MAURY USCG vessel records Sign in
← All vessels

WILLIAM J. RUPP

WILLIAM J. RUPP is a 1988 passenger vessel (inspected). The Coast Guard has recorded 43 inspections since 1988, most recently in April 2024, along with 38 deficiencies.

Records from 1988 to 2024. Most recent: inspection, 26 April 2024.

Built
1988
Last inspected
26 April 2024
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

308624
Flag
UNITED STATES
—
Maury page id
psix-308624

Inspections, by type

…with no type recorded1
Years with a record 29 calendar years (1988–2024)
The 43 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it4 - Regulatory (Subpart C or D), Gross Ton
4 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 43

26 April 2024 Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7892261
29 March 2024 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7886891
13 July 2022 Internal Structural Exam · Annual Inspection · Hull Examination · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7471933
17 June 2021 COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7211980
2 July 2020 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6990280
24 June 2019 Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6717520
10 July 2018 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6474330
14 May 2018 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6422680
14 July 2017 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6204127
7 July 2016 COI Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5932903
31 March 2016 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5844358
8 May 2014 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4856330
13 December 2011 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4207388
6 July 2011 COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4071635
5 May 2008 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3199417
25 July 2007 Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3014022
29 June 2006 Deficiency Check · Hull Examination · COI Inspection · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2694148
4 June 2003 Hull Examination · Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1849956
4 June 2002 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1629313
17 May 2001 Re-Inspection · Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1410563
19 May 2000 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1443019
7 June 1999 Re-Inspection · Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 805171
6 July 1998 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 793641
7 May 1997 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1106709
25 March 1997 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 780842
25 March 1997 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1105562
5 August 1996 Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1089953
26 June 1996 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1240652
28 June 1995 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1193724
25 May 1995 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1184745
27 May 1994 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1326308
22 April 1994 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 859022
22 March 1994 Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1165335
31 August 1993 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1135854
4 June 1993 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 838377
14 April 1992 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1267776
20 May 1991 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 907074
20 May 1991 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 907428
22 April 1991 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 921073
31 July 1990 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 901007
12 July 1990 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 933002
17 April 1989 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1035174
9 May 1988 Initial Certification · Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1194194

