Passenger (Inspected) · Passenger Ship class · Built 1980s · USCG Southeast District (CGD-SE) · Other hulls named CAN TANK EROUS
CAN TANK EROUS is a 1988 passenger vessel (inspected). The Coast Guard has recorded 60 inspections since 1988, most recently in January 2025, along with 122 deficiencies, 1 operational control and 1 casualty investigation in 2013.
Records from 1988 to 2025. Most recent: inspection, 23 January 2025.
- Built
- 1988
- Last inspected
- 23 January 2025
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 122 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2013
Identity
932782
WDJ4781
308207
Flag
UNITED STATES
367781050
Maury page id
psix-308207
Inspections, by type
…with no type recorded5
Years with a record
35 calendar years (1988–2025)
The 60 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)29.0 ft × 12.0 ft × 5.0 ft
Registered tonnagegross 11 / net 9
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderISLAND HOPPER INC · MARATHON SHORES, FL, UNITED STATES · built 1988
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portCLEARWATER, FL
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 30 July 2025 · expires 31 August 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it11 - Simplified, Gross Ton
9 - Simplified, Net Ton
9 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDJ4781MMSI 367781050 · active · compulsorily equipped · granted 6 April 2017, expires 6 April 2027
WDD6103MMSI 367168330 · expired · compulsorily equipped · granted 23 February 2007, cancelled 29 April 2017
WBC3741MMSI not assigned · expired · compulsorily equipped · granted 2 December 1996, cancelled 20 January 2007 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 60
23 January 2025
Deficiency Check · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8049654
15 January 2025
Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8049648
31 May 2024
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7924165
26 June 2023
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7721117
20 January 2023
Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7602871
3 March 2022
Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7420793
9 February 2021
Plan Review "T" Boat · Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7137836
20 January 2021
Internal Structural Exam · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7127964
10 May 2020
Deficiency Check · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6956212
14 February 2020
COI Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6895769
26 February 2019
Administrative Inspection · Drydock Exam · Annual Inspection · DAPI Audit · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6625483
7 May 2018
Administrative Inspection · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6403325
1 May 2017
Annual Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6132886
16 March 2017
Deficiency Check · Hull Examination · Internal Structural Exam · Examination of Repairs · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6106037
23 February 2016
DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5820905
17 February 2012
Deficiency Check · COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4246613
27 January 2012
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4233151
19 August 2011
Deficiency Check · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4129617
8 February 2011
Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3942197
16 March 2010
Annual Inspection · DAPI Audit · Administrative Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3696033
10 February 2009
Administrative Inspection · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3427461
4 March 2008
Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3157673
16 February 2007
Hull Examination · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2872537
27 February 2006
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2592750
25 February 2005
Hull Examination · Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2299075
4 March 2004
Annual Inspection · Administrative Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2013042
18 February 2003
Hull Examination · Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1739414
1 March 2002
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1489389
1 May 2001
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1062211
2 April 2001
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1452781
7 March 2001
Plan Review "T" Boat
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1060455
23 February 2001
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1060108
9 January 2001
MARPOL Annex V Examination · Re-Inspection · Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1421996
3 March 2000
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1415322
29 February 2000
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1417033
2 March 1999
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 803287
7 January 1999
MARPOL Annex V Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1427613
15 September 1998
Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1464802
11 February 1998
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 783801
7 August 1997
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 783515
17 July 1997
COI Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1115585
12 September 1996
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1092865
30 January 1996
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 874656
8 September 1995
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 874169
8 September 1994
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1176876
18 July 1994
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 868099
26 January 1994
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1163058
5 January 1994
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 687670
23 November 1993
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 664466
12 November 1993
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1140600
8 October 1993
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 138106
8 October 1993
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 835791
28 January 1992
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 949770
30 December 1991
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 162516
8 August 1991
Deficiency Check · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1245744
12 September 1990
Re-Inspection · Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 910812
1 August 1990
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1242904
16 November 1989
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 912031
1 September 1988
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1040680
10 August 1988
Initial Certification · Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1043021
Deficiency record · 122
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 January 2025
Resolved
Where flexible nonmetallic hose is permitted for use in piping systems by this section, it must meet SAE J-1942. Flexible nonmetallic hose may be used in lube oil and fuel oil systems, for the purpose of flexibility only, flexible hose installed in lengths of not more than 760 millimeters (30 inches). Hose end fittings must comply with SAE J-1475. MI observed two fuel lines with fittings that were not the type required by this regulation, and were of a length over 30 inches.
