MAURY USCG vessel records Sign in
← All vessels

ROYALE

ROYALE is a 1974 passenger vessel (inspected). The Coast Guard has recorded 94 inspections since 1988, most recently in January 2024, along with 146 deficiencies — 12 with no resolution recorded — and 6 operational controls.

Records from 1988 to 2024. Most recent: inspection, 26 January 2024.

Built
1974
Last inspected
26 January 2024
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7350442 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
5IM313
308935
Flag
TANZANIA
—
Maury page id
psix-308935

Inspections, by type

…with no type recorded43
Years with a record 16 calendar years (1988–2024)
The 94 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it9511 - Convention (Subpart B), Gross Ton
9511 - Regulatory (Subpart C or D), Gross Ton
3479 - Convention (Subpart B), Net Ton
7159 - Displacement, Ton
1975 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 94

26 January 2024 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7856061
4 January 2007 Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2850190
4 January 2007 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2850240
10 August 2006 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2742313
25 July 2006 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2724196
4 April 2006 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2616400
6 October 2005 MTSA/ISPS Verification
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2508932
7 June 2005 Random ISPS/MTSA/PSC
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2382202
7 May 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2373983
5 May 2005 COC-CVE Annual · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2349892
28 April 2005 Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 2350685
27 April 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2343959
27 April 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2343999
26 April 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2343308
26 April 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2343857
25 April 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2342493
25 April 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2342973
25 April 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2343101
7 February 2005 COC-CVE Quarterly
Type not classified · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2288143
4 November 2004 COC-CVE Quarterly
Type not classified · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2234963
5 August 2004 COC-CVE Quarterly
Type not classified · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2157036
24 June 2004 ISPS II Exam
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2108876
13 May 2004 COC-CVE Annual
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2066375
29 April 2004 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2060502
29 April 2004 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2060510
29 April 2004 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2060601
29 April 2004 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2060606
27 April 2004 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2059689
3 February 2004 Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1999695
8 November 2003 Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1960617
25 September 2003 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1912526
18 August 2003 Administrative Inspection
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1879495
7 August 2003 Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1869373
2 July 2003 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1833852
22 May 2003 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1809403
2 May 2003 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1785012
2 May 2003 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1785017
29 April 2003 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1782989
28 March 2003 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1764645
18 December 2002 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1720745
6 July 2002 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1640917
8 March 2002 Passenger/Freight Vessel Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1492042
5 May 2001 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 49816
6 April 2001 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 288925
6 April 2001 Deficiency Check · Control Verification
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1065953
22 August 2000 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 281410
22 August 2000 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1052620
3 May 2000 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 145712
10 April 2000 Control Verification
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1381870
12 January 2000 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 273652
6 January 2000 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1468103
16 July 1997 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 723575
10 June 1997 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 404671
10 May 1997 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 403609
1 June 1993 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 838777
3 March 1993 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1399816
3 February 1993 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1466304
29 January 1993 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 828829
2 December 1992 Certificate of Compliance
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 829033
4 November 1992 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 960972
12 September 1992 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1257160
4 August 1992 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 949815
10 June 1992 Certificate of Compliance
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1254799
28 May 1992 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 483471
21 April 1992 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 350248
13 May 1991 Certificate of Compliance
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 900726
8 May 1991 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1230113
4 April 1991 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 903897
20 March 1991 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 931654
15 January 1991 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1231917
11 January 1991 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1225308
19 December 1990 Certificate of Compliance
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1237595
28 November 1990 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 922792
25 October 1990 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 908034
23 July 1990 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 986536
27 April 1990 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 337124
27 April 1990 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 909146
5 March 1990 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1224046
16 January 1990 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 918732
31 December 1989 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1229163
29 December 1989 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1232405
29 November 1989 Control Verification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 899440
26 November 1989 Damage Survey
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 901515
6 September 1989 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1206983
29 August 1989 Certificate of Compliance
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1348676
25 May 1989 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1030702
10 May 1989 Control Verification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1344108
4 May 1989 Control Verification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 888686
14 February 1989 Control Verification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1037441
15 December 1988 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 897752
28 October 1988 Control Verification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1203704
23 September 1988 Control Verification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1200187
26 May 1988 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 323625
26 May 1988 Control Verification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1193852

Deficiency record · 146

Documentation › Certificates/Documents › Certificate of Financial Responsibility
Issued 4 January 2007 Resolved
Vessel did not have a valid COFR onboard. The current COFR was for the previous management company. The new management company did not get a new one before acquiring management of the vessel.
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 January 2007
Resolved 4 January 2007
Resolution: Vessel issued a COFR number.
Pollution Prevention/Response › Prevention Equipment › Standard Discharge Connection
Issued 10 August 2006 No resolution recorded
Vessel must provide standard discharge connection to the satisfaction of USCG inspector.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Personnel › Certificates/Documents/Licenses › License, Second Mate
Issued 10 August 2006 No resolution recorded
Second officer has expired license. Vessel must provide valid license for crew member.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Personnel › Certificates/Documents/Licenses › License, Chief Engineer
Issued 10 August 2006 No resolution recorded
Chief Engineer does not have the original endorsement to his license. Vessel must provide original copy.
Action required: 17 - Rectify deficiencies prior to departure
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 10 August 2006 No resolution recorded
Conditions for food and catering found to be unsanitary. Rotting food found in provisions stores. Vessel must clean out stores and provide sanitary area to store food.
