MAURY USCG vessel records
← All vessels

PRIVATEER IV

PRIVATEER IV is a 1988 passenger vessel (inspected). The Coast Guard has recorded 22 inspections since 2016, most recently in April 2026, along with 77 deficiencies and 1 operational control.

Records from 2016 to 2026. Most recent: inspection, 30 April 2026.

Built
1988
Last inspected
30 April 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDA8016
309083
Flag
UNITED STATES
Maury page id
psix-309083

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspections, by type

Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Registered dimensions (L × B × D)89.8 ft × 25.0 ft × 7.9 ft
Registered tonnagegross 95 / net 64
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGULF CRAFT INC · PATTERSON, LA, UNITED STATES · built 1988
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portGLOUCESTER, MA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 5 September 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it95 - Regulatory (Subpart C or D), Gross Ton
64 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspection history · 22

30 April 2026 Internal Structural Exam · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8343959
15 October 2025 In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8248675
29 April 2025 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8107993
31 March 2025 Hull Examination · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8099577
2 December 2024 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8042105
22 April 2024 Annual Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7880777
17 April 2023 Annual Inspection · Administrative Inspection · Internal Structural Exam · Deficiency Check · In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7658480
15 November 2022 Hull Examination · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7591594
15 April 2022 COI Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7430337
28 April 2021 Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7184939
10 December 2020 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7110028
12 May 2020 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6951799
2 April 2020 Drydock Extension · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6934442
25 April 2019 Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6670299
10 September 2018 Administrative Inspection · Deficiency Check
Physical examination · Navigation Center · Activity 6537136
30 April 2018 Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6402958
11 April 2018 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6389348
29 March 2018 Drydock Extension
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6381036
20 February 2018 Drydock Extension · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6361493
20 March 2017 COI Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6106621
25 April 2016 Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5862636
11 February 2016 Hull Examination · Construction Oversight · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5814208

Deficiency record · 77

02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 29 April 2025 Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspections. Multiple lights in the engine room were found unlit when energized. 46 CFR 183.01-15(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2025
Resolved 5 May 2025
Resolution: Light bulbs were replaced and tested. All sat.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 29 April 2025 Resolved
An MMC must be retained by the mariner to whom it was issued and, while valid, must be produced to verify qualifications when requested by an authorized official. Licensed master's medical certificate is current but was not able to be produced at time of inspection. 46 CFR 10.203(b)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2025
Resolved 5 May 2025
Resolution: Operator provided objective evidence in the form of photograph showing medical cert was onboard and valid.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 April 2025 Resolved
Waste receptacles must be constructed of noncombustible materials with no openings in the sides or bottom. Waste receptacles on board were all combustible. 46 CFR 177.405(f)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2025
Resolved 5 May 2025
Resolution: Operator was able to provide objective evidence in the form of a video showing all trash receptacles were replaced with metal trash cans.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 29 April 2025 Resolved
At all inspections special attention shall be paid to insure that no fire hazards exist. The port generator had a moderate lube oil leak on the lube oil pressure gauge line. 46 CFR 176.25-10(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2025
Resolved 5 May 2025
Resolution: Operator was able to provide objective evidence in the form of a video showing gauge line lube oil leak was secured via plug and tested while running. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 April 2025 Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets. A container for adult life jackets was not placarded, and a placard for child life jackets was not conspicuously placed for the actual stowage location. 46 CFR 185.604(f)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2025
Resolved 5 June 2025
Resolution: Operator provided signage for both adult and child PFDs.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 29 April 2025 Resolved
When operating a vessel on a body of water where the discharge of untreated sewage is prohibited by the Environmental Protection Agency under 40 CFR 140.3, the operator must secure each Type III device in a manner which prevents discharge of sewage. Sewage overboard valves were not secured. 33 CFR 159.7(c)
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 29 April 2025
Resolution: Crew member locked the discharge valve with a nearby padlock normally used for the sewage discharge valve.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 April 2025 Resolved
Each battery used in an item of lifesaving equipment must be replaced during the annual inspection if the expiration date of the battery has passed. Battery for the floating waterlight was found expired. 46 CFR 185.726(d)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 29 April 2025
Resolution: Crew obtained new battery and installed it into the waterlight, which properly illuminated.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 29 April 2025 Resolved
Each survival craft must be stowed so that when the vessel sinks the surival craft floats free and, if inflatable, inflats automatically. Hydrostatic release unit for the starboard IBA was installed upside down and the painter line was not attached to the weak link. 46 CFR 180.130(a)(2)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 29 April 2025
Resolution: Crew reinstalled the hydrostatic release unit properly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 29 April 2025 Resolved
At all inspections special attention shall be pad to insure that no fire hazards exist. The intake vents on the vessel’s port and starboard generators had accumulated debris and dust. 46 CFR 176.25-10(b)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 29 April 2025
Resolution: Crew member cleaned the generator windings intake vents to MI satisfaction.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 17 April 2023 Resolved
Each survival craft must be secured to the vessel by a painter with a float-free link permanently attached to the vessel. Neither painter or HDRU were correctly installed to permit proper deployment.
