GREAT POINT

GREAT POINT is a 1988 passenger vessel (inspected). The Coast Guard has recorded 90 inspections since 1988, most recently in April 2023, along with 110 deficiencies and 2 casualty investigations between 2006 and 2007.

Records from 1988 to 2023. Most recent: inspection, 28 April 2023.

Built
1988
Last inspected
28 April 2023
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDJ6637
309239
Flag
UNITED STATES
367799740
Maury page id
psix-309239

Inspections, by type

…with no type recorded11
Years with a record 32 calendar years (1988–2023)
The 90 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)169.5 ft × 35.1 ft × 7.5 ft
Registered tonnagegross 71 / net 48
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWASHBURN & DOUGHTY ASSOCIATES INC · EAST BOOTHBAY, ME, UNITED STATES · built 1988
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 9 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it71 - Regulatory (Subpart C or D), Gross Ton
48 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDJ6637MMSI 367799740 · active · compulsorily equipped · granted 14 July 2017, expires 14 July 2027
WUW5930MMSI 367459870 · expired · compulsorily equipped · granted 7 July 2010, cancelled 31 October 2020
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

NORTHERN APPROACH Commercial Fishing Vessel · MISLE 433662 · 21 October 2007 · activity 3085444

Inspection history · 90

28 April 2023 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7677458
6 April 2023 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7664000
18 November 2022 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7596659
14 October 2021 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7335047
22 January 2021 Administrative Inspection · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7128748
9 December 2020 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7109091
10 August 2020 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7028803
7 May 2019 COI Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6678526
25 February 2019 Deficiency Check · Examination of Repairs · Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6630783
29 June 2018 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6459303
5 October 2017 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6281713
19 July 2017 In-Service Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6206797
28 June 2017 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6189446
1 June 2017 Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6154554
7 July 2016 Examination of Repairs · Deficiency Check · Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5923913
8 August 2015 Damage Survey · Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 5212002
15 May 2012 Deficiency Check · Plan Review (Other than "T") · Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 4311785
23 April 2009 Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3459100
17 March 2009 COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 3434848
7 May 2008 Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 3184338
25 October 2007 Deficiency Check · Internal Structural Exam · Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3085494
21 October 2007 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3085444
11 July 2007 Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 2974875
29 January 2007 Hull Examination · Construction Oversight · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2863510
25 August 2006 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2762045
25 August 2006 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2762061
27 June 2006 Type not recorded
No type recorded · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 2695377
20 April 2006 Annual Inspection · Deficiency Check · MTSA Verification
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 2631444
29 July 2005 MTSA Verification
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2443748
8 July 2005 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2423953
14 April 2005 Re-Inspection
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2331227
6 April 2005 In-Service Inspection
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2326255
10 December 2004 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2256809
12 August 2004 MTSA Verification
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2163529
12 April 2004 COI Inspection
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2042107
23 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1978101
28 May 2003 Deficiency Check
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 1803010
27 March 2003 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1763646
6 November 2002 Re-Inspection
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 1701138
23 July 2002 Deficiency Check
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 1650666
19 March 2002 In-Service Inspection
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 1494924
5 November 2001 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1408868
12 January 2001 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1466189
31 October 2000 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1445692
8 July 2000 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 177812
3 November 1999 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1458688
24 March 1999 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1381519
5 November 1998 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1472740
14 April 1998 Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1123609
4 November 1997 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 785867
28 July 1997 Damage Survey
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 781866
27 July 1997 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 40352
22 April 1997 Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1096274
11 April 1997 Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1452269
29 January 1997 Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1101777
19 November 1996 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 870156
17 September 1996 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 149785
12 June 1996 Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1086735
10 April 1996 Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1081924
8 November 1995 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1191903
20 June 1995 Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1190388
29 March 1995 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1147607
27 February 1995 Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1460766
9 February 1995 Examination of Repairs