46 CFR 182.720(e)(1)
02 - Structural Conditions › N/A - No Subsystem › Permanent means of access
Issued 23 January 2025
Resolved
At each initial and subsequent inspection for certification the owner or managing operator shall be prepared to test and make available for inspection all items in the ship's outfit which are required to be carried by the regulations in this subchapter, as necessary to determine that they are fit for the service intended. MI observed that the dive ladder on the vessel was wasted through in one section.
46 CFR 176.816
16c
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 23 January 2025
Resolved
Except as otherwise allowed by this subpart, a vessel must comply with the structural design requirements for fiber reinforced plastic vessels. MI observed area of
fiberglass damage on aft dive platform.
46 CFR 177.300(c)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 January 2025
Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operation. MI observed that the remote fuel shut off valves markings were not visible in the normal operating condition for the vessel.
46 CFR 185.608
16c
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 January 2025
Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in normally unmanned spaces. MI observed that the high level visual alarms at the operating station did not indicate which bilge pump is operating.
46 CFR 182.530(a)
16c
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 23 January 2025
Resolved
The owner or managing operator of a vessel shall ensure that the vessel complies with the laws and regulations applicable to the vessel and that the vessel is otherwise satisfactory for the intended service. The initial inspection may include an inspection of the following items: Certificates and operating manuals. MI observed that the NOAA Beacon registration form for the vessel's EPIRB had expired.
46 CFR 176.402(c)(3)
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 June 2024
Resolved
An adult life jacket must be provided for each person carried on board a vessel. MI observed two missing lifejackets. Capacity is limited to 22 persons onboard until lifejackets are replaced and verified by the CG.
46 CFR 180.71(a)
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 31 May 2024
Resolved
Vessel must undergo an annual inspection as specified in paragraph (b)(1) of this section. Vessel must undergo an annual inspection within 3 months before or after each anniversary date. Vessels anniversary date was 14FEB202024, and vessel is past 3 months from said date.
Vessel shall not operate with passengers until an annual inspection has been completed.
46CFR176.500(b) - 701C
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 3 July 2023
Resolved
Any vessel of at least five net tons which engages in fisheries on the navigable water of the United States or in the EEZ or coastwise trade must have a certificate of documentation.
Vessel did not have COD onboard.
46 CFR 67.7
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 July 2023
Resolved
The minimum number of portable fire extinguishers required on each vessel shall be as determined by the Officer in charge, marine inspections, in accordance with Table 181.30-1(a) and other provisions of this sub part.
Fire extinguisher located at operating station was not charged.
46 CFR 181.30-1(a)
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 3 July 2023
Resolved
Except as otherwise provided in this section, all vessels shall carry pyrotechnic distress signals as follows: 6 hand red flares distress signals, and 6 hand orange smoke distress signals; or, 12 hand combination flare and smoke distress signals.
Vessel had 6 hand orange smoke distress signals, and 4 hand red flare distress signals.
46 CFR 180.68(a)
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 3 July 2023
Resolved
Each inflatable liferaft, inflatable buoyant apparatus, life float, and buoyant apparatus on the vessel on March 11, 1996, may be used to meet the requirements of this part for these survival craft as long as the survival craft is continued in use on the vessel, and is in good and serviceable condition.
Life float was deteriorated and not serviceable for it's intended route.
**Vessel reduced to Lakes, Bays & Sounds route.**
46 CFR 180.15(d)
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 3 July 2023
Resolved
The master of the vessel shall ensure that: (a) Each EPIRB, other than an EPIRB in an inflatable liferaft, must be tested monthly, using the integrated test circuit and output indicator, to determine that it is operative; (b) The EPIRB's battery is replaced after it is used, or before the date required by FCC regulations in 47 CFR part 80, whichever comes sooner; and (c) The EPIRB test required by paragraph (a) shall be logged or otherwise documented, as applicable.
EPIRB battery expired in February 2023, but EPIRB checks were completed for March, April, May and June of 2023
**Vessel is reduced to Lakes, Bays & Sounds route.**
46 CFR 185.728
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 3 July 2023
Resolved
The master and crew of a vessel will be familiar with
the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions.
Vessel did not have emergency instructions posted onboard.
