PRIDE is a 1988 passenger vessel (inspected). The Coast Guard has recorded 104 inspections since 1988, most recently in December 2025, along with 191 deficiencies, 1 operational control and 2 casualty investigations between 2008 and 2019.

Records from 1988 to 2025. Most recent: inspection, 12 December 2025.

Built
1988
Last inspected
12 December 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDD7286
307794
Flag
UNITED STATES
367184390
Maury page id
psix-307794

Inspections, by type

…with no type recorded20
Years with a record 35 calendar years (1988–2025)
The 104 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)60.2 ft × 18.1 ft × 8.5 ft
Registered tonnagegross 57 / net 45
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMETAL TRADES INC & MARTHAI · YONGES ISLAND, SC, UNITED STATES · built 1988
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portCHARLESTON, SC
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 4 May 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it57 - Regulatory (Subpart C or D), Gross Ton
45 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDD7286MMSI 367184390 · active · compulsorily equipped · granted 22 March 2017, expires 2 May 2027 · licensed under a name not among this hull’s recorded names (not shown)
WCZ7483MMSI not assigned · expired · compulsorily equipped · granted 11 April 2000, cancelled 12 June 2010 · licensed under a name not among this hull’s recorded names (not shown)
WTA9993MMSI not assigned · expired · compulsorily equipped · granted 3 January 1995, cancelled 26 February 2005
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 104

12 December 2025 Vessel Attendance · Drydock Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8282623
6 October 2025 Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8247105
30 September 2024 Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8011909
5 December 2023 Drydock Exam · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7833045
6 November 2023 Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7820913
9 March 2023 Damage Survey · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7648456
5 December 2022 In-Service Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7604664
6 September 2022 COI Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7538307
10 December 2021 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7359302
10 November 2021 Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7348344
27 July 2021 Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7269387
23 October 2020 Examination of Repairs · Deficiency Check · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7083095
7 February 2020 Hull Examination · Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6904678
21 October 2019 Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6838920
16 August 2019 Damage Survey
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6785119
15 August 2019 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6785520
9 October 2018 Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6557252
24 January 2018 Drydock Exam · Examination of Repairs · Hull Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6343673
7 September 2017 DAPI Audit · COI Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6260862
15 November 2016 Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6042603
27 October 2016 Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6030200
24 December 2015 Hull Examination · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5786729
8 September 2015 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5234157
12 July 2012 COI Inspection · DAPI Audit · Deficiency Check · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4376329
25 January 2012 Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4231560
8 December 2011 Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4203782
5 July 2011 Annual Inspection · In-Service Inspection · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4069873
8 May 2009 Administrative Inspection · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3470183
5 May 2009 Annual Inspection · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3463020
13 July 2008 Type not recorded
No type recorded · Station Charleston · USCG Southeast District (CGD-SE) · Activity 3271556
12 July 2008 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3267556
30 January 2008 Deficiency Check · Administrative Inspection · COI Inspection · Drydock Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3132136
21 March 2007 Administrative Inspection · Hull Examination · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2892258
17 March 2006 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2604325
15 February 2006 Hull Examination · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2585822
27 January 2005 Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2282330
25 October 2004 Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2229406
15 January 2004 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1984793
27 October 2003 Annual Inspection · Deficiency Check · In-Service Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1937084
26 June 2003 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1827485
17 May 2003 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1814013
11 February 2003 Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1744047
17 October 2002 COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1691137
4 April 2001 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1061320
19 March 2001 COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1410507
16 March 2001 Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1464346
11 February 2000 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 815370
5 November 1999 Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1446841
26 April 1999 Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1456687
18 August 1998 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 796619
20 May 1998 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1126035
29 April 1998 Administrative
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1123795
3 April 1998 COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1364661
4 March 1998 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 783973
12 August 1997 Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1364308
26 June 1997 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1112338
10 May 1997 Administrative
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1100328
18 April 1997 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1105424
6 March 1997 Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1460067
28 January 1997 Plan Review "T" Boat
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1102820
22 July 1996 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1089946
30 May 1996 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1085546
19 April 1996 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1084000
18 April 1996 Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1435752
8 March 1996 Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 885686
16 January 1996 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 872251
8 January 1996 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1190359
13 December 1995 Plan Review "T" Boat
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1189314
8 December 1995 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 876474
27 April 1995 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 866737
4 April 1995 COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1147156
3 January 1995 Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1163380
16 September 1994 Excursion Permit
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 867576
18 August 1994 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 225433
5 August 1994 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 855669
27 July 1994 COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1179168
14 July 1994 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 134299
14 May 1994 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 217999
12 October 1993 Administrative
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 829985
19 September 1993 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 152518
19 September 1993 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 223773
10 September 1993 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1144598
16 August 1993 Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1154757
5 July 1993 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 13071
17 December 1992 Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 834035
27 July 1992 Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 955166
25 June 1992 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1267267
10 January 1992 Plan Review "T" Boat
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1263422
18 December 1991 Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1261442
29 July 1991 Administrative
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1309524
25 July 1991 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1252048
18 July 1991 COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 904600
25 September 1990 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1216053
1 September 1990 Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1239296
22 August 1990 Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 915123
24 July 1990 Administrative
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1233981
13 July 1990 Plan Review "T" Boat · Initial Construction-Excluding Oversight
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1223742
24 May 1990 Administrative
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1223741
28 December 1989 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 917486
13 October 1989 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1039020
8 August 1989 Hull Examination · Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1207929
31 March 1989 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1341301
9 December 1988 Construction Oversight
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1213688
4 August 1988 Hull Examination · Initial Certification
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1209324

Deficiency record · 191

07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 October 2025 Resolved
Unless other means are provided to ensure that a potential waste receptacle fire would be limited to the receptacle, waste receptacles must be constructed of noncombustible materials with no openings in the sides or bottom. Vessel had 02 combustible plastic waste receptacles on board.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 November 2025
Resolved 17 October 2025
Resolution: O/O replaced or removed combustible trash cans.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 October 2025 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected. 01 portable diesel fuel tank was located in the aft salon space. Fuel tank was taken off the vessel during the inspection.
