THE MANHATTAN II

THE MANHATTAN II is a 1988 passenger vessel (inspected). The Coast Guard has recorded 82 inspections since 1988, most recently in July 2025, along with 130 deficiencies and 1 casualty investigation in 2007.

Records from 1988 to 2025. Most recent: inspection, 15 July 2025.

Built
1988
Last inspected
15 July 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDJ9810
308634
Flag
UNITED STATES
368001330, 368029640
Maury page id
psix-308634

Inspections, by type

…with no type recorded15
Years with a record 31 calendar years (1988–2025)
The 82 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)107.1 ft × 35.0 ft × 8.0 ft
Registered tonnagegross 87 / net 59
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMARINE BUILDERS, INC. · UTICA, IN, UNITED STATES · built 1988
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 4 February 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it87 - Regulatory (Subpart C or D), Gross Ton
59 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDJ9810MMSI 368029640 · active · compulsorily equipped · granted 28 March 2018, expires 28 March 2028
WDJ6897MMSI 368001330 · active · compulsorily equipped · granted 1 August 2017, expires 1 August 2027
WUW9157MMSI not assigned · expired · compulsorily equipped · granted 14 July 1998, cancelled 22 November 2008 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 82

15 July 2025 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8180953
29 June 2025 Deficiency Check · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8169688
20 February 2025 Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8081612
30 January 2025 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8072341
23 July 2024 Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7897385
8 July 2023 Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7736408
23 April 2023 COI Inspection · In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7672889
10 April 2023 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7666070
11 January 2023 In-Service Inspection · Deficiency Check · Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7614442
9 August 2022 Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7529011
26 May 2022 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7623313
28 January 2021 Plan Review (Other than "T") · Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7135720
6 January 2021 Hull Examination · Internal Structural Exam · Examination of Repairs · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7120271
12 August 2020 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7031189
6 July 2020 Plan Review (Other than "T")
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6998438
23 September 2019 Hull Examination · Internal Structural Exam · Administrative Inspection · Examination of Repairs
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6819071
26 June 2019 MTSA Verification · Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6725458
30 May 2019 Deficiency Check · In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6699662
19 March 2019 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6645048
10 April 2018 Deficiency Check · In-Service Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6388261
8 March 2018 Load Line/Change of Employment
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6368619
15 March 2017 Administrative Inspection · Initial Certification
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6121536
1 February 2010 Administrative Inspection
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3677004
13 May 2008 Deficiency Check · Re-Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3205604
20 December 2007 Damage Survey
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3119348
20 December 2007 Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3119467
8 March 2007 MTSA Verification · COI Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 2884715
4 May 2006 Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 2640464
5 April 2006 Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 2621192
23 March 2006 Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 2608241
23 March 2006 Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 2608286
21 March 2006 Security Plan Review - ASP
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 2606693
26 April 2005 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 2344325
1 February 2005 Hull Examination · Internal Structural Exam
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 2289726
3 September 2004 Administrative Inspection · Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 2185448
3 May 2004 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 2058062
30 March 2004 Deficiency Check · Periodic Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 2034522
30 March 2004 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 2071217
30 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1977849
15 April 2003 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1774710
12 March 2002 COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1601565
1 May 2001 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1064205
2 April 2001 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1366257
24 April 2000 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1049061
23 March 2000 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1406679
10 February 2000 Hull Examination
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1461243
22 December 1999 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1381756
18 August 1999 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 654643
8 August 1999 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 177447
13 July 1999 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 175261
20 April 1999 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 27488
24 March 1999 COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1411838
1 July 1998 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 794998
30 June 1998 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 654644
20 April 1998 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1452386
18 April 1998 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 33518
30 March 1998 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1466508
5 May 1997 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1101930
12 March 1997 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1464025
22 January 1997 Administrative
Administrative · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1104678
4 April 1996 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1079787
26 March 1996 COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1079013
10 January 1996 Hull Examination
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1189319
29 March 1995 COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1142131
18 April 1994 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1167281
30 March 1994 COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 856063
3 May 1993 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1440691
2 April 1993 COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1414126
11 February 1993 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1443353
14 July 1992 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 952086
