Records from 2016 to 2025. Most recent: inspection, 26 August 2025.
Inspection history · 38
26 August 2025
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8218189
27 June 2025
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8168659
6 March 2025
PSC A
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8089160
10 January 2025
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8060716
29 November 2024
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8041221
29 October 2024
PSC A
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8026270
25 July 2024
PSC A
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7966645
18 July 2024
Administrative Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7961335
3 June 2024
PSC A
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7925120
2 June 2024
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7925023
2 June 2024
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7925439
27 May 2024
Administrative Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7920925
24 May 2024
Appeal
Administrative · Commandant (CG-CVC) · Activity 7949744
3 April 2024
Deficiency Check · PSC A · ISM Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7888356
7 October 2023
PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7804799
18 August 2023
In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7768909
15 August 2023
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7769132
15 August 2023
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7769207
9 October 2022
PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7571119
9 February 2022
PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7392680
18 March 2019
Deficiency Check · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6644666
13 March 2019
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6641614
13 March 2019
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6641625
13 March 2019
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6643247
28 January 2019
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6615801
1 December 2018
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6590315
24 January 2018
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6342626
28 November 2017
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6313760
6 October 2017
PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6282914
9 August 2017
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6235530
13 June 2017
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6174362
18 April 2017
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6127802
26 February 2017
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6094877
25 February 2017
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6094511
2 November 2016
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6036992
17 May 2016
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5879647
26 March 2016
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5839971
27 January 2016
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5803384
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 March 2025
Resolved
All electrical apparatus shall be constructed and so installed as not to cause injury when handled or touched in the normal manner.
PSCO observed 3 lube oil serparaator buttons missing.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 3 May 2025
Resolution: Recieved satisfactory class survey
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 March 2025
Resolved
All electrical apparatus shall be constructed and so installed as not to cause injury when handled or touched in the normal manner.
PSCO observed electrical box for lighting exposed, number one generator junction box open, and in the steering gear room one junction box plug was not properly blanked.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 March 2025
Resolution: RESOLVED ON BOAT
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 6 March 2025
Resolved
The cindition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board.
PSCO observed oil accumilation at lube oil cooler.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 March 2025
Resolution: RESOLVED ON BOAT
08 - Alarms › N/A - No Subsystem › Engineers' alarm
Issued 6 March 2025
Resolved
An engineers' alarm shall be provided to be operated from the engine control room or at the manoeuvring platform as appropriate, and shall be clearly audible in the engineers' accomodation.
PSCO oberved that the audible alarm was turned off.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 March 2025
Resolution: RESOLVED ON BOAT
02 - Structural Conditions › N/A - No Subsystem › Wheelhouse -door -window
Issued 29 October 2024
Resolved
ALL ACCESS OPENINGS IN BULKHEADS AT ENDS OF ENCLOSED SUPERSTRUCTURES SHALL BE FITTED WITH DOORS OF STEEL OR OTHER EQUIVALENT MATERIAL, PERMANENTLY AND STRONGLY ATTACHED TO THE BULKHEAD, AND FRAMED, STIFFENED AND FITTED SO THAT THE WHOLE STRUCTURE IS OF EQUIVALENT STRENGTH TO THE UNPIERCED BULKHEAD AND WEATHERTIGHT WHEN CLOSED. THE MEANS FOR SECURING THESE DOORS WEATHERTIGHT SHALL CONSIST OF GASKETS AND CLAMPING DEVICES OR OTHER EQUIVALENT MEANS AND SHALL BE PERMANENTLY ATTACHED TO THE BULKHEAD OR TO THE DOORS THEMSELVES, AND THE DOORS SHALL BE SO ARRANGED THAT THEY CAN BE OPERATED FROM BOTH SIDES OF THE BULKHEAD.
PSCO OBSERVED LIGHT BETWEEN GASKET AND BRIDGE WING SLIDING DOORS.
ICLL Reg 12(1)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 29 November 2024
Resolution: Vessel submitted documentation of completed door overhaul and repairs.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 25 July 2024
Resolved
EVERY SHIP OF 100GT AND ABOVE SHALL CARRY A GARBAGE MANAGEMENT PLAN WHCIH THE CREW SHALL FOLLOW.
PSCO OBSERVED A SIGNIFICANT AMOUNT OF GARBAGE ONBOARD NOT PROPERLY LABELED OR SEGREGATED IN ACCORDANCE WITH THE SHIPS GARBAGE MANAGEMENT PLAN.