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 842851
10 June 1994 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1326193
26 April 1994 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1353554
22 June 1993 Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1153413
25 May 1993 Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1140919
5 May 1993 Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 829749
22 April 1993 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1385061
1 April 1993 Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1145950
16 September 1992 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 181303
1 July 1992 Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1269416
1 May 1992 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 962026
30 March 1992 Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1254849
16 October 1991 Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 937151
3 June 1991 Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 912074
6 May 1991 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1225959
17 May 1990 Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1219568
9 May 1990 Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 916502
3 April 1990 Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1216111
14 March 1990 Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1226800
14 February 1990 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 916592
8 March 1989 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 889007
28 February 1989 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1201848
23 January 1989 Hull Examination · Plan Review "T" Boat
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 891854
12 September 1988 Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1041611
2 September 1988 Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1353063
15 August 1988 Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1347756
11 August 1988 Plan Review "T" Boat · Hull Examination · Initial Certification
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1035965

Deficiency record · 110

02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 18 October 2021 Resolved
Port side escape door was found welded from outside.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 November 2021
Resolved 4 March 2022
Resolution: Check special note to ensure item is properly rectified.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 18 October 2021 Resolved
Windows found with excessive rust and wastage.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 November 2021
Resolved 4 March 2022
Resolution: Check special note to ensure item is properly rectified.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 25 February 2019 Resolved
Vessel shall have a valid COI to carry passengers. The vessel's COI expired 12Apr2019. 46CFR115.100(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2019
Resolution: vessel completed COI inspection
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 25 February 2019 Resolved
CROP AND RENEW FIRE MAIN @ ELBOWS, FORWARD OF THE TONNAGE BULKHEAD IN THE POTABLE WATER VOID.
Action required: 705 - Other - as specified
Resolved 6 May 2019
Resolution: PIPES/ELBOWS WERE REPLACED, VERIFIED IN PERSON BY [name withheld] PHOTO BY [name withheld]
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 29 June 2018 Resolved
A qualified service facility deemed installed time delay on the Halon fire fighting system as installed would not meet service inspection approval. Time delay removed and system put back into operation by technician. Plans must be provided to the OCMI for approval of time delay installation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 July 2018
Resolved 19 July 2018
Resolution: Vessel provided required plans.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 19 July 2017 Resolved
Vessel is required to conduct MOB drills to the satisfaction of attending marine inspector
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 21 July 2017
Resolution: MI observed satisfactory man overboard drill.
Engineering › Bilge Water Management System › Not Operational
Issued 19 July 2017 Resolved
vessel must prove proper operation of bilge system
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 July 2017
Resolution: MI observed satisfactory operation of the bilge system.
Lifesaving › Buoyant Apparatus › Serviceable
Issued 19 July 2017 Resolved
Vessel route has been restricted to LBS not more than one mile until life savings req are met.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 June 2019
Resolution: Operator stated deficiency was cleared back in 2017. Operator requested in reduction in route to operate within 1 mile from shore under Lakes, Bays, and Sounds; no longer requiring survival craft onboard vessel.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 7 July 2016 Resolved
Conduct underway man overboard and fire drill prior to carrying passengers.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 August 2016
Resolved 21 July 2017
Resolution: Satisfactory MOB drill conducted during inspection.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 7 July 2016 Resolved
16 water light batteries were expired. Replace 16 water light batteries.
Condition: Invalid
Action required: 705 - Other - as specified
Due 21 July 2016
Resolved 18 July 2016
Resolution: Replaced batteries.
Engineering › Pressure Vessel › Maximum Allowable Working Pressure
Issued 7 July 2016 Resolved
Air recievers are over due for internal inspection as of April 2016. Make air recievers available for inspection prior to sailing.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 8 August 2016
Resolved 26 July 2016
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 7 July 2016 Resolved
First aid kit is expired. Replace first aid kit.
Condition: Invalid
Action required: 705 - Other - as specified
Due 21 July 2016
Resolved 18 July 2016
Resolution: Replaced first aid kit.
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (air motor)
Issued 8 August 2015 Resolved
Prove proper operation of the starboard main engine prior to operating with passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 August 2015
Resolution: Proved proper operation of the starboard main engine.
Operations/Management › Drills/Instruction › Not Conducted
Issued 15 May 2012 Resolved
Conduct man-overboard, fire abandon ship and security drills with a Coast Guard Marine Inspector.
Action required: 705 - Other - as specified
Due 15 June 2012
Resolved 15 June 2012
Engineering › Steering Gear System › Piping
Issued 15 May 2012 Resolved
Repair leaks on fittings for lube oil tank in steering gear space.