Action required: 10 - Deficiency Rectified
Resolved 6 October 2025
Resolution: O/O removed fuel tank from the vessel.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 30 September 2024 Resolved
Waste receptacles must be constructed of non-combustible materials with no openings in the sides or the bottom. MI identified plastic waste receptacles which must be replaced with similar sized non-combustible type. 46 CFR 177.405(f)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2024
Resolved 24 October 2024
Resolution: Vessel provided the required non-combustible trash cans on the vessel. All Sat.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 6 September 2022 Resolved
A pre-engineered fixed gas fire extinguishing system must: Automatically shut down all power ventilation systems and all engines that draw intake air from within the protected space. The pre-engineered fixed gas extinguishing system on-board did not shut down power to the main diesel engine.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 November 2022
Resolved 7 September 2022
Resolution: Vessel engineer worked with system technician to ensure proper connection and operation. MIs witnessed satisfactory operational test.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 6 September 2022 Resolved
A vessel, on which a pre-engineered fixed gas fire extinguishing system is installed, must have the following equipment at the operating station: A light to indicate discharge. Vessel did not have a light indicating discharge at the operating station.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 October 2022
Resolved 27 February 2023
Resolution: Deficiency recitfied.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 6 September 2022 Resolved
Electrical equipment on a vessel must be installed and maintained to: Minimize accidental personnel contact with energized parts. Exposed wires were discovered running from the GPS receiver for the weather deck to the cabin.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 October 2022
Resolved 7 October 2022
Resolution: Operator provided photos of old electrical equipment removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 September 2022 Resolved
The bilge suctions shall be fitted with suitable strainers having an open area not less than three times the area of the bilge pipe. The aft bilge suction line was not fitted with a strainer.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 October 2022
Resolved 7 October 2022
Resolution: Operator provided photos of strainer installed.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 6 September 2022 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. Medicine in the first-aid kit was expired.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 October 2022
Resolved 29 September 2022
Resolution: Vessel operator provided documentation of new CG approved first-aid kit.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 6 September 2022 Resolved
The operator of each self-propelled vessel 12 meters or more in length shall carry, on board and maintain for ready reference, a copy of these Rules. Vessel did not have a current copy of the Navigation Rules onboard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 October 2022
Resolved 29 September 2022
Resolution: Vessel operator provided documentation of new navigation rules book.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 6 September 2022 Resolved
Employers must ensure that they and their crew members meet the requirements of this part. Vessel operator was unable to produce a list of the employees included in the DAPI program.
Action required: 10 - Deficiency Rectified
Resolved 6 September 2022
Resolution: Vessel o/o provided documentation of enrollment, random tests, and new hire tests for employees.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 10 November 2021 Resolved
Each Class 1 door on a vessel in ocean service must be designated to withstand a head of water equivalent to the depth from the sill of the door to the margin line but in no case less than 10 feet. Gasket on aft watertight door was warped and unable to make full contact with knife edge. 46 CFR 170.270(b) OLD T
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 November 2021
Resolved 24 November 2021
Resolution: New gasket was chalk tested with satisfactory results.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 10 November 2021 Resolved
Stability information (stability details indicated on the Certificate of Inspection, a stability letter, or a stability booklet), is required on certain vessels by paragraphs (b), (c), or (d) of this section. Current sail plan stamped "Return for Revision" and dated 1 year prior to approved Stability Letter. Updated/approved sail plan required.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 November 2021
Resolved 15 November 2021
Resolution: Vessel owner located approved Sail Plan.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 November 2021 Resolved
An adult life jacket must be provided for each person carried on board a vessel. Vessel missing 03 Type I life jackets. Restricted to 46 adult passengers until life jackets are provided.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 November 2021
Resolved 15 November 2021
Resolution: Vessel owner supplied 03 Adult type I life jackets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 November 2021 Resolved
Each lifejacket carried on a vessel engaged in ocean, coastwise, or Great Lakes route, must have a life jacket light that is approved in accordance with 160.012 in subchapter Q. It must be securely attached to the front shoulder of the lifejacket. Missing lifejacket light on 01 child life jacket. Restricted to 04 passengers under 90 lbs until light is supplied.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 November 2021
Resolved 15 November 2021
Resolution: Vessel owner supplied missing life jacket light.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 10 November 2021 Resolved
The water light must be- Of an approved automatic electric type, constructed in accordance with Subpart 161.010 of this chapter, except as allowed under paragraph (d)(2) of this section. Vessel's life float water light batteries expired in 2019 and 2015. Vessel restricted to operating within Lake, Bays, and Sounds.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 November 2021
Resolved 30 November 2021
Resolution: Recieved photograph of two new waterlight batteries. Exp dates: 03/24 & 01/24
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 10 November 2021 Resolved
The master of the vessel shall ensure that the EPIRB's battery is replaced after it is used or before the date required by FCC regulations in 47 CFR part 80. Vessel's EPIRB battery replaced and dated by Master. Battery must be replaced per manufacturer's instruction.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 November 2021
Resolved 24 November 2021
Resolution: Vessel installed new EPIRB.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 November 2021 Resolved
Fire hazards to be minimized. The general construction of the vessel must be such as to minimize fire hazards insofar as it is reasonable and practicable. Flammable paint/thinner stored in accommodation space.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 24 November 2021
Resolved 10 November 2021
Resolution: Paint/thinner removed from vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 November 2021 Resolved
Twist-on type connectors may not be used for making joints in cables, facilitating a conductor splice, or extending the length of a circuit. Wire nut used on wiring for MSD pump.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 November 2021
Resolved 15 November 2021
Resolution: MSD pump rewired with butt connectors.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 November 2021 Resolved
Batteries shall be so located that the gas generated in charging will be easily dissipated by natural or induced ventilation. Batteries should not be located in the same compartment with a gasoline tank or gasoline engine, but where location elsewhere is impracticable, they shall be effectively screened by a cage or similar structure to minimize the danger of accidental spark through dropping a metal object across terminals. Vessel's batteries missing protective covering. 46 CFR 183.05-20(a) OLD T
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 November 2021
Resolved 19 November 2021
Resolution: Batteries fitted with covers.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 10 November 2021 Resolved
All escape hatches and other emergency exits shall be marked on both sides using at least 1-inch letters: "Emergency Exit, Keep Clear", unless such markings are deemed unnecessary by the Officer in Charge, Marine Inspection. Aft emergency exit missing required marking. 46 CFR 185.30-15(a) OLD T
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 November 2021
Resolved 15 November 2021
Resolution: Emergency exit marked as required.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 26 October 2020 Resolved
Each item of lifesaving equipment with an expiration date on it must be replaced if the expiration date has passed. Vessel's EPIRB battery expired in 07/2020. Vessel is restricted to operating within 3 miles from shore until battery is replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 24 November 2020
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 26 October 2020 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in a serviceable condition must be repaired or replaced. Vessel's life float has damaged areas in which the crew attempted to repair. Submit a repair proposal to the USCG on how the vessel plans to repair areas in accordance with manufacturer instructions. Vessel restricted to a lakes, bays and sounds route within one mile of land.