46 CFR 185.510(a)
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 3 July 2023
Resolved
If fire is in machinery spaces, shut off fuel supply and ventilation and activate fixed extinguishing system if installed.
A vessel on which a pre-engineered fixed gas fire extinguishing system is installed must have the following equipment at the operating station: A means to reset devices used to automatically shut down ventilation systems and engines.
Captain did not know how to activate fixed system or how to reset/override engine at the operating station.
46 CFR 185.512(a)(3)(iv)
46 CFR 181.420(b)(3)
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 3 July 2023
Resolved
For fixed-gas fire extinguishing systems, the inspections and tests required by Table 176.810(b) of this section, in addition to the tests required by 46 CFR 147.60 and 147.65. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector.
Vessel did not have annual servicing reports for the installed fixed fire suppression system.
Provide report.
46 CFR 176.810(b)(2)
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 July 2023
Resolved
This part is intended to provide a minimum standard of regulations for electrical installations and equipment that will result in a vessel that is reasonably safe from fire caused by and/or originating in electrical equipment, and reasonably safe from electrical shock of personnel.
Discovered dead end wire under the main operating station.
46 CFR 183.01-5(a)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 July 2023
Resolved
It is further intended that all machinery be installed and maintained in such a manner as to afford adequate protection against fire, explosion, machinery failure and personnel injury.
Discovered excessive shaft seal leak while the vessel was moored and underway.
46 CFR 182.01-5(a)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 July 2023
Resolved
It is further intended that all machinery be installed and maintained in such a manner as to afford adequate protection against fire, explosion, machinery failure and personnel injury.
Discovered exhaust leak on the main diesel engine.
46 CFR 182.01-5(a)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 July 2023
Resolved
Flexible hose designed for use with hose clamps may be installed with two clamps, at both ends of the hose.
Fuel filter hose for the main diesel engine was not double clamped.
46 CFR 182.720(e)(v)(B)
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 3 July 2023
Resolved
A marine employer whose vessel is involved in a casualty or incident that is, or is likely to become, a serious marine incident as defined in § 4.03–2 of subchapter A of this chapter shall comply with the requirements of § 4.06 in subchapter A of this chapter...The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI.
Vessel did not have alcohol test strips onboard.
46 CFR 185.212
46 CFR 4.06-15(a)(1)
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 3 July 2023
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions...Each first-aid kit must meet the requirements in ISO 18813:2006(E) paragraph 4.12 (incorporated by reference, see § 199.05). (i) A first-aid kit may be considered acceptable if it meets all of the requirements of ISO 18813:2006(E) paragraph 4.12, except that it does not contain the burn preparations. It must be clearly marked on the first-aid kit that it does not include the burn preparations.
Vessel's analgesic medications were expired.
46 CFR 184.710
46 CFR 199.175(b)(10)
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 26 June 2023
Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date.
The vessel has a COI anniversary date of 14FEB. The vessel was required to have an annual inspection no later than 14MAY23, and the vessel has not had an annual inspection for this year.
46 CFR 176.500(b)(1)
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 3 March 2022
Resolved
Any vessel of at least five net tons which engages in the fisheries on the navigable waters of the United States or in the Exclusive Economic Zone, or coastwise trade, unless exempt under § 67.9(c), must have a Certificate of Documentation bearing a valid endorsement appropriate for the activity in which engaged.
The original COD was not found onboard.
46 CFR 67.7
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 3 March 2022
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: Charts of large enough scale to make safe navigation possible.
No navigation charts were found onboard.
46 CFR 184.420
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 3 March 2022
Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve.
The life float was color was found deteriorated and does not meet the Q specification for color.
46 CFR 180.175
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 March 2022
Resolved
Each portable fire extinguisher on a vessel must be of an approved type. The minimum number of portable fire extinguishers required on a vessel must be acceptable to the cognizant Officer in Charge, Marine Inspection, but must not be fewer than the minimum number required by Table 181.500(b) and other provisions of this section.
One 40 BC portable fire extinguisher was found without a charge.
