MAURY USCG vessel records Sign in
← All vessels

LADY K

LADY K is a 1988 passenger vessel (inspected). The Coast Guard has recorded 63 inspections since 1989, most recently in May 2023, along with 136 deficiencies and 1 operational control.

Records from 1989 to 2023. Most recent: inspection, 11 May 2023.

Built
1988
Last inspected
11 May 2023
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCX9763
308516
Flag
UNITED STATES
368038170
Maury page id
psix-308516

Inspections, by type

…with no type recorded5
Years with a record 29 calendar years (1989–2023)
The 63 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)44.0 ft × 14.0 ft × 6.0 ft
Registered tonnagegross 24 / net 19
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBONNER YACHTS · WETUMPKA, AL, UNITED STATES · built 1988
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portSUNNY HILLS, FL
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it24 - Simplified, Gross Ton
19 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDK2715MMSI 368038170 · active · voluntarily equipped · granted 12 May 2018, expires 12 May 2028
WDH6847MMSI 367642210 · expired · voluntarily equipped · granted 30 September 2014, cancelled 7 December 2024 · licensed under a name not among this hull’s recorded names (not shown)
WCX9763MMSI 367338070 · expired · compulsorily equipped · granted 20 February 2008, cancelled 12 May 2018 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 63

11 May 2023 Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7686043
28 March 2023 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7658387
7 April 2022 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7427202
24 March 2021 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7161893
1 March 2021 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7146841
1 June 2020 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6971194
1 May 2019 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6675180
28 March 2019 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6651911
14 November 2018 Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6580538
4 May 2018 Administrative Inspection · Deficiency Check · DAPI Audit · COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6169400
28 June 2017 Administrative Inspection · Simplified Stability Test
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6198419
6 December 2016 Administrative Inspection · Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6063561
28 April 2016 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5865637
15 March 2016 Deficiency Check · Administrative Inspection · DAPI Audit · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5833842
22 February 2016 Administrative Inspection · COI Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5819899
18 August 2014 Annual Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4951794
30 December 2008 Deficiency Check · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3382694
8 May 2008 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3201081
23 February 2008 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3152302
13 April 2007 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2907205
15 March 2007 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2888276
2 March 2007 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2880722
14 February 2007 Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2871636
19 August 2006 Type not recorded
No type recorded · USCGC COBIA (WPB 87311) · USCG Heartland District (CGD-H) · Activity 2795048
1 February 2006 COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2565958
12 October 2005 Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2513108
7 March 2005 Deficiency Check · Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2305196
28 February 2005 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2301004
1 July 2004 Annual Inspection · Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2127210
23 February 2004 Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2010279
18 March 2003 Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1749203
23 January 2003 Internal Structural Exam · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1727000
15 February 2002 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1493531
31 January 2002 Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1479167
5 March 2001 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1058168
7 February 2001 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1058629
25 January 2001 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 825443
19 June 2000 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 137427
12 April 2000 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1049253
9 February 2000 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 815527
1 March 1999 Re-Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1390925
11 March 1998 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1127088
9 February 1998 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1418312
7 March 1997 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1098238
7 February 1997 Re-Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1390448
11 March 1996 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 885653
9 February 1996 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1363497
9 February 1995 Hull Examination · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1394290
14 February 1994 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 853498
30 April 1993 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 838896
24 February 1993 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1142903
18 February 1993 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 832459
28 April 1992 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1269772
25 March 1992 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 951767
13 February 1992 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1266128
15 May 1991 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 939472
14 March 1991 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1222971
14 February 1991 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1222969
6 February 1991 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 903343
14 June 1990 Drydock Extension
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 924297
7 February 1990 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1217616
2 March 1989 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1200157
14 February 1989 Initial Certification · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1350221

Deficiency record · 136

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 April 2022 Resolved
Inspect machinery in accordance with 46 CFR 176.804. Fuel line for generator is not of an approved type.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2022
Resolved 8 February 2024
Resolution: Pulled COI from vessel.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 7 April 2022 Resolved
Inspect watertight closures in accordance with 46 CFR 176.802. Mid deck hatch will not seat properly.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2022
Resolved 8 February 2024
Resolution: Pulled COI from vessel.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 1 June 2020 Resolved
Replace hydrostatic release unit for EPIRB. Vessel's HRU was found to be expired 05/20.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2020
Resolved 1 June 2020
Resolution: Owner replaced HRU with new one.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 May 2019 Resolved
Tighten shaft packing around starboard shaft seal.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2019
Resolved 1 June 2020
Resolution: Shaft seal was tightened.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 May 2019 Resolved
Provide appropriate lifejacket donning placard.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2019
Resolved 1 June 2020
Resolution: Provided correct life jacket donning placard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 May 2019 Resolved
Provide appropriate electrical bonding for fuel fill pipes for both fuel tanks.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2019
Resolved 1 June 2020
Resolution: Bonding wires were installed.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 1 May 2019 Resolved
Provide copy of FCC Station license.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2019
Resolved 1 June 2020
Resolution: FCC station license provided.