Action required: 705 - Other - as specified
Resolved 12 January 2021
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 26 October 2020 Resolved
Each survival craft must be stowed so that when the vessel sinks the survival craft floats free. Vessel's life floats are covered by a heavy piece of wood and a zipped cover. Vessel to submit a proposal of another arrangement for the life floats.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 November 2020
Resolution: Vessel is allowed to remove liferaft as per COI.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 26 October 2020 Resolved
A vessel on a coastwise route must carry six hand red flare distress signals and six hand orange smoke distress signals. Vessel only has eight red hand distress flares onboard and is restricted to a lakes, bays and sounds route.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 12 January 2021
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 26 October 2020 Resolved
The owner of a documented vessel must annually renew each endorsement upon the current Certificate of Documentation for that vessel in accordance with 67.163. Vessel has an expired COD onboard. Vessel restricted from operating until vessel representative can provide proof to the attending marine inspector that vessel has submitted for its COD.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 March 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 October 2020 Resolved
At each inspection all observed unsafe practices and fire hazards must be corrected and all required protective devices must be in satisfactory condition. Vessel's stbd fuel shut off valve was did not close.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 9 December 2021
Resolution: Superseded or corrected during a subsequent inspection.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 26 October 2020 Resolved
Whenever deterioration to hull plating that may affect seaworthiness of the vessel is discovered the OCMI may require the vessel to effect permanent repairs. In the anchor locker, port side approximately 5' above the waterline there is significant pitting. Vessel to submit a repair proposal on how to address area.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 January 2021
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 21 October 2019 Resolved
Replace port running light lens.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 February 2020
Resolution: A new nav light was placed in service.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 October 2019 Resolved
provide servicing to B/C: 40 portable extinguisher for forward compartment
Action required: 10 - Deficiency Rectified
Resolved 21 October 2019
Resolution: The B/C: 40 was serviced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 October 2019 Resolved
Show proper operation of aux. steering.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 February 2020
Resolution: Tested aux steering, sat.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 21 October 2019 Resolved
Show proof of current Marine Operators License.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 November 2019
Resolution: Captain received a Marie operator's permit.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 October 2019 Resolved
Place in service belt guard for propulsion engine.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 February 2020
Resolution: A new guard was placed in service.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 October 2018 Resolved
STBD F/O cut off valve will not completely close properly.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 October 2018
Resolved 17 October 2018
Resolution: Adjusted valve
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 9 October 2018 Resolved
Hydro static release on the EPIRB was expired
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 October 2018
Resolved 17 October 2018
Resolution: Replaced hydrostatic release
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 October 2018 Resolved
Dead end wires in the engine room not properly terminated
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 October 2018
Resolved 17 October 2018
Resolution: Terminated dead end wires in electrical box
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 October 2018 Resolved
Local start button temporarily mounted
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 October 2018
Resolved 17 October 2018
Resolution: Mounted the start button on fwd e/r bulkhead
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 October 2018 Resolved
Non-metallic fuel filter installed in E/R
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 November 2018
Resolved 9 December 2021
Resolution: Superseded or corrected during a subsequent inspection.
Lifesaving › Lifefloat › Serviceable
Issued 27 October 2016 Resolved
Both lifefloats had damage to their exterior shells, exposing the foam core. Service both lifefloats to ensure proper operation. Reduce route to LBS while life floats are off the vessel.
Action required: 705 - Other - as specified
Due 27 November 2016
Resolved 15 November 2016
Fire Fighting › Means of Escape › Blocked
Issued 27 October 2016 Resolved
On deck bracket holding life floats was partially impeding the aft emergency escape route. Modify arrangement of life float bracket so that it does not impede the aft emergency escape route.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 27 November 2016
Resolved 15 November 2016
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 12 October 2012 Resolved
Unable to provide proof of company-run EAP program.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 November 2012
Resolved 17 November 2012
Resolution: Company posted EAP information for employees with resources to contact.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 12 October 2012 Resolved
Unable to provide proof of annual MIS submission.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 November 2012
Resolved 17 November 2012
Resolution: Company submitted annual MIS data on October 22, 2012.
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 20 September 2012 Resolved
Vent piping for port and starboard fuel tanks were missing required flame screens.
Due 20 October 2012
Resolved 18 October 2012
Resolution: Flame screens installed satisfactory.
Lifesaving › Lifebuoys › Serviceable
Issued 20 September 2012 Resolved
All ring lifebuoys on vessel were cracked and unserviceable.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 September 2012
Resolution: New, properly labeled liferings installed.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 20 September 2012 Resolved
06 adult lifejackets were identified as not having adequate reflective material. Vessel is restricted to 48 passengers (# of properly marked adult lifejackets) until reflective material is added.
Due 20 October 2012
Resolved 20 September 2012
Resolution: Six adult lifejackets serviced with retro-reflective tape and are now serviceable.
Lifesaving › Lifefloat › Retroreflective Material
Issued 20 September 2012 Resolved
The reflective material on both of the vessel's required life floats was inadequate.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 September 2012
Resolution: Two 12 -man life floats have been serviced to include addition of retro-reflective tape.
Navigation › Piloting/Steering › Magnetic Compass
Issued 20 September 2012 Resolved
Vessel did not have an illuminated magnetic compass installed.
Due 20 October 2012
Resolved 18 October 2012
Resolution: Lighted magnetic compass installed.
Operations/Management › Drug and Alcohol Testing › Testing, Random
Issued 20 September 2012 Resolved
Vessel operator was unable to provide proof showing that 50% of the vessel employees were being randomly tested for drug use on an annual basis.
Due 20 October 2012
Resolved 12 October 2012
Resolution: DAPI Chemical Testing Program Compliance Audit completed. 100% of crew (~25 employees) completed random testing.
Electrical › Electrical Distribution System (service) › Wiring
Issued 20 September 2012 Resolved
Dead-end wiring was found in both forward and aft cabins.
Due 20 October 2012
Resolved 18 October 2012
Resolution: Dead-end wires removed from forward and aft cabin satisfactory. Minor modifications to include electrical wiring continues.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 20 September 2012 Resolved
Cover plates and wire collar supports for 02 junction boxes, both located behind galley refrigerator, were missing.
Due 20 October 2012
Resolved 18 October 2012
Resolution: Two junction cover plates installed behind refrigerator in crew galley.