Action required: 705 - Other - as specified
Due 15 June 2012
Resolved 15 June 2012
Engineering › Lubricating Oil Storage/Transfer System › Piping
Issued 15 May 2012 Resolved
Repair leak on fitting for waste oil pipe in void aft of engineroom.
Action required: 705 - Other - as specified
Due 15 June 2012
Resolved 24 May 2012
Resolution: Old piping cut out and new fitting installed. Deficiency cleared.
Engineering › Sea-water System (primary cooling) › Piping
Issued 15 May 2012 Resolved
Repair 1.25 inch coupling for salt water piping on port side of dry stores void.
Action required: 705 - Other - as specified
Due 15 June 2012
Resolved 24 May 2012
Resolution: Old piping cut out and welded in. Deficiency cleared.
Engineering › Fuel Oil Service System › Filter
Issued 15 May 2012 Resolved
Diagnose and repair oil leak on #2 generator.
Action required: 705 - Other - as specified
Due 22 May 2012
Resolved 24 May 2012
Resolution: Catepillar representatives fixed wasted gaskets. Deficiency cleared.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 15 May 2012 Resolved
Prove proper operation of emergency light in aft portion of luggage room.
Action required: 705 - Other - as specified
Due 15 June 2012
Resolved 24 May 2012
Resolution: Emergency light replaced. Deficiency cleared.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 15 May 2012 Resolved
Label emergency lights in heads and entrance to dry stores.
Action required: 705 - Other - as specified
Due 15 June 2012
Resolved 24 May 2012
Resolution: Emergency lights labeled. Deficiency cleared.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 15 May 2012 Resolved
Prove proper operation of starboard running light.
Action required: 705 - Other - as specified
Due 22 May 2012
Resolved 24 May 2012
Resolution: Starboard running light bulb replaced. Deficiency cleared.
Communications › Public Address System › Loudspeaker
Issued 15 May 2012 Resolved
Prove proper operation of public address speaker in port aft of first class lounge.
Action required: 705 - Other - as specified
Due 15 June 2012
Resolved 24 May 2012
Resolution: PA speaker was operational. Deficiency cleared.
Accommodation/Occupational Safety › Cooking Systems › Cooking Fuel
Issued 15 May 2012 Resolved
Sanitize toaster and bagel slicer.
Action required: 705 - Other - as specified
Due 15 June 2012
Resolved 24 May 2012
Resolution: Both devices cleaned out. Deficiency cleared.
Engineering › Fuel Oil Service System › Piping
Issued 6 April 2009 Resolved
Bow thruster emergency remote fuel suction valve operating gear found missing the appropriate labeling. Relabel this valve prior to commencing commercial operations for attending USCG inspector.
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 April 2009
Resolved 14 May 2009
Engineering › Diesel Engine (propulsion-reduction gear) › Governor
Issued 6 April 2009 Resolved
Main engine over-speed trips unable to be tested. Demonstrate proper operation of this protective equipment prior to commencing commercial operations for attending USCG inspector.
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 April 2009
Resolved 8 April 2009
Engineering › Generator (propulsion/auxiliary-electric) › Overcurrent Devices Circuitry
Issued 6 April 2009 Resolved
S/S generator over-speed trips unable to be tested. Demonstrate proper operation of this protective equipment prior to commencing commercial operations for attending USCG inspector.
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 April 2009
Resolved 8 April 2009
Engineering › Lubricating Oil Service System › Filter
Issued 6 April 2009 Resolved
Unacceptable oil filter leak found on #1 SS generator oil filter canister. Engine placed out of commission and vessel out of commercial operations till this leak is repaired and demonstrated acceptable to an attending USCG inspector.
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 April 2009
Resolved 8 April 2009
Engineering › Generator (propulsion/auxiliary-electric) › Indicator Circuitry
Issued 6 April 2009 Resolved
#2 SS generator bridge panel mounted oil pressure gauge found inoperable. Repair or replace this gauge and demonstrate proper operation to attending USCG inspector prior to commercial operations.