Electrical › Electric Generation Source (service) › Generator
Issued 31 May 2018 Resolved
Vessel is prohibited from using installed generator to supply power to vessel. (Generator has been verified disconnected by USCG inspector). Electrical plan has been submitted to MSC for approval.
Action required: 705 - Other - as specified
Due 31 July 2018
Resolved 8 February 2024
Resolution: Pulled COI from vessel.
Engineering › Shafting/Propeller Arrangements › Strut Bearing
Issued 22 March 2017 Resolved
Replace Port and STBD Cutless bearings.
Action required: 705 - Other - as specified
Due 29 March 2017
Resolved 28 March 2017
Resolution: Vessel replaced both cutlass bearings
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 14 February 2017 Resolved
Submit fuel tank design/construction plan to MSC for approval. Vessel currently has fiberglass fuel tanks wiich tank top has been cut off.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 April 2017
Resolved 5 May 2017
Resolution: Approved plans witnessed.
Documentation › Logs/Records › Drug Test Records
Issued 23 March 2016 Resolved
New crew member was not added to DAPI.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 March 2016
Resolved 24 March 2016
Resolution: Provided proof of new crewmember added to DAPI.
Navigation › Electronic Positioning › Radio Direction Finding Device
Issued 23 March 2016 Resolved
EPIRB battery expired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 March 2016
Resolved 24 March 2016
Resolution: New EPIRB purchased and registered.
Lifesaving › Hand Flares › Expired
Issued 23 March 2016 Resolved
Not enough flares for oceans route.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 March 2016
Resolved 24 March 2016
Resolution: Purchsed new red flares.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 23 March 2016 Resolved
Retro tape on some life vest are faded.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 April 2016
Resolved 28 April 2016
Resolution: Replaced worn retro tape with new.
Engineering › Fuel Oil Service System › Hose
Issued 23 March 2016 Resolved
Fuel and steering line needs overhead clamp installed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 April 2016
Resolved 28 April 2016
Resolution: Installed clamps on lines in laz.
Fire Fighting › Means of Escape › Corridors
Issued 23 March 2016 Resolved
Escape hatch needs latched so that it won't open on its own.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 April 2016
Resolved 28 April 2016
Resolution: Latch installed.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 23 March 2016 Resolved
FWD hatch over void was loose, needs tightened.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 March 2016
Resolved 23 March 2016
Resolution: Was repaired and tested during exam.
Electrical › Electric Supply System (service) › Cable
Issued 23 March 2016 Resolved
Dead end wires under operation console needs wire caps or removed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 April 2016
Resolved 28 April 2016
Resolution: Dead end wires were removed under console.
Operations/Management › Drills/Instruction › Not Conducted
Issued 23 March 2016 Resolved
New record of new crew member drills being conducted.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 April 2016
Resolved 28 April 2016
Resolution: Underway drills conducted with crew.
Electrical › Electric Supply System (service) › Cable
Issued 23 March 2016 Resolved
Outlet in E/R needs new cover.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 April 2016
Resolved 28 April 2016
Resolution: New outlet cover installed.
Engineering › Fuel Oil Service System › Filter
Issued 23 March 2016 Resolved
Racor filter needs plug on valve.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 April 2016
Resolved 28 April 2016
Resolution: Added plug to racor filter.
Engineering › Bilge Water Management System › Piping
Issued 23 March 2016 Resolved
Bilge piping in E/R that is not being used, needs plug.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 April 2016
Resolved 28 April 2016
Resolution: Plugged unused bilge pipe.
Fire Fighting › Fixed Halon Fire Extinguishing System › Tanks
Issued 2 March 2016 Resolved
Vessel did not have an approved fixed fire-fighting onboard. Vessel must have an approved fixed fire-fightining system IAW 46 CFR 181.400; this must be done prior to passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 March 2016
Resolved 28 April 2016
Resolution: Fixed system installed and working. Checked inspection paper work.
Lifesaving › Lifefloat › Float-free Link
Issued 18 August 2014 Resolved
Weak link for life float line is not connected to the vessel. this must be attached in accordance with 46CFR180.137 (a) (3)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 August 2014
Resolved 21 August 2014
Resolution: Float free link attached to vessel.
Lifesaving › Liferaft Equipment › Paddle
Issued 18 August 2014 Resolved
Life saving paddles have incorrect vessel names, they must have the correct vessel name clearly labeled in accordance with 46 CFR 185.604 (g)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 September 2014
Resolved 18 September 2014
Resolution: Labeled life float and paddles.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 18 August 2014 Resolved
Improperly marked stowage for child PFD's. All storage of child PFD's must be clearly marked in accordance with 46 CFR 180.78 (a) (5)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 September 2014
Resolved 18 September 2014
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 18 August 2014 Resolved
Retroreflective tape on one child and one adult PFD's was worn. All PFD's must be acceptable as per 46 CFR 180.71(c)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 September 2014
Resolved 18 September 2014
Engineering › Fuel Oil Service System › Hose
Issued 18 August 2014 Resolved
06 nonmetallic flexible fuel hoses penetrate watertight bulkheads and decks without any kind of fittings. This installation is prohibited by 46 CFR 182.20-40(a)(2)(i) (old T) . This shall be corrected by/during the next drydock.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 March 2015
Resolved 20 April 2015
Resolution: Fuel fittings thru aft engine bulkhead were corrected. Installation of fittings complete and sealed.