Engineering › Bilge Water Management System › Piping
Issued 20 September 2012 Resolved
Vital bilge piping system is comprised of PVC piping and required to be ferrous material. O/O required to submit plan to re-fit bilge piping system with ferrous material. 10/17/2012: Plan received to replace PVC piping in bilge with ferrous material during hull exam period while in drydock during January 2013.
Action required: 705 - Other - as specified
Due 14 February 2013
Resolved 15 March 2013
Resolution: Bilge piping replaced. Complete case work for this deficiency is attched to activity on 03/15/2013.
Deck/Cargo › Mooring/Anchoring › Mooring Line/Hawser
Issued 20 September 2012 Resolved
The port spring line is worn and no longer adequate for safe mooring of vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 September 2012
Resolved 20 September 2012
Resolution: Spring line replaced.
Sail Rigging › Spars › Boom and Gooseneck Fitting
Issued 20 September 2012 Resolved
A crack was discovered on the jib-boom gooseneck; passengers are restricted to aft of the foremast until repairs are complete.
Due 20 October 2012
Resolved 18 October 2012
Resolution: Inspected new jib-boom gooseneck; sat.
Lifesaving › Hand Flares › Quantity
Issued 6 July 2011 Resolved
Provide proper number of flares for Coastwise route (6 day, 6 night). Vessel is limited to Lakes, Bays, and Sounds route.
Action required: 705 - Other - as specified
Due 20 July 2011
Resolved 6 July 2011
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 6 July 2011 Resolved
Properly repair navigation light wiring. Vessel restricted to daytime/good visibility operations
Condition: Improper Installation
Due 20 July 2011
Resolved 6 July 2011
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 6 July 2011 Resolved
Remove or secure construction materials in forward compartment prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 July 2011
Electrical › Electrical Distribution System (service) › Junction Box
Issued 6 July 2011 Resolved
Install junction box around electrical connections with wire nuts or replace with crimp connectors.
Due 20 July 2011
Resolved 21 July 2011
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 July 2011 Resolved
All dead end wiring must be removed or blanked off and labeled.
Due 20 July 2011
Resolved 21 July 2011
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 6 July 2011 Resolved
Remove all flammable liquids from vessel or properly stow in flammable liquid locker.
Due 20 July 2011
Resolved 21 July 2011
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 6 July 2011 Resolved
Replace life buoy lifelines in accordance with 46 CFR 180.70
Due 20 July 2011
Resolved 21 July 2011
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 6 July 2011 Resolved
Install double hose clamps on exhaust system in engine room.
Due 20 July 2011
Resolved 21 July 2011
Construction/Loadline › Structures › Superstructure
Issued 6 July 2011 Resolved
Replace topmast job stay turnbuckle and toggle.
Due 20 July 2011
Resolved 28 July 2011
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 5 July 2011 Resolved
Demonstrate proper operation of override switch on fixed fire fighting system.
Due 28 July 2011
Resolved 28 July 2011
Engineering › Bilge Water Management System › Interface Detector
Issued 5 May 2009 Resolved
Properly repair stern void high bilge alarm.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 May 2009
Resolved 5 May 2009
Resolution: Mechanic replaced high bilge alarm switch. This corrected the problem.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 5 May 2009 Resolved
Block off all open breaker slots on vsl's pwr distribution panel.
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 June 2009
Resolved 16 June 2009
Electrical › Electric Supply System (service) › Battery Installation
Issued 5 May 2009 Resolved
Secure all batteries and provide terminal covers for the same.
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 June 2009
Resolved 5 May 2009
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 May 2009 Resolved
Properly remove dead end wiring on vsl's power distribution panel.
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 June 2009
Resolved 16 June 2009
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 5 May 2009 Resolved
Properly stencil vsl's name on all child life jackets.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 5 June 2009
Resolved 16 June 2009
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 5 May 2009 Resolved
Replacing missing B-II fire extinguisher, vsl missing one B-II extinguisher in fwd storage compartment iaw with qty on COI.
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 May 2009
Resolved 5 May 2009
Resolution: Owner purchased a new B-II extinguisher and mounted in the fwd storage compartment during our inspection.
Electrical › Lighting (service) › Lighting Fixture
Issued 5 May 2009 Resolved
Properly wire in two overhead florescent light fixtures in the fwd cabin overhead. Found permanent light fixtures wired into a 110 power strip with three prong plugs.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 5 June 2009
Resolved 16 June 2009
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 5 May 2009 Resolved
Missing one adult type-I life-jacket, max passenger reduced to 53 max passengers and crew.
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 June 2009
Resolved 16 June 2009
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 5 May 2009 Resolved
Properly mark all life jacket storage compartments.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 5 June 2009
Resolved 16 June 2009
Lifesaving › Lifebuoys › Serviceable
Issued 5 May 2009 Resolved
Properly install four bands of SOLAS retro-flective tape onto vsl's life ring buoys.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 June 2009
Resolved 16 June 2009
Communications › Visual Communication › Warning Sign (gangway)
Issued 5 May 2009 Resolved
Properly mark vsl's aft cabin escape hatch on the inside and outside of the hatch.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 June 2009
Resolved 16 June 2009
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 5 May 2009 Resolved
Provide engine room vent closure device, vsl has a pre engineered (automatic) fire extinguishing system.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 5 June 2009
Resolved 16 June 2009
Communications › Radio Communications › EPIRB
Issued 5 May 2009 Resolved
Renew expired battery in vsl's EPIRB.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 June 2009
Resolved 7 August 2009
Construction/Loadline › Structures › Transverse Bulkhead
Issued 30 January 2008 Resolved
Properly cap off all stuffing tubes in vsl's collision bulkhead.
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 February 2008
Resolved 21 March 2008
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 30 January 2008 Resolved
Properly repair all emergency lighting and install additional e-lighting in vsl's aft cabin and engine room.
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 February 2008
Resolved 21 March 2008
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 30 January 2008 Resolved
Install safety pin and seal on vsl's engine room fire extinguisher. Have onboard required number of fire extinguisher I.A.W. vsl's COI. Missing one B-I extinguisher.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 February 2008
Resolved 21 March 2008
Engineering › Bilge Water Management System › Interface Detector
Issued 30 January 2008 Resolved
Properly repair aft cabin bilge alarm.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 March 2008
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 30 January 2008 Resolved
At vsl's next dry-dock permanently mark draft marks or loaded reference mark IAW vsl's stability letter.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 21 March 2008
Lifesaving › Visual Distress Signals (General) › Quantity
Issued 30 January 2008 Resolved
Have onboard proper number of day/night VDS's 6 day/6 night. Currently missing 6 night time VDS's.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 March 2008
Lifesaving › Buoyant Apparatus › Float-free Link
Issued 30 January 2008 Resolved
Renew vsl's link with proper size and type weak link.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 March 2008
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 30 January 2008 Resolved
Install water lights on both buoyant life floats.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 March 2008
Lifesaving › Lifebuoys › Serviceable
Issued 30 January 2008 Resolved
Renew retro-flective tape on both life ring buoys. Attach buoyant light with a corrosion resistant clip.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 March 2008
Documentation › Certificates/Documents › Certificate of Inspection
Issued 15 February 2006 Resolved
Vessel operated with passenger for hire outside of annual inspection dates.