Action required: 15 - Rectify deficiencies by next port
Accommodation/Occupational Safety › Ventilation › General
Issued 10 August 2006 No resolution recorded
Conditions for food and catering has poor ventilation. Dirty ventilation screens, both intake and exhaust. Standing water and uninspected fire suppression system in the galley.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 10 August 2006 No resolution recorded
All crew accommodations were unsanitary and unsafe. No working toilets or hot and cold running water. Vessel must fix all utilities and clean crew accommodations.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 10 August 2006 No resolution recorded
Electrical apparatus' unsafely constructed in crew berthing areas. Almost all missing light covers. Vessel must repair all electrical hazards and provide all lighting with covers.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Lifesaving › Embarkation Appliances/Stations › Accessability
Issued 10 August 2006 No resolution recorded
#2 embarkation light is non-functional. Vessel must repair light to working condition.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 10 August 2006 No resolution recorded
Vessel has no Non-tank Vessel Response Plan. Vessel to draft and provide said plan.
Action required: 15 - Rectify deficiencies by next port
Documentation › Safety/Response Plans/Programs › Ballast Water Management Plan
Issued 10 August 2006 No resolution recorded
Ship has no Ballast Water Management Plan. Vessel to provide said plan.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Personnel › Certificates/Documents/Licenses › Medical Fitness Document
Issued 10 August 2006 No resolution recorded
Medical Certificates are missing for several crew members. Vessel to provide medical records for all crew.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Navigation › Piloting/Steering › Gyro Compass
Issued 4 April 2006 No resolution recorded
INOP Gyrocompass
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Fire Fighting › Automatic Sprinkler System
Issued 5 May 2003 Resolved
Verify installation of proper sprinkler heads for the spaces they are protecting throughout the vessel. LEGACY COMPONENT DESC: Sprinklers
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2003
Fire Fighting › Automatic Sprinkler System
Issued 5 May 2003 Resolved
Provide sufficient and proper sprinkler heads for each zone covered. LEGACY COMPONENT DESC: Spare Sprinkler Heads
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2003
Fire Fighting › Structural Fire Protection - General
Issued 5 May 2003 Resolved
Provide approved structural fire protection plans for the following decks: one, three and five.
Due 8 August 2003
Resolved 8 August 2003
Fire Fighting › Miscellaneous Items
Issued 5 May 2003 Resolved
Provide standard fire locker keys throughout the vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2003
Fire Fighting › Means of Escape
Issued 5 May 2003 Resolved
Provide emergency lighting and signage for plumbing in bos'n stores.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2003
Fire Fighting › Means of Escape
Issued 5 May 2003 Resolved
Emergency exit from the engine room needs insulation, signage up and down (emergency exit, do not block) and a lock from the inside. LEGACY COMPONENT DESC: Escape Route Signs
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2003
Fire Fighting › Automatic Sprinkler System
Issued 5 May 2003 Resolved
Make permanent and proper repairs to sprinkler piping in way of the liquor locker, deck #3. LEGACY COMPONENT DESC: Piping
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2003
Fire Fighting › Means of Escape
Issued 5 May 2003 Resolved
Provide security locks for all entrances and exits to all engineering spaces. LEGACY COMPONENT DESC: Doorways
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2003
Fire Fighting › Means of Escape
Issued 5 May 2003 Resolved
Provide signage indicating direction of emergency escape from the generator room. LEGACY COMPONENT DESC: Escape Route Signs
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2003
Fire Fighting › Means of Escape
Issued 5 May 2003 Resolved
Install means to prevent egress into dead end corridors. LEGACY COMPONENT DESC: Enclosed Stairway
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2003
Navigation › Piloting/Steering
Issued 5 May 2003 Resolved
Make permanent and proper repairs to the rudder angle indicating system. Provide a tech report attesting to the repairs. Prove proper operation of the steering system in the presence of a CG marine inspector.
Due 22 May 2003
Resolved 22 May 2003
Navigation › Piloting/Steering
Issued 5 May 2003 Resolved
Prove proper operation of the steering system in the presence of a CG marine inspector.
Due 30 May 2003
Resolved 8 August 2003
Navigation › Piloting/Steering
Issued 5 May 2003 Resolved
Provide an undated maneuvering fact sheet IAW the updated steering system..
Due 22 May 2003
Resolved 22 May 2003
Fire Fighting › Means of Escape
Issued 29 April 2003 Resolved
Have the flag state address the low location lighting throughout the vessel. Provide a class report approving the installation of the LLL IAW the manufacturers specifications. LEGACY COMPONENT DESC: Emergency Lighting
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2003
Fire Fighting › Structural - A Class Divisions
Issued 29 April 2003 Resolved
Ensure sequencers for all fire screen doors are in place and operating properly throughout the vessel. LEGACY COMPONENT DESC: Openings - Fire Doors
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2003
Fire Fighting › Structural - A Class Divisions
Issued 29 April 2003 Resolved
Have the following Fire Screen doors checked/adjusted for the passage of air while they are closed: 16, 31, 36, 43, 58 LEGACY COMPONENT DESC: Openings - Fire Doors
Due 30 May 2003
Resolved 22 May 2003
Fire Fighting › Structural - A Class Divisions
Issued 29 April 2003 Resolved
Make permanent and proper repairs/adjustments to the following Fire Screen Doors: 60: Sequencer 37, 38, 70, 75, 76: Adjust LEGACY COMPONENT DESC: Openings - Fire Doors
Due 30 May 2003
Resolved 22 May 2003
Fire Fighting › Miscellaneous Items
Issued 29 April 2003 Resolved
Trash cans throughout vessel are made of a combustible material. Provide trash cans of a non-combustible material or provide exemption from the certificate issuing authority. LEGACY COMPONENT DESC: Waste Receptacles
Action required: 705 - Other - as specified
Resolved 5 May 2003
Lifesaving › Embarkation Appliances/Stations
Issued 29 April 2003 Resolved
Tricing pennants for port lifeboats #4, 6, and 8 are too low. Make proper adjustments to the tricing pennants.