46 CFR 181.500
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 3 March 2022
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. When repairs are made during an emergency, the owner, managing operator, or master shall notify the OCMI as soon as practicable after such repairs or alternations are made. Repairs or alterations that affect the safety of the vessel include, but are not limited to: replacement, repair, or refastening of deck or hull planking, plating, and structural members; repair of plate or frame cracks; damage repair or replacement, other than replacement in kind, of electrical wiring, fuel lines, tanks, boilers and other pressure vessels, and steering, propulsion and power supply systems; alterations affecting stability; and repair or alteration of lifesaving, fire detecting, or fire extinguishing equipment.
Identified the steering packing leaking during an operational test of the steering gear.
46 CFR 176.700
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 3 March 2022
Resolved
A hatch exposed to the weather must be watertight.
MI found the flush deck hatch to the laz space is leaking water and is not watertight.
46 CFR 171.124
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 March 2022
Resolved
Fuses must be of the cartridge type only and be listed by Underwriters Laboratories or another independent laboratory recognized by the Commandant.
The conductors for the battery charger are missing overcurrent protection.
46 CFR 183.380
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 23 March 2021
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must be made without the approval of the cognizant OCMI, except during an emergency. The owner or managing operator shall submit drawings, sketches, or details of any proposed alterations to the cognizant [name withheld] alterations must be approved by the OCMI before work is started.
Vessel was found to be outfitted with electric submersible bilge pumps that were installed with no submission of drawings or proposal to local OCMI for approval/acceptance. MI reviewed local vessel file and found no documentation for the approval/installation of new system. Vessel also has an installed bilge system piping and valves that appears to be from initial construction of the vessel and is not being used after.
Vessel owner has the option of meeting regulatory compliance for installed electric submersible bilge pumps with the submission and approval of electrical plans/diagrams to the Marine Safety Center or prove proper operation of the original bilge system that was installed at initial construction.
46 CFR 176.700
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 March 2021
Resolved
A submersible electric bilge pump may be used as a power bilge pump required by Table 182.520(a) only on a vessel of not more than 19.8 meters (65 feet) in length carrying not more than 49 passengers provided that:
A positive shutoff valve is installed at the hull penetration.
The bilge system does not have positive shutoff valves installed at the hull penetrations for each individual bilge line going overboard.
Install positive shutoff valves for each overboard bilge discharge line.
46 CFR 182.520(e)(7)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 February 2021
Resolved
Remote fuel shutoff stations shall be marked in at least 1 inch letters indicating purpose of the valve and direction of operation.
Markings were not of appropriate height and contained no directional information.
46 CFR 185.30-20
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 22 February 2021
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant [name withheld] rails located on the stern of vessel had severe corrosion and holes where they mount to vessel.
Provide plan proposal for repair or replacement.
46 CFR 176.700
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 22 February 2021
Resolved
A hatch exposed to the weather must be watertight.
MI found drain in aft hatch to have no piping and no indication of where the drain led. With current configuration any water taken on during normal operations would fill aft steering compartment creating potential flooding.
46 CFR 179.360(a)
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 February 2021
Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers.
MI found two different types of life jackets on board. Both types of donning instructions are required to be on board the vessel.
46 CFR 185.516(a)
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 22 February 2021
Resolved
Each vessel must be equipped with at least two operable portable battery lights.
Vessel had 01 operable portable light.
46 CFR 183.430
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 22 February 2021
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions.
Vessel had expired aspirin within first-aid kit.
46 CFRR 184.710
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 February 2021
Resolved
At least one ring life buoy must be fitting with a lifeline of at least 18.2 meters (60 feet) in length.
MI found lifeline to be approximately 30 feet.
46 CFR 180.70(c)(2)
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 February 2021
Resolved
A vessel not required to have a power driven fire pump must have at least three 9.5 liter (2.5 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed do as to be easily available during an emergency.
The words "FIRE BUCKET" must be stenciled in a contrasting color on each bucket.
Vessel had 02 fire buckets.
46 CFR 181.610
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 22 February 2021
Resolved
Each vessel that operates on the high seas...must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate.
EPIRB was found to be expired and did not match NOAA registration.
46 CFR 180.64
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 May 2020
Resolved
On 10MAY20 while underway, approximately 7 miles from Clearwater Pass, the vessel experienced a loss of propulsion. The vessel subsequently replaced the fuel filter an dwas able to return to port under its own power. Prior to carrying passengers, conduct sea trials in the presence of an attending marine inspector.