Due 17 March 2006
Resolved 21 March 2006
Resolution: Issued Ticket
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 15 February 2006 Resolved
Vessel has exhaust leak on exhaust piping in E/R
Condition: Improper/Lack of Maintenance
Due 31 March 2006
Resolved 31 March 2006
Resolution: exhaust leak fixed
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 15 February 2006 Resolved
Vessel has exhaust leak on exhaust piping in E/R
Condition: Improper/Lack of Maintenance
Due 31 March 2006
Resolved 1 April 2006
Documentation › Markings/Placards › Lifejacket Placard
Issued 15 February 2006 Resolved
Needs to have donning placard for vest type life jacket
Condition: Improper/Lack of Maintenance
Due 31 March 2006
Resolved 15 February 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 February 2006 Resolved
Needs to secure wiring in overhead
Condition: Improper Installation
Due 31 March 2006
Resolved 31 March 2006
Resolution: Over head replaced
Documentation › Markings/Placards › Lifejacket Placard
Issued 15 February 2006 Resolved
Needs to stencil lifejacket locations.
Condition: Improper/Lack of Maintenance
Due 17 March 2006
Resolved 17 August 2007
Resolution: Completed
Communications › Alarms/Indicators › Bilge Alarm
Issued 15 February 2006 Resolved
High bilge alarm is not operating in aft lazerrette.
Condition: Improper Installation
Due 31 March 2006
Resolved 31 March 2006
Resolution: Replaced
Construction/Loadline › Hull › Bottom Plating
Issued 27 January 2005 Resolved
Cunduct hull gauging of entire hull bottom in the precense of CG Marine Inspector and conduct additional gauging in areas of concern as marked by the CG.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 1 February 2005
Construction/Loadline › Penetrations › Valve Flange
Issued 27 January 2005 Resolved
Make available for inspection the bilge overboard discharge and generator overboard discharge valves
Action required: 705 - Other - as specified
Resolved 1 February 2005
Personnel › Training › First Aid/CPR
Issued 25 October 2004 Resolved
Not one person in the crew had both a current first aid and cpr cards. The crew was told that 50% of them had to have both cards that were current.
Due 8 November 2004
Resolved 19 November 2004
Resolution: CPR/First-Aid cards provided
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 25 October 2004 Resolved
Did not provide preemployment drug test results for all crew members. No paperwork was available
Due 8 November 2004
Resolved 1 December 2004
Resolution: Faxed copy of drug consortium enrollment.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 25 October 2004 Resolved
Failed to provide a valid proof of enrollment for drug / alcohol program
Due 8 November 2004
Resolved 1 December 2004
Resolution: Vessel faxed copy of drug consortium records.
Personnel › Training › Watchkeeping
Issued 25 October 2004 Resolved
No records from the year 2004 for all drills and training was available
Due 19 November 2004
Resolved 19 November 2004
Resolution: Drill log provided
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 25 October 2004 Resolved
Expired Certificate of documentation
Due 8 November 2004
Resolved 19 November 2004
Resolution: Documentation provided
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 25 October 2004 Resolved
No valid FCC operations permit or marine radio operator permit present
Due 8 November 2004
Resolved 19 November 2004
Resolution: FCC records provided
Documentation › Markings/Placards › Warning Signs
Issued 25 October 2004 Resolved
Relocate the emerency Instruction topside in clear view of crew and passangers
Due 8 November 2004
Resolved 19 November 2004
Resolution: Emergency instruction posted near the operating station.
Stability › Watertight Integrity › General
Issued 25 October 2004 Resolved
Aft. Watertight door in engine compartment the lower hinge needs a nut for the lose bolt.
Due 8 November 2004
Resolved 19 November 2004
Resolution: Nut placed on hinge
Deck/Cargo › Mooring/Anchoring › Mooring Line/Hawser
Issued 25 October 2004 Resolved
#1 mooring line on bow needs to be replaced
Due 8 November 2004
Resolved 19 November 2004
Resolution: Mooring line replaced
Lifesaving › Lifefloat › Paddle
Issued 25 October 2004 Resolved
Paddles were not tied off to the lifefloat to prevent them from floating away
Due 19 November 2004
Resolved 19 November 2004
Resolution: Paddles attached to the life float
Lifesaving › Buoyant Apparatus › Readily Accessible
Issued 25 October 2004 Resolved
#2 life ring needs to mounted and made more readily accessable to crew and passangers
Due 8 November 2004
Resolved 19 November 2004
Resolution: Lifering made accessible to passengers.
Engineering › Diesel Engine (propulsion-direct drive) › Crosshead Assembly
Issued 25 October 2004 Resolved
This is actually the machinery guard on the front of the engine, which was missing a bolt on the lower port side. it was causing a lot of vibration and noise while the engine was running.
Due 8 November 2004
Resolved 19 November 2004
Resolution: Machinery guard properly secured.
Construction/Loadline › Penetrations › Bottom Plug Packing
Issued 25 October 2004 Resolved
Excessive dripping of water into the bilge was observed from the shaft packing. The drip was at a steady rate and needs to be adjusted.
Due 8 November 2004
Resolved 19 November 2004
Resolution: Shaft packing adjusted and dripping minimized
Pollution Prevention/Response › Prevention Equipment › Portable Containment
Issued 25 October 2004 Resolved
replace plastic garbage can with noncombustible one
Due 8 November 2004
Resolved 1 December 2004
Resolution: New metal can provided
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 25 October 2004 Resolved
Re-label Forward lifejacket storage compartment
Due 8 November 2004
Resolved 19 November 2004
Resolution: Lifejacket stowage restenciled
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 25 October 2004 Resolved
No man over board drill was conducted due to the captain not showing up.
