MAURY USCG vessel records
← All vessels

COOL CHANGE 2

COOL CHANGE 2 is a 1988 passenger vessel (inspected). The Coast Guard has recorded 23 inspections since 2016, most recently in April 2026, along with 24 deficiencies and 1 casualty investigation in 2020.

Records from 2016 to 2026. Most recent: inspection, 29 April 2026.

Built
1988
Last inspected
29 April 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the recorded names, the casualty record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 29 April 2026
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDP4228
308011
Flag
UNITED STATES
Maury page id
psix-308011

Documentation record

Registered dimensions (L × B × D)44.0 ft × 14.8 ft × 7.0 ft
Registered tonnagegross 30 / net 24
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderHENRIQUES BOAT WORKS, INC. · BAYVILLE, NJ, UNITED STATES · built 1988
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portORANGE BEACH, AL
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 15 December 2025 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it30 - Simplified, Gross Ton
24 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

23 inspections, each with its date, unit and type; 24 deficiencies with the resolution recorded against each; 1 other recorded name, with years; 1 casualty investigation, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 23

29 April 2026 Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8357528
27 February 2026 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8320638
15 May 2025 Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8118002
7 February 2024 Drydock Exam · Administrative Inspection · Deficiency Check · COI Inspection · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7862347
4 December 2023 Administrative Inspection
Administrative · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 7833376
27 November 2023 Administrative Inspection
Administrative · USCG Northeast District (dp) · USCG Northeast District (CGD-NE) · Activity 7829755
5 October 2023 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 7804149
13 September 2023 Administrative Inspection
Administrative · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 7790695
10 August 2022 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 7533150
9 May 2022 Drydock Exam · Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 7448398
18 May 2021 Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 7184034
30 August 2020 Type not recorded
No type recorded · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 7047038
6 August 2020 Annual Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 7026591
13 May 2020 Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 6952709
20 May 2019 Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 6688328
5 March 2019 Type not recorded
No type recorded · Station Portsmouth Harbor · USCG Northeast District (CGD-NE) · Activity 6636824
10 December 2018 Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 6595199
10 May 2018 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 6411162
28 April 2018 Type not recorded
No type recorded · Station Portsmouth Harbor · USCG Northeast District (CGD-NE) · Activity 6401388
21 June 2017 In-Service Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 6182617
12 May 2017 DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 6144823
12 December 2016 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 6056512
3 May 2016 COI Inspection · Deficiency Check · DAPI Audit
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 5867878