Electrical › Electric Supply System (service) › Cable
Issued 18 August 2014 Resolved
Dead end wires inside access above sewage tank. All wires must be removed in accordance with 46 CFR 183.01 - 15 (a)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 September 2014
Resolved 18 September 2014
Resolution: Wires removed.
Fire Fighting › Ventilation Systems › Ducts
Issued 18 August 2014 Resolved
Ventilation from engine room was not working properly in the event of a fire. This must be corrected in accordance with 46 CFR 181.20-35 (a)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 September 2014
Resolved 18 September 2014
Resolution: Cones were made to plug off engine room vents.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 18 August 2014 Resolved
Coupling hose on exhaust system and cooling water intake from seachest are missing double clamps or loose. These must have clamps as per 46 CFR 176.804
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 September 2014
Resolved 18 September 2014
Electrical › Electric Generation Source (service) › Generator
Issued 18 August 2014 Resolved
No guards exist around the generator engine rotating pullys. Suitable protection must be in place per 46 CFR 177.35-15(a) (Old T).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 September 2014
Resolved 18 September 2014
Resolution: Guards installed around pully''s.
Navigation › Piloting/Steering › Marine Charts
Issued 18 August 2014 Resolved
Navigation charts are out of date. All charts must be up to date or renewed as per 46 CFR 185.20-35(a). Last update was 2010.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 September 2014
Resolved 18 September 2014
Resolution: Charts corrected.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 18 August 2014 Resolved
Inadequate documentation exists for the drug testing program. Proper documentation must be provide per 46 CFR 16.
Condition: Improper/Lack of Maintenance
Due 17 September 2014
Resolved 27 April 2015
Resolution: Provided proper paper work.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 18 August 2014 Resolved
After installation of new SSB radio, new FCC station license, safety radio certificate and operator permit must be provided in accordance with 47 CFR 80.401.
Condition: Improper/Lack of Maintenance
Due 17 September 2014
Resolved 27 April 2015
Resolution: FCC station license updated with proper equipment.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 18 August 2014 Resolved
No emergency broadcast placard exists. Such a placard must be posted next to all radio installations per 46 CFR 184.506
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 September 2014
Resolved 18 September 2014
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 30 December 2008 Resolved
Repair/replace all loose railing leading to bow on main deck; outboard side of starboard railing and inboard side on the port railing.
Action required: 705 - Other - as specified
Resolved 11 February 2009
Resolution: Area of concern was repaired.
Lifesaving › Lifefloat › Lifeline
Issued 23 February 2008 Resolved
Repair/Replace deteriorated grabline on lifefloat.
Due 15 May 2008
Resolved 8 May 2008
Resolution: Grabline replaced
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 23 February 2008 Resolved
Tighten/secure handrails on bow.
Due 15 May 2008
Resolved 8 May 2008
Resolution: Handrails secured and brackets fabricated to strengthen handrails.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 23 February 2008 Resolved
Place lower rails on deck rail located on second deck as per 46 CFR 177.900
Due 15 May 2008
Resolved 8 May 2008
Resolution: Lower rail added.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 5 March 2007 Resolved
Replace the rotted and deteriorated grab line on the life ring in accordance with 46 CFR 180.70.
Action required: 705 - Other - as specified
Due 5 April 2007
Resolved 15 March 2007
Resolution: Replaced the rotted and deteriorated grab line on the life ring in accordance with 46 CFR 180.70.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 5 March 2007 Resolved
Provide a Coast Guard approved first aid kit in accordance with 46 CFR 184.710.
Action required: 705 - Other - as specified
Due 5 April 2007
Resolved 15 March 2007
Resolution: Provided a Coast Guard approved first aid kit in accordance with 46 CFR 184.710.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 5 March 2007 Resolved
Prove proper operation of the stern light in accordance with 46 CFR 183.420.
Action required: 705 - Other - as specified
Due 5 April 2007
Resolved 15 March 2007
Resolution: Proved proper operation of the stern light in accordance with 46 CFR 183.420.
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 March 2007 Resolved
Remove dead end wires near the forward bulkhead in the engine room in accordance with 46 CFR 183.340.
Action required: 705 - Other - as specified
Due 5 April 2007
Resolved 15 March 2007
Resolution: Removed dead end wires near the forward bulkhead in the engine room in accordance with 46 CFR 183.340.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 5 March 2007 Resolved
Prove proper operation of the smoke detection system in accordance with 46 CFR 181.400.
Action required: 705 - Other - as specified
Due 5 April 2007
Resolved 15 March 2007
Resolution: Proved proper operation of the smoke detection system in accordance with 46 CFR 181.400.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 14 February 2007 Resolved
Clean bilge in the engine room and make ready for inspection.
Action required: 705 - Other - as specified
Due 14 March 2007
Resolved 15 February 2007
Resolution: Cleaned bilge and made ready for inspection
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 14 February 2007 Resolved
Make starboard shaft and propeller ready for inspection.
