BAY LADY

BAY LADY is a 1988 passenger vessel (inspected). The Coast Guard has recorded 16 inspections since 2016, most recently in June 2026, along with 21 deficiencies and 1 operational control.

Records from 2016 to 2026. Most recent: inspection, 8 June 2026.

Built
1988
Last inspected
8 June 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDN3238
306977
Flag
UNITED STATES
Maury page id
psix-306977

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspections, by type

Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Registered dimensions (L × B × D)64.9 ft × 18.2 ft × 6.5 ft
Registered tonnagegross 38 / net 34
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWASHBURN & DOUGHTY ASSOCIATES INC · WOOLRICH, ME, UNITED STATES · built 1988
Hull materialSteel
PropulsionAuxiliary Sail
Hull shapeSail (Distinct Keel)
Hull configurationMonohull
Hailing portSEATTLE, WA
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational, Registry
DocumentationValid · issued 17 June 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it38 - Simplified, Gross Ton
34 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspection history · 16

8 June 2026 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8395372
7 October 2025 Deficiency Check · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8249113
3 March 2025 Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8087694
1 October 2024 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8012849
4 October 2023 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7796759
10 March 2023 Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7649155
1 August 2022 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7522520
7 July 2021 COI Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7247951
15 April 2021 Deficiency Check · Internal Structural Exam · Drydock Exam · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7175412
22 June 2020 COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6983683
4 September 2019 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6804016
2 April 2019 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6653915
1 October 2018 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6552731
13 July 2017 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6207179
16 March 2017 Drydock Exam · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6109961
8 July 2016 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5934382