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 April 2009
Resolved 8 April 2009
Fire Fighting › Fire Main › Pressure
Issued 6 April 2009 Resolved
Fire main pressure gauge in engine room found inoperable. Repair or renew this gauge and demonstrate proper operation to an attending USCG inspector prior to commencing commercial operations.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 6 April 2009
Resolved 8 April 2009
Engineering › Bilge Water Management System › Strainer
Issued 6 April 2009 Resolved
Most bilge suction line foot valves that are supposed to be mounted in all ships compartments found to be missing or inoperable. Repair or renew these foot valves prior to commencing commercial operations to satisfaction of attending USCG inspector.
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 April 2009
Resolved 8 April 2009
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 6 April 2009 Resolved
Main deck passenger cabin bench seats missing and exposed mounting bolt hardware left on deck as tripping hazards. Install these missing seats or remove the tripping hazards to satisfaction of attending USCG inspector prior to commencing commercial operations.
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 April 2009
Resolved 8 April 2009
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 6 April 2009 Resolved
Remove all non magnetic holdbacks on doors in A class bulkheads; ensure doors fully close.
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 April 2009
Resolved 8 April 2009
Lifesaving › Buoyant Apparatus › Serviceable
Issued 6 April 2009 Resolved
Service vessel's buoyant apparatus'. Many are gouged deep into the material.
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 April 2009
Resolved 8 April 2009
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 6 April 2009 Resolved
Service life jackets on vessel; most are in need of retro reflective tape replacement.
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 April 2009
Resolved 8 April 2009
Engineering › Bilge Water Management System › Interface Detector
Issued 6 April 2009 Resolved
Prove proper operation of the high level bilge alarm in the water tank void.
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 April 2009
Resolved 8 April 2009
Personnel › Manning/Qualifications › Qualified Individual (VRP)
Issued 6 April 2009 Resolved
Ensure Employee Assistance Program is fully implemented on the vessel.
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 April 2009
Resolved 8 April 2009
Electrical › Lighting (service) › Lighting Fixture
Issued 6 April 2009 Resolved
Ensure all lighting is installed throughout vessel. Several areas were noted as not having lights in the light fixtures.
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 April 2009
Resolved 8 April 2009
Fire Fighting › Ventilation Systems › Operating Controls
Issued 6 April 2009 Resolved
Prove proper operation of ventilation shutdowns from remote locations (bridge and pantry).
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 April 2009
Resolved 8 April 2009
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 7 May 2008 Resolved
Navigation Lights - Worn
Due 16 May 2008
Resolved 16 May 2008
Lifesaving › Buoyant Apparatus › Lifeline
Issued 7 May 2008 Resolved
Replace light line to buoyant apparatus located portside aft stack on pilot house deck.
Due 16 May 2008
Resolved 13 May 2008
Resolution: Light line replaced.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 7 May 2008 Resolved
Replace lifefloat line to pilot house port lifefloat.
Due 16 May 2008
Resolved 13 May 2008
Resolution: Lifeboat line replaced.
Communications › Radio Communications › EPIRB
Issued 7 May 2008 Resolved
Determine EPIRB hydro expiration date.
Due 16 May 2008
Resolved 13 May 2008
Resolution: HRU date labelled.
Engineering › Fuel Oil Service System › Valve, Control
Issued 7 May 2008 Resolved
Move bow thruster fuel shut off valve outside bow thruster compartment.
Condition: Improper Installation
Due 16 May 2008
Resolved 16 May 2008
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 7 May 2008 Resolved
Replace trash barrels throughout vsl w/ non-combustible barrels/recepticles
Condition: Unknown
Due 16 May 2008
Resolved 13 May 2008
Resolution: Trash barrels replaced w/ non-combustible receptacles.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 7 May 2008 Resolved
Make repairs to fire screen doors throughout vsl.
Condition: Improper/Lack of Maintenance
Due 16 May 2008
Resolved 13 May 2008
Resolution: FSDs operational
Construction/Loadline › Structures › Door
Issued 7 May 2008 Resolved
Repair weather tight doors fwd 01 deck.
Condition: Improper/Lack of Maintenance
Due 16 May 2008
Resolved 13 May 2008
Resolution: Weathertight doors repaired.
Fire Fighting › Nozzles › Condition
Issued 7 May 2008 Resolved
Ensure fire main station nozzles are operational.
Due 16 May 2008
Resolved 13 May 2008
Resolution: Nozzles operational
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 7 May 2008 Resolved
Replace or clean fuel tank fuel vent screens.