Action required: 705 - Other - as specified
Due 14 March 2007
Resolved 15 February 2007
Resolution: Made the starboard shaft and propeller ready for inspection
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 14 February 2007 Resolved
Make repairs to railing on the starboard side and on the fantail.
Action required: 705 - Other - as specified
Due 14 March 2007
Resolved 15 February 2007
Resolution: Made repairs to railing on the starboard side and on the fantail.
Construction/Loadline › Structures › Deck Plating
Issued 14 February 2007 Resolved
Grind areas on the back deck around the fish box and make ready for inspection prior to making repairs.
Action required: 705 - Other - as specified
Due 14 March 2007
Resolved 15 February 2007
Resolution: grind areas on the back deck around the fish box and made ready for inspection
Stability › Watertight Integrity › Weathertight Enclosure
Issued 1 February 2006 Resolved
Replace gasket on emergency escape hatch to restore watertight integrity as per 46 CFR 171.124
Action required: 705 - Other - as specified
Due 17 March 2006
Resolved 17 March 2006
Resolution: Gasket replaced and found satisfactory.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 1 February 2006 Resolved
Replace gasket on lazarette hatch to restore watertight integrity as per 46 CFR 171.124.
Action required: 705 - Other - as specified
Due 17 March 2006
Resolved 17 March 2006
Resolution: Gasket replaced and found satisfactory
Accommodation/Occupational Safety › Occupational Safety › Smoking
Issued 1 February 2006 Resolved
Prove proper operation of two smoke alarms in accommodation space as per 46 CFR 181.400
Action required: 705 - Other - as specified
Due 17 March 2006
Resolved 17 March 2006
Resolution: Batteries replaced and detectors test satisfactory
Construction/Loadline › Structures › Air Pipe
Issued 1 February 2006 Resolved
Double clamp all vital systems piping including forward bilge pump at starboard main diesel engine suction as per 46 CFR 182.730
Action required: 705 - Other - as specified
Due 17 March 2006
Resolved 17 March 2006
Resolution: All vital system flexible hosing double clamped and found satisfactory.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 1 February 2006 Resolved
Provide cap for bilge manifold piping near forward bilge pump to maintain watertight integrity of subdivision bulkhead. 46 CFR 182.720
Action required: 705 - Other - as specified
Due 17 March 2006
Resolved 17 March 2006
Resolution: Pipe capped on bilge manifold system which was no longer in use due to use of independent pumps.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 1 February 2006 Resolved
Mount portable fire extinguisher in cabin as per 46 CFR 181.520
Action required: 705 - Other - as specified
Due 17 March 2006
Resolved 17 March 2006
Resolution: Portable fire extinguisher in cabin mounted.
Stability › Weathertight Integrity › General
Issued 1 February 2006 Resolved
Replace port side main deck cracked cabin window as per 46 CFR 177.1020
Action required: 705 - Other - as specified
Due 17 March 2006
Resolved 17 March 2006
Resolution: Port side main deck cabin window replaced and found satisfactory.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 1 February 2006 Resolved
Repair and prove operation of bomar hatch at rope locker where handle is missing/unable to open as per 46 CFR 171.124
Action required: 705 - Other - as specified
Due 17 March 2006
Resolved 17 March 2006
Resolution: New handle installed on hatch and found satisfactory.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 1 February 2006 Resolved
Tighten all forward deck rail courses as per 46 CFR 177.900
Action required: 705 - Other - as specified
Due 17 March 2006
Resolved 17 March 2006
Resolution: Loose rail courses tightened and found satisfactory.
Navigation › Electronic Positioning › Radio Direction Finding Device
Issued 1 February 2006 Resolved
Renew expired hydrostatic release for EPIRB as per 46 CFR 180.64
Action required: 705 - Other - as specified
Due 17 March 2006
Resolved 17 March 2006
Resolution: New hydrostatic release provided with replacement date of FEB2008
Stability › Weathertight Integrity › General
Issued 1 February 2006 Resolved
Provide proper means of closure of forward bridge window as per 46 CFR 177.1030.
Action required: 705 - Other - as specified
Due 17 March 2006
Resolved 17 March 2006
Resolution: Proper captive devices installed
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 1 February 2006 Resolved
Remove oil from bilge and machinery space as per 46 CFR 176.830
Action required: 705 - Other - as specified
Due 17 March 2006
Resolved 17 March 2006
Resolution: Oil removed.
Engineering › Steering Gear System › Hydraulic Hose
Issued 1 February 2006 Resolved
Repair leaks in hydraulic steering system located under operating station as per 46 CFR 176.830
Action required: 705 - Other - as specified
Due 17 March 2006
Resolved 17 March 2006
Resolution: Fittings tightened and leak stopped.
Construction/Loadline › Penetrations › Valve Flange
Issued 1 February 2006 Resolved
Repair/Renew and prove proper operation of live well sea suction valve as per 46 CFR 179.350.
Action required: 705 - Other - as specified
Due 17 March 2006
Resolved 17 March 2006
Resolution: Through hull replaced with new ball valve.
