Records from 1988 to 2025. Most recent: inspection, 11 June 2025.
Documentation record
Registered dimensions (L × B × D)32.2 ft × 10.1 ft × 3.3 ft
Registered tonnagegross 9 / net 7
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderPAYNE & FRANKLIN, INC. · NORTH KINGSTOWN, RI, UNITED STATES · built 1988
Hull materialAluminum
PropulsionGasoline Outboard
Hull shapeBox
Hull configurationMonohull
Hailing portBOSTON, MA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 10 March 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it9 - Simplified, Gross Ton
7 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 42
11 June 2025
COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8120090
24 April 2024
Internal Structural Exam · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7887052
12 June 2023
Internal Structural Exam · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7694653
18 August 2020
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7036166
13 June 2019
Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6712147
6 May 2019
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6677664
19 June 2018
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6448237
13 June 2017
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6174257
15 June 2016
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5907288
18 June 2014
Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4892956
12 June 2012
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4341904
11 May 2012
Deficiency Check · Simplified Stability Test
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4308272
13 December 2011
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4207419
30 March 2010
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3707043
10 June 2008
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3232915
13 June 2007
Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2960193
14 June 2006
Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2679360
1 May 2006
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2638010
15 June 2005
COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2391127
16 June 2004
Deficiency Check · Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2097979
10 June 2003
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1814181
1 May 2002
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1611176
9 April 2002
Administrative Inspection
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1602803
6 June 2001
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1362270
10 April 2001
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1063094
10 May 2000
COI Inspection · Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1413729
25 May 1999
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 804675
10 June 1998
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1126172
4 June 1997
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1109777
12 June 1996
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1090847
15 May 1996
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1088199
7 June 1995
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1186306
29 June 1994
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1136758
17 June 1993
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 825694
9 July 1992
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1257259
10 June 1992
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 946643
11 June 1991
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1225555
29 May 1991
Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 901642
25 April 1991
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 914831
31 May 1990
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 924732
22 May 1989
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1203930
24 May 1988
Initial Certification
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 891813
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 June 2025
Resolved
Each ring life buoy with a floating waterlight must have a lanyard of at least 910 millimeters (3 feet) in length, but not more than 1,830 millimeters (6 feet), securing the waterlight around the body of the ring life buoy.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2025
Resolved 16 July 2025
Resolution: Operator replaced lanyard for floating waterlight, objective evidence sent.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 11 June 2025
Resolved
The discharge ends of fuel tank vent pipes must be fitted with removable flame screens or flame arresters with a single screen of corrosion resistant wire of at least 30 × 30 mesh. The port flame screen was not installed. Install suitable flame screen to the satisfaction of the marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2025
Resolved 16 July 2025
Resolution: Operator replaced flame screen, objective evidence sent.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 June 2025
Resolved
An adult life jacket must be provided for each person carried on board a vessel. 5 life jackets were found to be non-serviceable. Life jackets removed from service and destroyed. Vessel was carrying in excess, so no new life jackets were required.
Action required: 10 - Deficiency Rectified
Due 25 June 2025
Resolved 25 June 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 June 2019
Resolved
A submersible electric bilge pump may be used provided a positive shutoff valve is installed at the hull penetration. No valve is installed at the hull penetration.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 July 2019
Resolved 25 June 2019
Resolution: Valve was installed at thru hull.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 19 June 2014
Resolved
Mast light is inoperable. Fix light and prove proper operation. 46 CFR 176.25-40
Action required: 705 - Other - as specified
Due 2 July 2014
Resolved 2 July 2014
Resolution: Light was renewed and tested. All Sat.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 19 June 2014
Resolved
The lifeline on ring buoy is worn and broken. Replace ring buoy.
Action required: 705 - Other - as specified
Due 2 July 2014
Resolved 2 July 2014
Resolution: Ring Buoy was renewed.
Communications › Alarms/Indicators › Bilge Alarm
Issued 19 June 2014
Resolved
Visual high level bilge alarm is inoperable. Prove proper operation.
Action required: 705 - Other - as specified
Due 2 July 2014
Resolved 2 July 2014
Resolution: Bilge alarm was corrected, and tested. All Sat.
Documentation › Certificates/Documents › Stability Letter
Issued 13 December 2011
Resolved
Vessel has not verified compliance with new AAWP (185lb) standard. Total persons allowed on board as per the current COI is now reduced from 31 to 23.
Due 1 June 2012
Resolved 11 May 2012
Resolution: Owner has opted to reduce persons on board to 23.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 16 June 2004
Resolved
Update expired items in first aid kit.
Action required: 705 - Other - as specified
Due 30 June 2004
Resolved 7 July 2004
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 16 June 2004
Resolved
Provide Flashlight and mount by operator station.
Action required: 705 - Other - as specified
Due 30 June 2004
Resolved 7 July 2004
Electrical › Electrical Distribution System (service) › Switch
Issued 16 June 2004
Resolved
Label bilge alarm switch to be "ON" while operating.
Action required: 705 - Other - as specified
Due 30 June 2004
Resolved 7 July 2004
Lifesaving
Issued 10 May 2000
Resolved
MAKE VESSEL AVAILABLE WITH CREW TO CONDUCT UNDERWAY DRILLS TO THE SATISFACTION OF AN ATTENDING USCG MARINE INSPECTOR.
Condition: Unknown
Due 21 June 2000
Resolved 26 June 2000
Fire Fighting
Issued 10 June 1992
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 18 June 1992
Resolved 18 June 1992
Lifesaving
Issued 11 June 1991
Resolved
PRIOR TO CARRYING PASSENGERS CONDUCT EMERGENCY DRILLS WITH OPERATORS AND DECKHANDS AS OUTLINED IN NAVIC 1-91 DTD 20 FEB 91 IN PRESENCE OF COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 11 June 1991
Resolved 11 June 1991