Condition: Improper Installation
Action required: 30 - Ship detained
Due 17 April 2023
Resolved 19 April 2023
Resolution: Confirmed painter and HDRU were correctly installed.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 17 April 2023 Resolved
Each survival craft must be provided with means to prevent shifting. The port IBA’s strap which prevent shifting was not installed.
Condition: Improper Installation
Action required: 30 - Ship detained
Due 17 April 2023
Resolved 19 April 2023
Resolution: Confirmed the lashing was installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 April 2023 Resolved
Propulsion machinery shall be suitable in type and design for propulsion requirements of the hull in which it is install and capable of operating at constant marine load under such requirements without exceeding its design limitations. The starboard generator has a leak (approx. 1 drip per minute) which is splashing onto electrical wires. 46CFR182.05-1
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 17 April 2023
Resolved 19 April 2023
Resolution: Ran the generator and confirmed the leak was secured.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 17 April 2023 Resolved
Battery connections must be made to battery terminals with permanent type connectors. The port battery has a connection which is not permanent and can easily be lifted off the terminal without tools.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 17 April 2023
Resolved 19 April 2023
Resolution: Confirmed a new connection was installed and the permanently attached.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 17 April 2023 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces: (1) A space with a through-hull fitting below the deepest load waterline, such as a laz and (2) A space with a non-watertight closure, such as a space with a non-watertight hatch on the main deck. No visual or audible alarms were operable in the pilot house for the forepeak and lazarette spaces.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 17 April 2023
Resolved 19 April 2023
Resolution: Confirmed both alarms were operable.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 17 April 2023 Resolved
Each vessel that operates on the high seas must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. The EPIRB’s registration is expired.
Action required: 30 - Ship detained
Due 17 April 2023
Resolved 19 April 2023
Resolution: Verified the registration was submitted.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company verification, review and evaluation
Issued 17 April 2023 Resolved
The master of the vessel shall ensure that each EPIRB is tested monthly, using the integrated text circuit and output indicator, to determine that it is operative. The EPIRB test shall be logged or otherwise documented as applicable. The operator was unfamiliar with how to perform the tests and unable to provide evidence of a test log history.