Engineering › Fuel Oil Service System › Filter
Issued 1 February 2006 Resolved
Provide metal plug for bottom of port main diesel engine fuel filter as per 46 CFR 182.455
Action required: 705 - Other - as specified
Due 17 March 2006
Resolved 17 March 2006
Resolution: Metal plug installed.
Engineering › Generator (propulsion-electric) › Wiring
Issued 1 February 2006 Resolved
Repair and prove operation of ship service generator.
Action required: 705 - Other - as specified
Due 17 March 2006
Resolved 17 March 2006
Resolution: Generator tested, sat.
Electrical › Lighting (service) › Lighting Fixture
Issued 1 February 2006 Resolved
Replace light cover starboard side main cabin fixture and use proper sized light bulb as per 46 CFR 183.410
Action required: 705 - Other - as specified
Due 17 March 2006
Resolved 17 March 2006
Resolution: Cover replaced and proper wattage light bulb installed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 February 2006 Resolved
Properly support wiring port side lazarette every 24 inches. 46CFR183.340
Action required: 705 - Other - as specified
Due 17 March 2006
Resolved 17 March 2006
Resolution: Wiring supported using proper bands.
Navigation › Piloting/Steering › US Coast Pilot
Issued 1 February 2006 Resolved
Provide on board vessel up-to-date U.S. Coast Pilot [name withheld], Tidal Current and Tide Table books as per 46 CFR 184.420
Action required: 705 - Other - as specified
Due 17 March 2006
Resolved 17 March 2006
Resolution: All publications were provided and found satisfactory.
Engineering › Diesel Engine (auxiliary) › Air Cleaner
Issued 1 February 2006 Resolved
Repair both main diesel engines where leaking and address the excess smoke coming out of the engines as per 46 CFR 176.830
Action required: 705 - Other - as specified
Due 17 March 2006
Resolved 17 March 2006
Resolution: Engines ran without smoking or excess oil leakage.
Fire Fighting › Fixed Halon Fire Extinguishing System › Control Valve
Issued 22 March 2005 Resolved
Ensure proper operation of starboard engine after discharge of fixed system IAW 46 CFR 181.420
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 March 2005
Resolution: Engines restarted after simulating fixed system discharge.
Lifesaving › Lifefloat › Float-free Link
Issued 22 March 2005 Resolved
Provide proper size weak link IAW 46 CFR 180.137
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 March 2005
Resolution: Proper weak link was installed.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 22 March 2005 Resolved
Secure waterlight to lifefloat IAW 46 CFR 180.175
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 March 2005
Resolution: Waterlight was attached around the body of the lifefloat and securd w/ splice.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 22 March 2005 Resolved
Renew expired eyewash and aspirin IAW 46 CFR 160.041
Action required: 705 - Other - as specified
Due 22 March 2005
Resolved 29 March 2005
Resolution: Eyewash and aspirin were renewed
Electrical › Electric Supply System (service) › Battery Conductor
Issued 15 March 2005 Resolved
Repair inoperable battery used for starboard MDE start, bilge pumps, navigation gear, etc. IAW 46 CFR 183.310
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 March 2005
Resolution: A new 8D battery was provided.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 28 February 2005 Resolved
Renew intermediate and cutlass bearing on port shaft.
Action required: 705 - Other - as specified
Resolved 1 March 2005
Resolution: Inspected installed intermediate and cutlass bearing-SAT.
Personnel › Manning/Qualifications › First Aid Certified Personnel
Issued 20 February 2004 Resolved
Provide red cross first aid/CPR cards for 50 % of crew IAW NVIC 1-91.
Condition: Unknown
Action required: 705 - Other - as specified
Due 23 March 2004
Resolved 1 July 2004
Resolution: Provided Red Cross first aid/CPR cards for crew.
Operations/Management › Drills/Instruction › Fire
Issued 20 February 2004 Resolved
Provide crew and perform man overboard and fire drills IAW 46 CFR 185.520.
Action required: 705 - Other - as specified
Due 23 March 2004
Resolved 1 July 2004
Resolution: Discussed fire and man overboard drills satisfactorily.
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 20 February 2004 Resolved
Prove proper operation of port main engine.
Action required: 705 - Other - as specified
Due 23 March 2004
Resolved 1 July 2004
Resolution: Port engine is operating properly.
Communications › Radio Communications › EPIRB
Issued 20 February 2004 Resolved
Install new hydrostatic release IAW 46 CFR 185.740.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 March 2004
Resolved 1 July 2004
Resolution: New hydrostatic release was provided.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 20 February 2004 Resolved
Make forward bulkhead of engine room vapor tight IAW 46 CFR 177.405(c).
Action required: 705 - Other - as specified
Due 23 March 2004
Resolved 1 July 2004
Resolution: Forward bulkhead of engine room vapor tight.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 20 February 2004 Resolved
Secure waterlight bracket for life float IAW 46 CFR 185.730.
Condition: Unknown
Action required: 705 - Other - as specified
Due 23 March 2004
Resolved 1 July 2004
Resolution: Waterlight bracket was secured.