Action required: 705 - Other - as specified
Resolved 5 May 2003
Navigation › Emergency Steering
Issued 29 April 2003 Resolved
Provide line diagram for bridge IAW 33CFR164.35
Due 15 May 2003
Resolved 5 May 2003
Electrical › Electric Generation Source (emergency)
Issued 29 April 2003 Resolved
Label emergency fuel shut-off for the emergency generator.
Due 15 May 2003
Resolved 5 May 2003
Fire Fighting › Fire Hydrants
Issued 29 April 2003 Resolved
Fire Station #68 in the Engine Room is improperly piped into the sprinkler piping system. LEGACY COMPONENT DESC: Location/Position
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 May 2003
Navigation › Piloting/Steering
Issued 29 April 2003 Resolved
Rudder only goes from 30 degrees port to 30 degrees starboard instead of the required 35 to 35 in the emergency steering compartment. Provide indicator which will indicate 35 to 35 as required in SOLAS 60 Reg 29(b).
Action required: 705 - Other - as specified
Resolved 5 May 2003
Navigation › Electronic Positioning
Issued 29 April 2003 Resolved
EPIRB was not on board. LEGACY COMPONENT DESC: Radio Direction Finding Device
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 May 2003
Navigation › Collision/Grounding Avoidance
Issued 29 April 2003 Resolved
Gyro compass is not synchronized with the Radar. Radar is unable to acquire a track; Arpa is not functioning. Make proper repairs to collision avoidance systems. LEGACY COMPONENT DESC: Radar
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 May 2003
Fire Fighting › Means of Escape
Issued 29 April 2003 Resolved
Signage throughout the vessel is missing, not visible or improper positioned in way of fire equipment, muster stations, exit signs etc. Provide signage IAW Solas Resolutions. LEGACY COMPONENT DESC: Escape Route Signs
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2003
Lifesaving › Embarkation Appliances/Stations
Issued 29 April 2003 Resolved
Electrical boxes for lifeboat winch motors not watertight.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 May 2003
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 29 April 2003 Resolved
Elevator door to crew's mess is not closing properly. LEGACY COMPONENT DESC: Recreation Space
Due 15 May 2003
Resolved 5 May 2003
Electrical › Electrical Distribution System (service)
Issued 29 April 2003 Resolved
Electrical distribution boxes throughout vessel are missing breakers and spaces are not properly secured in them. Cover holes in boxes. LEGACY COMPONENT DESC: Distribution Panel Bus
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 May 2003
Fire Fighting › Means of Escape
Issued 29 April 2003 Resolved
Mark emergency escape from steering compartment to casino with "Emergency Exit" sign and "Do not block" sign LEGACY COMPONENT DESC: Escape Route Signs
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 May 2003
Fire Fighting › Structural Fire Protection - General
Issued 29 April 2003 Resolved
Provide draught stops in overhead in the card room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 May 2003
Electrical › Electrical Distribution System (service)
Issued 29 April 2003 Resolved
Switchboard in the engine room is missing covers to areas without breakers. LEGACY COMPONENT DESC: Switchboard
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 May 2003
Electrical › Electrical Distribution System (service)
Issued 29 April 2003 Resolved
Dead-ended cables throughout the vessel - Properly terminate or remove dead end cables in the following locations: trunk top in stuffing tube, Marcus lounge, fwd steering, A/C Room, bunker room, port side bridge wing, FSD #41, electrical box in stairway #4, storage room Deck 5 and the card room. LEGACY COMPONENT DESC: Cable
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 May 2003
Electrical › Lighting (emergency)
Issued 29 April 2003 Resolved
Provide emergency lighting in way of the emergency exit to the galley, deck #5. LEGACY COMPONENT DESC: Lighting Fixture
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2003
Electrical › Lighting (emergency)
Issued 29 April 2003 Resolved
Repair broken lights and provide emergency lighting for the emergency exit in the main laundry. LEGACY COMPONENT DESC: Lighting Feeder
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2003
Fire Fighting › Means of Escape
Issued 29 April 2003 Resolved
Provide a class report approving the installation of the Low location lighting IAW the manufacturers specifications. LEGACY COMPONENT DESC: Emergency Lighting
Due 8 August 2003
Resolved 22 May 2003
Documentation › Certificates/Documents › Certificate of Financial Responsibility
Issued 18 December 2002 Resolved
Invalid COFR
Due 31 December 2002
Resolved 31 December 2002
Resolution: COTP Order #80-02 has been rescinded.
Electrical › Electric Supply System (service)
Issued 8 March 2002 Resolved
Prior to next US port make repair to bridge shutdown of #3 fan room to the satisfaction of class. LEGACY COMPONENT DESC: Battery Installation Ventilation
Due 8 March 2002
Resolved 6 July 2002
Resolution: Class society, Bureau Veritas, verified an electrical coil in system was faulty and caused it to malfunction. The coil was replaced, the system was tested and functioned satisfactory.