Deficiency record · 24

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 21 May 2024 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for protection against fire. Marine inspector observed a fuel leak under the shipboard generator. Secure leak and ensure residual fuel is cleaned up.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 May 2024
Resolution: Vessel Rep cordinated with mechanic to secure fuel leak on generator. Marine inspector verified on site ALL SAT.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 21 May 2024 Resolved
Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10 (incorporated by reference, see § 175.600 of this chapter). Marine inspector observed the portable fire extinguisher at the operating station to be in need of recharge.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 May 2024
Resolution: Vessel Rep replaced under pressured fire extinguisher with a new extinguisher. Marine inspector verified on site ALL SAT.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 February 2024 Resolved
Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Marine inspector observed exposed wires in: aft port engine room on bulkhead and under helm at the operating station. Properly enclose wiring to reduce hazards.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2024
Resolved 24 May 2024
Resolution: Vessel Rep covered exposed wiring with approved means, the aft engineroom wiring was encased in a junction box and the wiring under the operation station was removed. Marine inspector verified on site ALL SAT.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 10 October 2023 Resolved
For fixed gas fire extinguishing systems the inspections and tests required by 176.810(b) of this section. Pre engineered system has not been serviced.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 December 2023
Resolution: Pre engineered system was serviced.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 10 October 2023 Resolved
At each inspection for certification, and at every other vessel inspection, all observed unsafe practices, fire hazards, and other hazardous situations must be corrected. Portside engine has excessive exhaust that enters accommodation and leaves sheen upon the water.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 November 2023
Resolved 21 December 2023
Resolution: Port engine had head and valve work completed to attempt to remedy smoke. This should continue to be monitored.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 10 October 2023 Resolved
Vessels described by 46 CFR 175.110 (c) must have an interconnected fire detection system in compliance with 181.450. Vessel has an oceans route and does not have interconnected fire detection system.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 November 2023
Resolved 21 December 2023
Resolution: Vessel owner installed commercial off the shelf interconnected smoke detection system.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 October 2023 Resolved
Electrical equipment in the following locations must be drip proof; a location normally exposed to splashing, water wash down or other wet conditions. Anchor windless electrical enclosure does not have a cover there are also dead ended wires.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 November 2023
Resolved 21 December 2023
Resolution: Enclosure cover added.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 10 October 2023 Resolved
Vessel requires a first aid kit. First aid kit is expired.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 November 2023
Resolved 21 December 2023
Resolution: New first aid kit onboard.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 13 September 2023 Resolved
Annual inspection. Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel did not complete annual inspection. Complete annual inspection prior to carrying passengers for hire.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 October 2023
Resolution: Annual inspection completed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 August 2022 Resolved
An adult life jacket must be provided for each person carried on board a vessel; 01 kapok style life jacket was removed from service. Passenger count reduced by 01 adult.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 August 2022
Resolved 26 August 2022
Resolution: PFD was replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 10 August 2022 Resolved
At each inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected. Bilge pump on port engine was swinging loose.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 August 2022
Resolved 26 August 2022
Resolution: Bilge pump secured and belt replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 August 2022 Resolved
At each inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected. Generator windings were found fouled with oil and foreign matter. Cleaning to be conducted per manufacturers recommended process.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 August 2022
Resolved 26 August 2022
Resolution: Vessel was attended by 3rd party contractor. Generator observed, ran and tested sat. Cleaning not required per contractor.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 August 2022 Resolved
Exhaust piping shall be gas tight throughout its length. Water was observed dripping from the exhaust of the starboard engine in way of the transition from metal to the non metallic portion of the exhaust.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 September 2022
Resolved 26 August 2022
Resolution: New exhaust elbow fabricated and installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 18 May 2021 Resolved
A voltmeter and an ammeter shall be provided that can be used for measuring voltage and current of each generator that is in operation. For alternating-current generators a means for measuring frequency shall also be provided. SEAFARI currently is not fitted with means to measure these operating parameters. Install required meters. 46 CFR 183.10-5(g)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2021
Resolved 3 June 2021
Resolution: Installed required meter.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 5 June 2019 Resolved
Radio Safety Certificate expired
Due 28 June 2019
Resolved 14 June 2019
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 5 June 2019 Resolved
Float light batteries expired
Due 14 June 2019
Resolved 5 June 2019
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 5 June 2019 Resolved
High bilge alarms inoperative
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 June 2019
Resolved 5 June 2019
Navigation › Piloting/Steering › Marine Charts
Issued 16 May 2017 Resolved
Provide current charts
Due 2 June 2017
Resolved 17 May 2017
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 16 May 2017 Resolved
Provide current proof
Due 2 June 2017
Resolved 17 May 2017
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 16 May 2017 Resolved
Provide ammonia inhalants
Due 2 June 2017
Resolved 17 May 2017
Communications › Radio Communications › VHF Radiotelephone
Issued 6 May 2016 Resolved
VHF radio with DSC not connected to GPS
Due 20 May 2016
Resolved 25 May 2016
Fire Fighting › Fire Bucket › Quantity
Issued 6 May 2016 Resolved
Provide correct size and number of Fire Buckets.
Due 20 May 2016
Resolved 11 May 2016
Navigation › Piloting/Steering › Marine Charts
Issued 6 May 2016 Resolved
Provide current charts for area
Due 20 May 2016
Resolved 11 May 2016
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 6 May 2016 Resolved
Provide new, correct batteries for float lights.
Due 20 May 2016
Resolved 11 May 2016

Casualty record · 1

30 August 2020Routine · role: Subject of Search and Rescue · serious marine incident, as classified · 1 dead · activity 7047038
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

SEAFARI (2020). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.