Documentation record
Registered dimensions (L × B × D)44.0 ft × 14.0 ft × 6.0 ft
Registered tonnagegross 24 / net 19
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBONNER YACHTS · WETUMPKA, AL, UNITED STATES · built 1988
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portSUNNY HILLS, FL
Endorsements, as the file codes themcw_un, fi, rec
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it24 - Simplified, Gross Ton
19 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 15
11 May 2023
Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7686043
28 March 2023
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7658387
7 April 2022
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7427202
24 March 2021
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7161893
1 March 2021
Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7146841
1 June 2020
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6971194
1 May 2019
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6675180
28 March 2019
Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6651911
14 November 2018
Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6580538
4 May 2018
Administrative Inspection · Deficiency Check · DAPI Audit · COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6169400
28 June 2017
Administrative Inspection · Simplified Stability Test
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6198419
6 December 2016
Administrative Inspection · Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6063561
28 April 2016
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5865637
15 March 2016
Deficiency Check · Administrative Inspection · DAPI Audit · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5833842
22 February 2016
Administrative Inspection · COI Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5819899
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 April 2022
Resolved
Inspect machinery in accordance with 46 CFR 176.804. Fuel line for generator is not of an approved type.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2022
Resolved 8 February 2024
Resolution: Pulled COI from vessel.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 7 April 2022
Resolved
Inspect watertight closures in accordance with 46 CFR 176.802. Mid deck hatch will not seat properly.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2022
Resolved 8 February 2024
Resolution: Pulled COI from vessel.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 1 June 2020
Resolved
Replace hydrostatic release unit for EPIRB. Vessel's HRU was found to be expired 05/20.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2020
Resolved 1 June 2020
Resolution: Owner replaced HRU with new one.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 May 2019
Resolved
Tighten shaft packing around starboard shaft seal.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2019
Resolved 1 June 2020
Resolution: Shaft seal was tightened.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 May 2019
Resolved
Provide appropriate lifejacket donning placard.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2019
Resolved 1 June 2020
Resolution: Provided correct life jacket donning placard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 May 2019
Resolved
Provide appropriate electrical bonding for fuel fill pipes for both fuel tanks.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2019
Resolved 1 June 2020
Resolution: Bonding wires were installed.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 1 May 2019
Resolved
Provide copy of FCC Station license.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2019
Resolved 1 June 2020
Resolution: FCC station license provided.
Electrical › Electric Generation Source (service) › Generator
Issued 31 May 2018
Resolved
Vessel is prohibited from using installed generator to supply power to vessel. (Generator has been verified disconnected by USCG inspector). Electrical plan has been submitted to MSC for approval.
Action required: 705 - Other - as specified
Due 31 July 2018
Resolved 8 February 2024
Resolution: Pulled COI from vessel.
Engineering › Shafting/Propeller Arrangements › Strut Bearing
Issued 22 March 2017
Resolved
Replace Port and STBD Cutless bearings.
Action required: 705 - Other - as specified
Due 29 March 2017
Resolved 28 March 2017
Resolution: Vessel replaced both cutlass bearings
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 14 February 2017
Resolved
Submit fuel tank design/construction plan to MSC for approval. Vessel currently has fiberglass fuel tanks wiich tank top has been cut off.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 April 2017
Resolved 5 May 2017
Resolution: Approved plans witnessed.
Documentation › Logs/Records › Drug Test Records
Issued 23 March 2016
Resolved
New crew member was not added to DAPI.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 March 2016
Resolved 24 March 2016
Resolution: Provided proof of new crewmember added to DAPI.
Navigation › Electronic Positioning › Radio Direction Finding Device
Issued 23 March 2016
Resolved
EPIRB battery expired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 March 2016
Resolved 24 March 2016
Resolution: New EPIRB purchased and registered.
Lifesaving › Hand Flares › Expired
Issued 23 March 2016
Resolved
Not enough flares for oceans route.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 March 2016
Resolved 24 March 2016
Resolution: Purchsed new red flares.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 23 March 2016
Resolved
Retro tape on some life vest are faded.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 April 2016
Resolved 28 April 2016
Resolution: Replaced worn retro tape with new.
Engineering › Fuel Oil Service System › Hose
Issued 23 March 2016
Resolved
Fuel and steering line needs overhead clamp installed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 April 2016
Resolved 28 April 2016
Resolution: Installed clamps on lines in laz.
Fire Fighting › Means of Escape › Corridors
Issued 23 March 2016
Resolved
Escape hatch needs latched so that it won't open on its own.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 April 2016
Resolved 28 April 2016
Resolution: Latch installed.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 23 March 2016
Resolved
FWD hatch over void was loose, needs tightened.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 March 2016
Resolved 23 March 2016
Resolution: Was repaired and tested during exam.
Electrical › Electric Supply System (service) › Cable
Issued 23 March 2016
Resolved
Dead end wires under operation console needs wire caps or removed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 April 2016
Resolved 28 April 2016
Resolution: Dead end wires were removed under console.
Operations/Management › Drills/Instruction › Not Conducted
Issued 23 March 2016
Resolved
New record of new crew member drills being conducted.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 April 2016
Resolved 28 April 2016
Resolution: Underway drills conducted with crew.
Electrical › Electric Supply System (service) › Cable
Issued 23 March 2016
Resolved
Outlet in E/R needs new cover.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 April 2016
Resolved 28 April 2016
Resolution: New outlet cover installed.
Engineering › Fuel Oil Service System › Filter
Issued 23 March 2016
Resolved
Racor filter needs plug on valve.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 April 2016
Resolved 28 April 2016
Resolution: Added plug to racor filter.
Engineering › Bilge Water Management System › Piping
Issued 23 March 2016
Resolved
Bilge piping in E/R that is not being used, needs plug.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 April 2016
Resolved 28 April 2016
Resolution: Plugged unused bilge pipe.
Fire Fighting › Fixed Halon Fire Extinguishing System › Tanks
Issued 2 March 2016
Resolved
Vessel did not have an approved fixed fire-fighting onboard. Vessel must have an approved fixed fire-fightining system IAW 46 CFR 181.400; this must be done prior to passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 March 2016
Resolved 28 April 2016
Resolution: Fixed system installed and working. Checked inspection paper work.