Records from 1988 to 2020. Most recent: inspection, 14 December 2020.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 27
14 December 2020
Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 7111656
14 April 2008
Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 3183789
20 October 2006
Internal Structural Exam · Hull Examination
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2804630
26 July 2006
Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 2725578
25 August 2005
Annual Inspection · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2471492
27 September 2004
Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2206291
4 June 2004
Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2092119
30 July 2003
Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1862457
19 June 2003
Deficiency Check · Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1821632
21 August 2002
Annual Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1664368
18 July 2002
Hull Examination · Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1647903
21 May 2001
COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1366349
13 July 2000
Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1418734
26 April 2000
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1470260
15 July 1999
Deficiency Check · Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1384226
9 July 1998
COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1453496
23 April 1998
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1414985
8 May 1997
Deficiency Check · Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1419773
30 May 1996
Hull Examination · Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1404096
1 June 1995
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1435646
20 July 1994
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 870318
12 May 1994
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1176744
13 July 1993
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 846504
2 June 1992
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 949754
6 May 1992
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 943745
17 May 1988
Initial Certification
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 888463
1 April 1988
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 890458
Construction/Loadline › Hull › Bottom Plating
Issued 26 July 2006
Resolved
Hull inspection was due on 30 JUN 06. Vessel not to operate with passengers until it has satisfactorily completed a credit hull inspection.
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 August 2006
Resolved 14 December 2020
Resolution: Deficiency cleared for administrative purpose only.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 25 August 2005
Resolved
Provide proper fire extinguisher brackets for all onboard portable fire extinguishers.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 September 2005
Resolution: Installed.
Lifesaving › Lifefloat › Painter
Issued 25 August 2005
Resolved
Properly attach lifefloat painter to vessel and provide 2 paddles for each lifefloat.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 25 August 2005
Resolved 23 September 2005
Resolution: Attached and installed.
Engineering › Sea-water System (primary cooling) › Sea Chest
Issued 25 August 2005
Resolved
Cap or plug open/unused seachest piping FWD and in engine room.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 25 August 2005
Resolved 23 September 2005
Resolution: Installed.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 25 August 2005
Resolved
Provide 3'-6' line IWO lifefloat light.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 25 August 2005
Resolved 23 September 2005
Resolution: Installed.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 25 August 2005
Resolved
Properly mark vessels hull with name and hailing port IAW 46 CFR 67.123. Ensure hailing port matches Certificate of Documentation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 October 2005
Resolved 7 November 2006
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 25 August 2005
Resolved
Provide drug consortium enrollment certificate listing all crewmembers IAW 46 CFR 16.230.
Condition: Unknown
Action required: 705 - Other - as specified
Due 23 October 2005
Resolved 14 December 2020
Resolution: Deficiency cleared for administrative purpose only.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 25 August 2005
Resolved
Repair FWD and AFT MSD's IAW 33 CFR 159.7.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 October 2005
Resolved 7 November 2006
Documentation › Safety Management System › Company Responsibility/Authority Documentation
Issued 27 September 2004
Resolved
Missing Employee Assistance Program Placard.
Action required: 705 - Other - as specified
Due 30 September 2004
Resolved 27 September 2004
Resolution: Made copy of Employee Assistance Program sheet from company packet.
Construction/Loadline › Structures › Superstructure
Issued 27 September 2004
Resolved
Three windows in Bridge and Accomodations spaces were cracked caused by hurricane.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 September 2004
Resolved 27 September 2004
Resolution: Replaced cracked windows with new windows.
Navigation › Piloting/Steering › US Coast Pilot
Issued 27 September 2004
Resolved
Outdated Coast Pilot
Action required: 705 - Other - as specified
Due 30 September 2004
Resolved 27 September 2004
Resolution: Replaced old coast pilot with current coast pilot
Navigation › Piloting/Steering › Coast Guard Light List
Issued 27 September 2004
Resolved
Only had on board an old CG Light List.