46 CFR 176.840
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 14 February 2020
Resolved
Each boat that operates on the high seas must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. The metal, spring loaded plate inside the EPIRB housing that pushes the EPIRB out of the housing when the hydrostatic release is cut was broken and no longer serving it's intended purpose. Vessel is limited to Lakes, Bays and Sounds route. Repair/replace prior to operating on a limited coastwise route.
46 CFR 180.64
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 14 February 2020
Resolved
Each survival craft on a vessel must be in good working order and ready for immediate use before the vessel leaves port and at all times when the vessel is underway. The 12 person life float was no longer in serviceable condition. Vessel is limited to Lakes, Bays and Sounds route. Repair/replace prior to operating on a limited coastwise route.
46 CFR 185.700
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 14 February 2020
Resolved
The floating waterlight must be attached around the body of the life float or buoyant apparatus by a 10mm (3/8 inch) lanyard, resistant to deterioration from ultraviolet light, and at least 5.5 meters (18 feet) in length. The waterlight lanyard is well short of 18 feet.
46 CFR 180.175(f)(4)
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 14 February 2020
Resolved
If the life float or buoyant apparatus does not have a painter attachment fitting, a means for attaching the painter must be provided by a wire or line that encircles the body of the device. The painter is attached to the grab lines and not to the painter attachment fitting. Vessel is limited to Lakes, Bays and Sounds route. Repair/replace prior to operating on a limited coastwise route.
46 CFR 180.137(d)
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 14 February 2020
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. The forward all around white light is inoperable. Repair/replace prior to nighttime or low visibility operations.
46 CFR 183.420
05 - Radio Communications › N/A - No Subsystem › Radio log (diary)
Issued 14 February 2020
Resolved
The EPIRB test required by 46 CFR 185.728(a) shall be logged or otherwise documented, as applicable. There is no records of logging the monthly EPIRB test. MI witnessed test by operator during the inspection and vessel representative will now start a log.
46 CFR 185.728(c)
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 14 February 2020
Resolved
Rails or equivalent protection must be installed near the periphery of all decks of a vessel accessible to passengers or crew. One of the forward port hand rail stanchions is broken.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 February 2020
Resolved
A vessel not required to have a power driven fire pump must have at least three 2.5 gallon buckets with an attached lanyard satisfactory to the cognizant OCMI. The fire buckets on board were missing the lanyards and were 5 gallon buckets. Prior to getting underway the operator drilled holes half way up the buckets to ensure they did not fill all the way up and attached the lanyards.
46 CFR 181.610
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 14 February 2020
Resolved
A vessel on which a pre-engineered fixed gas fire extinguishing system is installed must have the following equipment at the operating station: a light to indicate discharge and an audible alarm that sounds upon discharge. The light a audible alarm were inoperable. MI witnessed sat. operational test of the system.
46 CFR 181.420(b)
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 February 2020
Resolved
All cable and wire must be installed with metal supports spaced not more than 24 inches apart, and in such a manner as to avoid chafing and other damage. The wiring below deck in the engine room and behind the main console was not properly secured.
46 CFR 183.340(b)(4)
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 14 February 2020
Resolved
Where a flexible fill pipe section is necessary, the metallic sections of the fill pipe must be joined by a conductor for protection against generation of a static charge when filling with fuel. Both port and starboard fuel tanks were missing a bonding wire on the fill line.
46 CFR 182.445(g)
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 1 May 2017
Resolved
Provide in service B-1 fire extinguisher for operating station iaw 46CFR181.30-1(a).
Fire Fighting › Remote Fuel Shutoff › General
Issued 1 May 2017
Resolved
Provide labels for fuel shutoffs iaw 46CFR182.30-20(a)
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 1 May 2017
Resolved
Provide label for life preserver stowage area iaw 46CFR185.30-10.
Documentation › Certificates/Documents › FCC SSL
Issued 24 March 2017
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Communications › Radio Communications › VHF Radiotelephone
Issued 24 March 2017
Resolved
Provide radio equipped with GPS and programmed with MMSI number for DSC iaw 46CFR184.502.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 16 March 2017
Resolved
Vessel is past DD inspection date of 17FEB17. The vessel is required to complete a DD inspection. 46 CFR 176.600
Construction/Loadline › Hull › Hull Plating
Issued 16 March 2017
Resolved
Repair 05 areas of FRP on hull/keel/splash rail, as identified, iaw 46CFR176.610(a).