Documentation
Issued 6 April 2001 Resolved
PROVIDE DOCUMENTARY EVIDENCE OF CROWD MANAGEMENT, FAMILIARIZATION, SAFETY TRAINING FOR PERSONNEL PROVIDING DIRECT SERVICE TO PASSSENGERS, & CRISIS MANAGEMENT & HUMAN BEHAVIOR TRAINING, FOR PROPER PERSONNEL IN ACCORDANCE WITH STCW CODE SECTION A-V/3 & PROVIDE CURRENT IMO CREW LIST & MUSTER LIST.
Condition: Unknown
Due 19 April 2001
Resolved 5 July 2001
Engineering
Issued 6 April 2001 Resolved
Realign self-closing devices on all deep tank sounding tubes - ensure counterweights close sounding tubes; attach threaded caps to tubes.
Condition: Unknown
Due 19 April 2001
Resolved 8 March 2002
Engineering
Issued 10 April 2000 Resolved
Repair fuel leaks on #1, #2, #3 & #4 MDE and permanantly pipe fuel return lines.
Condition: Unknown
Due 5 July 2000
Resolved 5 July 2000
Fire Fighting
Issued 10 April 2000 Resolved
Provide fire damper & insulation IAW SOLAS CH II-2/41.6.3 to existing exhaust duct from FR40 to FR115 on DK6 serving 3 seperate MVZ.
Condition: Unknown
Due 10 April 2000
Resolved 10 April 2000
Fire Fighting
Issued 10 April 2000 Resolved
Provide automatic bus transfer to sprinkler pump IAW SOLAS Reg 12. In the interum generator spaces are to be fully manned in order to manually switchbus transfer for sprinkler pump.
Condition: Unknown
Due 10 April 2000
Resolved 10 April 2000
Fire Fighting
Issued 10 April 2000 Resolved
Properly lable fire detection panel to correctly reflect:_x001C_ Fan room #8 deck 4 and fan room #9 deck 3.
Condition: Unknown
Due 10 April 2000
Resolved 10 April 2000
Fire Fighting
Issued 10 April 2000 Resolved
Prior to carrying passengers, remove sprinkler pump tank from generator room and install IAW SOLAS II Reg 12.
Condition: Unknown
Due 10 April 2000
Resolved 10 April 2000
Fire Fighting
Issued 10 April 2000 Resolved
Provide fire damper IAW SOLAS Ch II-2/41-6.3 in way of supply and exhaust ducting through MVZ step on DK3 from FR91 to FR60 on DK2
Condition: Unknown
Due 10 April 2000
Resolved 10 April 2000
Lifesaving
Issued 10 April 2000 Resolved
Prior to carrying provide approved launch apparatus for liferafts to the satisfaction of Class, IAW SOLAS 74/73/20-1.1.1 and NVIC 1-93.
Condition: Unknown
Due 10 April 2000
Resolved 10 April 2000
Construction/Loadline
Issued 12 January 2000 Resolved
OILY WATER SEPERATOR SOLENOID VALVE INOPERABLE.
Condition: Unknown
Due 22 August 2000
Resolved 22 August 2000
Lifesaving
Issued 10 June 1997 Resolved
PROVIDE GUARDS AROUND STEERING PUMP/MOTOR DRIVE SHAFT (BOTH PORT AND STARBOARD).
Condition: Unknown
Due 13 January 2000
Resolved 13 January 2000
Unknown
Issued 10 June 1997 Resolved
PROVIDE EFFECTIVE MEANS OF COMMUNICATING BETWEEN BRIDGE AND AFTER STEERING.
Condition: Unknown
Due 13 January 2000
Resolved 13 January 2000
Unknown
Issued 10 June 1997 Resolved
REMOVE OIL FROM DECK IN VICINITY OF STEERING PUMPS AND EMERGENCY STEERING CONTROLS IN AFTER STEERING. OIL MADE DECK SLIPPERY.
Condition: Unknown
Due 13 January 2000
Resolved 13 January 2000
Fire Fighting
Issued 10 June 1997 Resolved
CONDUCT OPERATIONAL TEST OF FIRE MAIN SYSTEM. PIPING SYSTEM LACKS INTEGRITY DUE TO ONGOING REPAIR WORK.
Condition: Unknown
Due 13 January 2000
Resolved 13 January 2000
Unknown
Issued 10 June 1997 Resolved
PROVIDE FLAG CONFIRMATION OF ADEQUATE MANNING IAW SAFE MANNING CERTIFICATE.MASTER PLANS ON OBTAINING 2 O/S FROM M/V ROYAL EMPRESS IF VESSEL NEEDS TO SAIL IN AN EMERGENCY.
Condition: Unknown
Due 13 January 2000
Resolved 13 January 2000
Lifesaving
Issued 10 June 1997 Resolved
REPAIR/REPLACE HOLED FUEL TANK AND LOOSE MIDDLE SEAT ON STARBOARD FOWARD LIFEBOAT.
Condition: Unknown
Due 22 August 2000
Resolved 22 August 2000
Navigation
Issued 10 May 1997 Resolved
PROVIDE CURRENT COMPASS DEVIATION TABLE AS REQUIRED BY 33 CFR 164.35(c).
Condition: Unknown
Due 22 August 2000
Resolved 22 August 2000
Fire Fighting
Issued 10 May 1997 Resolved
PROVE PROPER OPERATION OF MAIN FIRE PUMP. BAD BEARING IN MAIN FIRE PUMP NEEDS REPLACING PRIOR TO OPERATION.