Action required: 705 - Other - as specified
Due 30 September 2004
Resolved 27 September 2004
Resolution: Purchased new CG Light list
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 27 September 2004
Resolved
Missing Nav Rules
Action required: 705 - Other - as specified
Due 30 September 2004
Resolved 27 September 2004
Resolution: Purchased Current Nav Rules
Engineering › Fuel Oil Service System › Filter
Issued 27 September 2004
Resolved
Raycore filters had plastic pet cock inserted as the drain plug. Required to have Metal plug in case of fire.
Action required: 705 - Other - as specified
Due 30 September 2004
Resolved 27 September 2004
Resolution: Replaced plastic plug with metal plug
Engineering › Fuel Oil Service System › Valve, Control
Issued 27 September 2004
Resolved
Re connect new fuel oil valve shutdown pull and show proper operation.
Action required: 705 - Other - as specified
Due 30 September 2004
Resolved 27 September 2004
Resolution: Reconnected fuel shutoff cable and showed proper operation.
Documentation › Certificates/Documents
Issued 19 June 2003
Resolved
Provide current documentation. LEGACY COMPONENT DESC: Certificate of Documentation (CG-1270)
Action required: 705 - Other - as specified
Due 3 August 2003
Resolved 30 July 2003
Documentation › Certificates/Documents
Issued 19 June 2003
Resolved
Provide confirmation of maritime consortium enrollment.
Action required: 705 - Other - as specified
Due 3 August 2003
Resolved 30 July 2003
Communications › Radio Communications
Issued 19 June 2003
Resolved
Provide EPRIB NOAA Registration. Master has copy of paper work that has been sent to NOAA. LEGACY COMPONENT DESC: EPIRB
Action required: 705 - Other - as specified
Due 3 August 2003
Resolved 30 July 2003
Stability › Watertight Integrity
Issued 19 June 2003
Resolved
Install hose clamps on all overbrd discharges.
Action required: 705 - Other - as specified
Due 3 August 2003
Resolved 30 July 2003
Engineering › Bilge Water Management System
Issued 19 June 2003
Resolved
Label bilge manifold. LEGACY COMPONENT DESC: Manifold
Action required: 705 - Other - as specified
Due 3 August 2003
Resolved 30 July 2003
Stability › Watertight Integrity
Issued 19 June 2003
Resolved
Install dead covers for port lights, must be hinged (5 each).
Action required: 705 - Other - as specified
Due 3 July 2003
Resolved 30 July 2003
Lifesaving › Hand Flares
Issued 21 August 2002
Resolved
Provide 6 red hand flares within current expiration date. Restricted vessel to daylight hours only.
Action required: 705 - Other - as specified
Due 12 September 2002
Resolved 2 July 2003
Lifesaving › Buoyant Apparatus
Issued 21 August 2002
Resolved
Provide spacer between lifefloats.
Action required: 705 - Other - as specified
Due 12 September 2002
Resolved 2 July 2003
Lifesaving › Lifebuoys
Issued 21 August 2002
Resolved
Mark life ring with vessel's name.
Action required: 705 - Other - as specified
Due 12 September 2002
Resolved 2 July 2003
Lifesaving › Lifebuoys
Issued 21 August 2002
Resolved
Re-new retro-reflective tape on life ring.
Action required: 705 - Other - as specified
Due 12 September 2002
Resolved 2 July 2003
Engineering › Fuel Oil Service System
Issued 21 August 2002
Resolved
Label F/O shut off valve. LEGACY COMPONENT DESC: Valve, Control
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 September 2002
Resolved 2 July 2003
Communications › Alarms/Indicators
Issued 21 August 2002
Resolved
Provide visible and audible bilge high level alarms. LEGACY COMPONENT DESC: Bilge Alarm
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 12 September 2002
Resolved 2 July 2003
Electrical › Lighting (service)
Issued 21 August 2002
Resolved
Place coverings on interior lights. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 September 2002
Resolved 2 July 2003
Lifesaving
Issued 21 May 2001
Resolved
PROVIDE PROPER FIRST AID KIT.