MARPOL (V) 10.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 July 2024
08 - Alarms › N/A - No Subsystem › Closing water-tight doors alarm
Issued 25 July 2024
Resolved
INDICATORS SHALL BE PROVIDED FOR ALL SLIDING DOORS AND FOR HINGED DOORS IN WATERTIGHT BULKHEADS INDICATION SHOWING WHETHER THE DOORS ARE OPEN OR CLOSED SHALL BE GIVEN ON THE NAVIGATION BRIDGE.
PSCO OBSERVED BURNT LIGHTBULBS ON WATERTIGHT BULKHEAD INDICATOR PANEL FOR BOTH OPEN AND CLOSED POSITIONS ON BRIDGE.
74SOLAS(01) II-1/23-1.2
Action required: 10 - Deficiency Rectified
Resolved 30 July 2024
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 25 July 2024
Resolved
THE ARRANGEMENTS FOR THE STOWAGE, DISTRIBUTION, AND UTILIZATION OF OTHER FLAMMABLE OILS EMPLOYED UNDER PRESSURE... SHALL BE SUCH AS TO ENSURE THE SAFETY OF THE SHIP AND PERSONS ON BOARD.
PSCO OBSERVED WET FUEL OIL ON F.O. PURIFIER #3, FRONT OF A/E #2, AND ACTIVE FUEL LEAKS ON THE F.O. INJECTORS ON A/E #2
74SOLAS(01)II-1/15.4
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 July 2024
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 25 July 2024
Resolved
ALL LIFE-SAVING APPLIANCES AND ARRANGEMENTS SHALL COMPLY WITH THE APPLICABLE REQUIREMENTS OF THE CODE.
AS FAR AS PRACTICABLE WATERTIGHT, EXCEPT FOR DRAIN HOLES IN THE CONTAINER BOTTOM
LSA CODE IV/ 4.2.6.1.3
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 July 2024
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 25 July 2024
Resolved
IN MEETING THESE REQUIREMENTS, THE COMPANY SHOULD ENSURE THAT INSPECTIONS ARE HELD AT APPROPRIATE INTERVALS; ANY NON CONFORMITY IS REPORTED, WITH ITS POSSIBLE CAUSE, IF KNOWN; APPROPRIATE CORRECTIVE ACTION IS TAKEN AND RECORDS OF THESE ACTIVITES ARE MAINTAINED. THE COMPANY SHOULD ESTABLISH PROCEDURES TO ENSURE THAT THE SHIP IS MAINTAINED IN CONFORMITY WITH THE PROVISIONS OF THE RELEVANT RULES AND REGULATIONS AND WITH ANY ADDITIONAL REQUIREMENTS WHICH MAY BE ESTABLISHED BY THE COMPANY.
PSCO OBSERVED CREW NOT FOLLOWING LOCK OUT/TAG OUT PROCEDURES OR MAINTAINING LOG. ADDITIONALLY, PSCO OBSERVED CREWMEMBER WORKING ALOFT WHILE INSERTING FPD FOR LIFEBOAT, APPROXIMATELY 5-6 METERS ABOVE DECK, WITHOUT A HARNESS PER SMS PROCEDURES. FINALLY, PSCO OBSERVED CREW NOT PERFORMING ROUTINE MAINTENENCE AS EVIDENCED BY OIL LEAKS/CONDITION OF ENGINE ROOM AND CONDITION OF LIFERAFTS. INTERNAL ISM AUDIT REQUIRED 90 DAYS.
74SOLAS(20) IX/3.1
ISM CODE 10.1
Due 25 October 2024
Resolved 20 October 2024
12 - Dangerous Goods › N/A - No Subsystem › Dangerous goods / harmful substances in pack. form
Issued 25 July 2024
Resolved
THE CARRIER, ITS AGENTS, AND ANY PERSON DESIGNATED FOR THIS PURPOSE BY THE CARRIER OR ITS AGENTS MUST PREPARE A DANGEROUS CARGO MANIFEST. IT MUST CONTAIN THE FOLLOWING INFORMATION: STOWAGE LOCATION OF HAZARDOUS MATERIAL ON BOARD.
PSCO OBSERVED NO STOWAGE LOCATIONS LISTED ON THE DANGEROUS CARGO MANIFEST FOR ANY HAZARDOUS MATERIAL ON BOARD.