Communications › Radio Communications › EPIRB
Issued 20 February 2004 Resolved
Provide proof of registration for EPIRB IAW FCC regulations. Vessel is limited to operating no more thatn three miles from shore.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 March 2004
Resolved 1 July 2004
Resolution: Provided proof of EPRIB registation.
Engineering › Sea-water System (primary cooling)
Issued 18 March 2003 Resolved
Replace generator sea suction hose with approved hose as per 46CFR 182.720(e)(2). LEGACY COMPONENT DESC: Piping
Condition: Improper Installation
Due 17 April 2003
Resolved 18 March 2003
Resolution: Sea suction hose was replaced with approved, reinforced hose.
Stability › Unintentional Flooding
Issued 18 March 2003 Resolved
Remove spare oil & water jugs from engine room bilge, as they were laying on top of the bilge high water level alarm.
Due 17 April 2003
Resolved 18 March 2003
Resolution: Jugs were removed from the engine room and owner/operator informed that fuel needs to be kept in the proper container not on top of the high water level alarm.
Communications › Radio Communications
Issued 18 March 2003 Resolved
Provide current FCC Marine Operators Permit as per 47CFR part 80.
Due 17 April 2003
Resolved 18 March 2003
Resolution: Operator provided proof of inspection and is awaiting reciept of FCC documentation.
Lifesaving › Lifejacket/PFD (General)
Issued 18 March 2003 Resolved
Replace retro reflective tape on ring bouy as per 46CFR 185.604(i). LEGACY COMPONENT DESC: Retroreflective Material
Due 17 April 2003
Resolved 18 March 2003
Resolution: Retro reflective tape was replaced on ring buoy.
Accommodation/Occupational Safety › Medical/First Aid
Issued 18 March 2003 Resolved
Provide current aspirin & eyewash for first aid kit as per 46CFR 184.710 & 160.041.
Due 17 April 2003
Resolved 18 March 2003
Resolution: Current Asprin and Eyewash was provided.
Construction/Loadline › Structures
Issued 23 January 2003 Resolved
Repair or renew fractured crippler frame in way of sewage tank. LEGACY COMPONENT DESC: framing
Action required: 705 - Other - as specified
Due 6 March 2003
Resolved 6 March 2003
Electrical › Electrical Distribution System (service)
Issued 23 January 2003 Resolved
Reattach exposed wires to switch in way of generator. LEGACY COMPONENT DESC: Wiring
Action required: 705 - Other - as specified
Due 6 March 2003
Resolved 6 March 2003
Lifesaving › Lifebuoys
Issued 31 January 2002 Resolved
Replace line on ring bouy lite with UV resistant line. LEGACY COMPONENT DESC: Buoyant Lifeline
Due 15 February 2002
Resolved 15 February 2002
Resolution: Inspected Line on bouy ring light and found it to be satisfactory.
Electrical › Electric Generation Source (service)
Issued 31 January 2002 Resolved
Repair leaking fuel oil line on generator. LEGACY COMPONENT DESC: Generator
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 February 2002
Resolved 15 February 2002
Resolution: Inspected fuel line on generator, Fuel line replaced with new CG approved flexible line.
Accommodation/Occupational Safety › Occupational Safety
Issued 31 January 2002 Resolved
Remove fuel from engine room bilge.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 February 2002
Resolved 15 February 2002
Resolution: Inspected engine room bilges and found them to be clean and free of fuel oil and debree.
Navigation
Issued 7 February 2001 Resolved
PROVIDE UPDATED CHARTS AND PUBLICATIONS AS REQUIRED BY 46 CFR 184.420
Condition: Unknown
Due 7 March 2001
Resolved 8 March 2001
Documentation
Issued 7 February 2001 Resolved
PROVIDE PROOF OF DRUG TESTING PROGRAM FOR CREW AS REQUIRED BY 46 CFR PART 16. CORRECT PRIOR TO CARRYING PASSENGERS FOR HIRE
Condition: Unknown
Due 8 February 2001
Resolved 12 February 2001
Lifesaving
Issued 7 February 2001 Resolved
INSTALL NEW BATTERY IN LIGHT FOR LIFEFLOAT AND REATTACH PAINTER TO BODY OF LIFEFLOAT AS REQUIRED BY 46 CFR 180.200(A)(2) _x001C_ CORRECT PRIOR TO CARRYING PASSENGERS FOR HIRE
Condition: Unknown
Due 7 March 2001
Resolved 8 March 2001
Lifesaving
Issued 7 February 2001 Resolved
REPLACE LIFELINE ON RING BOUY AS REQUIRED BY 46 CFR 180.70
Condition: Unknown
Due 7 March 2001
Resolved 8 March 2001
Construction/Loadline
Issued 7 February 2001 Resolved
TIGHTEN SHAFT LOG AS REQUIRED BY 46 CFR 176.802(C)
Condition: Unknown
Due 7 March 2001
Resolved 8 March 2001
Electrical
Issued 7 February 2001 Resolved
ELECTRICALLY HARD WIRE IN THE FREEZER IN THE HEAD AS REQUIRED BY 46 CFR 183.340
Condition: Unknown
Due 7 March 2001
Resolved 8 March 2001
Electrical
Issued 7 February 2001 Resolved
REMOVE ALL DEAD ENDED CABLES AS REQUIRED BY 46 CFR 183.340
Condition: Unknown
Due 7 March 2001
Resolved 8 March 2001
Navigation
Issued 7 February 2001 Resolved
REPLACE PORT AND STBD LENS COVERS AS REQUIRED BY 46 CFR 183.420
Condition: Unknown
Due 7 March 2001
Resolved 8 March 2001
Navigation
Issued 7 February 2001 Resolved
PROVIDE PROOF THAT THE COMBINATION ANCHOR/MAST HEAD LIGHT MEET THE VISIBILITY REQUIREMENT OF THE 72 COLREGS (5 MILES) AS REQUIRED BY 72 COLREGS _x001C_ VESSEL RESTRICTED TO DAYLIGHT OPERATION ONLY UNTIL CORRECTED
Condition: Unknown
Due 7 March 2001
Resolved 8 March 2001
Navigation
Issued 7 February 2001 Resolved
REMOUNT STERN LIGHT TO CORRECT ANGLE AS REQUIRED BY 72 COLREGS _x001C_ VESSEL RESTRICTED TO DAYLIGHT OPERATION ONLY UNTIL CORRECTED
Condition: Unknown
Due 7 March 2001
Resolved 8 March 2001
Electrical
Issued 9 February 2000 Resolved
PROPERLY REPAIR ELECTRICAL WIRING IN ENGINE ROOM AS REQUIRED BY 46 CFR 183.
