07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 24 February 2025
Resolved
A pre-engineered fixed gas fie extinguishing system must be in compliance with 181.420. Original bottle designated for a compartment of 475 cubic foot was replaced with a smaller bottle designated for a compartment of 450 cubic foot. Coast Guard was not notified of change, and proof was not provided to show that compartment is smaller then 450 cubic foot.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 February 2025
Resolution: 500cu.ft bottle installed. Override test sat.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 24 February 2025
Resolved
A vessel on a limited coastwise route must carry six red distress flares and six hand orange smoke distress flares. Vessel missing 03 orange distress flares. Vessel route restricted to LBS/rivers route.
Action required: 705 - Other - as specified
Resolved 25 February 2025
Resolution: Provided.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 24 February 2025
Resolved
An EAP program must include the following elements: Supervisory personnel must receive at least 60 minutes of training. No proof of training provided.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2025
Resolved 25 February 2025
Resolution: Provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 February 2025
Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. Fwd compartment and E/R indicators are inoperable.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2025
Resolved 26 February 2025
Resolution: Tested sat.
01 - Certificates & Documentation › 013 - Documents › Garbage record book
Issued 24 February 2025
Resolved
The master or person in charge of a ship to which this section applies shall ensure a garbage management plan is on the ship and each person handling garbage follows the plan. Plan is missing.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2025
Resolved 25 February 2025
Resolution: Provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 February 2024
Resolved
On a vessel of at least 26' a visual and audible alarm must be provided at the operating station. V-Birth bilge alarm is INOP.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 February 2024
Resolved 9 February 2024
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 9 February 2024
Resolved
A vessel on which a pre-engineered system is installed must have an audible alarm that sounds upon discharge. Audible alarm INOP.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 February 2024
Resolved 9 February 2024
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 9 February 2024
Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC licensed Technician. FCC Safety Radiotelephony Certificate missing.
47 CFR 80.903
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 February 2024
Resolved 21 February 2024
Resolution: Received copy.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 9 February 2024
Resolved
Employers must ensure that they and their crewmembers meet the requirements of this part. Missing drug and alcohol consortium contract letter.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 February 2024
Resolved 13 February 2024
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 9 February 2024
Resolved
As appropriate for the intended voyage, a vessel must carry up-to-date charts. Charts not up-to-date.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 February 2024
Resolved 9 February 2024
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 9 February 2024
Resolved
A vessel must carry either a first-aid kit approved under 160.041 or a kit with equivalent contents. Kit missing aspirin.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 February 2024
Resolved 23 February 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 February 2024
Resolved
Flexible hose runs must be protected from damage. Fuel hose rubbing on potable water and fuel tank.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 February 2024
Resolved 9 February 2024
Resolution: Properly supported.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 8 February 2023
Resolved
Port side running light inoperable. Repair/replace light. Operations restricted to daylight only. 46 CFR 183.420
Action required: 705 - Other - as specified
Resolved 10 February 2023
Resolution: Light repaired.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 8 February 2023
Resolved
FCC Safety Certificate expired. Provide current certificate.
47 CFR 80.401
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 February 2023
Resolved 10 February 2023
Resolution: Current certificate provided.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 16 February 2022
Resolved
EPIRB's battery is expired. The EPIRB's battery is to be replaced after it is used, or before teh date required by FCC regulations in 47 CFR part 80, whichever comes sooner.
46 CFR 185.728
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 February 2022
Resolution: Battery replaced.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 16 February 2022
Resolved
Machinery space pre-engineered fixed gas fire extinguishing system bottle is not sufficiently charged. System to be fully charged. 46 CFR 181.420
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 February 2022
Resolution: Satisfactory fire system service report received; all SAT.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 16 February 2022
Resolved
Forward compartment bilge high level audible alarm inoperable. Repair alarm to allow operator to hear it when energized. 46 CFR 182.530
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 February 2022
Resolution: Alarm SAT.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 16 February 2022
Resolved
Machinery space bilge high level visual alarm inoperable. Repair alarm to allow operator to see visual alarm when energized. 46 CFR 182.530
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 February 2022
Resolution: Alarm SAT.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 16 February 2022
Resolved
Masthead light an starboard running light are inoperable. Prove proper operation of both lights. 46 CFR 183.420
Action required: 705 - Other - as specified
Resolved 21 February 2022
Resolution: Lights operate SAT.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 16 February 2022
Resolved
Main propulsion shaft's packing gland leaking excessively. Gland to be tightened to prevent excessive leakage.