1 April 1992 COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1254829
25 June 1991 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1220071
25 June 1991 Examination of Repairs · Plan Review "T" Boat
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1241253
24 April 1991 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 931618
23 April 1991 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1242993
18 April 1991 COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 920490
7 January 1991 Hull Examination
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1217490
10 May 1990 COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1224390
13 July 1989 COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1043694
7 April 1989 Hull Examination
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1044079
29 August 1988 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1043059
27 July 1988 Initial Certification
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1340671

Deficiency record · 130

07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 15 July 2025 Resolved
Doors in A-Class fire control boundaries must meet the following additional requirements: ... A door must be of the self-closing type capable of closing against a 3.5 list of the vessel. MIs observed the fire boundary port side door is not self-closing. Rectify within 14 days.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 July 2025
Resolved 25 July 2025
Resolution: Vessel submitted videos attesting to the rectification of the deficieny. They are attached to the documents tab.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 29 June 2025 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessel lost propulsion on both engines while underway. Vessel shall complete repairs, provide casual analysis and perform a sea trial in the presence of CG MI. 46 CFR 119.200(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 June 2025
Resolution: MIs conducted def check & sea trial and received causal analysis.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 23 July 2024 Resolved
"Vessels contracted for on or after July 1, 1961, which carry more than 150 passengers shall meet the requirements of subpart 72.05 of Subchapter H (Passenger Vessels) of this chapter." Fire boundary insulation installed in the engine room was noted as being worn and degraded. Replace insulation accordingly w/in 30 days. 46 CFR 177.10-5 OLD T
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 August 2024
Resolution: Vessel installed insulation over the sections that were missing.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 July 2024 Resolved
"The general construction of the vessel shall be such as to minimize fire hazards insofar as reasonable and practicable." Grease build-up was noted in the ventilation hood installed in the galley. Clean out grease w/in 14 days. 46 CFR 177.10-5 OLD T
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 August 2024
Resolution: galley hood cleaned
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 23 July 2024 Resolved
"Portable fire extinguishers shall be installed and located to the satisfaction of the Officer in Charge, Marine Inspection." 02 portable fire extinguishers located in the pump room and engine room were not mounted in a bracket. Rectify w/in 14 days. 46 CFR 181.30-10(b) "Old T"
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 August 2024
Resolution: Fire extinguisher bracket installed and replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 July 2024 Resolved
"Each ring life buoy must be of an approved type, constructed in accordance with subpart 160.050 of this chapter" Ring buoy mounted to the stern, 2nd deck was noted as having degraded retro-reflective tape and markings. Rectify w/in 14 days. .46 CFR 180.30-1(a) "Old T"
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 August 2024
Resolution: Lifebuoy marked and fitted with retro
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 July 2024 Resolved
"The ducts or piping shall be so arranged and supported to be capable of safely sustaining stresses induced by weight and engine vibration and to minimize transfer of vibration to the supporting structure." Air intake ducts supplying generator #2 and #3 was noted as being loose and not properly secured. Rectify w/in 14 days. 46 CFR 182.20-45 (b) "Old T"
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 August 2024
Resolution: Replaced and secured in place.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 23 July 2024 Resolved
"All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection." Lighting fixtures in the laz and engine room were noted as not being properly mounted. Rectify w/in 14 days 46 CFR 183.01-15 (a) "Old T"
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 September 2024
Resolution: Vessel Sent in Objective Evidence of the Light fixture being restored properly.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 23 July 2024 Resolved
"Where cable protection is carried through watertight decks or bulkheads, the installation shall be such that will insure the watertight integrity of the structure." Wire conduit directly aft of WT door on stbd side galley was noted as corroded through & allowing water ingress through the WT bulkhead. Submit repair proposal w/in 14 days. Once approved, you will have an additional 14 days 46 CFR § 183.10-20 (e) "Old T"
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 September 2024
Resolution: Vessel C/R wastages. Was not structural.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 10 April 2023 Resolved
This subchapter applies to each vessel of less than 100 gross tons that carries more than 150 passengers ... and that (1) carries at least one passenger for hire. A vessel to which this subchapter applies may not be operated without having on board a valid U.S. Coast Guard Certificate of Inspection. Starting on 11APR23, vessel must undergo a successful COI inspection prior to carriage of passengers due to COI expiration on 10APR23. 46 CFR 114.110(a), 46 CFR 115.100(a), 701c
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 April 2023
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 11 January 2023 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. A gasketed metallic coupling (Straub fitting) was installed to connect new bilge pipe to existing bilge pipe in the lazarette instead of welding. This is installation was not included in the original repair plan and is considered a temporary repair at this time. It must be replaced with an approved permanent repair prior to receiving next drydock credit. 46 CFR 115.700(a), 705c
Action required: 705 - Other - as specified
Resolved 23 April 2025
Resolution: Review documents "Straub Couplings Data Sheet" & "ISO 15837-8" under documents tab. Coupling meets/exceeds requirements.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 26 June 2019 Resolved
A fire pump must be capable of delivering a single hose stream from the highest hydrant at a pressure of 50 PSI. Vessels fire pump was incapable pf producing satisfactory pressure. 46 CFR 118.300
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 June 2019
Resolved 27 June 2019
Resolution: Recieved video of proper pump operation and correct pressure.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 26 June 2019 Resolved
