
Resolution: Installed new lights
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 20 April 2016 Resolved
Provide drug awarness training with crew and document.
Action required: 705 - Other - as specified
Due 20 May 2016
Resolved 5 May 2016
Resolution: Training provided and documented
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 20 April 2016 Resolved
Crew member [name withheld] is out of DAPI compliance and not currently enrolled, he may not act as a crew member.
Action required: 705 - Other - as specified
Due 20 May 2016
Resolved 5 May 2016
Resolution: Member completed drug testing and is on compant compliance list.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.