Records from 2016 to 2026. Most recent: inspection, 10 February 2026.
Inspection history · 22
10 February 2026
Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8309162
23 October 2025
Deficiency Check · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8257896
18 February 2025
Examination of Repairs · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8080558
25 July 2024
COI Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7967017
14 February 2024
Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7865560
13 February 2024
Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7859664
1 May 2023
Plan Review "T" Boat
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7680340
13 February 2023
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7632767
23 August 2022
Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7541987
28 June 2022
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7484180
16 February 2022
Examination of Repairs
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7397495
25 May 2021
Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7202636
18 May 2021
COI Inspection · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7198884
6 January 2021
Deficiency Check · Examination of Repairs
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7120545
14 August 2020
Construction Oversight · Annual Inspection · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7032703
13 January 2020
Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6887982
19 August 2019
DAPI Audit · Plan Review "T" Boat · Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6788547
28 August 2018
Annual Inspection · DAPI Audit
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6525642
16 January 2018
Hull Examination · Internal Structural Exam · Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6329619
15 May 2017
Annual Inspection · DAPI Audit
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6144708
17 May 2016
Deficiency Check · DAPI Audit · COI Inspection · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5879720
17 February 2016
Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 5816957
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 28 October 2025
Resolved
On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate a high water level.
None of the high bilge level alarms were visible or audible at the control station.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 November 2025
Resolution: [name withheld] and EMC Peters attended vessel and witnessed satisfactory operation of bilge high level alarms.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 28 October 2025
Resolved
The owner, managing operator, or a qualified servicing facility as applicable must conduct the following inspections and tests: portable extinguishers must be inspected and maintained in accordance with NFPA 10.
Portable extinguishers have not received annual maintenance.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 November 2025
Resolved 16 December 2025
Resolution: Vessel o/o had extinguishers serviced by fire company.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 28 October 2025
Resolved
Examine and test by operation all watertight closures in the hull, decks and bulkheads.
Engine room emergency escape hatch was not operable.
46 CFR 176.25-5(b) (1994)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 November 2025
Resolved 16 December 2025
Resolution: Witnessed satisfactory operation of engine room escape hatch.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 28 October 2025
Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 50 millimeters (2 inches) high: “EMERGENCY EXIT, KEEP CLEAR”.
Door leading to engine room escape hatch was not labeled.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 November 2025
Resolved 16 December 2025
Resolution: O/o labeled door and scuttle for emergency exit.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 October 2025
Resolved
The shutoff valve at the tank shall be operable from outside the tank compartment, preferably from an accessible position on the weather deck.
Port fuel shut off valve did not completely close when remotely pulled.
46 CFR 182.20-40(b) (1994)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 November 2025
Resolved 10 February 2026
Resolution: Cable was adjusted and valve closes.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 28 October 2025
Resolved
All electrical installations shall be to the satisfaction of the Cognizant Officer in Charge, Marine Inspection.
Stern light wire in lazarette is pinched at a 90 degree bend and not properly supported.
46 CFR 183.01-15 (1994)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 November 2025
Resolved 16 December 2025
Resolution: Electrical conduit rapaired and affixed to bulkhead.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 October 2025
Resolved
Each rescue boat and ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant.
Observed no retroreflective tape on life buoy.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 November 2025
Resolved 5 November 2025
Resolution: [name withheld] and EMC Peters attended vessel to witness corrected retroreflective tape on lifebuoy.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 October 2025
Resolved
An adult life jacket must be provided for each person carried on board a vessel.
There were only 143 adult life jackets onboard. Vessel is restricted to the carriage of 137 passengers until rectified.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 16 December 2025
Resolution: O/o brought 12 additional life jackets onboard.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 28 October 2025
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date U.S. Coast Pilot and Light Lists.
Vessel did not have up to date Coast Pilot and Light Lists onboard.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 November 2025
Resolved 16 December 2025
Resolution: O/o printed copies of publications to retain onboard.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 18 February 2025
Resolved
(d) Whenever damage or deterioration to hull plating or structural members that may affect the seaworthiness of a vessel is discovered or suspected, the cognizant OCMI may conduct an internal structural examination in any affected space including fuel tanks, and may require the vessel to be drydocked or taken out of service to assess the extent of the damage, and to effect permanent repairs. The OCMI may also decrease the drydock examination intervals to monitor the vessel's structural condition.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 February 2025
Resolved 21 August 2025
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 20 August 2024
Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with § 80.59 once every five years. Vessels
FCC Radiotelephony Certificate is expired. 47 CFR 80.903 705c - limited to operating 1000ft from shore.