Company policy and Letter of Regulatory compliance, EAP, list of enrolled employees were missing from vessels DAPI program. 46 CFR 16.201
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 June 2019
Resolved 27 June 2019
Resolution: Recieved pictures of proper DAPI documnets.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 26 June 2019 Resolved
Station bill must be posted on a vessel requiring more than 4 crew members on board. Vessels station bill needs to be updated to reflect all duties for all crewmembers on board. 46 CFR 122.514
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 July 2019
Resolved 11 July 2019
Resolution: Attended vessel Station bill was posted.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 26 June 2019 Resolved
A vessel must carry adequate and up to date charts. Vessels charts need to be up dated. 46 CFR 121.420
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 July 2019
Resolved 1 July 2019
Resolution: Recieved video of updated charts
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 26 June 2019 Resolved
Vessel must carry adequate and up to date light list. Vessel was missing light list. 46 CFR 121.420
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 July 2019
Resolved 11 July 2019
Resolution: New Light List on board
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 June 2019 Resolved
Clear air supply vents to Engine room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 July 2019
Resolved 11 July 2019
Resolution: Cleaned vents
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 26 June 2019 Resolved
Vessels CSO must have general knowledge through training on methods of conducting audits. Vessel's CSO has not conducted annual VSP audits. 33 CFR 104.210(5)(b)(vi)
Action required: 705 - Other - as specified
Due 3 July 2019
Resolved 11 July 2019
Resolution: Adudit and training complete
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 June 2019 Resolved
Company Security Officer must have general knowledge of VSP. Vessels CSO was unfamiliar with vessels current VSP. 33 CFR 102.210
Action required: 705 - Other - as specified
Due 3 July 2019
Resolved 11 July 2019
Resolution: Quizzed CSO on VSP. All SAT
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 June 2019 Resolved
A bilge suction must be fitted with a suitable strainer. Vessel was missing multiple strainers on bilge suction pipe. 46 CFR 119.510
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 July 2019
Resolved 11 July 2019
Resolution: Strainers were installed
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 June 2019 Resolved
Life buoys must be marked with retro-reflective material. Vessel's port side brdge wing life buoy was missing retro tape.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 July 2019
Resolved 1 July 2019
Resolution: Recieved picture of buoy with retro tape.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 May 2019 Resolved
AT LEAST ONE RING LIFE BUOY ON A VESSEL MUST BE FITTED WITH A FLOATING WATERLIGHT. THE VESSEL [name withheld] THAT THE VESSELS FLOATING WATERLIGHT HAD BEEN RENDERED INOPERABLE DUE TO BECOMING WATER LOGGED. 46CFR117.70(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 June 2019
Resolution: Light shown to be operational in photo/video.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 30 May 2019 Resolved
THERE SHALL BE NO ACCUMULATION OF OIL IN BILGES OR HAZARDOUS SITUATIONS ON A VESSEL. BOTH OF THE ROOMS CONTAINING MAIN ENGINES AND GENERATORS HAD A SIGNIFICANT AMOUNT OF OILY WATER IN THE BILGES AND THE STARBOARD SIDE BILGE HAD WHAT APPEARED TO BE A COLLECTION OF SPILLED COOLANT. ALL BILGES ARE TO BE CLEARED OF OILY WATER/OTHER SUBSTANCES AND CLEANED, AFTER CONCLUSION OF THE POLLUTION RESPONSE TEAM'S INVESTIGATION. "OLD T" 46CFR176.50
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 June 2019
Resolution: Bilges have had oil/water/coolant removed.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 30 May 2019 Resolved
NAVIGATION LIGHTS SHALL MEET UL 1104 STANDARDS AND MEET THE INLAND NAVIGATIONAL RULES AND REGULATIONS. THE VESSELS STARBOARD SIDE NAVIGATIONAL LIGHT WAS NOT UL1104 APPROVED. RECTIFY PRIOR TO TRANSITING DURING TIMES OF LIMITED VISIBILITY. 46CFR120.420
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 June 2019
Resolution: Light bulbs were replaced with UL1104 compliant.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 May 2019 Resolved
ALL ELECTRICAL SPLICES SHALL BE MADE IN JUNCTION BOXES. THE BILGE ALARM IN VOID #2 HAD AN OPEN SPLICE MADE IN THE AREA OF THE BILGE. "OLD T" 46CFR183.05-50(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 June 2019
Resolution: Splices were placed in junction boxes.
Documentation › Logs/Records › Drug Test Records
Issued 10 April 2018 Resolved
Prove enrollment in DAPI program with crew list, pre-employment testing and random testing.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2018
Resolved 23 April 2018
Resolution: Received documentation proving crew list received pre-employment testing and is enrolled in random test pool.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 10 April 2018 Resolved
Relabel all lifejackets with vessel name.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2018
Resolved 4 May 2018
Resolution: Verified all lifejackets were labeled with the vessel name and all accounted for.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 10 April 2018 Resolved
Label the P4 breaker on 2nd deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2018
Resolved 4 May 2018
Resolution: Verified the breaker panel on 2nd deck was properly labeled.
Electrical › Electric Generation Source (service) › Ground Detection
Issued 10 April 2018 Resolved
Install ground detection.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2018
Resolved 29 May 2018
Resolution: Verified installed ground detection.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 10 April 2018 Resolved
Provide eyewash and ammonia inhalants.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2018
Resolved 29 May 2018
Resolution: Verified unexpired contents of medical kit.
Documentation › Safety Management System › Master's Authority/Responsibility Documentation
Issued 10 April 2018 Resolved
Provide documentation to CG stating galley will not be used.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2018
Resolved 23 April 2018
Resolution: Received documentation that galley will not be in service on vessel.
Operations/Management › Vessel Activity › Other
Issued 18 August 2017 Resolved
Vessel shall not operate with passengers until vessel receives in zone inspection by USCG SECTOR NEW YORK.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 November 2017
Resolved 10 April 2018
Resolution: Received satisfactory NTZ inspection in Sector NY AOR.
Operations/Management › Vessel Activity › Other
Issued 18 August 2017 Resolved
Vessel shall not operate with passengers until work list (attached scanned into documents) has been cleared by a Coast Guard marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 November 2017
Resolved 10 April 2018
Resolution: Majority of worklist items complete; remaining items reissued in form of CG-835.
Operations/Management › Vessel Activity › Other
Issued 18 August 2017 Resolved
Prior to vessel departing stability rout (Rivers) vessel shall reeive Single Voyage Load Line Exemption.