Deficiency record · 38

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 29 March 2024 Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. The vessel missed its annual inspection. Vessel must undergo an inspection for certification prior to operations. 46 CFR 176.500(a)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 November 2024
Resolution: Vessel no longer intends to operate as an SPV. COI has been deactivated.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 13 July 2022 Resolved
The master shall conduct sufficient drills and give sufficient instructions to make sure that all crew members are familiar with their duties during emergencies that necessitate abandoning ship or the recovery of persons who have fallen overboard. Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information: Date of the drill and training; and General description of the drill scenario and training topics. No drills logged.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 July 2022
Resolved 19 July 2022
Resolution: Drills logged.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 13 July 2022 Resolved
The master shall conduct sufficient fire drills to make sure that each crew member is familiar with his or her duties in case of a fire. Each fire drill must include: Instruction in the use and location of fire alarms, extinguishers, and any other fire fighting equipment on board. Fire fighting drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information: Date of the drill and training; and general description of the drill scenario and training topics. No drills logged.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 July 2022
Resolved 19 July 2022
Resolution: Drills logged.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 July 2020 Resolved
A submersible electric bilge pump may be used as a power bilge pump required by Table 182.520(a) only on a vessel of not more than 19.8 meters (65 feet) in length carrying not more than 49 passengers, other than a ferry, provided that a positive shutoff valve is installed at the hull penetration. No valve installed at engine room electric submersible bilge pump hull penetration. Install valve at hull penetration prior to return to commercial service.
Action required: 705 - Other - as specified
Resolved 17 June 2021
Resolution: New valve installed, sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 June 2019 Resolved
Each ring life bioy on a vessel must be approved in accordance with 160.050. Ring life buoy plug is missing allowing water to enter.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2019
Resolved 8 July 2019
Resolution: A new life-ring buoy was installed on the vessel with a plug inserted.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 June 2019 Resolved
Each floating waterlight must have a lanyard of three feet to six feet. Waterlight did not have a lanyard.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2019
Resolved 8 July 2019
Resolution: A new lanyard measuring three to six feet has been installed on the vessel attached to the waterlight.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 June 2019 Resolved
Each floating waterlight must be attached to the lanyard with a corrosion resistant clip. Waterlight was attached to the lifeline not the life ring buoy.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2019
Resolved 8 July 2019
Resolution: A corrosion resistant clip was attached to the waterlight lanyard around the ring life buoy.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 24 June 2019 Resolved
A vessel must carry either a first aid kit approved under approval series 160.041 or a kit with equivalent contents. Contents of first aid kit were expired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2019
Resolved 8 July 2019
Resolution: A new first aid kit was purchased and installed onboard.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 24 June 2019 Resolved
Vessel must carry navigation charts, U.S. Coast Pilot [name withheld], Tide Tables, and Current Tables.Vessel was missing all charts and nautical publications.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2019
Resolved 8 July 2019
Resolution: A local chart was provided onboard. All other publications are avilable but not kept onboard due to intended voyage.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 June 2019 Resolved
A submersible electric bilge pump may be used provided that a positive shut-off valve is installed at the hull penetration. No valve at the thru-hull penetration.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 July 2019
Resolved 10 July 2020
Resolution: Reissued as new requirement during hull exam.
Personnel › Certificates/Documents/Licenses › License, Operator
Issued 14 July 2017 Resolved
Provide licensed operator.
Action required: 705 - Other - as specified
Due 31 May 2018
Resolved 10 July 2018
Resolution: Provided licensed operator.
Operations/Management › Drills/Instruction › Not Conducted
Issued 14 July 2017 Resolved
Conduct man overboard and fire drill in presence of Marine Inspector.
Action required: 705 - Other - as specified
Due 31 May 2018
Resolved 10 July 2018
Resolution: Conducted man overboard and fire drill.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 7 July 2016 Resolved
Vessels life ring is missing name and retro tape as required by 46CFR185.604 and IMO Resolution A.658(16) (incorporated by reference)
Action required: 705 - Other - as specified
Due 21 July 2016
Resolved 18 August 2016