Action required: 30 - Ship detained
Due 17 April 2023
Resolved 19 April 2023
Resolution: Verified the operator was familiar with the testing method. Observed them log the drill on the record book.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 April 2023 Resolved
At each initial and subsequent inspection for certification, the provisions of 176.25-30 shall apply. Main propulsion boilers, auxiliary boilers shall be given special consideration and shall be subjected to such tests and inspections as deemed necessary and specified by the officer in charge, marine inspection, to ensure that they are in safe condition. Periodic tests and examinations shall be as described in part 61 subchapter F of this chapter, except heating boilers as defined in part 53 of subchapter F of this chapter shall be tested or examined every three years. The vessel has a heating boiler with an unknown inspection history. The boiler's electronic components also appear to be an electrical hazard. The vessel shall lock and tag-out this system until a satisfactory inspection of the system by the MI is complete. 46CFR176.25-32
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2023
Resolved 15 April 2024
Resolution: Boiler inspected and tagged by a servicing company on 08APR24. MI visually inspected and observed satisfactory operation of boiler.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 17 April 2023 Resolved
A vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible. The current charts are void of updates and were printed in 2008.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2023
Resolved 19 April 2023
Resolution: Confirmed operator had new charts onboard.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 April 2023 Resolved
Each ungrounded system must be provided with a suitably sensitive ground detection system located at the respective switchboard that provides continuous indication of circuit status to ground with a provision to momentarily remove the indicating device from the reference ground. The vessel’s ground detection shows voltage and no change to the voltage detected when engaged. Vessel shall determine if the problem is with the detection system or detected voltage.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2023
Resolved 31 May 2023
Resolution: Attended vessel to verify installation of meter and full operation. All sat.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 17 April 2023 Resolved
Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information: date of the drill and training; and general description of the drill scenario and training topics. The vessel has no records of training performed in 2022 or 2023.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2023
Resolved 19 April 2023
Resolution: Observed the operator log the drill completed during the annual inspection.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 17 April 2023 Resolved
Hatch covers must have securing devices. The lazarette’s hatch cover lacks functional securing devices and is using bungee chords from the inside.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2023
Resolved 19 April 2023
Resolution: Confirmed a new latch was installed.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 17 April 2023 Resolved
Fire fighting drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information: date of the drill and training; and general description of the drill scenario and training topics. The vessel has no records of training performed in 2022 or 2023.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2023
Resolved 19 April 2023
Resolution: Observed the operator log the drill performed during the annual inspection.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 17 April 2023 Resolved
No vessel subject to inspection under 46 U.S.C. 3301 will be navigated unless it is under the direction and control of an individual who holds an appropriate license or officer endorsement on his or her MMC. The master was unable to provide a copy of his medical certificate required by 46 CFR 10.301.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2023
Resolved 19 April 2023
Resolution: Confirmed the Master possessed a valid medical card.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 17 April 2023 Resolved
A marine employer whose vessel is involved in a casualty or incident that is, or is likely to become, a serious marine incident as defined in § 4.03-2 of subchapter A of 46 CFR shall comply with the requirements of § 4.06 in subchapter A of 46 CFR. The vessel’s alcohol swabs expired in 2022 and it is not reasonable that they would be able to return within the 2 hr requirements for testing ashore.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2023
Resolved 19 April 2023
Resolution: Confirmed new strips were available.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 April 2023 Resolved
Each ring life buoy with a floating waterlight must have a lanyard of at least 910 millimeters (3 feet) in length, but not more than 1,830 millimeters (6 feet), securing the waterlight around the body of the ring life buoy. The waterlight has no lanyard attaching it to the ring buoy. Vessel is limited to daylight hours until the waterlight is installed with a lanyard.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2023
Resolved 19 April 2023
Resolution: Confirmed lanyard was installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 April 2023 Resolved
Each ring life buoy must be marked in clearly legible block capital letters with the vessel's name. The ring buoy behind the operating station lacks the vessel's name.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2023
Resolved 19 April 2023
Resolution: Confirmed the name was added.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 April 2023 Resolved
At least one ring life buoy must be fitted with a lifeline of a dark color if synthetic, or of a type certified to be resistant to deterioration from ultraviolet light. The installed lifeline is not made of dark synthetic or resistant to UV light.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2023
Resolved 19 April 2023
Resolution: Confirmed a new line was attached.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 April 2023 Resolved
Electrical equipment exposed to the weather must be watertight. The shore connection is missing a collar preventing it from being watertight.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2023
Resolved 24 May 2023
Resolution: Received pictures of fix for shore tie. All sat.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Lighting (Accommodation)
Issued 17 April 2023 Resolved
A lighting fixture must be permanently installed. The starboard light fixture aft of the operating station is loose.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2023
Resolved 19 April 2023
Resolution: Confirmed the light fixture was correctly installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 April 2023 Resolved
Electrical equipment on a vessel must be installed and maintained to provide services necessary for safety under normal and emergency conditions. The shore connection’s grounding wire is broken creating unsafe connection.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2023
Resolved 24 May 2023
Resolution: Vessel operators installed new ground wire. Picture attached. All sat.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Lighting (Accommodation)
Issued 17 April 2023 Resolved
Each lighting fixture globe, lens, or diffuser must have a guard or be made of high strength material, except in an accommodation space, radio room, galley, or similar space where it is not subject to damage. The main deck has a light with a missing guard.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2023
Resolved 19 April 2023
Resolution: Confirmed a guard was installed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 17 April 2023 Resolved
Electrical equipment must be installed and maintained to minimize accidental personnel contact with energized parts. The most aft electrical outlet on the main deck is missing an outlet cover.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2023
Resolved 19 April 2023
Resolution: Confirmed the cover was installed.