Condition: Unknown
Due 4 June 2001
Resolved 17 July 2002
Electrical
Issued 21 May 2001
Resolved
PERMANENTLY INSTALL AIR CONDITION RECIRCULATION PUMP.
Condition: Unknown
Due 21 June 2001
Resolved 17 July 2002
Lifesaving
Issued 21 May 2001
Resolved
REPLACE LIFEFLOAT PENDANTS FOR BOTH LIFEFLOATS.
Condition: Unknown
Due 4 June 2001
Resolved 17 July 2002
Lifesaving
Issued 13 July 2000
Resolved
PROVIDE EXPIRATION TAG FOR HYDROSTATIC RELEASE ON EPIRB. 46CFR184.502
Condition: Unknown
Due 13 July 2000
Resolved 13 July 2000
Documentation
Issued 13 July 2000
Resolved
PROVIDE PROOF OF MEMBERSHIP IN RANDOM DRUG TESTING PROGRAM.
Condition: Unknown
Due 13 July 2000
Resolved 13 July 2000
Lifesaving
Issued 13 July 2000
Resolved
PROVIDE PROOF OF NOAA REGISTRATION FOR EPIRB. 46CFR184.502
Condition: Unknown
Due 13 July 2000
Resolved 13 July 2000
Construction/Loadline
Issued 15 July 1999
Resolved
INSTALL BILGE HIGH LEVEL ALARMS IN THE FWD HOLD, ENGINE ROOM COMPARTMENT, AND RUDDER COMPARTMENT IAW 46CFR182.530.
Condition: Unknown
Due 15 July 1999
Resolved 15 July 1999
Lifesaving
Issued 15 July 1999
Resolved
REGISTER 406 EPIRB WITH NOAA IAW 46CFR180.64.
Condition: Unknown
Due 15 August 1999
Resolved 17 August 1999
Engineering
Issued 15 July 1999
Resolved
RECONNECT FUEL SHUT OFF FOR MDE AND INSTALL FUEL SHUT OFF FOR GENERATOR ANDAIR COMPRESSOR ENGINE.
Condition: Unknown
Due 15 August 1999
Resolved 17 August 1999
Engineering
Issued 15 July 1999
Resolved
INSTALL FLAME IMPINGMENT BOWLS ON BOTH MDE RACOR FILTERS.
Condition: Unknown
Due 15 August 1999
Resolved 17 August 1999
Engineering
Issued 15 July 1999
Resolved
REPLACE FUEL HOSE FOR GENERATOR AND AIR COMPRESSOR ENGINE WITH SAE-J1942 APPROVED FUEL HOSE.
Condition: Unknown
Due 15 August 1999
Resolved 17 August 1999
Accommodation/Occupational Safety
Issued 15 July 1999
Resolved
REPLACE STARBOARD WINDOW IN THE PASSENGER ACOMMODATION SPACE.
Condition: Unknown
Due 15 July 1999
Resolved 15 July 1999
Navigation
Issued 8 May 1997
Resolved
REPLACE CRACKED HYDRAULIC CABLE FOR STEERING. VESSEL MAY NOT OPERATE UNTILREQUIREMENT IS MET.
Condition: Unknown
Due 9 June 1997
Resolved 30 May 1997
Documentation
Issued 17 May 1988
Resolved
PROVIDE AN FCC SAFETY CERTIFICATE
Condition: Unknown
Due 17 May 1988
Resolved 17 May 1988
Fire Fighting
Issued 17 May 1988
Resolved
PROVIDE ONE MORE B-II FIRE EXTINGUISHER IN ADDITION TO THOSE ALREADY ON BOARD
Condition: Unknown
Due 17 May 1988
Resolved 17 May 1988