MAURY USCG vessel records Sign in
← All vessels

AMBER L

AMBER L is a 2000 freight ship. The Coast Guard has recorded 17 inspections since 2000, most recently in February 2017, along with 13 deficiencies — 1 with no resolution recorded — and 3 operational controls.

Records from 2000 to 2017. Most recent: operational control imposed, 24 February 2017.

Built
2000
Last inspected
23 February 2017
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9200354 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
PANAMA
—
Maury page id
psix-307

Inspections, by type

…with no type recorded5
Years with a record 10 calendar years (2000–2017)
The 17 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it16173 - Convention (Subpart B), Net Ton
25955 - Convention (Subpart B), Gross Ton
54318 - Displacement, Ton
47282 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 17

23 February 2017 Deficiency Check · Ballast Water Examination · ISPS II Exam · PII Safety Exam · Administrative Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6088794
14 October 2010 COE-Administrative
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3868851
9 September 2010 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3846897
13 May 2008 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3205454
30 January 2007 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2863804
25 January 2007 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2861485
1 March 2006 Deficiency Check
Physical examination · MSFO NEW BEDFORD · USCG Northeast District (CGD-NE) · Activity 2594103
12 October 2005 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2512741
21 September 2005 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2497718
21 September 2005 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2498129
16 August 2004 ISPS II Exam
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2167276
27 April 2004 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2055428
26 April 2004 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2101283
2 March 2004 Annual Inspection · Ballast Water Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2016710
5 November 2002 MARPOL Annex I Examination · Annual Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 1695618
18 January 2001 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 285951
24 January 2000 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 273846

Deficiency record · 13

Engineering › Diesel Engine (propulsion-direct drive) › Cylinder
Issued 23 February 2017 Resolved
1410 - The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Cylinder number one is leaking cooling water. - SOLAS '74 ('14 CONS) I/11(a) - 30ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 23 February 2017
Resolved 26 February 2017
Resolution: Received, reviewed and accepted class report from [name withheld] stating the deficiency was rectified. PSC Officers attended vessel and verified no leaking from #1 M/E cylinder.
Communications › Alarms/Indicators › Steering Failure Alarm System
Issued 23 February 2017 Resolved
1499 - In the event of a failure of electrical power supply to the control system, an audible and visual alarm shall be given on the navigation bridge. When testing #1 and #2 steering systems the loss of power alarms are not activating on the navigation bridge. - SOLAS '74 ('04 CONS) II-I/29.5.2 - 30ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 23 February 2017
Resolved 26 February 2017
Resolution: Received, reviewed and accepted class report from [name withheld] stating the deficiency was rectified. PSC Officers attended vessel and witnessed steering tests. PSC Officers found proper operation of audible and visual alarms.
Communications › Alarms/Indicators › Steering Failure Alarm System
Issued 23 February 2017 Resolved
1499 - All the steering gear components and the rudder stock shall be of sound and reliable construction to the satisfaction of the administration. The hydraulic lock alarms for the #1 and #2 steering systems sounded during tests of each steering system from the bridge while in follow-up and non-follow-up modes. - SOLAS '74 ('04 CONS) II-I/29.2.1 - 17abc
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 23 February 2017
Resolved 26 February 2017
Resolution: Received, reviewed and accepted class report from [name withheld] stating the deficiency was rectified. PSC Officers witnessed steering test with no hydraulic lock alarms in either mode on either pump.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 23 February 2017 Resolved
0999 - The cond of the ship and its equip shall be maintained to conform with the provisions of the present regs to ensure that the ship in all respects will remain fit to proceed to sea w/o danger. Vent piping to forepeak ballast tank in bosun hold has a 5"-6" section removed. There is no shut off valve to prevent internal flooding from the forepeak ballast tank- SOLAS '74 ('14 CONS) I/11(a)-17ac
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 23 February 2017
Resolved 26 February 2017
Resolution: Received, reviewed and accepted class report from [name withheld] stating the deficiency was rectified. PSC Officers attended vessel and verified deficiency was rectified.
Documentation › Safety Management System › Conformity Maintenance Procedures
Issued 23 February 2017 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 17 - Rectify deficiencies prior to departure
Due 23 February 2017
Resolved 26 February 2017
Resolution: Flag State conducted SMS training.
Fire Fighting › Structural - Main Vertical Zones › General
Issued 23 February 2017 No resolution recorded
0750 FIRE PREVENTION: Where "A" class divisions are penetrated for the passage of electric cable, pipes, trunks, ducts, etc., arrangements shall be made to ensure that the fire resistance is not impaired. Vessel was unable to provide documentation stating the material used in the cable penetrations on al decks is fire resistant. SOLAS'74(01 CONS)II-2/18.1.1 40ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Fire Fighting › Structural - A Class Divisions › External Escape Routes
Issued 23 February 2017 Resolved
0750 FIRE PROTECTION: Doors fitted in boundary bulkheads of machinery spaces of category "A" shall be reasonably gastight and self-closing. Self-closing door from the engine room into the emergency escape trunk on the lower level, forward, starboard side had the self-closing device removed. SOLAS '74(01 CONS) II-2/47.1 10c
Due 23 February 2017
Resolved 23 February 2017
Resolution: Vessel crew re-installed the self-closing device witnessed by PSC officers.
Lifesaving › Embarkation Appliances/Stations › Accessability
Issued 23 February 2017 Resolved
0699 OTHER (LIFE-SAVING APPLIANCES) Muster and embarkation stations shall be adequately illuminated by lighting supplied from the emergency source of electrical power. 03 lights near lifeboat embarkation and rescue boat embarkation were found extinguished.
Due 23 February 2017
Resolved 23 February 2017
Resolution: Vessel crew replaced extinguished lights. PSC officers witnessed proper illumination.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 23 February 2017 Resolved
0699 OTHER (LIFE-SAVING APPLIANCES) Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. One lifebuoy was found not operational. SOLAS 74(14CONS) III/20.10 10c
Due 23 February 2017
Resolved 23 February 2017
Resolution: Vessel crew replaced buoy light. PSC officers witnessed properly operation.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 25 January 2007 Resolved
Forward bulkhead of stbd diesel tank at Frame #15 has a pin-hole leak in way of longitudinal bulkhead. SOLAS 74/78 II-2/4.1.1
Action required: 705 - Other - as specified
Due 25 February 2007
Resolved 29 January 2007
Resolution: Class report was issued stating permanent repairs are to be completed by 16 Feb 2006
Documentation › Certificates/Documents › IOPP Certificate
Issued 21 September 2005 Resolved
IOPP certificate information referencing the waste oil service tank is inaccurate. Actual tank capacity is 1.2 cubic meters. IOPP states tank capacity as being 1.0 cubic meters. Cite 33 CFR 151.17(d)
Action required: 705 - Other - as specified
Due 21 October 2005
Resolved 12 October 2005
Resolution: Recived fax from Class attesting to the capacity of the waste oil service tank being 1.0. Chief Engineer is too modify Oil Record book to comply with Classes findings.
Navigation › Collision/Grounding Avoidance
Issued 29 April 2004 Resolved
Vessel was involved in a grounding, the uncertainty of the condition of the vessel could pose a hazard to the crew, vessel, and port. Vessel must have a dive survey, a class survey report detailing the extent of the damage, a flag state report verifing that the vessel is fit for route and service.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 April 2004
Documentation
Issued 24 January 2000 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 25 January 2000
Resolved 25 January 2000

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.