99 - Other › N/A - No Subsystem › Other (MARPOL operational)
Issued 15 April 2022 Resolved
A National Pollutant Discharge Elimination System (NPDES) permit issued under 122.28 authorizing a category of discharges under the Clean Water Act within the geographical area. No Vessel General Permit kept onboard. Apply through EPA for VGP and keep onboard at all times. 40CFR122.28, CG-543 Policy Letter 11.01
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 April 2022
Resolved 9 May 2022
Resolution: Complied with VGP requirement.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 15 April 2022 Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 50 millimeters (2 inches) high: “EMERGENCY EXIT, KEEP CLEAR”, unless such markings are deemed unnecessary by the cognizant [name withheld] engine room escape exit according to regulation.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2022
Resolved 9 May 2022
Resolution: Labeled emergency escape.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 15 April 2022 Resolved
A weather-tight door must be provided for each opening located in a deck house or companionway. All weather-tight doors are missing gaskets. Make all doors weather-tight in pilot house.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2022
Resolved 9 May 2022
Resolution: Doors weather-tight in pilot house.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 15 April 2022 Resolved
Electrical equipment used in a location normally exposed to splashing, water wash-down, or other wet conditions within a galley must be drip-proof. Electrical outlet cover missing in galley. Replace and secure new cover.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2022
Resolved 9 May 2022
Resolution: Secured new cover.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 15 April 2022 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Electrical outlet cover missing in pilot house. Replace and secure new cover.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2022
Resolved 9 May 2022
Resolution: Secured new cover.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 15 April 2022 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible. Electric charts are not up-to-date. Update charts.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2022
Resolved 9 May 2022
Resolution: New charts on vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 15 April 2022 Resolved
Each ring life buoy must be marked with Type II retroreflective material approved in 46CFR164.018 or other standard specified by the Commandant. The arrangement of the retroreflective material applied after March 11, 1996, must be as specified by IMO Resolution A.658(16). Ring Buoy reflective tape missing on (3) upper deck life ring buoys. Renew retroreflective tape and place back into service as intended. 46CFR185.604(i), IMO Res. A.658(16)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2022
Resolved 9 May 2022
Resolution: Installed tape on all ring buoys
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 15 April 2022 Resolved
Electrical equipment in spaces containing machinery powered by, or fuel tanks for, gasoline or other fuel having a flashpoint of 43.3C (110F) or lower must be explosion-proof or ignition-protected, or be part of an intrinsically safe system. Glass bulb light cover missing around light in aft engine room. Recover to make safe of hazards.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2022
Resolved 9 May 2022
Resolution: Installed light cover
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 15 April 2022 Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space. Flashlight in engine room not operational. Renew batteries and satisfactory test.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2022
Resolved 9 May 2022
Resolution: Provided flashlights as required.
09 - Working and Living Conditions › 092 - Working Conditions › Anchoring devices
Issued 15 April 2022 Resolved
A vessel must be fitted with ground tackle necessary for the vessel to be safely anchored. The ground tackle provided must be satisfactory for the size of the vessel, the waters on which the vessel operates, subject to the approval of the cognizant [name withheld] swivel and shackle were heavily corroded and was unable to attach anchor to deploy rapidly. Renew swivel and shackle.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2022
Resolved 9 May 2022
Resolution: New line, chain and shackle.