Action required: 17 - Rectify deficiencies prior to departure
Due 18 November 2017
Resolved 5 January 2018
Resolution: Issued Single Voyage Load Line Exemption to expire 10FEB18.
Engineering › Pressure Vessel › Relief Valve
Issued 18 August 2017 Resolved
Vessel shall provide and install releif valve to pressure vessel located in the engine room.
Action required: 705 - Other - as specified
Due 19 August 2017
Resolved 18 August 2017
Resolution: Observed releif valve on pressure vessel in engine room.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 13 May 2008 Resolved
Make permanent repairs to fire doors located in stairways, doors don't close automatically when released.
Condition: Unknown
Due 20 May 2008
Resolved 28 May 2008
Resolution: Replaced magnetic switch with new.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 8 March 2007 Resolved
Contact local Coast Guard Office to schedule DAPI audit.
Due 8 April 2007
Resolved 26 April 2007
Resolution: Conducted DAPI Audit. O/O provided adequate proof of Consortium & EAP enrollment this date
Electrical › Electrical Distribution System (service) › Cable
Issued 8 March 2007 Resolved
Remove wire nuts under pilot house control station and replace with butt connectors.
Condition: Improper Installation
Due 8 April 2007
Resolved 6 April 2007
Resolution: Satisfactory repair.
Construction/Loadline › Hull › Side Shell
Issued 8 March 2007 Resolved
Make permanent repairs to hole in galley side shell, aft starboard side.
Condition: Damaged By Earlier Event
Due 8 April 2007
Resolved 6 April 2007
Resolution: Installed insert plate in side shell.
Engineering › Feedwater/Condensate Water System › Piping
Issued 8 March 2007 Resolved
Replace missing hose clamps on engine cooling/fresh water systems.
Condition: Improper Installation
Due 8 April 2007
Resolved 6 April 2007
Resolution: Replaced.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 8 March 2007 Resolved
Install blanks in electrical panels openings where breakers are not present.
Condition: Unknown
Due 8 April 2007
Resolved 6 April 2007
Resolution: Installed.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 8 March 2007 Resolved
Place fire stop material in hole on 2nd deck behind service bar.
Condition: Unknown
Due 8 April 2007
Resolved 6 April 2007
Resolution: Completed.
Engineering › Bilge Water Management System › Interface Detector
Issued 8 March 2007 Resolved
Replace/repair bilge alarm, starboard engineroom, under stbd shart.
Due 8 April 2007
Resolved 6 April 2007
Resolution: Repaired wiring to alarm.
Electrical › Electric Generation Source (service) › Generator
Issued 8 March 2007 Resolved
Repair electrical wire on #1 generator leading to water temp switch.
Condition: Unknown
Due 8 April 2007
Resolved 6 April 2007
Resolution: Repaired.
Engineering › Bilge Water Management System › Interface Detector
Issued 5 April 2006 Resolved
#1 Void high Water alarm sticking in the alarm position and not registering properly on the annunciator panel. Vessel O/O to prove proper operation of alarm and panel.
Due 5 May 2006
Resolved 4 May 2006
Personnel › Certificates/Documents/Licenses › Certificate, CPR Course Completion
Issued 5 April 2006 Resolved
O/O to prove that 50% of veesl personnel have CRP/First Aid Certification. Combined with other
Due 5 May 2006
Resolved 4 May 2006
Fire Fighting › Combustible Materials › Furniture/Furnishings
Issued 27 July 2004 Resolved
Remove from vessel recently constructed DJ booth from second deck forward.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 August 2004
Resolved 3 August 2004
Resolution: Booth removed from vessel.
Fire Fighting › Combustible Materials › Furniture/Furnishings
Issued 27 July 2004 Resolved
Provide to local OCMI copy of as built plans with original fire load calculations.
Action required: 705 - Other - as specified
Due 27 August 2004
Resolved 23 August 2004
Resolution: Vessel operator dropped off copies of plans and current fire load calculations. Vessel was built as T-L, prior to falling under new Sub K.
Fire Fighting › Combustible Materials › Primary Deck Coverings
Issued 27 July 2004 Resolved
Provide proof that recently installed carpet throughout vessel meets the Structural Fire Protection requirements contained within NVIC 9-97 CH1.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 August 2004
Resolved 3 August 2004
Resolution: Vessel operator provided test results that met requirments of NVIC 9-97 CH1.
Engineering › Bilge Water Management System › Hose
Issued 30 March 2004 Resolved
Remove all oily waste and residue from entire engine room bilge area.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2004
Resolved 3 May 2004
Resolution: Cleaned.
Engineering › Bilge Water Management System
Issued 30 March 2004 Resolved
Clean up hydraulic oil from deck below hydraulic pump.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2004
Resolved 3 May 2004
Resolution: Cleaned.
Engineering › Pressure Vessel
Issued 30 March 2004 Resolved
Clean paint off of data plate. LEGACY COMPONENT DESC: Marking and Stamping
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2004
Resolved 3 May 2004
Resolution: Removed paint from data plate.
Electrical › Electrical Distribution System (service)
Issued 30 March 2004 Resolved
Provide ground fault protection for electrical outlets in both shaft areas. LEGACY COMPONENT DESC: Outlet Box
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 April 2004
Resolved 3 May 2004
Resolution: Installed.