Deficiency record · 21

09 - Working and Living Conditions › 092 - Working Conditions › Ropes and wires
Issued 7 October 2025 Resolved
Rigging materials and condition must meet the requirements of the intended service. The upper hank on the forward jib must be replaced before use. 46 CFR 176.25-5(a)(3), 177.300
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 November 2025
Resolved 8 November 2025
Resolution: Vessel replaced upper jib with a Wichard 110mm sail snap #6 Swedish hank.
09 - Working and Living Conditions › 092 - Working Conditions › Ropes and wires
Issued 7 October 2025 Resolved
Provide rigging inventory and preventative maintenance inspection program with index of components IAW NVIC 02-16. 46 CFR 176.802 (a)(3)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 November 2025
Resolved 8 November 2025
Resolution: Vessel provided rigging inventory and preventative maintenance inspection program but will have a more robust program next inspection.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 June 2020 Resolved
ALL PORTABLE AND SEMI-PORTABLE FIRE EXTINGUISHERS SHALL BE SERVICED BY A COAST GUARD APPROVED FIRE EXTINGUISHER SERVICING AGENCY ANNUALLY. A VESSEL'S CREMEMBER REPORTED/MI FOUND THAT THE 02 FIRE EXTINGUISHERS ONBOARD HAVE NOT BEEN SERVICED BY A COAST GUARD APPROVED FIRE EXTINGUISHER SERVICING AGENCY IN OVER 12 MONTHS. 46 CFR 107.235
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 June 2020
Resolution: Operator had all unserviced portable fire extinguishers serviced. Operator sent USCG invoice showing the service evidence.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 22 June 2020 Resolved
A VESSEL ON AN OCEANS, COASTWISE, AND LIMITED COASTWISE ROUTE MUST CARRY ONBOARD SIX HAND RED FLARE DISTRESS SIGNALS AND SIX HAND ORANGE SMOKE DISTRESS SIGNALS. MI FOUND THAT THE REQUIRED NUMBER OF FLARES WERE NOT FOUND ONBOARD. THE VESSEL'S CREWMEMBER RETRIEVED THE REQUIRED AMOUNT OF FLARES FROM THE VESSEL'S OFFICE AND PLACED ALL REQUIRED FLARES ONBOARD IN AN APPROVED PORTABLE WATERTIGHT CONTAINER. 46 CFR 180.68
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 22 June 2020
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 22 June 2020 Resolved
A VESSEL MUST CARRY EITHER A FIRST-AID KIT APPROVED UNDER APPROVAL SERIES 160.041 OR A KIT WITH EQUIVALENT CONTENTS AND INSTRUCTIONS. MI FOUND THAT THE CONTENTS FOUND IN THE VESSEL'S FIRST-AID KIT WERE OUTDATED. THE VESSEL'S CREWMEMBER RETRIEVED AND REPLACED ALL OUTDATED CONTENTS WITH CURRENT CONTENTS IN THE VESSELS FIRST-AID KIT. 46 CFR 184.740 46 CFR 160.041
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 22 June 2020
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 22 June 2020 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 22 June 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 June 2020 Resolved
THE TOTAL AMOUNT OF CHILD SIZE LIFE JACKETS EQUAL TO AT LEAST 10% OF THE NUMBER OF PERSONS PERMITTED ON BOARD. WITH A PASSENGER CAPACITY OF 90 PERSONS, THE VESSEL IS REQUIRED TO CARRY AT LEAST 09 CHILD SIZE LIFE JACKETS AS PER THE VESSEL'S CERTIFICATE OF INSPECTION. MI FOUND 07 CHILD SIZE LIFE JACKETS ONBOARD. THE VESSEL'S CREWMEMBER RETRIEVED AND SUPPLEMENTED THE MISSED CHILD SIZE LIFE JACKETS ONBOARD THE VESSEL. 46 CFR 180.71(b)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 22 June 2020
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 22 June 2020 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 22 June 2020
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 4 September 2019 Resolved
All piping, valves, and fittings shall be in accordance with good marine practice and suitable for the purpose attended. A minor leak was discovered in the discharge side of the fire pump. Leaking pipe must be removed and new pipe installed. 46 CFR 181.15-5(c)
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 October 2019
Resolved 31 January 2020
Resolution: Leaking pipe has been replaced
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 September 2019 Resolved
The engine head, block and exhaust manifold shall be water jacketed and cooled by water from a pump which operates whenever the engine is operating. Leak was discovered in a flexible hose from jacket water heat exchanger to the exhaust. Flexible hose must be replaced. 46 CFR 181.20-10(b)(1)
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 October 2019
Resolved 31 January 2020
Resolution: Vent on flexible hose was replaced, stopping the leak
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 4 September 2019 Resolved
The power fire pump may be driven off a propulsion engine. Belt tensioner on the fire/bilge pump system is seized. Belt tensioner must be replaced, or maintenance conducted to repair the tensioner. 46 CFR 181.10-1(d)
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 October 2019
Resolved 31 January 2020
Resolution: Belt tensioner was replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Radio life-saving appliances
Issued 4 September 2019 Resolved
Stations in the maritime service must be licensed by the FCC. FCC Station License is expired. FCC Station License must be renewed. 47 CFR 80.13(a)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 October 2019
Resolved 31 January 2020
Resolution: New FCC cert recieved
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 September 2019 Resolved
Check the condition of the super structure, flying bridge and masts. In sailing vessels, inspect all spars, standing rigging, running rigging, blocks, fittings and sails. Aft stanchions of the fife rail have corrosion, with significant lose of material. Stanchions must be cropped and renewed at next dry dock. 46 CFR 176.25-5(a)(3)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 March 2021
Resolved 12 May 2021
Resolution: Fife rail stanchions were cropped and renewed. Welds are satisfactory.
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 1 October 2018 Resolved
Provide GPS enabled DSC VHF radio and new FCC Saftey Radio Certificate. Vessel restricted from operating in Sea Area A1 until corrected.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 November 2018
Resolved 25 January 2019
Resolution: GPS enabled radio installed.
01 - Certificates & Documentation › 013 - Documents › Shipboard working arrangements
Issued 1 October 2018 Resolved
Provide sail rigging preventative maintenance plan for review.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 November 2018
Resolved 25 January 2019
Resolution: PMP submitted for review.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 October 2018 Resolved
Crop and renew port aft winch foundation at next credit drydock.
Action required: 705 - Other - as specified
Due 31 March 2019
Resolved 2 April 2019
Resolution: Completed during dry dock
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 1 October 2018 Resolved
Prove proper operation of remote fuel shutoffs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 October 2018
Resolution: New shutoff cable installed and tested.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 1 October 2018 Resolved
Re-install missing pipe hangers on bilge system piping.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 January 2019
Resolution: Bilge pipe hangers installed.
Fire Fighting › Fire Hoses › Connections
Issued 13 July 2017 Resolved
Provide functional fire hose for forward fire hydrant. 46CFR181.15-10
Condition: Damaged By Earlier Event
Due 20 July 2017
Resolved 20 July 2017
Resolution: Observed forward fire hose properly connected.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 26 July 2016 Resolved
Portable fire extinguishers need to be serviced. 46 CFR 181.30-1
Action required: 705 - Other - as specified
Due 2 August 2016
Resolved 1 August 2016
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 26 July 2016 Resolved
Seal wire penetration in aft bulkhead of engine room. 46CFR182.35-1(a)
Action required: 705 - Other - as specified
Due 2 August 2016
Resolved 1 August 2016

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.