08 - Alarms › N/A - No Subsystem › Emergency signal
Issued 15 April 2022 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in a space with a non-water-tight closure, such as a space with a non-watertight hatch on the main deck. No alarm sounded in the pilot house for the forepeak bilge alarm. Correct before sail.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 15 April 2022
Resolved 15 April 2022
Resolution: Corrected on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 April 2021 Resolved
At least one ring life buoy must be fitted with a lifeline. If more than one ring life buoy is carried, at least one must not have a lifeline attached. Each lifeline on a ring life buoy must: Be buoyant; Be of at least 18.3 meters (60 feet) in length; Be non-kinking; Have a diameter of at least 7.9 millimeters (5/16 inch); Have a breaking strength of at least 5 kilonewtons (1,124); and Be of a dark color if synthetic, or of a type certified to be resistant to deterioration from ultraviolet light. Vessel's lifebuoys were not equipped with a lifeline.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2021
Resolved 25 May 2021
Resolution: A lifeline was added to one of the ring life buoys.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 April 2021 Resolved
Each life jacket, immersion suit, and ring life buoy must be marked in clearly legible block capital letters with the vessel’s name. One of the ring life buoys did not have the vessel’s name marked.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2021
Resolved 25 May 2021
Resolution: The ring life buoy was marked with the vessel's name.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 April 2021 Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. The vessel had a donning placard but it was not posted.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2021
Resolved 25 May 2021
Resolution: The life jacket donning placard was posted.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 28 April 2021 Resolved
Portable fire extinguishers must be located so that they are clearly visible and readily accessible from the space being protected. The installation and location must be to the satisfaction of the Officer in Charge, Marine inspection. One of the fire extinguishers was attached by bungee cords and was not installed in the approved bracket made by the manufacturers.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2021
Resolved 4 June 2021
Resolution: Correct bracket was installed as per manufacturer's instructions
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 April 2021 Resolved
Connections must be made to battery terminals with permanent type connectors. Vessel’s battery are installed with temporary wing nuts. 46 CFR 183.05-20(c)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2021
Resolved 4 June 2021
Resolution: Correct nuts were installed on battery terminals.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 28 April 2021 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date tide tables and current tables. Vessel's does not have an updated tide/current tables.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2021
Resolved 25 May 2021
Resolution: Vessel received updated publication.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 12 May 2020 Resolved
EPIRB shall have valid NOAA registratio. NOAA registration is expired. Provide current registration.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 May 2020
Resolution: Provided current EPIRB registratioin.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 12 May 2020 Resolved
Portable fire extinguishers must be serviced. Extinguishers not serviced due to no available technicians, due to COVED-19. Service fire extinguishers prior to carrying passengers.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 19 May 2020
Resolution: Serviced all fire extinguishers.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 25 April 2019 Resolved
All vessels must have navigation lights that are in compliance with Inland Navigation Rules. Vessel's stern light is inoperable. Vessel restricted to daytime operations.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2019
Resolved 25 June 2019
Resolution: Operator replaced stern light bulb, light is now operational.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 25 April 2019 Resolved
At each inspection for certification, an MI may require that a MOB drill be held. Vessel requested MOB drill to be held after crew change in June. MOB drill must be conducted in the presence of an [name withheld] 20Jun19 (90-day expiry date from renewal COI--20Mar2017).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2019
Resolved 25 June 2019
Resolution: Vessel conducted satisfactory MOB drill in the presence of an MI.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 25 April 2019 Resolved
Vessels shall be equipped with a suitable number of portable battery lights. Portable battery light at operating station is inoperable. 46CFR184.30-1(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2019
Resolved 25 June 2019
Resolution: Batteries were replaced in the portable light near the operating station, light is now operational.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 April 2019 Resolved
Portable fire extinguishers shall be installed to the satisfaction of the [name withheld] fire extinguisher located aft in main deck cabin unsecured.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2019
Resolved 25 June 2019
Resolution: Portable fire extinguisher aft in main deck cabin secured.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 April 2019 Resolved
For items not covered by standards, inspection shall be IAW standards acceptable to the OCMI, as good marine practice. Port and starboard fire hydrant stations are unmarked. 46CFR176-25-1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2019
Resolved 25 June 2019
Resolution: Port and Starboard fire hydrant stations properly marked.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 10 September 2018 Resolved
Vsl is broadcasting no static draft information
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 16 October 2018
Resolution: During a query in VIVS, draft information had been updated. AIS is broadcasting the proper information.