Electrical › Electrical Distribution System (service)
Issued 30 March 2004 Resolved
Provide ground fault protection for 2nd deck bar area. LEGACY COMPONENT DESC: Outlet Box
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 April 2004
Resolved 3 May 2004
Resolution: Installed.
Electrical › Lighting (service)
Issued 30 March 2004 Resolved
Provide light cover for stbd side overhead galley light. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2004
Resolved 3 May 2004
Resolution: Installed.
Electrical › Lighting (service)
Issued 30 March 2004 Resolved
Provide safety globe and cage for light fixture in aft steering. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2004
Resolved 3 May 2004
Resolution: Installed.
Electrical › Electrical Distribution System (service)
Issued 30 March 2004 Resolved
Remove all extension cords from vessel and provide u/l approved grounded power strips as needed. LEGACY COMPONENT DESC: Wiring
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 April 2004
Resolved 3 May 2004
Resolution: Removed extension cords and installed pwer strips.
Electrical › Electric Generation Source (service)
Issued 30 March 2004 Resolved
Re-attach electrical connection cover #2 generator set. LEGACY COMPONENT DESC: Metallic Enclosure/Frame
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2004
Resolved 3 May 2004
Resolution: secured cover.
Accommodation/Occupational Safety › Ventilation
Issued 30 March 2004 Resolved
Clean / degrease exhaust fan cage, blades, and louvers for galley fan.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2004
Resolved 3 May 2004
Resolution: Purchased and installed new fan.
Accommodation/Occupational Safety › Occupational Safety
Issued 30 March 2004 Resolved
Repair 2nd deck bar area dishwasher plug. LEGACY COMPONENT DESC: Portable Electric Equipment/Appliances
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2004
Resolved 3 May 2004
Resolution: Repaired plug.
Fire Fighting › Fire Main › Pressure
Issued 30 March 2004 Resolved
Provide new fire main pressure gauge.
Action required: 705 - Other - as specified
Due 1 April 2004
Resolved 30 March 2004
Resolution: Vessel installed new gauge later same day as inspection.
Fire Fighting › Emergency Fire Pumps
Issued 30 March 2004 Resolved
Prove proper fire pump system pressure @ 50 psi IAW 46 CFR 118.300(b). LEGACY COMPONENT DESC: Pressure
Action required: 705 - Other - as specified
Due 12 April 2004
Resolved 13 April 2004
Resolution: Observed 52 psi at pump with one station opened.
Operations/Management › Lifesaving
Issued 30 March 2004 Resolved
Replace faded / worn life jacket donning placards 3rd deck. LEGACY COMPONENT DESC: Op Readiness/Maintenance/Inspection
Action required: 705 - Other - as specified
Due 30 April 2004
Resolved 3 May 2004
Resolution: Perchased new placards.
Operations/Management › Drills/Instruction
Issued 15 April 2003 Resolved
Conduct Man Overboard Drill for Coast Guard Inspector. LEGACY COMPONENT DESC: Man Overboard Recovery
Due 15 April 2003
Resolved 30 March 2004
Resolution: Conducted SAT man overboard drill.
Lifesaving › Lifejacket/PFD (General)
Issued 5 April 2002 Resolved
REPLACE 10 DAMAGED/WORN ADULT PFD'S.
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 April 2002
Resolved 16 April 2002
Resolution: REPLACED WITH NEW.
Accommodation/Occupational Safety › Medical/First Aid
Issued 12 March 2002 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 12 April 2002
Resolved 16 April 2002
Documentation › Manuals/Policy Documentation
Issued 12 March 2002 Resolved
PROVIDE COPY OF CURRENT NAVIGATION RULES.
Action required: 705 - Other - as specified
Due 12 April 2002
Resolved 16 April 2002
Engineering › Diesel Engine (propulsion/auxiliary-electric)
Issued 12 March 2002 Resolved
REPLACE FAULTY PORT GENERATOR JACKET WATER TEMPERATURE GAUGE IN PLTHS.
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 April 2002
Resolved 16 April 2002
Electrical › Electrical Distribution System (service) › Junction Box
Issued 12 March 2002 Resolved
PROPERLY COVER JUNCTION BOX UNDER PLTHS CONSOLE.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 April 2002
Resolved 16 April 2002
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 12 March 2002 Resolved
PLUG OPEN KNOCK OUT OPENINGS IN DISTRIBUTION PANEL IN PLTHS.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 April 2002
Resolved 16 April 2002
Electrical › Electric Generation Source (emergency)
Issued 12 March 2002 Resolved
CLEAN OIL SOAKED WINDINGS ON PORT GENERATOR SET.
Action required: 705 - Other - as specified
Due 12 April 2002
Resolved 16 April 2002
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 12 March 2002 Resolved
REPLACE INOPERATICE GFCI BREAKER PORTSIDE OF GALLEY.
Action required: 705 - Other - as specified
Due 12 April 2002
Resolved 16 April 2002
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 March 2002 Resolved
PROPERLY SEAL 2ND DECK BAR AREA DECK PENETRATION.
Action required: 705 - Other - as specified
Due 12 April 2002
Resolved 16 April 2002
Electrical › Lighting (emergency) › Lighting Fixture
Issued 12 March 2002 Resolved
REPAIR/REPLACE INOPERATIVE EMERGENCY LIGHT 2ND DECK PORTSIDE AFT.