Condition: Unknown
Due 9 February 2000
Resolved 9 February 2000
Documentation
Issued 9 February 2000 Resolved
PROVIDE PROPER FCC DOCUMENTATION AS REQUIRED BY 47 CFR 80.
Condition: Unknown
Due 9 February 2000
Resolved 9 February 2000
Documentation
Issued 9 February 1998 Resolved
PROVIDE CERTIFICATE OF DOCUMENTATION IN ACCORDANCE WITH 46 CFR 67.7 AND _x001C_ 33 CFR 173.25.
Condition: Unknown
Due 9 February 1998
Resolved 9 February 1998
Electrical
Issued 9 February 1998 Resolved
SHOW PROPER OPERATION OF ELECTRICAL GENERATOR AS PER 46 CFR 176.804(C).
Condition: Unknown
Due 9 February 1998
Resolved 9 February 1998
Lifesaving
Issued 9 February 1998 Resolved
PROVIDE NEW HYDROSTATIC RELEASE FOR EPIRB AS PER 46 CFR 180.64.
Condition: Unknown
Due 9 February 1998
Resolved 9 February 1998
Accommodation/Occupational Safety
Issued 7 February 1997 Resolved
RENEW WASTED MSD TANK 30X30 MESH VENT SCREEN IAW 33 CFR 159.95 (a) (2).
Condition: Unknown
Due 7 March 1997
Resolved 7 March 1997
Navigation
Issued 7 February 1997 Resolved
PROVE PROPER OPERATION OF THE VESSEL'S STEERING, MACHINERY, ELECTRICAL AND NAVIGATIONAL SYSTEMS IAW 46 CFR 176.804, 176.814, 176.806 AND 176.816.
Condition: Unknown
Due 7 March 1997
Resolved 7 March 1997
Lifesaving
Issued 7 February 1997 Resolved
PROVIDE A EPIRB TEST LOG IAW 46 CFR 185.728.
Condition: Unknown
Due 7 March 1997
Resolved 7 March 1997
Lifesaving
Issued 7 February 1997 Resolved
RENEW WASTED LIFEFLOAT WATERLIGHT LANYARD IAW 46 CFR 180.137.
Condition: Unknown
Due 7 March 1997
Resolved 7 March 1997
Navigation
Issued 7 February 1997 Resolved
RENEW OR REPAIR FRACTURED PORT NAVIGATION LIGHT IAW COMDINST M16672.2.
Condition: Unknown
Due 7 March 1997
Resolved 7 March 1997
Construction/Loadline
Issued 7 February 1997 Resolved
RENEW WORN A/C SEA SUCTION VALVE.
Condition: Unknown
Due 7 March 1997
Resolved 7 March 1997
Documentation
Issued 9 February 1996 Resolved
RENEW OIL POLLUTION PLACARD.
Condition: Unknown
Due 9 February 1996
Resolved 9 February 1996
Lifesaving
Issued 9 February 1996 Resolved
RENEW RETRO TAPE ON ONE CHILD SIZE PFD AS DESIGNATED BY THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 9 February 1996
Resolved 9 February 1996
Fire Fighting
Issued 9 February 1996 Resolved
PROVE PROPER OPERATION OF MAIN ENGINE HALON AUTOMATIC SHUTDOWN.
Condition: Unknown
Due 9 February 1996
Resolved 9 February 1996
Electrical
Issued 9 February 1996 Resolved
PROVE PROPER OPERATION OF GENERATOR UNDER LOAD.
Condition: Unknown
Due 9 March 1996
Resolved 21 February 1996
Lifesaving
Issued 9 February 1996 Resolved
PERMENATLY ATTACH 60FT LINE TO RING BUOY AND SEAPAINTER TO LIFEFLOAT.