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 23 February 2016
Resolved
Provide proof of a valid FCC Safety Radio Certificate, vessel is restricted to operating NMT 100 feet from shore. 47CFR80
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 17 February 2012
Resolved
Correct DAPI deficiencies as per Chemical Test Program Compliance Form and 46 CFR 16.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 17 February 2012
Resolved
Correct DAPI deficiencies as per Chemical Test Program Compliance Form 46 CFR 16.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 17 February 2012
Resolved
Correct DAPI deficiencies as per Chemical Test Program Compliance Form 46 CFR 16.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 17 February 2012
Resolved
Label emergency fuel shut-off with direction arrow as per 46 CFR 185.30-20.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Location
Issued 17 February 2012
Resolved
Provide portable fire extinguisher near operating station as per 46 CFR 181.500(a).
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 17 February 2012
Resolved
Provide battery for float light on ring buoy as per 46 CFR 199.70(a)(3).
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 17 February 2012
Resolved
Provide Light List, Tide Tables, Current Tables, and COLREGS as per 46 CFR 184.420.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 17 February 2012
Resolved
Provide Light List, Tide Tables, Current Tables, and COLREGS as per 46 CFR 184.420.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 17 February 2012
Resolved
Provide Light List, Tide Tables, Current Tables, and COLREGS as per 46 CFR 184.420.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 17 February 2012
Resolved
Provide required items for First Aid Kit as per 46 CFR 160.041.
Stability › Intact Stability (when using lifting gear) › General
Issued 27 January 2012
Resolved
Vessel must undergo a simplified stability test IAW 46 CFR 178.330 within 30 days of this date.
Engineering › Diesel Engine (propulsion-direct drive) › Block
Issued 19 July 2011
Resolved
Conduct sea trials of new engine installed July 2011 to the satisfaction of attending Marine Inspector IAW 46CFR176.700
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 16 March 2010
Resolved
Provide proof of valid alcohol strips.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 16 March 2010
Resolved
Replace retro-reflective tape on 01 lifejackets.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 16 March 2010
Resolved
Replace batteries on 02 water lights.
Lifesaving › Lifefloat › Lifeline
Issued 16 March 2010
Resolved
Replace grabline on life float.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 16 March 2010
Resolved
Replace line on self activating light for life float.
Communications › Radio Communications › EPIRB
Issued 16 March 2010
Resolved
Replace hydrostatic release for EPIRB.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 16 March 2010
Resolved
Separate adult and child lifejackets.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 16 March 2010
Resolved
Replace fasteners on starboard side bench.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 4 March 2008
Resolved
Prior to operation completed the annual service for fixed fire extinguishing system.
Communications › Radio Communications › EPIRB
Issued 4 March 2008
Resolved
Prior to operation replace EPIRB antenna.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 4 March 2008
Resolved
Provide First Aid Kit with an aluminum splint, eye wash solution, ammonia inhalants and burn treatment compound to the completed within 7 days.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 1 March 2007
Resolved
Correct ALL discrepant items on DAPI Compliant Audit form.
Navigation › Piloting/Steering
Issued 1 March 2002
Resolved
Repair anchor light. LEGACY COMPONENT DESC: Anchor lights
Lifesaving › Lifejacket/PFD (Type II)
Issued 1 March 2002
Resolved
Replace retro-reflective tape on ring life buoy and life preservers as needed.
Lifesaving › Rigid Liferafts › Painter
Issued 1 March 2002
Resolved
Replace tag lines on life float.
Navigation › Piloting/Steering
Issued 1 March 2002
Resolved
Provide sound producing device. LEGACY COMPONENT DESC: Sound producing device
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 1 March 2002
Resolved
Provide an audibile alarm for the FFFE system.
Fire Fighting › Fixed Fire Detection System
Issued 1 March 2002
Resolved
Provide a smoke detector for engine room. LEGACY COMPONENT DESC: Smoke Detection
Construction/Loadline
Issued 2 April 2001
Resolved
REPAIR DAMAGED FIBERGLASS ON STARBOARD SIDE AT WATERLINE NEAR BOW.
Construction/Loadline
Issued 2 April 2001
Resolved
REPLACE BROKEN SEA VALVE FOR HEAD (STARBOARD SIDE).
Construction/Loadline
Issued 2 April 2001
Resolved
MAKE ENGINE RAW WATER INTAKE AVAILABLE FOR INSPECTION.