46 CFR 176.830
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 February 2022
Resolution: Gland tightened to reduce amount of leakage.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 16 February 2022
Resolved
Fuel tank space watertight hatch missing securing device. Install securing device from hatch to vessel. 46 CFR 179.360
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 February 2022
Resolution: Securing device installed.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 15 September 2021
Resolved
Numerous soft spots found throughout hull while conducting hull soundings. Grind down all marked spots to find extent of water intrusion. Make repairs to the satisfaction of marine inspector prior to credit dry-dock. 46 CFR 176.610
Action required: 705 - Other - as specified
Resolved 5 October 2021
Resolution: Repairs completed SAT.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 September 2021
Resolved
Fuel return hose found to be cracked with non-approved type fittings. Replace hose with approved type and approved type fittings prior to credit dry-dock. 46 CFR 182.720(e)
Action required: 705 - Other - as specified
Resolved 17 September 2021
Resolution: Hose replaced SAT.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 September 2021
Resolved
Watertight compartment forward of machinery space is not provided with a functional arrangement for draining the compartment. Provide means for draining compartment in accordance with regulations prior to credit dry-dock.
46 CFR 182.500
Action required: 705 - Other - as specified
Resolved 29 September 2021
Resolution: Electrical submersible pump installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 September 2021
Resolved
Watertight compartment forward of crach bulkhead is not provided with a functional arrangement for draining the compartment. Ordinary leakage in this compartment may be removed by use of a hand portable bilge pump. Provide means for pumping this comparment prior to credit dry-dock.
46 CFR 182.510
Action required: 705 - Other - as specified
Resolved 29 September 2021
Resolution: Hand portable bilge pump provided.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 3 December 2020
Resolved
4 distress signals expired. Replace expired distress signals with current signals. 46 CFR 185.614
Action required: 705 - Other - as specified
Resolved 3 December 2020
Resolution: Distress signals replaced.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 3 December 2020
Resolved
Radio/EPIRB Safety Certificate not provided. Proved current certificate. 46 CFR 80.401
Action required: 705 - Other - as specified
Resolved 3 December 2020
Resolution: Certificate provided.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 12 February 2020
Resolved
Fuel tank space watertight hatch missing gasket and securing device. Install gasket to make watertight and install securing device. 46 CFR 179.360
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 February 2020
Resolution: Gasket and securing device installed.
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 12 February 2020
Resolved
Program MMSI number into radio. 47 CFR 80.13
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 February 2020
Resolved 13 February 2020
Resolution: MMSI number programmed into radio.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 February 2020
Resolved
Label life ring with vessel's name. 46 CFR 180.70
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 February 2020
Resolved 13 February 2020
Resolution: Life ring labeled.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 26 September 2019
Resolved
Leakage found at stbd through bolted strut. Repair leakage to the satisfaction of marine inspector prior to carrying passengers. Operational control issued.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 October 2019
Resolution: Repairs completed.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 18 September 2019
Resolved
Soft spot found on hull, port side aft below water line. Grind spot, submit lay-up schedule if needed and repair to the satisfaction of marine inspector prior to credit dry-dock. 46 CFR 176.610
Action required: 705 - Other - as specified
Resolved 2 October 2019
Resolution: Repairs completed.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 18 September 2019
Resolved
Approx. 1" depth by 12" long crack found along the corner of the top of keel at the hull, under propulsion shaft in fuel tank compartment. Submit repair proposal and make approved repairs prior to credit dry-dock. 46 CFR 176.610(b)
Action required: 705 - Other - as specified
Resolved 2 October 2019
Resolution: Completed repairs.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Bulwarks and freeing ports
Issued 18 September 2019
Resolved
Numerous cracks found in fiberglass at port and stbd transom bulwarks. Provide repair proposal and make repairs prior to credit dry-dock. 46 CFR 176.610
Action required: 705 - Other - as specified
Resolved 2 October 2019
Resolution: Repairs completed.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 18 September 2019
Resolved
Fiberglass delamination found at corner tabs aft side of collision bulkhead and outboard on bulkhead aft of collision bulkhead. Provide repair proposal and make repairs prior to credit dry-dock. 46 CFR 176.610(b)
Action required: 705 - Other - as specified
Resolved 2 October 2019
Resolution: Repairs completed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 September 2019
Resolved
Propulsion shaft bearing assembly in fuel tank space loose. Secure assembly prior to credit dry dock. 46 CFR 176.600
Action required: 705 - Other - as specified
Resolved 2 October 2019
Resolution: Shaft bearing assembly secured.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 18 September 2019
Resolved
Cut outs found in forward compt. watertight bulkheads. Secure open areas. 46 CFR 179.212
Action required: 705 - Other - as specified
Resolved 2 October 2019
Resolution: Open areas sealed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 September 2019
Resolved
Install valve handle on bilge piping at forward compartment watertight bulkhead penetration prior to credit dry-dock. 46 CFR 182.710
Action required: 705 - Other - as specified
Resolved 2 October 2019
Resolution: Handle installed.