Due 8 November 2004
Resolved 19 November 2004
Resolution: Satisfactory MOB drill conducted
Lifesaving › Buoyant Apparatus
Issued 27 October 2003 Resolved
Provide proper float-free arrangement for life floats.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 October 2003
Resolution: float free arrangement provided for the life floats
Lifesaving › Lifejacket/PFD (Type I)
Issued 27 October 2003 Resolved
Install lights on all life jackets LEGACY COMPONENT DESC: Lights
Due 21 November 2003
Resolved 19 April 2004
Resolution: All light satisfactory installed.
Lifesaving › Lifejacket/PFD (General)
Issued 27 October 2003 Resolved
Provide separate storage for child life jackets LEGACY COMPONENT DESC: Storage
Due 10 November 2003
Resolved 10 November 2003
Resolution: Alternate stowage provided for child lifejackets on the deck rails. 4-19-04: Constructed permanent stoage boxes on deck for C/L.
Lifesaving › Lifejacket/PFD (Type I)
Issued 27 October 2003 Resolved
Properly mark all lifejacket storage boxes LEGACY COMPONENT DESC: Storage
Due 10 November 2003
Resolved 31 October 2003
Resolution: boxes properly marked
Personnel › Manning/Qualifications
Issued 27 October 2003 Resolved
Show proof of CPR and first aid training LEGACY COMPONENT DESC: CPR Certified Personnel
Due 10 November 2003
Resolved 23 December 2003
Resolution: cpr cards provided
Personnel › Manning/Qualifications
Issued 27 October 2003 Resolved
Provide proof of random drug testing program. LEGACY COMPONENT DESC: Medical Fitness
Due 10 November 2003
Resolved 23 December 2003
Resolution: Random program testing papers provided
Communications › Alarms/Indicators
Issued 27 October 2003 Resolved
Bilge high water alarms inoperable LEGACY COMPONENT DESC: High Water Alarm
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 October 2003
Resolution: high water alarms installed
Engineering › Bilge Water Management System
Issued 27 October 2003 Resolved
Blank off piping going thru collision bulkhead LEGACY COMPONENT DESC: Piping
Due 10 November 2003
Resolved 23 December 2003
Resolution: Pipe blanked off
Personnel › Certificates/Documents/Licenses
Issued 27 October 2003 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 April 2004
Resolved 20 April 2004
Resolution: SNM issued LOW this date.
Construction/Loadline › Hull
Issued 11 February 2003 Resolved
Replace all zincs on vessel (deficiency issued as a worklist item).
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 March 2003
Resolved 21 February 2003
Construction/Loadline › Structures
Issued 11 February 2003 Resolved
Make permanent repairs to bow sprit (deficiency issued as a worklist item).
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 March 2003
Resolved 21 March 2003
Engineering › Diesel Engine (propulsion-electric)
Issued 11 February 2003 Resolved
Provide lagging on engine exhaust to prevent burn hazard (deficiency issued as a worklist item).
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 March 2003
Resolved 21 February 2003
Stability › Watertight Integrity
Issued 18 October 2002 Resolved
Provide properly securing watertight door (aft) and label both of vessels watertight doors "WATERTIGHT DOOR-KEEP CLOSED" on both sides of doors. LEGACY COMPONENT DESC: Door
Due 18 November 2002
Resolved 15 November 2002
Construction/Loadline › Structures
Issued 17 October 2002 Resolved
Due to vessel COI expiring, vessel now falls under New T and is required to raise height of rails from 36" to 39.5". LEGACY COMPONENT DESC: RAILS
Due 17 January 2003
Resolved 11 March 2003
Resolution: Vessel rails raised as reqired.
Lifesaving
Issued 17 October 2002 Resolved
EPIRB registration with NOAA expired in 2000. LEGACY COMPONENT DESC: EPIRB
Condition: Improper/Lack of Maintenance
Due 17 November 2002
Resolved 15 November 2002
Fire Fighting › Miscellaneous Items
Issued 17 October 2002 Resolved
Vessel needs three fire buckets as per 46 C.F.R 181.610 to meet the requirements of New T. LEGACY COMPONENT DESC: Fire Buckets
Due 27 October 2002
Resolved 18 October 2002
Lifesaving › Buoyant Apparatus
Issued 17 October 2002 Resolved
Vessel name not marked on the bouyant apparatus (2). LEGACY COMPONENT DESC: Markings
Condition: Improper/Lack of Maintenance
Due 27 October 2002
Resolved 18 October 2002
Navigation
Issued 19 March 2001 Resolved
Properly paint black background for port and starboard running lights.
Condition: Unknown
Due 4 April 2001
Resolved 4 April 2001
Lifesaving
Issued 19 March 2001 Resolved
Conduct satisfactory man overboard drill while underway.
Condition: Unknown
Due 4 April 2001
Resolved 4 April 2001
Electrical
Issued 5 November 1999 Resolved
Make emergenc lighting so as to remove local control. (do not allow abilityto secure light with local control)
Condition: Unknown
Due 5 November 1999
Resolved 5 November 1999
Documentation
Issued 5 November 1999 Resolved
Need new FCC certificate.
Condition: Unknown
Due 5 November 1999
Resolved 5 November 1999
Fire Fighting
Issued 5 November 1999 Resolved
Need additional B-II fire extingusher.
Condition: Unknown
Due 5 November 1999
Resolved 5 November 1999
Engineering
Issued 5 November 1999 Resolved
Install belt guard on MDE.
Condition: Unknown
Due 5 November 1999
Resolved 5 November 1999
Unknown
Issued 5 November 1999 Resolved
need renewal for crew members CPR certification.
Condition: Unknown
Due 5 November 1999
Resolved 5 November 1999
Construction/Loadline
Issued 5 November 1999 Resolved
Repair/Replace high level bilge alarm in engineroom
Condition: Unknown
Due 5 November 1999
Resolved 5 November 1999
Construction/Loadline
Issued 26 April 1999 Resolved
Install high level bilge alarms in all spaces with through-hull fittings below the waterline.
Condition: Unknown
Due 26 April 1999
Resolved 26 April 1999
Engineering
Issued 26 April 1999 Resolved
Double-band all water hoses connected to engine.
Condition: Unknown
Due 26 April 1999
Resolved 26 April 1999
Construction/Loadline
Issued 26 April 1999 Resolved
adjust all water-tight doors for correct fitting.
Condition: Unknown
Due 26 April 1999
Resolved 26 April 1999
Lifesaving
Issued 26 April 1999 Resolved
Mount EPIRB.
Condition: Unknown
Due 26 April 1999
Resolved 26 April 1999
Construction/Loadline
Issued 3 April 1998 Resolved
TIGHTEN/ADJUST DOGS ON AFT WATERTIGHT HATCH.