49CFR176.30(a)(7)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 30 July 2024
Resolved 30 July 2024
Resolution: Fixed on the spot
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 3 June 2024
Resolved
Terminations and joints in all conductors shall be so made as to retain the original electrical, mechanical, fire/retarding, and where necessary, fire-resisting properties of the cable. PSCO found numerous deck lights with failed enclosure connections. 74 SOLAS(04)45.5.6
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2024
Resolved 18 July 2024
Resolution: Vessel provided Class Survey attesting to rectification of deficiency.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 3 April 2024
Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with additional requirements which may be established by the company. Due to the deficiencies of a technical and/or operational nature identified below which individually or collectively provides objective evidence of a serious failure, or lack of effectiveness of the ISM code. An external audit shall be conducted by the Flag Administration before vessel will be release from its detention to determine whether vessel is operating in compliance with the ISM code. A copy of the completed external audit shall be provided for USCG review prior to departure from the port of Mobile. 74 SOLAS (20)IX/3.1 ISM Code Part A/10.1
Action required: 30 - Ship detained
Resolved 5 April 2024
Resolution: Received external audit, reviewed and found satisfactory
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 3 April 2024
Resolved
The vessel’s safety management system should include procedures ensuring that non-conformities, accidents and hazardous situations are reported to the company, investigated and analyzed with the objective of improving safety and pollution prevention. Captain was unable to produce objective evidence that previously identified non-conformities were investigated and analyzed with the objective of improving safety and pollution prevention on board the M/V GSL ARCADIA. 74 SOLAS (20) IX/3.1 ISM Code Part A/9.1
Action required: 30 - Ship detained
Resolved 5 April 2024
Resolution: Received company record indicating crew received proper training for defect reporting system IAW company procedures.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company verification, review and evaluation
Issued 3 April 2024
Resolved
The company should establish procedures for the implementation of corrective action, including measures intended to prevent recurrence. PSCO observed multiple deficiencies recorded on the vessel’s SMS required quarterly reports that remain outstanding for more than one year without implementing correction action and communicating measures to prevent recurrence. 74 SOLAS (20) IX/3.1 ISM Code Part A/9.2
Action required: 30 - Ship detained
Resolved 5 April 2024
Resolution: Received company record indicating crew received proper training for defect reporting system IAW company procedures.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 April 2024
Resolved
In a ship in which oil fuel is used, the arrangements for the storage, distribution and utilization of the oil fuel shall be such as to ensure the safety of the ship and persons on board. PSCO observed main propulsion engine cylinder fuel oil leaks. Flag State surveyor also observed small oil leak on #1 auxiliary generator prime mover. Vessel SMS quarterly report indicates oil leaks was reported and remains outstanding since 12APR2022. 74 SOLAS (01) II-2/15.2
Action required: 30 - Ship detained
Resolved 5 April 2024
Resolution: PSCO received company statement verifying crew tightened leaking connections, and verified while onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 3 April 2024
Resolved
An embarkation ladder complying with the requirements of paragraph 6.1.6 of the code extending, in a single length, from the deck to the waterline in the lightest seagoing condition under all conditions of trim of up to 10° and a list of up to 20° either way shall be provided at each embarkation station or at every two adjacent embarkation stations for survival craft launched down the side of the ship. PSCO observed the lack of the embarkation ladder on the starboard side of the vessel making it impractical for the life raft required by 74 SOLAS (20) III/31.1.4 to be in a position ready for use. This issue made the liferaft unable to be launched and embarked within 5 minutes. 74 SOLAS (20) III/11.7
Action required: 30 - Ship detained
Resolved 5 April 2024
Resolution: Received class report and PSCO verified embarkation ladder was installed and verified in order.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 3 April 2024
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Flag state surveyor identified two cracks in way of port aft quarter cleat of starboard side life boat, company proactively scheduled life raft technician prior to USCG arrival. 74 SOLAS (20) III/20.2
Action required: 30 - Ship detained
Resolved 5 April 2024
Resolution: Received Class report and PSCO verified life boat technicians repaired both cracks on port quarter of starboard life boat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 April 2024
Resolved
An efficient bilge pumping system shall be provided, capable of pumping from and draining any watertight compartment other than a space permanently appropriated for the carriage of fresh water, water ballast, oil fuel or liquid cargo and for which other efficient means of pumping are provided, under all practical conditions. PSCO observed a temporary repair to bilge piping in the engine room that is compromised causing excess water in the engine room bilges. 74 SOLAS (04) II-1/26.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 April 2024
Resolution: Received Class report and PSCO verified, crew repaired leak by welding the pipe and is now in working order.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 April 2024
Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board. PSCO observed exhaust leak and jacket water leak on #2 generator. 74 SOLAS (04) II-1/26.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 April 2024
Resolution: Received Class report and PSCO verified crew repaired jacket water and exhaust leak and is in working order.