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 18 September 2019
Resolved
Embarkation step loose. Secure step to ensure safe embarkation of passengers. 46 CFR 177.100
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 October 2019
Resolution: Step secured.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 20 February 2019
Resolved
Provide current FCC Station License. Restricted to no more than 1000 feet from shore. 46 CFR 80.13
Action required: 705 - Other - as specified
Resolved 22 February 2019
Resolution: Station license purchased
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 20 February 2019
Resolved
Install Class D GPS integrated radio or connect radio to GPS. Restricted to no more than 1000 feet from shore.
46 CFR 80.905
Action required: 705 - Other - as specified
Resolved 22 February 2019
Resolution: Radio connected to GPS.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 20 February 2019
Resolved
Program MMSI number into radio. 46 CFR 80.905
Action required: 705 - Other - as specified
Resolved 22 February 2019
Resolution: MMSI number programmed into radio.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 20 February 2019
Resolved
Tight loose mounting hardware for forwar rails. 46 CFR 177.900
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 March 2019
Resolved 26 February 2019
Resolution: Hardware tightened and rail secured.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 20 February 2019
Resolved
Install rail courses or equivalent at embarkation stations.
46 CFR 177.900
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 March 2019
Resolved 26 February 2019
Resolution: Courses installed.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 20 February 2019
Resolved
Hydro-statically test installed fire extinguisher bottle using certified technician. Complete at Dry-dock
46 CFR 181.410
Action required: 705 - Other - as specified
Resolved 2 October 2019
Resolution: In lieu of 12 year hydro for a clean agent system, visual examination is acceptable IAW 49 CFR 180.209(g)
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 20 February 2019
Resolved
Repair cracked bow platform. Complete at Dry-dock.
46 CFR 176.802
Action required: 705 - Other - as specified
Resolved 2 October 2019
Resolution: Platform repaired.
Communications › Radio Communications › EPIRB
Issued 23 February 2018
Resolved
Provided new hydrostatic release for epirb.
Due 26 February 2018
Resolved 23 February 2018
Resolution: Provided new hydro for epirb.
Stability › Watertight Integrity › General
Issued 23 February 2018
Resolved
Install hose back onto head discharge valve.
Due 26 February 2018
Resolved 23 February 2018
Resolution: Re-installed hose.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 23 February 2018
Resolved
Prove proper operation of ring buoy waterlight.
Due 23 February 2018
Resolved 23 February 2018
Resolution: Proved proper operation of waterlight.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 23 February 2018
Resolved
Update expired items in first aid kit.
Due 23 February 2018
Resolved 23 February 2018
Resolution: Items updated in first aid kit.
Construction/Loadline › Hull › Bottom Plating
Issued 10 October 2017
Resolved
Repairs various blisters on hull as discussed with CGMI.
Action required: 705 - Other - as specified
Resolved 30 October 2017
Resolution: All blisters have been repaired as per the approved repair plan.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 4 January 2016
Resolved
Provide EAP program.
Due 8 January 2016
Resolved 7 January 2016
Resolution: Owner has provided his employee assistance program. He had all along, but just did not have it for the day of inspection; he had recently had a captain quit that had taken care of this, so he just had to find out where the previous captain had the progra
Lifesaving › Lifefloat › Serviceable
Issued 4 January 2016
Resolved
Repair cracks in lifefloat with the approved repair kit.
Due 8 January 2016
Resolved 7 January 2016
Resolution: Owner has elected to place a Cat 1 406 epirb onboard vs repairing lifefloat. Vessel already had the 3 mile limitation on his COI.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 4 January 2016
Resolved
Add Kenneth Ward to crew list and provide updated crew list.
Due 7 January 2016
Resolved 7 January 2016
Resolution: Owner has added [name withheld] to crew list and provided new crew list.
Stability › Watertight Integrity › General
Issued 4 January 2016
Resolved
Prove proper operation of aft deck hatch. Hatch was very hard to actuate.
Due 13 January 2016
Resolved 13 January 2016
Resolution: Owner has hatch operating properly