Condition: Improper/Lack of Maintenance
Due 16 May 2008
Resolved 13 May 2008
Resolution: Vents cleaned
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 7 May 2008 Resolved
Replace missing bolts to deck seating throughout vessel.
Due 16 May 2008
Resolved 13 May 2008
Resolution: Deck seating secured
Electrical › Electric Generation Source (emergency) › Generator
Issued 7 May 2008 Resolved
Repair #1 generator emergency shutdown.
Due 16 May 2008
Resolved 13 May 2008
Resolution: ESD operational
Electrical › Lighting (emergency) › Lighting Fixture
Issued 7 May 2008 Resolved
Replace anchor lights.
Due 16 May 2008
Resolved 13 May 2008
Resolution: Lighting repaired
Construction/Loadline › Hull › Hull Plating
Issued 21 October 2007 Resolved
Conduct a damage survey of the bow area resulting from an allision.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 October 2007
Resolution: Completed on 21 October
Engineering › Compressed Air System (control) › Piping
Issued 21 October 2007 Resolved
Conduct a full power trail, switching from pilot house control to both bridge wing operating control stations.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 October 2007
Resolution: Satisfactorily completed this date.
Engineering › Compressed Air System (control) › Piping
Issued 11 June 2007 Resolved
Properly support copper pneumatic lines for port/stbd MDE's (no wireties).
Action required: 705 - Other - as specified
Due 11 July 2007
Resolved 11 July 2007
Resolution: Satisfactorily resolved this date.
Engineering › Diesel Engine (propulsion-direct drive) › Valve
Issued 11 June 2007 Resolved
Provide documentation of grade/spec for all new piping, valves, hoses, fittings, and flex connectors used on MDE's.
Action required: 705 - Other - as specified
Due 22 June 2007
Resolved 20 June 2007
Resolution: Rcvd package from Dick Moore with all above info enclosed.
Documentation › Logs/Records › Record Book of Engine Parameters
Issued 11 June 2007 Resolved
Provide copy of CAT tech test report for MDE's.
Action required: 705 - Other - as specified
Due 22 June 2007
Resolved 20 June 2007
Resolution: rcvd package from Dick Moore with CAT tech report enclosed.
Construction/Loadline › Penetrations › Valve Flange
Issued 11 June 2007 Resolved
Remove or relocate portable water 3/4" piping obstructing Port MDE keel cooler outlet valve.
Action required: 705 - Other - as specified
Due 11 July 2007
Resolved 11 July 2007
Resolution: Satisfactorily resolved this date.
Construction/Loadline › Penetrations › Valve Flange
Issued 11 June 2007 Resolved
Relocate/clamp battery charger lead armored cable for #1 genset batteries to prevent chafing from stbd MDE keel cooler outlet butterfly valve handle.
Action required: 705 - Other - as specified
Due 11 July 2007
Resolved 11 July 2007
Resolution: Satisfactorily resolved this date.
Documentation › Certificates/Documents › Stability Letter
Issued 7 June 2007 Resolved
Obtain an approved stability letter from USCG MSC.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 July 2007
Resolved 10 July 2007
Resolution: MSC letter dated 10July2007.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 7 June 2007 Resolved
Prove proper operation and installation of engine control mechanisms.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 July 2007
Resolved 11 June 2007
Resolution: Control mechanisms proved to be properly installed and operated sat during u/w testing.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 7 June 2007 Resolved
Conduct operational test of the port and starboard propulsion engines.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 July 2007
Resolved 11 June 2007
Resolution: MDE''s tested while u/w. Ahead, astern, crash stop, and idle. All sat.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 8 January 2007 Resolved
Prior to the carriage of passengers for hire complete satisfactory credit dry-dock exam in the presence of a Coast Guard Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 June 2007
Resolution: Credit dry-dock completed.
Communications › Alarms/Indicators › Steering Failure Alarm System
Issued 20 April 2006 Resolved
Repair inoperative lights (demonstrate proper operation) of steering alarm box on bridge.
Due 20 May 2006
Resolved 13 June 2006
Communications › Alarms/Indicators › Bilge Alarm
Issued 20 April 2006 Resolved
Repair audible/visual alarm at bridge for lazarette high level water alarm.