Lifesaving
Issued 9 January 2001
Resolved
Remove excess oil from fuel tank/aft steering and machinery space.
Engineering
Issued 9 January 2001
Resolved
Repair fuel lines, valve @ rudder collar in aft steering. Rudder collar to be replaced @ same time.
Documentation
Issued 9 January 2001
Resolved
Provide FCC Safety Certificate by 31JAN01.
Electrical
Issued 9 January 2001
Resolved
Properly support all electrical wiring, getting wires out of bilges.
Lifesaving
Issued 3 March 2000
Resolved
Provide FCC Cat I 406 EPIRB, Float Free, and provide proper registration.
Lifesaving
Issued 3 March 2000
Resolved
Get u/w with marine inspector to conduct drills & test of all systems.
Lifesaving
Issued 3 March 2000
Resolved
Properly rig ring buoy w/60' of line & waterlight.
Fire Fighting
Issued 3 March 2000
Resolved
Provide CG Approved pre-engineered fixed fire system to meet requirements of 46 CFR 181.420.
Construction/Loadline
Issued 3 March 2000
Resolved
Repair all high water alarms and automatic bilge pump switch. Install highwater alarm in the forepeak compartment.
Lifesaving
Issued 7 January 1999
Resolved
Provide complete drug test program for review prior to above noted date. Crew test results for 1998 tests verified.
Engineering
Issued 7 August 1997
Resolved
The vessel is not to operate until the cause of the oil leak on the main engine can be determined and repaired._x001C_ _x001C_ _x001C_
Navigation
Issued 17 July 1997
Resolved
Vessel did not have the required rules of the road, light list, tide and current tables and coast pilot onboard._x001C_ _x001C_ _x001C_
Lifesaving
Issued 17 July 1997
Resolved
Both required life ring buoys were missing retro-reflective tape and the grab line had been removed._x001C_ _x001C_ _x001C_
Fire Fighting
Issued 17 July 1997
Resolved
One of the B-II fire extinguishers had an improper seal securing the safetypin._x001C_ _x001C_ _x001C_
Lifesaving
Issued 17 July 1997
Resolved
There was no emergency broadcast placard or life jacket donning placard posted as required._x001C_ _x001C_ _x001C_
Lifesaving
Issued 18 July 1994
Resolved
Replace ring buoy.
Engineering
Issued 8 October 1993
Resolved
Make repairs to fuel leak on the pressure side of the Cummins engine fuel pump. This shall be accomplished prior to operation of the vessel with passengers aboard. Repair means no leakage not a reduced flow.
Lifesaving
Issued 8 October 1993
Resolved
Make appropriate repairs to lifefloat net, webbing, lines and body as necessary to return it to full servicability.
Lifesaving
Issued 8 October 1993
Resolved
Stencil vessel name on lifefloat in 1 1/2" letters minimum.
Navigation
Issued 8 October 1993
Resolved
Replace all navigational lights as necessary. Vessel is restricted to daylight operation only until this requirment is met and in no case later that 08 Nov 93.
Documentation
Issued 8 October 1993
Resolved
Post stability letter aboard the vessel.
Documentation
Issued 8 October 1993
Resolved
Provide evidence of a completed Federal Communications Commision Safety examination of the installed VHF-FM radio.
Documentation
Issued 8 October 1993
Resolved
Provide evidence of a drug testing program meeting the requirements set forth in 46 CRF part 16.
Lifesaving
Issued 8 October 1993
Resolved
Lash two 4 foot paddles to the lifefloat.
Construction/Loadline
Issued 8 October 1993
Resolved
Remove all fuel from bilge and clean same so as to prevent additional discharge of oil into the navgable waters of the United States.
Electrical
Issued 8 October 1993
Resolved
Place emergency lights on board the vessel. Vessel is restricted to daylight operation until lights are aboard and in no case later_x001C_ than 08 Nov 93.
Lifesaving
Issued 8 October 1993
Resolved
Make necessary repairs to all waterlights to ensure proper operation. (Life Float and Ring Life Buoy) This shall be accomplished prior to any night opertions and in no case later than 08 Nov 93.
Navigation
Issued 10 August 1988
Resolved
RELOCATE STERN LIGHT.
Casualty record · 1
4 August 2013Routine · role: Involved in a Marine Casualty · 1 injured · activity 4678479
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.