Action required: 705 - Other - as specified
Due 20 September 2024
Resolved 23 August 2024
Resolution: Sector Charleston Domestic Inspections Branch received a copy of the Safety Radio Certificate issued on August 20, 2024
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 20 August 2024
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. Multiple items were identified that require repairs, not affecting the seaworthiness of the vessel. Drydock dates have been amended next drydock date is due 31Jan2025. 46 CFR 177.100 10c
Action required: 10 - Deficiency Rectified
Resolved 20 August 2024
Resolution: Drydock dates have been amended next drydock date is due 31Jan2025. Deficiency rectified.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 14 February 2024
Resolved
46 CFR 176.500: (1) Annual inspection. Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date.
(i) You must contact the cognizant OCMI to schedule an inspection at a time and place which he or she approves. No written application is required.
Vessel is restricted from carrying passengers until their annual inspection has been completed to the satisfaction of the cognizant OCMI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 August 2024
Resolution: Vessel received renewal COI. Def rectified.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 1 May 2023
Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. The overcurrent protection for the Engineroom lights and Step lights activated when energized and could not be reset. Troubleshoot problem and provide a plan proposal to repair lights and show proper operation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2023
Resolved 8 June 2023
Resolution: Received third party report showing repairs made to the engineroom lights and step lights.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 August 2022
Resolved
L [vessel]- Fire hose shall be 1.5 inches in diameter and 50 feet in length. The starboard fire hose had several pin holes during testing requiring replacement.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 August 2022
Resolved 28 September 2022
Resolution: A new approved hose was placed in service.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 23 August 2022
Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. The lights for the engineroom were not working at the time of the inspection.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 August 2022
Resolved 28 September 2022
Resolution: The lighting was repaired for the engineroom.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 14 August 2020
Resolved
Significant wastage found in pilothouse deck and engine room overhead. Vessel shall have satisfactory evidence of structural adequacy. Vessel restricted to carriage of 49 passengers. Vessel required 2 deckhands [name withheld] shall be conducted every 15 minutes underway. Starboard head to be marked out of service.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 October 2020
Resolved 30 April 2021
Resolution: Vessel completed all repairs.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 13 January 2020
Resolved
A vessel must comply with the structural design requirements of one of the standards for the hull material of the vessel. Centerline engine Room aft is wasted is wasted. 46CFR 177.300
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 June 2020
Resolution: Plates were replaced and tested as notated above in the narrative.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 13 January 2020
Resolved
A vessel must comply with the structural design requirements of one of the standards for the hull material of the vessel. Starboard side under escape hatch is wasted. 46CFR 177.300
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 June 2020
Resolution: Sat
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 13 January 2020
Resolved
A vessel must comply with the structural design requirements of one of the standards for the hull material of the vessel. Starboard side side shell Engine room is wasted. 46CFR 177.300
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 June 2020
Resolution: Plates were replaced and tested as notated above in the narrative.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 13 January 2020
Resolved
A vessel must comply with the structural design requirements of one of the standards for the hull material of the vessel. Inside keel cooler Starboard side is wasted. 46CFR 177.300
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 June 2020
Resolution: Plates were replaced and tested as notated above in the narrative.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 August 2019
Resolved
Line on ring bouy deteriorated.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2019
Resolved 27 September 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 August 2019
Resolved
Flexible piping on bilge suction in shaft log compartment needs to be removed.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 31 December 2019
Resolved 12 June 2020
Resolution: The flexible piping in way of the electric bilge pumps in both shaft logs was removed and replaced with a corrugated flexible hose. According to the owner, the original flexible hose was more rigid and tended to kink on a hard bend.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 August 2019
Resolved
Fuel shutoff is inoperable and does not display placard.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 August 2019
Resolved 4 October 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 August 2019
Resolved
Wire bundle for port main diesel engine is under a lot of tension and is close to pulling apart.
Action required: 705 - Other - as specified
Due 31 December 2019
Resolved 12 June 2020
Resolution: The wire bundle off the port main engine was loosened and no longer had a strain on it.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 August 2019
Resolved
Battery terminals on both port and stbd engines need to be tightened and the wing bolts need to be removed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2019
Resolved 3 November 2021
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 20 August 2019
Resolved
Sea chest is missing cap on valve in engine room.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2019
Resolved 3 October 2019
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 August 2019
Resolved
Pin on CO2 bracket is missing in engine room.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2019
Resolved 27 September 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 August 2019
Resolved
Port side expansion tank needs approved flexible piping.