Condition: Unknown
Due 3 April 1998
Resolved 3 April 1998
Navigation
Issued 3 April 1998 Resolved
REPLACE MAST LIGHT BULB.
Condition: Unknown
Due 3 April 1998
Resolved 3 April 1998
Accommodation/Occupational Safety
Issued 3 April 1998 Resolved
PROPERLY MARK EMERGENCY EXITS.
Condition: Unknown
Due 3 April 1998
Resolved 3 April 1998
Electrical
Issued 3 April 1998 Resolved
PROVE PROPER OPERATION OF GENERATOR.
Condition: Unknown
Due 3 April 1998
Resolved 3 April 1998
Electrical
Issued 3 April 1998 Resolved
PROVIDE AUTOMATIC EMERGENCY LIGHTING FOR BELOW DECK LOUNGE AREA.
Condition: Unknown
Due 3 April 1998
Resolved 3 April 1998
Construction/Loadline
Issued 3 April 1998 Resolved
PROVIDE HOSE CLAMP TO DECK DRAIN LINE IN WAY OF THROUGH HULL FITTING IN E/R.
Condition: Unknown
Due 3 April 1998
Resolved 3 April 1998
Lifesaving
Issued 12 August 1997 Resolved
Provide one smoke signal in accordance with 46 CFR 180.68. Vessel restricted to Lakes, Bays and Sounds until in compliance.
Condition: Unknown
Due 21 August 1997
Resolved 21 August 1997
Lifesaving
Issued 12 August 1997 Resolved
Provide emergency broadcast instructions in accordance with 46 CFR 184.506.
Condition: Unknown
Due 21 August 1997
Resolved 21 August 1997
Fire Fighting
Issued 12 August 1997 Resolved
Service all fire extinguishing equipment.
Condition: Unknown
Due 21 August 1997
Resolved 21 August 1997
Documentation
Issued 12 August 1997 Resolved
Provide FCC operators license. Vessel restricted to 1000 feet from shore until in compliance.
Condition: Unknown
Due 18 August 1997
Resolved 18 August 1997
Lifesaving
Issued 12 August 1997 Resolved
Provide life preserver donning instructions in accordance with 46 CFR 185.516.
Condition: Unknown
Due 12 August 1997
Resolved 12 August 1997
Navigation
Issued 12 August 1997 Resolved
Renew one steering pulley, port side, forward.
Condition: Unknown
Due 12 August 1997
Resolved 12 August 1997
Lifesaving
Issued 12 August 1997 Resolved
Provide EPIRB in accordance with 46 CFR 180.64. Vessel restricted to Lakes, Bays and Sounds until in compliance.
Condition: Unknown
Due 12 August 1997
Resolved 12 August 1997
Lifesaving
Issued 12 August 1997 Resolved
Provide 60 feet of line for life ring buoy in accordance with 46 CFR 180.70.
Condition: Unknown
Due 12 August 1997
Resolved 12 August 1997
Lifesaving
Issued 12 August 1997 Resolved
Provide first aid kit in accordance with 46 CFR 184.710.
Condition: Unknown
Due 12 August 1997
Resolved 12 August 1997
Electrical
Issued 6 March 1997 Resolved
Properly dead end all electrical cables.
Condition: Unknown
Due 6 March 1997
Resolved 6 March 1997
Electrical
Issued 6 March 1997 Resolved
Renew all non-marine electrical cables with approved marine grade in accordance with Federal Register Vol.61, No.7 183.340. Call MSO Charlestonprior to enclosing bulkheads.
Condition: Unknown
Due 6 March 1997
Resolved 6 March 1997
Accommodation/Occupational Safety
Issued 6 March 1997 Resolved
Provide documentation of mattresses complying with Federal Register Vol.61,No.7 177.405(g).
Condition: Unknown
Due 6 March 1997
Resolved 6 March 1997
Documentation
Issued 18 April 1996 Resolved
PROVIDE PROOF OF COMPANY DRUG TESTING POLICY NO LATER THAN 25 APR 96.
Condition: Unknown
Due 25 April 1996
Resolved 10 May 1996
Deck/Cargo
Issued 18 April 1996 Resolved
REPLACE LOWER DOUBLE BLOCK ON FORWARD MAST MAINSHEAT.
Condition: Unknown
Due 18 April 1996
Resolved 18 April 1996
Construction/Loadline
Issued 18 April 1996 Resolved
REMOVE SOFT PVC PIPING FOR MSD DISCHARGE PIPING LOCATED BELOW WATERLINE ANDPLUG INTAKE.
Condition: Unknown
Due 18 April 1996
Resolved 18 April 1996
Lifesaving
Issued 18 April 1996 Resolved
PROVIDE ONE COAST GUARD APPROVED RING BUOY IAW 46 CFR 180.30 AND 46 CFR 180.10-30 PRIOR TO SAILING WITH 49 TOTAL PERSONS ON A COASTWISE VOYAGE, BUTNOT LATER THAN 24 MAY 96.
Condition: Unknown
Due 18 April 1996
Resolved 18 April 1996
Lifesaving
Issued 18 April 1996 Resolved
REMOVE ELECTRICAL FAN FROM VENT DUCTING IN ENGINE SPACE IAW 46 CFR 182.460(c).
Condition: Unknown
Due 18 April 1996
Resolved 18 April 1996
Lifesaving
Issued 18 April 1996 Resolved
REFASTEN VENT DUCT IN ENGINE ROOM THAT PASSES INTO BILGE.
Condition: Unknown
Due 18 April 1996
Resolved 18 April 1996
Fire Fighting
Issued 18 April 1996 Resolved
SERVICE ALL PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 18 May 1996
Resolved 10 May 1996
Lifesaving
Issued 18 April 1996 Resolved
PROVIDE SIX RED HAND FLARES IAW 46 CFR 180.68. VESSEL RESTRICTED TO DAYLIGHT OPERATION UNTIL PROVIDED.
Condition: Unknown
Due 14 May 1996
Resolved 14 May 1996
Lifesaving
Issued 18 April 1996 Resolved
PROVIDE WATER PROOF FLARE BOX WITH THE WORDS "DISTRESS SIGNALS" IAW 46CFR180.68
Condition: Unknown
Due 18 April 1996
Resolved 18 April 1996
Engineering
Issued 18 April 1996 Resolved
REROUTE WATER HOSE FOR WET EXHAUST FEED TO PREVENT THE HOSE FROM RUBBING.