Due 20 May 2006
Resolved 13 June 2006
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 20 April 2006 Resolved
Repair breaker box door in fan room.
Due 20 May 2006
Resolved 20 June 2006
Electrical › Electrical Distribution System (service) › Junction Box
Issued 20 April 2006 Resolved
Properly secure face plate on circuit relay box in fan room.
Due 20 May 2006
Resolved 13 June 2006
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 20 April 2006 Resolved
Segregate and label child PFD stowage (laundry bags ok.)
Due 20 May 2006
Resolved 13 June 2006
Engineering › Generator (propulsion/auxiliary-electric) › Battery
Issued 14 April 2005 Resolved
CHARGE E-GEN BATTERIES AND CONDUCT OPERATIONAL TESTING OF THE SYSTEM.
Action required: 705 - Other - as specified
Due 25 May 2005
Resolved 25 May 2005
Resolution: CONTACTED BY VESSEL REP STATING ALL BATTERIES REPLACED AND TESTING SAT.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 14 April 2005 Resolved
CONDUCT UNDERWAY DRILLS AND OPERATIONS.
Action required: 705 - Other - as specified
Due 19 August 2005
Resolved 29 July 2005
Resolution: DRILLS COMPLETED SAT.
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 10 December 2004 Resolved
Air reciever inspection overdue. Was required to be completed by 03 N0V 2004.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 December 2004
Resolved 6 April 2005
Resolution: All receivers hydrostatically tested to 1 1/4 MAWP. Tests sat.
Lifesaving › Lifefloat › Capacity
Issued 12 April 2004 Resolved
Prior to carriage of passengers install full compliment of life floats to bring capacity to required 50%.
Due 15 April 2004
Resolved 15 April 2004
Communications › Alarms/Indicators › Bilge Alarm
Issued 12 April 2004 Resolved
Install audible high level bilge alarm in accordance with 46 CFR 119.530
Due 12 May 2004
Resolved 15 April 2004
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 12 April 2004 Resolved
Make operable engine oil pressure gauges in wheel house 46 CFR 119.410.
Due 12 May 2004
Resolved 16 April 2004
Documentation › Markings/Placards › Capacity Marking
Issued 12 April 2004 Resolved
Properly label upper deck passenger limits in accordance with vessel's stability letter. 46 CFR 122.602(g)
Due 14 May 2004
Resolved 15 April 2004
Documentation › Markings/Placards › Warning Signs
Issued 12 April 2004 Resolved
Properly label all emergency escapes & water tight hatches. 46CFR122.606 & 122.610
Due 12 May 2004
Resolved 15 April 2004
Operations/Management › Drills/Instruction
Issued 6 November 2002 Resolved
CONDUCT MAN OVERBOARD AND FIRE DRILLS. LEGACY COMPONENT DESC: Man Overboard Recovery
Action required: 705 - Other - as specified
Due 31 May 2003
Resolved 29 May 2003
Resolution: DRILLS COMPLETED SAT.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 6 November 2002 Resolved
CONDUCT UNDERWAY MACHINERY AND AUXILLARY SYSTEMS TESTS.
Action required: 705 - Other - as specified
Due 31 May 2003
Resolved 29 May 2003
Resolution: TESTS SAT.
Communications › Radio Communications
Issued 6 November 2002 Resolved
REPLACE EPIRB HYDROSTATIC RELEASE. LEGACY COMPONENT DESC: EPIRB
Action required: 705 - Other - as specified
Due 31 May 2003
Resolved 29 May 2003
Resolution: HYDROSTATIC RELEASE REPLACED.
Fire Fighting › Fire Hydrants
Issued 6 November 2002 Resolved
PROVIDE SPANNER WRENCHES FOR ALL FIRE STATIONS.
Action required: 705 - Other - as specified
Due 31 May 2003
Resolved 29 May 2003
Resolution: WRENCHES INSTALLED.
Navigation › Emergency Steering
Issued 6 November 2002 Resolved
POST INSTRUCTIONS FOR OPERATION OF EMERGENCY STEERING.
Action required: 705 - Other - as specified
Due 31 May 2003
Resolved 29 May 2003
Resolution: INSTRUCTIONS POSTED.