Action required: 705 - Other - as specified
Due 12 April 2002
Resolved 16 April 2002
Electrical › Electric Generation Source (service) › Switch
Issued 12 March 2002 Resolved
REPLACE STBD GENSET J/W TEMPERATURE ALARM SENSOR.
Action required: 705 - Other - as specified
Due 12 April 2002
Resolved 16 April 2002
Accommodation/Occupational Safety › Cooking Systems
Issued 12 March 2002 Resolved
FIELD DAY GALLEY, TO ELIMINATE SANITATION ISSUES.
Action required: 705 - Other - as specified
Due 12 April 2002
Resolved 12 April 2002
Resolution: GALLEY SANITATION TO BE RECHECKED BY MARINE INSPECTOR PRIOR TO PREPARING/SERVING FOOD ITEMS FROM GALLEY.
Operations/Management › Drills/Instruction
Issued 12 March 2002 Resolved
POST MAXIMUM ALLOWED PASSENGER PLACARD FOR ALOHA DECK AS INDICATED ON STABILIY LETTER.
Action required: 705 - Other - as specified
Due 12 April 2002
Resolved 16 April 2002
Electrical › Electrical Distribution System (service)
Issued 12 March 2002 Resolved
CROP AND RENEW WASTED ELECTRICAL DECK PENETRATIONS IN ALOHA BAR AREA.
Due 12 April 2002
Resolved 16 April 2002
Fire Fighting › Structural Fire Protection - General
Issued 12 March 2002 Resolved
PROPERLY ADJUST FIRE DOOR SECOND {2nd} DECK AFT.
Action required: 705 - Other - as specified
Due 12 April 2002
Resolved 16 April 2002
Engineering › Bilge Water Management System
Issued 12 March 2002 Resolved
REPLACE FAULTY BILGE ALARM IN AFT GALLEY VOID.
Action required: 705 - Other - as specified
Due 12 April 2002
Resolved 16 April 2002
Electrical
Issued 2 April 2001 Resolved
REPAIR CABLE JACKET ON SHORE POWER CABLES.
Condition: Unknown
Due 2 April 2001
Resolved 2 April 2001
Engineering
Issued 2 April 2001 Resolved
REPAIR, REPLACE DEFECTIVE BATTERY CHARGING GAUGE ON BRIDGE.
Condition: Unknown
Due 2 April 2001
Resolved 2 April 2001
Electrical
Issued 2 April 2001 Resolved
CLEAN OIL SOAKED WINDINGS ON PORT AND STBD GENERATORS.
Condition: Unknown
Due 2 April 2001
Resolved 2 April 2001
Engineering
Issued 2 April 2001 Resolved
EFFECT PERMENANT REPAIRS TO STBD MAIN PROPULSION OUTBOARD MAIN PROPULSION DIESEL ENGINE MOUNT.
Condition: Unknown
Due 3 April 2001
Resolved 1 May 2001
Electrical
Issued 23 March 2000 Resolved
PROVIDE ACCEPTABLE MOUNTING AND ELECTRICAL PLANS TO THE LOCAL OCMI FOR CHANDELIER.
Condition: Unknown
Due 23 March 2000
Resolved 23 March 2000
Lifesaving
Issued 23 March 2000 Resolved
REMOVE ALL PLASTIC TRASH CANS AND REPLACE WITH METAL CANS.
Condition: Unknown
Due 23 March 2000
Resolved 23 March 2000
Electrical
Issued 23 March 2000 Resolved
REMOVE ALL MULTIPLE OUTLET ELECTRICAL ADAPTORS AND PROVIDE U.L. RATED OUTLETS AS NEEDED THROUGHGOUT VESSEL.
Condition: Unknown
Due 23 March 2000
Resolved 23 March 2000
Electrical
Issued 23 March 2000 Resolved
SORT OUT WIRES AND HARDWIRE THOSE ITEMS IN THE VICINITY OF BIG SCREEN ON_x001C_ MAIN DECK.
Condition: Unknown
Due 23 March 2000
Resolved 23 March 2000
Electrical
Issued 23 March 2000 Resolved
UPDATE AND PROVIDE ELECTRICAL CIRCUIT LEGENDS FOR ALL ELECTRICAL PANELS.
Condition: Unknown
Due 23 March 2000
Resolved 23 March 2000
Lifesaving
Issued 23 March 2000 Resolved
MAINTAIN ALL LOGS IN ACCORDANCE WITH 46 CFR SUBCHAPTER "K" TO INCLUDE SAFETY CHECKS, MAINTENANCE OF FIRE FIGHTING/SAFETY GEAR AND DRILLS.
Condition: Unknown
Due 23 March 2000
Resolved 23 March 2000
Fire Fighting
Issued 23 March 2000 Resolved
REPLACE ALL FIRE NOZZLES AT ALL FIRE STATIONS WITH COAST GUARD APPROVED NOZZLES.
Condition: Unknown
Due 23 March 2000
Resolved 23 March 2000
Fire Fighting
Issued 23 March 2000 Resolved
MAKE FIRE DOOR OPERATIONAL AT 2ND DECK AFT LOCATION.
Condition: Unknown
Due 23 March 2000
Resolved 23 March 2000
Fire Fighting
Issued 23 March 2000 Resolved
PROVIDE AN EMERGENCY ACTION AND FIRE CONTROL PLAN IN ACCORDANCE WITH 46 CFR116.530 AND 122.510 AND 514.