Condition: Unknown
Due 18 April 1996
Resolved 18 April 1996
Lifesaving
Issued 18 April 1996 Resolved
PROVIDE WATER LIGHT FOR LIFE FLOAT IAW 46 CFR 180.175(e)(4)
Condition: Unknown
Due 18 April 1996
Resolved 18 April 1996
Navigation
Issued 18 April 1996 Resolved
REPAIR AND PROVE OPERATION OF PRIMARY STEERING PRIOR TO SAILING WITH PASSENGERS, BUT NO LATER THAN 30 DAYS.
Condition: Unknown
Due 14 May 1996
Resolved 14 May 1996
Deck/Cargo
Issued 18 April 1996 Resolved
LOCK ALL TURNBUCKLES TO PREVENT TWISTING.
Condition: Unknown
Due 18 April 1996
Resolved 18 April 1996
Accommodation/Occupational Safety
Issued 8 December 1995 Resolved
PROVIDE ALL PLANS AND INFORMATION FOR MODIFICATION OF MSD TANK. PLANS ARE TO BE SUBMITTED NO LATER THAN 08JAN96. WORK FOR MODIFICATION IS TO BE COMPLETED NO LATER THAN 08FEB96. USE OF TEMP. TANK IS AUTHORIZED. MASTER IS TO EXAMINE TANK PRIOR AND AFTER EACH CHARTER. EMPTY IF NECCESSARY.
Condition: Unknown
Due 8 December 1995
Resolved 8 December 1995
Fire Fighting
Issued 4 April 1995 Resolved
PERMANENTLY MOUNT B-II FIRE EXTINGUISHER LOCATED IN AFT CABIN/GALLEY.
Condition: Unknown
Due 4 April 1995
Resolved 4 April 1995
Fire Fighting
Issued 4 April 1995 Resolved
WEIGH AND RECORD WEIGHT OF HALON CYLINDER IN ENGINE ROOM, IF LESS THAN 90% OF ORIGINAL HAVE UNIT SERVICED.
Condition: Unknown
Due 4 April 1995
Resolved 4 April 1995
Electrical
Issued 4 April 1995 Resolved
PROVIDE A BOX FOR 12 VOLT BATTERY UNDER ENGINE ROOM DECK PLATE.
Condition: Unknown
Due 4 April 1995
Resolved 4 April 1995
Engineering
Issued 4 April 1995 Resolved
RENEW RAW WATER SUCTION HOSE BEFORE R/W PUMP ON MAIN ENGINE.
Condition: Unknown
Due 4 April 1995
Resolved 4 April 1995
Engineering
Issued 27 July 1994 Resolved
Make LPG hose available for 100% inspection.
Condition: Unknown
Due 5 August 1994
Resolved 3 March 1995
Lifesaving
Issued 27 July 1994 Resolved
Conduct Man-Overboard drill and fire drill.
Condition: Unknown
Due 5 August 1994
Resolved 3 March 1995
Lifesaving
Issued 27 July 1994 Resolved
Put vessel name on ring bouy
Condition: Unknown
Due 5 August 1994
Resolved 3 March 1995
Engineering
Issued 27 July 1994 Resolved
Renew sign for fuel shut-off handles.
Condition: Unknown
Due 5 August 1994
Resolved 3 March 1995
Lifesaving
Issued 27 July 1994 Resolved
Provide cable or line on open bow rail section near pulpit at the 36" level
Condition: Unknown
Due 5 August 1994
Resolved 3 March 1995
Engineering
Issued 16 August 1993 Resolved
REPAIR PORT REMOTE FUEL SHUTDOWN AND PROVE PROPER OPERATION TO USCG MARINE INSPECTOR.
Condition: Unknown
Due 16 August 1993
Resolved 16 August 1993
Lifesaving
Issued 16 August 1993 Resolved
PROVIDE SIX (6) HAND HELD ORANGE SMOKE DISTRESS SIGNALS.
Condition: Unknown
Due 16 August 1993
Resolved 16 August 1993
Construction/Loadline
Issued 18 December 1991 Resolved
RECONNECT BILGE LINE TO FOREPEAK._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 26 March 1992
Resolved 26 March 1992
Navigation
Issued 18 July 1991 Resolved
VESSEL IS RESTRICTED TO 20 MILES FROM A HARBOR OF SAFE REFUGE UNTIL SIDEBAND RADIO IS MADE OPERABLE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 18 July 1991
Resolved 18 July 1991
Accommodation/Occupational Safety
Issued 18 July 1991 Resolved
PROPERLY SECURE AFTER COMPANIONWAY LADDER.
Condition: Unknown
Due 2 December 1991
Resolved 2 December 1991
Engineering
Issued 1 September 1990 Resolved
PERMANANTLY MOUNT NEW ENGINE CONTROL PANEL TO THE SATISFACTION OF THE ATTENDING USCG MARINE INSPECTOR.
Condition: Unknown
Due 1 September 1990
Resolved 1 September 1990
Lifesaving
Issued 28 December 1989 Resolved
VESSEL CAN NOT CARRY CHILDREN ON AN OCEANS OR INTERNATIONAL ROUTE UNTIL LIGHTS ARE PROVIDED FOR CHILD SIZE LIFE PRESERVERS.
Condition: Unknown
Due 28 December 1989
Resolved 28 December 1989
Construction/Loadline
Issued 8 August 1989 Resolved
ENGINE ROOM SKYLIGHT NOT WATERTIGHT.
Condition: Unknown
Due 8 August 1989
Resolved 8 August 1989
Lifesaving
Issued 8 August 1989 Resolved
STOWAGE OF CHILDRENS PFD'S NOT EASILY IDENTIFIABLE.
Condition: Unknown
Due 8 August 1989
Resolved 8 August 1989
Accommodation/Occupational Safety
Issued 8 August 1989 Resolved
REFRIGERATION COMPRESSOR NOT PERMANENTLY MOUNTED.
Condition: Unknown
Due 8 August 1989
Resolved 8 August 1989
Electrical
Issued 8 August 1989 Resolved
WATER PUMP ON A/C GENERATOR LEAKING.
Condition: Unknown
Due 8 August 1989
Resolved 8 August 1989
Documentation
Issued 4 August 1988 Resolved
RE-SUBMIT STABILITY CALCULATIONS IN ACCORDANCE WITH FORMAT PRESCRIBED IN NVIC 15-81 PRIOR TO 01DEC88
Condition: Unknown
Due 4 August 1988
Resolved 4 August 1988

Casualty record · 2

12 July 2008Routine · role: Involved in a Marine Casualty · activity 3267556
15 August 2019Routine · role: Involved in a Marine Casualty · activity 6785520
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.