Engineering › Fuel Oil Service System
Issued 6 November 2002 Resolved
INSTALL EMERGENCY FUEL SHUT OFF TO BE ACCESSED FROM OUTSIDE THE SPACE FOR THE BOW THRUSTER. LEGACY COMPONENT DESC: Valve, Control
Action required: 705 - Other - as specified
Due 31 May 2003
Resolved 29 May 2003
Resolution: SHUTDOWN INSTALLED.
Fire Fighting › Ventilation Systems
Issued 6 November 2002 Resolved
PROVIDE VENTILATION COVERS FOR EMERGENCY GENERATOR ROOM.
Action required: 705 - Other - as specified
Due 31 July 2003
Resolved 14 April 2004
Resolution: COVERS PROVIDED.
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 19 March 2002 Resolved
Test system with pressure to activate the main engines, gen sets and ventilation shutdowns. Engineroom nozzles must be capped to build back pressure to make system operate with test bottle. Weight Halon storage cylinder. LEGACY COMPONENT DESC: Operating Controls
Action required: 705 - Other - as specified
Due 19 April 2002
Resolved 29 March 2002
Lifesaving
Issued 5 November 2001 Resolved
CONDUCT MAN OVERBOARD AND FIRE DRILLS AT THE START OF THE SPRING OPERATING SCHEDULE.
Condition: Unknown
Due 30 May 2002
Resolved 23 July 2002
Resolution: WENT ON BOARD AND CONDUCTED FIRE AND MAN OVERBOARD DRILLS.
Construction/Loadline
Issued 19 November 1996 Resolved
FREE UP DECK HATCH #9 VOID SPACE.
Condition: Unknown
Due 19 November 1996
Resolved 19 November 1996
Fire Fighting
Issued 19 November 1996 Resolved
REPLACE #1 FIRE HOSE.
Condition: Unknown
Due 19 November 1996
Resolved 19 November 1996
Accommodation/Occupational Safety
Issued 19 November 1996 Resolved
PROVE PROPER OPERATION OF COMPRESSOR AND AIR RECEIVER RELIEF VALVES.
Condition: Unknown
Due 19 November 1996
Resolved 19 November 1996
Lifesaving
Issued 19 November 1996 Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE CONDUCT UNDERWAY FIRE , ABANDONSHIP AND MAN OVERBOARD DRILLS.
Condition: Unknown
Due 19 November 1996
Resolved 19 November 1996
Lifesaving
Issued 8 November 1995 Resolved
CONDUCT UNDERWAY FIRE AND BOAT DRILLS PRIOR TO THE START OF THE NEXT OPERATING SEASON BUT NOT LATER THAN 01MAY96.
Condition: Unknown
Due 8 November 1995
Resolved 8 November 1995
Engineering
Issued 8 November 1995 Resolved
RECONNECT LOOSE SOLENOID WIRE TO STARBOARD MAIN ENGINE.
Condition: Unknown
Due 8 November 1995
Resolved 8 November 1995
Engineering
Issued 8 November 1995 Resolved
REMOVE SECTION OF PVC OIL BREATHER LINE TO STARBOARD MAIN ENGINE.
Condition: Unknown
Due 8 November 1995
Resolved 8 November 1995
Engineering
Issued 8 November 1995 Resolved
RELOCATE FUEL FILTER GAUGE IN BOW THRUSTER COMPARTMENT AWAY FROM ACCESS LADDER.
Condition: Unknown
Due 8 November 1995
Resolved 8 November 1995
Engineering
Issued 8 November 1995 Resolved
MAKE PERMANENT REPAIR TO LEAKING BOWTHRUSTER HYDRAULIC LINE IN THE #5 VOID SPACE.
Condition: Unknown
Due 8 November 1995
Resolved 8 November 1995
Engineering
Issued 8 November 1995 Resolved
MAKE PERMANENT REPAIR TO STARBOARD FUEL FILL LINE LOCATED IN THE STEERING COMPARTMENT.
Condition: Unknown
Due 8 November 1995
Resolved 8 November 1995
Engineering
Issued 29 March 1995 Resolved
PROVIDE GUARD FOR BELT AND PULLY AT BOW THRUSTER.
Condition: Unknown
Due 29 March 1995
Resolved 29 March 1995
Lifesaving
Issued 29 March 1995 Resolved
CONDUCT UNDERWAY DRILLS.