Condition: Unknown
Due 23 March 2000
Resolved 23 March 2000
Electrical
Issued 23 March 2000 Resolved
PROVIDE DEDICATED ELECTRICAL POWER SOURCE AND HARDWIRE THE BREAD STEAM OVENAND SECURE FROM MOVEMENT.
Condition: Unknown
Due 23 March 2000
Resolved 23 March 2000
Lifesaving
Issued 24 March 1999 Resolved
REMOVE PORTABLE ELECTRIC HEATERS FROM ALOHA BAR AREA.
Condition: Unknown
Due 24 April 1999
Resolved 1 April 1999
Engineering
Issued 24 March 1999 Resolved
DEMONSTRATE PROPER OPERATION OF INSTALLED ENGINE ALARMS.
Condition: Unknown
Due 5 April 1999
Resolved 1 April 1999
Construction/Loadline
Issued 24 March 1999 Resolved
PROPERLY SPLICE AND WIRE AUTOMATIC BILGE PUMPS IN PORT AND STBD SHAFT ALLEYS.
Condition: Unknown
Due 5 April 1999
Resolved 1 April 1999
Construction/Loadline
Issued 24 March 1999 Resolved
INSTALL BILGE HIGH LEVEL ALARMS IN ACCORDANCE WITH 46CFR119.530.
Condition: Unknown
Due 5 April 1999
Resolved 1 April 1999
Construction/Loadline
Issued 24 March 1999 Resolved
INSTALL INDICATOR LIGHT IN OPERATING STATION THAT ILLUMINATES WHEN AUTOMATIC BILGE PUMPS ARE IN OPERATION.
Condition: Unknown
Due 5 April 1999
Resolved 1 April 1999
Electrical
Issued 24 March 1999 Resolved
PROPERLY SPLICE AND TERMINATE WIRING FOR ALOHA BAR VENTILATION FAN.
Condition: Unknown
Due 24 April 1999
Resolved 1 April 1999
Electrical
Issued 24 March 1999 Resolved
PROVIDE PROTECTIVE COVERING FOR FOUR TUBE FLUORESCENT LIGHTING FIXTURE IN ALOHA BAR AREA.
Condition: Unknown
Due 24 April 1999
Resolved 1 April 1999
Electrical
Issued 24 March 1999 Resolved
REMOVE OR PROPERLY TERMINATE DEAD-ENDED WIRING IN OVERHEAD 2ND DECK DINING AREA.
Condition: Unknown
Due 24 April 1999
Resolved 1 April 1999
Electrical
Issued 24 March 1999 Resolved
PROPERLY WIRE CONNECTIONS FOR BUFFET TABLE, MAIN DECK DINING AREA.
Condition: Unknown
Due 24 April 1999
Resolved 1 April 1999
Engineering
Issued 24 March 1999 Resolved
MAKE AIR RECEIVER AVAILABLE FOR INTERNAL INSPECTION.
Condition: Unknown
Due 5 April 1999
Resolved 1 April 1999
Lifesaving
Issued 20 April 1998 Resolved
THE WHEELCHAIR LIFT ON THE MAIN DECK SHALL NOT BE USED UNTIL SAFE OPERATINGPROCEDURES HAVE BEEN INCORPORATED & PROMINENTLY DISPLAYED, AND THE LIFT ANDREQUIRED SAFETY DEVICES HAVE BEEN INSPECTED/TESTED IN THE PRESENCE OF A GOAST GUARD INSPECTOR AND VERIFIED TO BE IN ACCORDANCE WITH ASME A17.1.
Condition: Unknown
Due 20 April 1998
Resolved 20 April 1998
Lifesaving
Issued 20 April 1998 Resolved
PROVE INTENDED PURPOSE OF ELECTRICAL JUNCTION BOX ON WHEELCHAIR LIFT PLATFORM; RESTORE TO INTENDED PURPOSE OR PROPERLY DEAD-END THE CABLES AFTERCOORDINATING THE RESOLUTION WITH THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 20 April 1998
Resolved 20 April 1998
Electrical
Issued 12 March 1997 Resolved
REMOVE THE DEAD-END ELECTRICAL CABLE LAYING TRANSVERSE IN THE CRAWL SPACE FORWARD OF THE THIRD DECK STACK HOUSE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 March 1997
Resolved 12 March 1997
Electrical
Issued 12 March 1997 Resolved
REPLACE THE PILOT HOUSE WIPER MOTOR WITH ONE HAVING A TWO WIRE ELECTRICAL SYSTEM._x001C_ _x001C_
Condition: Unknown
Due 12 March 1997
Resolved 12 March 1997
Electrical
Issued 12 March 1997 Resolved
REPLACE VARIOUS WIRE NUTS ON THE FOOD SERVICE EQUIPMENT ELECTRICAL SYSTEM WITH COMPRESSION TYPE FITTINGS.
Condition: Unknown
Due 12 March 1997
Resolved 12 March 1997
Fire Fighting
Issued 26 March 1996 Resolved
Effect permanent repairs to both fire screen doors leading to the galley. Ensure door closes flush with the frame.
Condition: Unknown
Due 4 April 1996
Resolved 4 April 1996
Electrical
Issued 26 March 1996 Resolved
Make permanent wire splices per 46 CFR 183 to the wire connections on the refrigeration compressors in the aft steering and pantry voids.