Condition: Unknown
Due 10 June 1997
Resolved 11 June 1997
Accommodation/Occupational Safety
Issued 10 May 1997 Resolved
REPAIR INSULATION IN OVERHEAD OF PASSENGER LOUNGE. A-60 INSULATION MISSINGIN OVERHEAD OF AFT PORTION OF LOUNGE.
Condition: Unknown
Due 22 August 2000
Resolved 22 August 2000
Fire Fighting
Issued 10 May 1997 Resolved
RE-ORGANIZE FIRE LOCKERS. ATTACH AIR BOTTLES TO BREATHING APPARATUS._x001C_ EQUIPMENT IN FIRE LOCKERS WAS NOT STOWED TO BE EASILY ACCESSIBLE IN EMERGENCY SITUATIONS.
Condition: Unknown
Due 22 August 2000
Resolved 22 August 2000
Electrical
Issued 10 May 1997 Resolved
REPAIR/REPLACE WIRE TRANSIT ON DECK UNDER MSD CONTROLER FOR #3 MSD. WIRE TRANSIT NEEDS TO BE RESEALED.
Condition: Unknown
Due 22 August 2000
Resolved 22 August 2000
Engineering
Issued 10 May 1997 Resolved
PROVIDE CLASS DOCUMENTATION FOR ADEQUACY OF REPAIRS TO PORT AND STARBOARD AFT PEAK FILL PIPING. INSPECTOR NOTED 7 SOFT PATCHES ON FILL PIPING.
Condition: Unknown
Due 22 August 2000
Resolved 22 August 2000
Navigation
Issued 10 May 1997 Resolved
REPAIR INOPERABLE RUDDER ANGLE INDICATOR ON BRIDGE OVERHEAD AS REQUIRED BY 33 CFR 164.35(f).
Condition: Unknown
Due 13 January 2000
Resolved 13 January 2000
Navigation
Issued 10 May 1997 Resolved
PROVIDE CURRENT EDITION OF INLAND NAVIGATION RULES. VESSEL HAD 1983 EDITION ON BOARD.
Condition: Unknown
Due 13 January 2000
Resolved 13 January 2000
Navigation
Issued 10 May 1997 Resolved
REPAIR INOPERABLE ECHO DEPTH SOUNDER.
Condition: Unknown
Due 13 January 2000
Resolved 13 January 2000
Electrical
Issued 10 May 1997 Resolved
REPLACE GLOBES ON LIGHT FIXTURES IN STEERING GEAR ROOM. REPAIR STARBOARD FOWARD LIGHT FIXTURE IN STEERING GEAR ROOM.
Condition: Unknown
Due 13 January 2000
Resolved 13 January 2000
Lifesaving
Issued 10 May 1997 Resolved
CONDUCT FIRE AND ABANDON SHIP DRILLS TO THE SATISFACTION OF COAST GUARD INSPECTOR.
Condition: Unknown
Due 13 January 2000
Resolved 13 January 2000
Construction/Loadline
Issued 10 May 1997 Resolved
PROVIDE CLASS DOCUMENTATION FOR ADEQUACY OF PERMANENT REPAIRS TO STEM AT THE WATERLINE. STEM OF VESSEL WAS DAMAGED IN AZORES AND A TEMPORARY PLATE WAS WELDED ON FOR VOYAGE TO TAMPA, FL.
Condition: Unknown
Due 13 January 2000
Resolved 13 January 2000
Documentation
Issued 10 May 1997 Resolved
ALL SOLAS CERTIFICATES EXPIRED ON 08MAY97 BUT WERE ISSUED AS TEMPORARY FOR A ONE WAY VOYAGE TO TAMPA, FL.
Condition: Unknown
Due 13 January 2000
Resolved 13 January 2000
Fire Fighting
Issued 2 December 1992 Resolved
DURING ANNUAL EXAMINATION VESSEL HAD TO CONDUCT THREE FIRE DRILLS BEFORE THE ATTENDING MARING INSPECTORS FOUND THE DRILLS TO BE SAISFACTORY. VESSEL IS NOW REQUIRED TO CONDUCT ANOTHER FIRE DRILL BY 15 JANUARY 1993
Condition: Unknown
Due 2 December 1992
Resolved 2 December 1992
Fire Fighting
Issued 2 December 1992 Resolved
FIX P/S F/S DOORS FWD BROADWAY LOUNGE
Condition: Unknown
Due 2 December 1992
Resolved 2 December 1992
Fire Fighting
Issued 2 December 1992 Resolved
FIX F/S DOOR AT CORAL DK PORTSIDE POKER RM
Condition: Unknown
Due 2 December 1992
Resolved 2 December 1992
Accommodation/Occupational Safety
Issued 20 March 1991 Resolved
INSTALL A MEANS TO OPEN AND CLOSE EMERGENCY ESCAPE HATCHES FROM THE INSIDE_x001C_OF THE STABILIZER ROOM. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 March 1991
Resolved 20 March 1991
Unknown
Issued 20 March 1991 Resolved
INSTALL EXPLOSION PROOF GLASS COVER FOR THE OVERHEAD LIGHTS IN THE _x001C_ PAINT LOCKER. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 March 1991
Resolved 20 March 1991
Unknown
Issued 20 March 1991 Resolved
INSTALL AUDIBLE ALARM FOR THE 15 PPM OILY WATER SEPARATOR IN THE CONTROL _x001C_ ROOM AND STATION. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 March 1991
Resolved 20 March 1991
Unknown
Issued 19 December 1990 Resolved
CONDUCT FIRE AND ABANDON SHIP DRILL WITH FULL CREW COMPLEMENT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 December 1990
Resolved 19 December 1990
Unknown
Issued 19 December 1990 Resolved
PROVE PROPER INSTALLATION OF TWO -2- SEWAGE TANKS CLOSEST TO CREW'S GALLEY.
