MAURY USCG vessel records
← All vessels

GREAT POINT

Built
1988
Last inspected
28 April 2023
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 28 April 2023
Operational controls None recorded without a removal date
Years with a record 8 calendar years (2016–2023)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDJ6637
309239
Flag
UNITED STATES
Maury page id
psix-309239

Documentation record

Registered dimensions (L × B × D)169.5 ft × 35.1 ft × 7.5 ft
Registered tonnagegross 71 / net 48
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWASHBURN & DOUGHTY ASSOCIATES INC · EAST BOOTHBAY, ME, UNITED STATES · built 1988
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW YORK, NY
Endorsements, as the file codes themcw_un
DocumentationValid · issued 9 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it71 - Regulatory (Subpart C or D), Gross Ton
48 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 15 inspections, each with its date, unit and type; 12 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 15

28 April 2023 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7677458
6 April 2023 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7664000
18 November 2022 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7596659
14 October 2021 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7335047
22 January 2021 Administrative Inspection · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7128748
9 December 2020 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7109091
10 August 2020 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7028803
7 May 2019 COI Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6678526
25 February 2019 Deficiency Check · Examination of Repairs · Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6630783
29 June 2018 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6459303
5 October 2017 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6281713
19 July 2017 In-Service Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6206797
28 June 2017 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6189446
1 June 2017 Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6154554
7 July 2016 Examination of Repairs · Deficiency Check · Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5923913

Deficiency record · 12

02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 18 October 2021 Resolved
Port side escape door was found welded from outside.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 November 2021
Resolved 4 March 2022
Resolution: Check special note to ensure item is properly rectified.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 18 October 2021 Resolved
Windows found with excessive rust and wastage.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 November 2021
Resolved 4 March 2022
Resolution: Check special note to ensure item is properly rectified.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 25 February 2019 Resolved
Vessel shall have a valid COI to carry passengers. The vessel's COI expired 12Apr2019. 46CFR115.100(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2019
Resolution: vessel completed COI inspection
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 25 February 2019 Resolved
CROP AND RENEW FIRE MAIN @ ELBOWS, FORWARD OF THE TONNAGE BULKHEAD IN THE POTABLE WATER VOID.
Action required: 705 - Other - as specified
Resolved 6 May 2019
Resolution: PIPES/ELBOWS WERE REPLACED, VERIFIED IN PERSON BY [name withheld] PHOTO BY [name withheld]
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 29 June 2018 Resolved
A qualified service facility deemed installed time delay on the Halon fire fighting system as installed would not meet service inspection approval. Time delay removed and system put back into operation by technician. Plans must be provided to the OCMI for approval of time delay installation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 July 2018
Resolved 19 July 2018
Resolution: Vessel provided required plans.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 19 July 2017 Resolved
Vessel is required to conduct MOB drills to the satisfaction of attending marine inspector
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 21 July 2017
Resolution: MI observed satisfactory man overboard drill.
Engineering › Bilge Water Management System › Not Operational
Issued 19 July 2017 Resolved
vessel must prove proper operation of bilge system
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 July 2017
Resolution: MI observed satisfactory operation of the bilge system.
Lifesaving › Buoyant Apparatus › Serviceable
Issued 19 July 2017 Resolved
Vessel route has been restricted to LBS not more than one mile until life savings req are met.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 June 2019
Resolution: Operator stated deficiency was cleared back in 2017. Operator requested in reduction in route to operate within 1 mile from shore under Lakes, Bays, and Sounds; no longer requiring survival craft onboard vessel.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 7 July 2016 Resolved
Conduct underway man overboard and fire drill prior to carrying passengers.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 August 2016
Resolved 21 July 2017
Resolution: Satisfactory MOB drill conducted during inspection.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 7 July 2016 Resolved
16 water light batteries were expired. Replace 16 water light batteries.
Condition: Invalid
Action required: 705 - Other - as specified
Due 21 July 2016
Resolved 18 July 2016
Resolution: Replaced batteries.
Engineering › Pressure Vessel › Maximum Allowable Working Pressure
Issued 7 July 2016 Resolved
Air recievers are over due for internal inspection as of April 2016. Make air recievers available for inspection prior to sailing.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 8 August 2016
Resolved 26 July 2016
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 7 July 2016 Resolved
First aid kit is expired. Replace first aid kit.
Condition: Invalid
Action required: 705 - Other - as specified
Due 21 July 2016
Resolved 18 July 2016
Resolution: Replaced first aid kit.

Ownership record