Condition: Unknown
Due 29 March 1995
Resolved 29 March 1995
Engineering
Issued 22 April 1993 Resolved
TEST PROPER OPERATION OF OVERSPEED SHUTDOWNS FOR MAIN ENGINES (2) AND SHIP SERVICE GENERATORS (2).
Condition: Unknown
Due 22 April 1993
Resolved 22 April 1993
Engineering
Issued 22 April 1993 Resolved
INSTALL REMOTE OPERATION FOR FUEL OIL TANK VALVE FOR EMERGENCY GENERATOR FUEL TANK.
Condition: Unknown
Due 22 April 1993
Resolved 22 April 1993
Navigation
Issued 22 April 1993 Resolved
PROVE PROPER OPERATION OF FORWARD MASTHEAD LIGHTS.
Condition: Unknown
Due 22 April 1993
Resolved 22 April 1993
Lifesaving
Issued 22 April 1993 Resolved
CONDUCT EMERGENCY DRILLS.
Condition: Unknown
Due 22 April 1993
Resolved 22 April 1993
Navigation
Issued 22 April 1993 Resolved
PROVE PROPER OPERATION OF COMMUNICATION SYSTEM INSTALLED IN EMERGENCY STEERING ROOM, NAMELY: SOUND POWERED TELEPHONE.
Condition: Unknown
Due 22 April 1993
Resolved 22 April 1993
Lifesaving
Issued 1 May 1992 Resolved
Conduct man overboard, fire & abandon ship drills in the presence of a USCGMarine Inspector.
Condition: Unknown
Due 1 May 1992
Resolved 1 May 1992
Fire Fighting
Issued 14 February 1990 Resolved
CONDUCT COMPONENT TESTS OF FIXED HALON SYSTEM FOR ENGINE ROOM, INCLUDING WEIGHING OF BOTTLES AND TESTING OF TIME DELAYS, ALARMS AND PULLS.
Condition: Unknown
Due 14 February 1990
Resolved 14 February 1990
Fire Fighting
Issued 14 February 1990 Resolved
CONDUCT HYDROSTATIC TEST OF FIRE MAIN SYSTEM AND FIRE HOSES IN PRESENCE OF CG MARINE INSPECTOR.
Condition: Unknown
Due 14 February 1990
Resolved 14 February 1990
Fire Fighting
Issued 14 February 1990 Resolved
REPAIR FIRE DETECTION SENSOR IN ENGINE ROOM.
Condition: Unknown
Due 14 February 1990
Resolved 14 February 1990
Electrical
Issued 14 February 1990 Resolved
REPAIR AMMETER AND GOVERNOR CONTROL SWITCH FOR #2 GENERATOR.
Condition: Unknown
Due 14 February 1990
Resolved 14 February 1990
Lifesaving
Issued 14 February 1990 Resolved
PROVIDE SIX ORANGE HAND FLARES.
Condition: Unknown
Due 14 February 1990
Resolved 14 February 1990
Navigation
Issued 28 February 1989 Resolved
REPAIR BELL ON TELEPHONE IN STEERING COMPARTMENT AND MAKE OPERATIONAL FROM ALL OTHER STATIONS.
Condition: Unknown
Due 28 February 1989
Resolved 28 February 1989
Navigation
Issued 28 February 1989 Resolved
REPAIR DEPTH SOUNDER ON BRIDGE.
Condition: Unknown
Due 28 February 1989
Resolved 28 February 1989
Fire Fighting
Issued 15 August 1988 Resolved
PROVIDE TWO ADDITIONAL CREW, TO BE STATIONED IN THE VICINITY OF FIRE SCREENDOORS ON MAIN DECK AND 01 DECK, FOR THE PURPOSE OF OPERATING SAID DOORS IN THE EVENT OF FIRE EMERGENCY, UNTIL PERMANENT REPAIRS ARE EFFECTED TO DOOR HOLDS/ RELEASES.
Condition: Unknown
Due 15 August 1988
Resolved 15 August 1988

Casualty record · 2

27 June 2006Routine · role: Involved in a Marine Casualty · activity 2695377
21 October 2007Routine · role: Involved in a Marine Casualty · activity 3085444
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.