Condition: Unknown
Due 19 December 1990
Resolved 19 December 1990
Fire Fighting
Issued 25 October 1990 Resolved
FOLLOWING FSD'S DEFECTIVE: 2,3,4,11,18,FD 2-C, FD 3-C, 54,55.
Condition: Unknown
Due 25 October 1990
Resolved 25 October 1990
Fire Fighting
Issued 25 October 1990 Resolved
MANUAL SPRINKLER INSTRUCTIONS INADEQUATE.
Condition: Unknown
Due 25 October 1990
Resolved 25 October 1990
Documentation
Issued 25 October 1990 Resolved
WHEELHOUSE FIRE CONTROL PLAN NEARLY ILLEGIBLE.
Condition: Unknown
Due 25 October 1990
Resolved 25 October 1990
Deck/Cargo
Issued 25 October 1990 Resolved
CAR DECK - A-60 MISSING AFT OF MAIN LOUNGE (INSULATION) (PORT) - NEW PIPE PENETRATIONS.
Condition: Unknown
Due 25 October 1990
Resolved 25 October 1990
Deck/Cargo
Issued 25 October 1990 Resolved
CAR DECK - A-60 MISSING (INSULATION) OVERHEAD ABOVE SIDEPORT.
Condition: Unknown
Due 25 October 1990
Resolved 25 October 1990
Fire Fighting
Issued 25 October 1990 Resolved
FIRE STATION 48 BLOCKED WITH JUNK.
Condition: Unknown
Due 25 October 1990
Resolved 25 October 1990
Accommodation/Occupational Safety
Issued 25 October 1990 Resolved
REPAIR CTR HANDRAIL (LOWER STAIRS) GOING DOWN TO MAIN LOUNGE.
Condition: Unknown
Due 25 October 1990
Resolved 25 October 1990
Fire Fighting
Issued 25 October 1990 Resolved
NO MARKING, F. DAMPER WX DK, FS4, P&S.
Condition: Unknown
Due 25 October 1990
Resolved 25 October 1990
Electrical
Issued 25 October 1990 Resolved
NO E LIGHTS IN CO2 ROOM.
Condition: Unknown
Due 25 October 1990
Resolved 25 October 1990
Electrical
Issued 25 October 1990 Resolved
NO LOCAL ALARMS WHEN WT DOORS CLOSED FROM BULKHEAD DECK.
Condition: Unknown
Due 25 October 1990
Resolved 25 October 1990
Fire Fighting
Issued 25 October 1990 Resolved
RADIO ROOM FSD HAS HOLD-BACK HOOK.
Condition: Unknown
Due 25 October 1990
Resolved 25 October 1990
Fire Fighting
Issued 25 October 1990 Resolved
FOLLOWING FIRE DAMPERS ARE BEHIND LOCKED DOORS: A. P & S PURSER'S OFFICE B. LOCKER ACROSS FROM ROOM 201 D. STEWARD'S OFFICE C. HOSPITAL
Condition: Unknown
Due 25 October 1990
Resolved 25 October 1990
Fire Fighting
Issued 25 October 1990 Resolved
ALL FIRE DAMPERS MUST BE MARKED TO BE ABLE TO DETERMINE IF IT IS OPEN OR CLOSED.
Condition: Unknown
Due 25 October 1990
Resolved 25 October 1990
Electrical
Issued 31 December 1989 Resolved
DEMONSTRATE PROPER OPERATION OF FANS, LIGHTING AND CO2 FAN SHUTDOWN; TO THE SATISFACTION OF THE CLASSIFICATION SOCIETY PRIOR TO GETTING UNDERWAY.
Condition: Unknown
Due 31 December 1989
Resolved 31 December 1989
Electrical
Issued 31 December 1989 Resolved
MAKE PERMANENT REPAIRS TO DAMAGED FAN MOTOR CONTROLERS TO THE SATISFACTION OF THE LOCAL [name withheld] US PASSENGERS.
Condition: Unknown
Due 31 December 1989
Resolved 31 December 1989
Electrical
Issued 31 December 1989 Resolved
MAKE PERMANENT REPAIRS TO ALL DAMAGED ELECTRICAL WIRING IN FAN ROOM TO THE SATISFACTION OF THE LOCAL [name withheld] US PASSENGERS.
Condition: Unknown
Due 31 December 1989
Resolved 31 December 1989
Accommodation/Occupational Safety
Issued 29 November 1989 Resolved
REPAIR ELEVATOR TO DEMONSTRATE IT WILL STOP AT ALL DECKS. REPAIR INDICATORLIGHTS. RELABEL PUSH BUTTONS AND LIGHTS TO NEW DECK NAMES.
Condition: Unknown
Due 29 November 1989
Resolved 29 November 1989
Electrical
Issued 29 November 1989 Resolved
REPAIR A/C SUBSTATION CIRUIT BREAKER IN E/R MAINSBOARD.