Resolution: Vessles name and retro tape has been added to the life ring on board. SAT.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 7 July 2016 Resolved
Vessel must complete and log drills required by 46CFR 185.520 and 46CFR 185.524.
Due 21 July 2016
Resolved 18 August 2016
Resolution: Vessel rep has conducted drills with all operators and logged appropriately.
Fire Fighting › Fire Bucket › Quantity
Issued 7 July 2016 Resolved
Vessing is missing 01 fire bucket.
Due 21 July 2016
Resolved 18 August 2016
Resolution: Vessel has added 01 fire bucket and now has 03 as required.
Documentation › Certificates/Documents › Stability Letter
Issued 13 December 2011 Resolved
THE VESSEL'S OWNER/OPERATOR HAS NOT REQUESTED AN INITIAL OR UPDATED STABILITY LETTER OR HAS NOT CERTIFIED COMPLIANCE WITH THE REVISED STABILITY CRITERIA FOR ASSUMED AVERAGE WEIGHT PER PERSON (AAWPP) OF 185 POUNDS. TO VERIFY COMPLIANCE, A STABILITY TEST MUST BE COMPLETED. BASED UPON A WEIGHT RATIO CALCULATION, THE VESSEL'S CAPACITY IS THERFORE LIMITED TO: 16 PERSONS(PASSENGERS AND CREW)
Action required: 705 - Other - as specified
Due 1 June 2012
Resolved 14 March 2012
Resolution: At owner''s request, conducted weight ratio calculations and issued new stability letter.
Operations/Management › Drills/Instruction › Fire
Issued 1 August 2007 Resolved
Written fire fighting procedures not on board.
Condition: Unknown
Due 1 August 2007
Resolved 1 August 2007
Resolution: Written procedures provided. All SAT
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 25 July 2007 Resolved
Provide proper operation of fixed fire extinguishing system.
Condition: Improper Installation
Due 1 August 2007
Resolved 1 August 2007
Resolution: Witnessed proper operation. ALL SAT.
Engineering › Bilge Water Management System › Not Installed
Issued 25 July 2007 Resolved
Provide proper operation of bilge high level alarm.
Condition: Unknown
Due 1 August 2007
Resolved 1 August 2007
Resolution: Witnessed proper operation of bilge high level alarm. ALL SAT
Lifesaving › Lifebuoys › Serviceable
Issued 25 July 2007 Resolved
Replace lifebuoy with proper markings.
Condition: Unknown
Due 1 August 2007
Resolved 1 August 2007
Resolution: New lifebuoy replaced. ALL SAT.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 25 July 2007 Resolved
Written man overboard procedures on board.
Condition: Unknown
Due 1 August 2007
Resolved 1 August 2007
Resolution: Provided written man overboard procedures. ALL SAT.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 29 June 2006 Resolved
Provide proof that the vessel operator is enrolled in the consortium.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 July 2006
Resolved 10 July 2006
Engineering › Fuel Oil Service System › Filter
Issued 29 June 2006 Resolved
Provided and install F/O flame impedment bowl.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 July 2006
Resolved 11 July 2006
Lifesaving › Lifebuoys
Issued 11 June 2002 Resolved
Provide approved life ring buoy.
Due 11 June 2002
Resolved 11 June 2002
Documentation › Certificates/Documents
Issued 4 June 2002 Resolved
Provide state registration sticker.
Due 11 June 2002
Resolved 10 June 2002
Construction/Loadline
Issued 26 June 1996 Resolved
OPEN FOR INSPECTION AREAS OUTBOARD OF THE MAIN ENGINE ON THE PORT AND STARBOARD SIDE WHERE LIFTED AND COMPLETE PERMANENT REPAIR TO THE SATISFACTION OF AN ATTENDING COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 26 June 1996
Resolved 26 June 1996
Construction/Loadline
Issued 26 June 1996 Resolved
MAKE PERMANENT REPAIR TO THREE SMALL INDENTS ON THE OUTER HULL ABOVE THE WATERLINE.
Condition: Unknown
Due 26 June 1996
Resolved 26 June 1996
Accommodation/Occupational Safety
Issued 25 May 1995 Resolved
PERMANANTLY REPAIR HAND RAIL STANCION ON PORT SIDE, AFT OF LOADING STATION NO LATER THAN 15 JUNE, 1995.
Condition: Unknown
Due 25 May 1995
Resolved 25 May 1995
Lifesaving
Issued 25 May 1995 Resolved
PROVIDE ONE ADDITIONAL ADULT SIZE TYPE I PFD. ALSO, SEPARATE CHILD AND ADULT PFD'S.
Condition: Unknown
Due 25 May 1995
Resolved 6 June 1995
Navigation
Issued 25 May 1995 Resolved
MAKE OPERATIONAL STERN NAVIGATIONAL LIGHT.
Condition: Unknown
Due 25 May 1995
Resolved 6 June 1995
Documentation
Issued 25 May 1995 Resolved
PROVIDE CURRENT MASS. STATE REGISTRATION FOR VESSEL, NO LATER THAN 15 JUNE,1995.
Condition: Unknown
Due 25 May 1995
Resolved 25 May 1995
Documentation
Issued 25 May 1995 Resolved
PROVIDE CURRENT DRUG TESTING INFORMATION AND PROVE COMPLIANCE WITH 46 CFR PART 16.
Condition: Unknown
Due 25 May 1995
Resolved 25 May 1995
Fire Fighting
Issued 25 May 1995 Resolved
PROVIDE ADDITIONAL BI HAND PORTABLE FIRE EXTINGUISHER AS PER C.O.I.
Condition: Unknown
Due 25 May 1995
Resolved 6 June 1995
Lifesaving
Issued 25 May 1995 Resolved
REMOVE FROM VESSEL ALL EXPIRED PYROTECHNICS.
Condition: Unknown
Due 25 May 1995
Resolved 6 June 1995
Engineering
Issued 22 April 1994 Resolved
REPLACE FLEXIBLE HOSE TO MAIN ENGINE INTAKE BETWEEN SEA VALVE AND STRAINER.
Condition: Unknown
Due 22 April 1994
Resolved 22 April 1994
Documentation
Issued 4 June 1993 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 4 June 1993
Resolved 4 June 1993
Fire Fighting
Issued 12 July 1990 Resolved
BI FIRE EXTINGUISHER SHOWS SIGNS OF CORROSION. PROVIDE NEW OR REFURBISHED USCG APPROVED FIRE EXTINGUISHER.
Condition: Unknown
Due 12 July 1990
Resolved 12 July 1990
Lifesaving
Issued 12 July 1990 Resolved
VESSEL CERTIFICATED FOR 22 TOTAL PERSONS. ONLY 21 LIFE JACKETS PROVIDED VESSEL LIMITED TO 21 TOTAL PERSONS UNTIL ADDITIONAL LIFE PRESERVER PROVIDED
Condition: Unknown
Due 12 July 1990
Resolved 12 July 1990

Ownership record