Communications › Alarms/Indicators › High Water Alarm
Issued 30 April 2018 Resolved
Repair fore peak high water alarm by 15MAY18, while under way have crew member conduct 30 minute rounds of space; 46CFR182.520.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2018
Resolved 16 May 2018
Lifesaving › Lifefloat › Markings
Issued 30 April 2018 Resolved
Replace name and worn retro on life floats by 15MAY18; 46CFR185.604.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2018
Resolved 16 May 2018
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 30 April 2018 Resolved
Repair (2) life float water lights by 15MAY18; 46CFR175.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2018
Resolved 16 May 2018
Communications › Radio Communications › VHF Radiotelephone
Issued 30 April 2018 Resolved
Provide proof of VSL safety radio certificate and Bridge to Bridge certificate by 15MAY18; 47CFR13.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2018
Resolved 16 May 2018
Communications › Alarms/Indicators › High Water Alarm
Issued 30 April 2018 Resolved
Install light for engine room high water alarm in pilot house by 15MAY18; 46CFR182.520.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2018
Resolved 16 May 2018
Electrical › Electrical Distribution System (service) › Wiring
Issued 30 April 2018 Resolved
Install metal wire hangers on all wire runs in engine room by 30APR19; 46CFR183.340.
Due 30 April 2019
Resolved 25 June 2019
Resolution: Metal wire ties installed
Engineering › Steam Boiler (auxiliary/waste heat) › Piping
Issued 30 April 2018 Resolved
TJT06- Not to operate heating boiler on boat till the following tests/inspections completed to the satisfaction of attending Marine Inspector NLT 30SEP18; a) fire side/water side inspection, b) boiler hydro, c) boiler relief and gauge tested, d) boiler mount valves, e) fusible plug.
Action required: 705 - Other - as specified
Due 30 September 2018
Resolved 25 April 2019
Resolution: In lieu of meeting required inspections and periodic testing of vessel's heating boiler, vessel rep stated he does not/will not operate while carrying passengers.
Documentation › Certificates/Documents › FCC SSL
Issued 20 March 2017 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 April 2017
Resolved 17 April 2017
Resolution: Verified new certificate.
Documentation › Logs/Records › Logbook (official)
Issued 20 March 2017 Resolved
Log man overboard and fire fighting drills. Provide log.
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 April 2017
Resolved 17 April 2017
Resolution: Verified log.
Navigation › Piloting/Steering › US Coast Pilot
Issued 20 March 2017 Resolved
Provide the required publications, tide tables, currents, and coast pilot.
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 April 2017
Resolved 17 April 2017
Resolution: Verified proper publications.
Fire Fighting › Fire Pumps › Pressure
Issued 20 March 2017 Resolved
Provide gauge for fire pump.
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 April 2017
Resolved 17 April 2017
Resolution: Verified gauge installation.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 20 March 2017 Resolved
Provide label for fwd life jacket storage on main deck.
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 April 2017
Resolved 17 April 2017
Resolution: Storage compartment labeled.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 20 March 2017 Resolved
Vessel restricted to daytime operation until stern light is operational.
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 April 2017
Resolved 17 April 2017
Resolution: Stern light operational.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 20 March 2017 Resolved
Vessel total persons count restricted to 152, (149 Pax) until 01 additional life jacket is on board.
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 April 2017
Resolved 17 April 2017
Resolution: New pfd verified on board.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 20 March 2017 Resolved
Install cover on electrical junction box in engine room on the port side.
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 April 2017
Resolved 17 April 2017
Resolution: cover installed.
Lifesaving › Lifebuoys › Serviceable
Issued 20 March 2017 Resolved
Replace 02 ring buoys on upper deck.
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 April 2017
Resolved 17 April 2017
Resolution: Ring buoys replaced.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 20 March 2017 Resolved
Replace retro reflective tape on numerous child life jackets.
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 April 2017
Resolved 17 April 2017
Resolution: retro relective tape replaced on all child life jackets.
Navigation › Piloting/Steering › US Coast Pilot
Issued 25 April 2016 Resolved
Provide new costal pilot AND light list by 10MAY16, 46CFR184.420.
Action required: 705 - Other - as specified
Due 10 May 2016
Resolved 23 May 2016
Resolution: New costal pilot and light list.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 25 April 2016 Resolved
Provide new battery for life float water light by 10MAY16, 46CFR180.200.
Action required: 705 - Other - as specified
Due 10 May 2016
Resolved 23 May 2016
Resolution: new battery.
Operations/Management › Vessel Activity › Underway
Issued 11 February 2016 Resolved
not to carry passengers until U/W trails complete and MSC plan approval.
Action required: 705 - Other - as specified
Resolved 5 April 2016
Resolution: Plans approved, reviewed and U/W sea trials complete.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.