Condition: Unknown
Due 29 November 1989
Resolved 29 November 1989
Fire Fighting
Issued 29 November 1989 Resolved
REPAIR SPRINKLER SYSTEM: A. SOFT PATCH SW PUMP ELBOW. B. LEAK ON TANK RELIEF VALVE. C. CORRECT ALARM/PRESSURE SET POINTS.
Condition: Unknown
Due 29 November 1989
Resolved 29 November 1989
Lifesaving
Issued 29 August 1989 Resolved
REMOVE ALL LIFEJACKETS FROM DECK BOXES AND DECK LOCKERS FOR INSPECTION.
Condition: Unknown
Due 29 August 1989
Resolved 29 August 1989
Documentation
Issued 29 August 1989 Resolved
CONTROL VERIFICATION EXAMINATION WAS COMPLETED ON 28AUG89. NEXT QUARTERLY EXAM DUE 28NOV89. CONTACT USCG PRIOR TO THIS DATE TO SCHEDULE THIS EXAM.
Condition: Unknown
Due 29 August 1989
Resolved 29 August 1989
Lifesaving
Issued 29 August 1989 Resolved
FREE NO. 3 LIFEBOAT WINCH BRAKE. BRAKE IS TO OPERATE WITH ITS OWN WEIGHT ONLY.
Condition: Unknown
Due 29 August 1989
Resolved 29 August 1989
Deck/Cargo
Issued 29 August 1989 Resolved
REPLACE MISISNG DOG TO DECK VENT. STBD FWD. FOREPEAK VENT.
Condition: Unknown
Due 29 August 1989
Resolved 29 August 1989
Fire Fighting
Issued 29 August 1989 Resolved
REPAIR OR REPLACE ALL FIREHOSE NOZZLES THAT FAIL TO SHUT OFF.
Condition: Unknown
Due 29 August 1989
Resolved 29 August 1989
Fire Fighting
Issued 10 May 1989 Resolved
PREPARE TO TEST 10-15 FIREHOSES AT NEXT EXAM.
Condition: Unknown
Due 10 May 1989
Resolved 10 May 1989
Construction/Loadline
Issued 10 May 1989 Resolved
#1 WATERTIGHT DOOR OPEN LEVER STICKS OPEN.
Condition: Unknown
Due 10 May 1989
Resolved 10 May 1989
Fire Fighting
Issued 10 May 1989 Resolved
FIREDOOR CLOSER, DOOR #11 BROKEN.
Condition: Unknown
Due 10 May 1989
Resolved 10 May 1989
Documentation
Issued 10 May 1989 Resolved
UPDATE MUSTER LIST FOR NEW EMPLOYEE NUMBERS.
Condition: Unknown
Due 10 May 1989
Resolved 10 May 1989
Construction/Loadline
Issued 10 May 1989 Resolved
#8 WATERTIGHT DOOR CANNOT OVERRIDE BRIDGE.
Condition: Unknown
Due 10 May 1989
Resolved 10 May 1989
Construction/Loadline
Issued 10 May 1989 Resolved
INSTALL ALL MISSING BOLTS AND GASKETS FOR 2 WATERTIGHT BOLTED DECK HATCHES OVER STEERING GEAR.
Condition: Unknown
Due 10 May 1989
Resolved 10 May 1989
Fire Fighting
Issued 10 May 1989 Resolved
RECOMMEND INSTALLATION OF FIRE DETECTION ALARM SYSTEM FOR PUMP ROOM, ENGINEROOM AND GENERATOR ROOM.
Condition: Unknown
Due 10 May 1989
Resolved 10 May 1989
Fire Fighting
Issued 14 February 1989 Resolved
OPERATE EMERGENCY FIRE PUMP FROM EMERGENCY GENERATOR.
Condition: Unknown
Due 14 February 1989
Resolved 14 February 1989
Construction/Loadline
Issued 14 February 1989 Resolved
WTD #6 WILL NOT OPEN LOCALLY AFTER BEING CLOSED FROM BRIDGE.
Condition: Unknown
Due 14 February 1989
Resolved 14 February 1989
Documentation
Issued 14 February 1989 Resolved
PROVIDE SERVICE CERTIFICATE FOR FIXED CO2 SYSTEM WITH STATEMENT THAT OPERATION OF PULL CABLE TO FIRST THREE (3) BANKS IS FREE AND WILL DISCHARGEALL BOTTLES.
Condition: Unknown
Due 14 February 1989
Resolved 14 February 1989
Documentation
Issued 14 February 1989 Resolved
CONTROL VERIFICATION EXAMINATION WAS COMPLETED ON 14FEB89. NEXT QUARTERLY EXAM DUE 04MAY89. CONTACT USCG TO SCHEDULE EXAM BY THIS DATE.
Condition: Unknown
Due 14 February 1989
Resolved 14 February 1989
Electrical
Issued 14 February 1989 Resolved
OPERATE GENERATOR SETTLER FUEL TANK REMOTE VALVE SHUT DOWN.
Condition: Unknown
Due 14 February 1989
Resolved 14 February 1989
Construction/Loadline
Issued 14 February 1989 Resolved
FIRE DOOR STBD SIDE FROM CAR DECK TO ACCOMMODATIONS DOOR WILL NOT CLOSE COMPLETELY.
Condition: Unknown
Due 14 February 1989
Resolved 14 February 1989
Electrical
Issued 14 February 1989 Resolved
CLEAN EMERGENCY BATTERY TRAYS.