Action required: 705 - Other - as specified
Due 31 December 2019
Resolved 12 June 2020
Resolution: A new hard pipe was fitted in to place in way of the port side expansion tank.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 29 August 2018
Resolved
Vessel's fire hoses, both port and stbd, have multiple leaks and holes. Vessel must replace fire hoses to the satisfaction of the attending USCG.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 September 2018
Resolved 19 September 2018
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 29 August 2018
Resolved
Port engine missing guards over moving parts. Vessel must correct to the satisfaction of the attending USCG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 October 2018
Resolved 12 June 2020
Resolution: A protective guard was provided that was made in two sections and hinged. This guard protected the emergency escape ladder just forward of the port side main engine and provided protection for both the power take off on the main engine and the clutch wit
Electrical › Lighting (service) › Conductor
Issued 23 May 2016
Resolved
Issued CG 835 no sail due to multiple electrical deficiencies to include extension cords, open lamps, missing covers, and improperly installed lamps in fixtures. The lamps installed, in various fixtures, were melting the lens covers. Most of the deficiencies were located throughout the engineroom. 46CFR183.340 was applied.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 June 2016
Resolution: Electrical items noted above resolved.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 3 March 2016
Resolved
Properly repair fuel tank, hull and longitudinals where severe pitting is located (Port and stbd fuel tanks). 46CFR176.20-1
Action required: 705 - Other - as specified
Resolved 9 May 2016
Resolution: Corrected.
Construction/Loadline › Penetrations › Weld
Issued 3 March 2016
Resolved
Submit repair proposal for hole IWO stbd shaft penetration on E/R bulkhead and make proper repairs. 46CFR176.20-1
Action required: 705 - Other - as specified
Resolved 6 May 2016
Resolution: Corrected.
Construction/Loadline › Hull › Longitudinal Frame
Issued 3 March 2016
Resolved
Crop and renew wasted deck longitudinals in #1 hold (collision bulkhead) and #2 hold as marked. 06 in #1 hold, 01 in #2 hold and repair transverse in #2 hold. 46CFR176.20-1
Action required: 705 - Other - as specified
Resolved 6 May 2016
Resolution: Corrected.
Construction/Loadline › Hull › Hull Plating
Issued 3 March 2016
Resolved
Crop and renew hull plating IWO 02 doublers plates stbd side forward, minimum insert 18" X 18". 46CFR176.20-1
Action required: 705 - Other - as specified
Resolved 6 May 2016
Resolution: Corrected.
Construction/Loadline › Hull › Weld
Issued 3 March 2016
Resolved
Gouge and re-weld flush top weld for aft insert (6" X 11") IWO stbd rudder. 46CFR176.20-1
Action required: 705 - Other - as specified
Resolved 6 May 2016
Resolution: Corrected.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 3 March 2016
Resolved
Crop and renew 02 wasted deck longitudinals in shaft alleyway compartment. 46CFR176.20-1
Action required: 705 - Other - as specified
Resolved 6 May 2016
Resolution: Corrected.
Engineering › Bilge Water Management System › Piping
Issued 3 March 2016
Resolved
Replace leaky union joint for bilge system located in wine cellar bilge. 46CFR182-25.5
Action required: 705 - Other - as specified
Resolved 6 May 2016
Resolution: Corrected.
Engineering › Sea-water System (primary cooling) › Piping
Issued 3 March 2016
Resolved
Replace worn expansion joint for stbd keel cooler. 46CFR176.25-10
Action required: 705 - Other - as specified
Resolved 6 May 2016
Resolution: Corrected.
Construction/Loadline › Hull › Bracket
Issued 3 March 2016
Resolved
Crop and renew bottom stanchion railing on upper deck as marked, 2nd from welded gate. 46CFR176.20-1
Action required: 705 - Other - as specified
Resolved 6 May 2016
Resolution: Corrected.
Construction/Loadline › Hull › Side Shell
Issued 3 March 2016
Resolved
Submit repair proposal for wasted deck and fiberglassed side shell IWO fuel fill and ventilation containment area. Repair holed ventilation pipe for port side. 46CFR176.20-1
Action required: 705 - Other - as specified
Resolved 6 May 2016
Resolution: Corrected.
Documentation › Markings/Placards › Warning Signs
Issued 3 March 2016
Resolved
Post 02 emergency exit signs in engine room. 46CFR185.606
Action required: 705 - Other - as specified
Resolved 29 August 2018
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 March 2016
Resolved
Re-connect wire for bilge pump in Engine Room. 46CFR183.200
Action required: 705 - Other - as specified
Resolved 6 May 2016
Resolution: Corrected.
Engineering › Fuel Oil Service System › Valve
Issued 3 March 2016
Resolved
Make proper repairs to emergency fuel shut-off valve handle. 46CFR185.608
Action required: 705 - Other - as specified
Resolved 6 May 2016
Resolution: Corrected.
Construction/Loadline › Penetrations › Weld
Issued 3 March 2016
Resolved
Properly repair holes in bulkhead forward of fuel tank along bottom seam, port and stbd side. 46CFR176.20-1
Action required: 705 - Other - as specified
Resolved 9 May 2016
Resolution: Corrected.