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 3 April 2024
Resolved
Every steam pipe and every fitting connected thereto through which steam may pass shall be so designed, constructed and installed as to withstand the maximum working stresses to which it may be subjected. PSCO observed steam emitting through lagging on lube oil purifier piping in the main machinery space. 74 SOLAS (04) II-1/33.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 April 2024
Resolution: Received Class report and PSCO verified repaired leak in lube oil purified and was found to be in good order.
08 - Alarms › N/A - No Subsystem › Emergency signal
Issued 3 April 2024
Resolved
In addition to the requirements elsewhere in the present regulations, ships shall be designed, constructed and maintained in compliance with the structural, mechanical, and electrical requirements of a classification society which is recognized by the Administration in accordance with the provisions of SOLAS 74 (04) regulation XI/1, or with applicable national standards of the Administration which provide and equivalent level of safety. PSCO observed inoperable bilge system high level audible and visual alarm in shaft alley. 74 SOLAS (04) II-1/3-1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 April 2024
Resolution: Received Class report and PSCO verified crew repaired alarm and is now operational.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 3 April 2024
Resolved
Oil fuel lines shall be screened for otherwise suitably protected to avoid, as far as practicable, oil spray or oil leakages onto hot surfaces, into machinery air intakes, or other sources of ignition. PSCO observed deteriorated lagging on various sections of oil system piping, located in way of port side engine room aft of the oily water separator, overhead near the HFO service tank, and the port passageway to the steering gear space. 74 SOLAS (01) II-2/15.2.11
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 April 2024
Resolution: Received Class report and PSCO verified crew replaced lagging and all are in good order.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 3 April 2024
Resolved
The means for securing and maintaining weather-tightness shall be to the satisfaction of the Administration. The arrangements shall ensure that the tightness can be maintained in any sea conditions. PSCO observed cargo hold ventilation cover on starboard side bay 59 was deteriorated and unable to close. ICLL Reg 16.4
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 April 2024
Resolution: Received Class report and PSCO verified cargo hold ventilation cover on starboard side bay 59 and showed that it is functioning properly.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 3 April 2024
Resolved
Electrical installations shall be such that electrical services essential for safety will be ensured under various emergency conditions. PSCO observed multiple deck lighting extinguished, to include but not limited to: lighting fitted on the bow to illuminate the port side anchor control system, illumination of aft mooring station, and illumination of starboard gangway. Presently, the lighting system does not provide adequate illumination at parts of the ship normally used by crew and utilized under various emergency conditions. 74 SOLAS (04) II-1/40.1.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 April 2024
Resolution: Received Class report and PSCO verified crew repaired lighting and is now operating properly.
10 - Safety of Navigation › N/A - No Subsystem › Voyage data recorder (VDR)/Simplified Voyage data recorder(S-VDR)
Issued 3 April 2024
Resolved
Voyage Data Recorder (VDR) must have a copy of the certificate of compliance issued by the testing facility, stating the date of compliance and the applicable performance standards and shall be retained on board the ship. Vessel could not produce a copy of the valid Certificate of Compliance for the approved VDR. 74 SOLAS (20) V/18.8
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 April 2024
Resolution: PSCO verified vessel received valid certificate of compliance for their approved VDR.
14 - Pollution Prevention › 148 - Ballast Water › Sediments
Issued 3 April 2024
Resolved
The master, owner, operator, agent, or person in charge of any vessel equipped with ballast water tanks that operates in the water of the United States must follow these practices: Rinse anchors and anchor chains when the anchor is retrieved to remove organism and sediments at their places of origin. PSCO observed accumulation of sediment on both of the vessel’s anchors. 33 CFR 151.2050(e)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 27 May 2024
Resolution: Vessel provided documentation from Class attesting to rectification.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 13 March 2019
Resolved
74SOLAS(04)Chapter II-1/43.3.1.2
code: 17AC
Where the emergency source of electrical power is a generator it shall be started automatically upon failure of the main source of electrical power and shall be automatically connected to the emergency switchbooard.
The emergency generator does not connect automatically to the emergency switchboard after failure of the main source of electrical power.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 20 March 2019
Resolved 18 March 2019
Resolution: The emergency switchboard control sequence was found with two defective time delays which class attests have been renewed. The Emergency Diesel Generator control sequences was tested successfully several times thereafter.