Condition: Unknown
Due 14 February 1989
Resolved 14 February 1989
Accommodation/Occupational Safety
Issued 14 February 1989 Resolved
CONNECT LAUNDRY FAN TO BRIDGE REMOTE SHUTDOWN.
Condition: Unknown
Due 14 February 1989
Resolved 14 February 1989
Accommodation/Occupational Safety
Issued 14 February 1989 Resolved
DEMONSTRATE OPERATION OF ENGINE ROOM AND CAR DECK HEAT SECTION ALARM SYS.
Condition: Unknown
Due 14 February 1989
Resolved 14 February 1989
Electrical
Issued 14 February 1989 Resolved
OPERATE GENERATOR REVERSE POWER TRIP.
Condition: Unknown
Due 14 February 1989
Resolved 14 February 1989
Fire Fighting
Issued 14 February 1989 Resolved
PRESSURE TEST ALL EXTERIOR FIRE HOSE IN PRESENCE OF MARINE INSPECTOR.
Condition: Unknown
Due 14 February 1989
Resolved 14 February 1989
Engineering
Issued 14 February 1989 Resolved
THE SPRINKLER SYSTEM SEA SUCTION AND DISCHARGE VALVE ARE TO REMAIN OPEN AND POWER TURNED ON.
Condition: Unknown
Due 14 February 1989
Resolved 14 February 1989
Electrical
Issued 14 February 1989 Resolved
EMERGENCY GENERATOR AUTO START IS TO BE DEMONSTRATED. (GENERATOR APPEARS TOBE SLOW STARTING.)
Condition: Unknown
Due 14 February 1989
Resolved 14 February 1989
Electrical
Issued 14 February 1989 Resolved
FREE UP VENT LOUVERS TO EMERGENCY GENERATOR RADIATOR.
Condition: Unknown
Due 14 February 1989
Resolved 14 February 1989
Documentation
Issued 28 October 1988 Resolved
PROVIDE A LETTER FROM CLASS SOCIETY STATING THAT THE TEMPORARY SOURCE OF ELECTRIC POWER HAS THE CAPACITY FOR THE LOAD AND HAS BEEN CHECKED AND FOUNDSATISFACTORY PRIOR TO SAILING FOREIGN.
Condition: Unknown
Due 28 October 1988
Resolved 28 October 1988
Construction/Loadline
Issued 28 October 1988 Resolved
REPLACE MISSING DOG ON VENT CLOSURE PORT SIDE ON BRIDGE DECK AFT OF NO. 8 LIFEBOAT.
Condition: Unknown
Due 28 October 1988
Resolved 28 October 1988
Accommodation/Occupational Safety
Issued 28 October 1988 Resolved
RELACE VENTS PORT & STARBOARD. (AFTER PEAK COMP.)
Condition: Unknown
Due 28 October 1988
Resolved 28 October 1988
Electrical
Issued 28 October 1988 Resolved
REPAIR OR REPLACE EMERGENCY GENERATOR THERMOSTAT.
Condition: Unknown
Due 28 October 1988
Resolved 28 October 1988
Electrical
Issued 28 October 1988 Resolved
REPLACE THE EMERGENCY GENERATOR RADIATOR.
Condition: Unknown
Due 28 October 1988
Resolved 28 October 1988
Accommodation/Occupational Safety
Issued 28 October 1988 Resolved
PROVIDE PERMANENT VENTILATION FOR A/C POWER PANEL.
Condition: Unknown
Due 28 October 1988
Resolved 28 October 1988
Fire Fighting
Issued 28 October 1988 Resolved
CLEAR ALL OBSTRUCTIONS IN THE DRENCHER SPRINKLE SYSTEM AND PROVE SAME.
Condition: Unknown
Due 28 October 1988
Resolved 28 October 1988
Documentation
Issued 26 May 1988 Resolved
PROVIDE A POLLUTION PLACARD.
Condition: Unknown
Due 26 May 1988
Resolved 26 May 1988
Construction/Loadline
Issued 26 May 1988 Resolved
PRIOR TO THE VESSEL SAILING THE WATERTIGHT HATCH TO THE ENGINEROOM IS TO BESECURED AND MADE WATERTIGHT.
Condition: Unknown
Due 26 May 1988
Resolved 26 May 1988
Documentation
Issued 26 May 1988 Resolved
VESSEL'S REQUIRED NAUTICAL PUBLICATIONS ARE TO BE UP DATED WITH THE LATEST CHANGES.
Condition: Unknown
Due 26 May 1988
Resolved 26 May 1988
Fire Fighting
Issued 26 May 1988 Resolved
THE DRENCHER SPRINKLER SYSTEM IS TO BE TESTED WITH AIR IN THE PRESENCE OF A COAST GUARD INSPECTOR PRIOR TO 30 JUN88.
Condition: Unknown
Due 26 May 1988
Resolved 26 May 1988
Navigation
Issued 26 May 1988 Resolved
REPAIR STEERING GEAR POWER FAILURE ALARM TO THE #2 STEERING PUMP. VESSEL IS TO USE BOTH STEERING PUMPS WHEN ENTERING OR LEAVING PORT.
Condition: Unknown
Due 26 May 1988
Resolved 26 May 1988
Documentation
Issued 26 May 1988 Resolved
PROVIDE OIL TRANSFER PROCEDURE AS REQUIRED BY 33CFR155: BEFORE TRANSFERING FUEL.
Condition: Unknown
Due 26 May 1988
Resolved 26 May 1988

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.