Condition: Unknown
Due 9 February 1996
Resolved 9 February 1996
Lifesaving
Issued 9 February 1996 Resolved
PROPERLY STENCILE LIFEFLOAT CAPACITY ON LIFEFLOAT IAW 46 CFR 185.30-5 (b).
Condition: Unknown
Due 9 February 1996
Resolved 9 February 1996
Electrical
Issued 9 February 1996 Resolved
PROVIDE DOCUMENTATION THAT GENERATOR HAS BEEN DERATED BY 20% AND PROPERLY INSTALL DATA PLATE IAW 46 CFR 183.10-5(f)(2)
Condition: Unknown
Due 9 February 1996
Resolved 9 February 1996
Navigation
Issued 9 February 1996 Resolved
PROVIDE PROPER SIZE BELL IAW 72 COLREGS ANNEX III 7.9 INCH OR 200MM.
Condition: Unknown
Due 9 February 1996
Resolved 9 February 1996
Lifesaving
Issued 9 February 1996 Resolved
RENEW EPIRB HYDROSTATIC RELEASE WITH CURRENT DATED/NON-EXPIRED DEVICE.
Condition: Unknown
Due 9 February 1996
Resolved 9 February 1996
Engineering
Issued 9 February 1996 Resolved
PROVIDE AND INSTALL WIRE REINFORCED HOSE ON GENERATOR SEA SUCTION.
Condition: Unknown
Due 9 February 1996
Resolved 9 February 1996
Electrical
Issued 9 February 1996 Resolved
PROVIDE, INSTALL AND PROVE PROPER OPERATION OF AMPERAGE, VOLTAGE AND FREQUENCY METERS FOR 110VAC GENERATOR, IAW 46 CFR 183.10-5(g).
Condition: Unknown
Due 9 February 1996
Resolved 9 February 1996
Accommodation/Occupational Safety
Issued 13 February 1992 Resolved
PROVIDE RAILS OF 36 INCHES AT THE COCKPIT.
Condition: Unknown
Due 13 February 1992
Resolved 13 February 1992
Accommodation/Occupational Safety
Issued 13 February 1992 Resolved
RENEW CRACKED WINDOWS IN LOUNGE AND PILOTHOUSE.
Condition: Unknown
Due 13 February 1992
Resolved 13 February 1992
Fire Fighting
Issued 13 February 1992 Resolved
MARK FIXED HALON SYSTEM PULLS IN PILOT HOUSE.
Condition: Unknown
Due 13 February 1992
Resolved 13 February 1992
Engineering
Issued 13 February 1992 Resolved
PROVIDE GUARDS FOR STARBOARD ENGINE AND GENERATOR IN ACCORDANCE WITH 46_x001C_ CFR 177.35-15(a).
Condition: Unknown
Due 13 February 1992
Resolved 13 February 1992
Accommodation/Occupational Safety
Issued 13 February 1992 Resolved
PROVIDE METAL TRASH CAN WITH LID IN ACCORDANCE WITH 46 CFR 177.30-7(d).
Condition: Unknown
Due 13 February 1992
Resolved 13 February 1992
Lifesaving
Issued 13 February 1992 Resolved
PROVIDE EPIRB IN ACCORDANCE WITH 46 CFR 180.40-1. UNTIL EPIRB PROVIDED VESSEL IS RESTRICTED TO COASTWISE ROUTE NMT 20 MILES FROM A HARBOR OF SAFE REFUGE.
Condition: Unknown
Due 13 February 1992
Resolved 13 February 1992
Accommodation/Occupational Safety
Issued 13 February 1992 Resolved
PROVIDE ESCAPE EXIT MARKINGS IN ACCORDANCE WITH 46 CFR 185.30-15.
Condition: Unknown
Due 13 February 1992
Resolved 13 February 1992
Construction/Loadline
Issued 13 February 1992 Resolved
PROVIDE RETAINING CHAIN FOR AFT WATERTIGHT HATCH.
Condition: Unknown
Due 13 February 1992
Resolved 13 February 1992
Lifesaving
Issued 13 February 1992 Resolved
PROVIDE 3 ADDITIONAL ORANGE AND 3 ADDITIONAL RED DISTRESS SIGNALS.
Condition: Unknown
Due 13 February 1992
Resolved 13 February 1992
Fire Fighting
Issued 14 February 1989 Resolved
INSTALL CG APPROVED STRUCTURAL INSULATION ON FORWARD ENGINE ROOM BULKHEAD.
Condition: Unknown
Due 14 February 1989
Resolved 14 February 1989
Construction/Loadline
Issued 14 February 1989 Resolved
LABEL BILGE SUCTION MANIFOLD.
Condition: Unknown
Due 14 February 1989
Resolved 14 February 1989
Accommodation/Occupational Safety
Issued 14 February 1989 Resolved
REPLACE ELECTRICAL CABLE ON ENGINE ROOM VENTILATION SHUTDOWNS WITH STAINLESS CABLE.
Condition: Unknown
Due 14 February 1989
Resolved 14 February 1989

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.