Condition: Unknown
Due 4 April 1996
Resolved 4 April 1996
Accommodation/Occupational Safety
Issued 30 March 1994 Resolved
REPAIR THE DRAIN PIPE ON THE STARBOARD SIDE OF THE TOP DECK ROOF._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 March 1994
Resolved 30 March 1994
Lifesaving
Issued 30 March 1994 Resolved
PROVIDE 4 ADULT LIFE PRESERVERS FOR A TOTAL OF 540. TOTAL PERSONS ALLOWED IS REDUCED TO 536 UNTIL COMPLETED._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 March 1994
Resolved 30 March 1994
Engineering
Issued 30 March 1994 Resolved
REPAIR LEAKING VALVE ON THE LUBE OIL STORAGE TANK._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 March 1994
Resolved 30 March 1994
Engineering
Issued 30 March 1994 Resolved
REPAIR LEAK IN HYDRAULIC SHIFTER CONTROL ON THE PORT MAIN DIESEL ENGINE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 March 1994
Resolved 30 March 1994
Engineering
Issued 30 March 1994 Resolved
REPACK STUFFING TUBE ON STARBOARD SHAFT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 March 1994
Resolved 30 March 1994
Lifesaving
Issued 30 March 1994 Resolved
PROVIDE 13 CHILD SIZE LIFE PRESERVERS FOR A TOTAL OF 54. TOTAL CHILDREN ALLOWED IS REDUCED TO 41 UNTIL COMPLETED._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 March 1994
Resolved 30 March 1994
Engineering
Issued 30 March 1994 Resolved
REAIR OIL LEAKS IN THE NUMBER 1 AND 2 SHIP SERVICE GENERATORS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 March 1994
Resolved 30 March 1994
Fire Fighting
Issued 30 March 1994 Resolved
REPAIR THE AUTOMATIC CLOSURE ON THE FIRE SCREEN DOOR, ON THE PORT SIDE OF_x001C_ THE STAIRWAY ON THE MAIN DECK._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 March 1994
Resolved 30 March 1994
Lifesaving
Issued 2 April 1993 Resolved
PROVIDE SEPARATE STORAGE FOR CHILDREN LIFE PRESERVERS SEPARATE FROM ADULT LIFE PRESERVERS._x001C_ _x001C_ 46 CFR 180.25-10(C)
Condition: Unknown
Due 2 April 1993
Resolved 2 April 1993
Fire Fighting
Issued 2 April 1993 Resolved
PROPERLY LABEL AND NUMBER EACH FIRE STATION WITH 2 INCH RED LETTERING._x001C_ _x001C_ _x001C_ MARINE SAFETY MANUAL VOL. II CHAPTER 18.C.10
Condition: Unknown
Due 2 April 1993
Resolved 2 April 1993
Accommodation/Occupational Safety
Issued 1 April 1992 Resolved
MAKE PERMANENT REPAIRS TO PVC DRAIN LINE LEAK IN AFTER VOID, AS REQUIRED BY46 C.F.R. 182.40-1(A)(4)
Condition: Unknown
Due 1 April 1992
Resolved 1 April 1992
Navigation
Issued 18 April 1991 Resolved
Conduct underway drills; maneuvering, man overboard, fire, and abandon shipas required by 46CFR185.25-10 prior to compliance date.
Condition: Unknown
Due 18 April 1991
Resolved 18 April 1991
Deck/Cargo
Issued 18 April 1991 Resolved
Clean flame screens to fuel oil tank vents as required by _x001C_ 46CFR182.20-35(d).
Condition: Unknown
Due 18 April 1991
Resolved 18 April 1991
Construction/Loadline
Issued 18 April 1991 Resolved
Provide secure cover to #4 void as required by 46CFR171.124(b)(1) prior to compliance date.
Condition: Unknown
Due 18 April 1991
Resolved 18 April 1991
Electrical
Issued 18 April 1991 Resolved
Secure electrical wiring in electrical plugs for fans in galley and bar on bridge deck, and in outlet for port ice machine in space forward of bar on bridge deck as required by 46CFR183.05-45(e) prior to compliance date.
Condition: Unknown
Due 18 April 1991
Resolved 18 April 1991
Electrical
Issued 18 April 1991 Resolved
Secure cover to electrical shore tie box on stern of vessel prior to compliance date.
Condition: Unknown
Due 18 April 1991
Resolved 18 April 1991
Electrical
Issued 18 April 1991 Resolved
Provide cover to electrical outlet boxes to thermistats in all passenger spaces as required by 46183.05-50(b)(1) prior to compliance date.
Condition: Unknown
Due 18 April 1991
Resolved 18 April 1991
Accommodation/Occupational Safety
Issued 18 April 1991 Resolved
Reconnect PVC piping to deck drain in stern void prior to compliance date.
Condition: Unknown
Due 18 April 1991
Resolved 18 April 1991
Fire Fighting
Issued 27 July 1988 Resolved
PROVE PROPER OPERATION OF THE MAIN DECK FIRE DOORS PRIOR TO COMPLIANCE DATE
Condition: Unknown
Due 27 July 1988
Resolved 27 July 1988

Casualty record · 1

20 December 2007Routine · role: Involved in a Marine Casualty · activity 3119467
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

THE STAR (2007). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.