Records from 1988 to 2025. Most recent: inspection, 14 July 2025.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 54
14 July 2025
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8185699
8 April 2025
Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8106576
8 April 2025
Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8108153
29 July 2024
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7969403
6 July 2023
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7734814
17 April 2023
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7670238
7 July 2022
DAPI Audit · Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7490449
3 August 2021
Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7272609
3 August 2021
Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7276934
6 April 2021
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7164673
9 September 2020
Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7053956
15 August 2019
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6769595
18 April 2019
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6570239
1 October 2018
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6542334
16 November 2016
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6042405
15 August 2016
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5973027
27 August 2015
COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5227723
12 June 2014
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 4886674
20 September 2011
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 4150630
9 November 2010
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3887734
27 September 2010
COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3858341
17 November 2008
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3364523
9 September 2008
Simplified Stability Test · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3320811
30 January 2008
Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3139122
24 September 2007
Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3064682
28 September 2006
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2788805
28 September 2005
Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2507332
29 October 2004
Internal Structural Exam · Hull Examination
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2229491
25 October 2004
Annual Inspection
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2224793
15 October 2003
Annual Inspection · MARPOL Annex V Examination
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1925794
1 November 2002
Hull Examination · Internal Structural Exam
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1697445
30 September 2002
MARPOL Annex V Examination · Re-Inspection
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1680262
6 October 2000
MARPOL Annex V Examination · COI Inspection · Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1365986
26 August 1999
MARPOL Annex V Examination · Re-Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1455760
21 May 1999
Deficiency Check · Plan Review "T" Boat
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1406516
10 May 1999
Plan Review "T" Boat
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1130001
8 April 1999
Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1411869
27 August 1998
Re-Inspection · MARPOL Annex V Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 797642
28 August 1997
COI Inspection · MARPOL Annex V Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 785026
11 April 1997
Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1098047
28 August 1996
MARPOL Annex V Examination · Re-Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 938944
23 May 1996
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 938059
13 August 1995
MARPOL Annex V Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 878125
1 July 1994
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 864680
15 April 1994
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 865908
20 July 1993
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 832514
3 June 1992
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 947837
8 April 1992
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1258355
2 July 1991
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 949613
25 June 1990
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1222040
27 March 1990
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1244724
26 June 1989
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1339946
2 July 1988
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1202505
3 May 1988
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 890434
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 7 July 2022
Resolved
The deck aft of the engine hatch supports were wasted. Repair deck. IAW 46 CFR 177.300.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 August 2022
Resolution: O/O hired professional that repaired the deck to the satisfaction of MI.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 7 July 2022
Resolved
A vessel must carry either a first –aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. First aid kit had expired eyewash. 46 CFR 184.710.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 July 2022
Resolution: O/O purchased new eye wash with expiration date of 2024-04-01.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 July 2022
Resolved
Each life jacket must be marked with Type I retroreflective material approved in 46 CFR 164.018. Two child size PFD’s needed retroreflective tape replaced. IAW: 46CFR.185.604(h)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 July 2022
Resolution: O/O purchased new Type I retroreflective material approved in 46 CFR 164.018 and installed on PFD's.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 3 August 2021
Resolved
The PJYC has 03 vessels and they were not completing or logging abandon ship drills.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 September 2021
Resolved 3 August 2021
Resolution: Completed abandon ship drills on annual inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 August 2021
Resolved
The lifering is required to have a 60' lifeline attached. The vessel did not and only had about a 12' lifeline.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 September 2021
Resolved 1 September 2021
Resolution: Installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 August 2021
Resolved
The vessel is required to have a 3-6 foot 5/8" (min) line attached to the waterlight and around the body of the lifering with a quick release clip. The vessel had a piece of string tied to the lifering and waterlight.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 September 2021
Resolved 1 September 2021
Resolution: Installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 August 2021
Resolved
The vessel suffered a marine casualty during the inspection. The vessels shaft coupling came loose disabling any forward or backward abilities. Issued requirement to complete repairs and have an MI attend.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 September 2021
Resolved 5 August 2021
Resolution: MI attended and conducted sea trials. All sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 9 September 2020
Resolved
Create individual note books IAW SLIS [name withheld] FOR VESSELS OPERATING AS LAUNCHES containing the following:
1. The Special Consideration's letter
2. The vessel's COI (Copy)
3. The vessel's state registration (Copy)
4. The Vessel's Stability Letter
5. Emergency procedures for man overboard and fire onboard
6. passenger safety orientation
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2020
Resolved 11 September 2020
Resolution: Notebooks to comform with SLIS [name withheld] FOR VESSELS OPERATING AS LAUNCHES created and checked out and placed on the vessel's while underway.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 September 2020
Resolved
Life ring identified in wastyed and unserviceable condition with grab lines frayed and retro reflective tape worn and missing. Replace lifering.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 9 September 2020
Resolved 9 September 2020
Resolution: Life ring replaced prior to the completion of the inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 September 2020
Resolved
Floating electric water light was identified with the wrong 6V battery installed. Battery installed was not listed on the light container. When pulling the battery to inspect noted a connection sleeve missing for the floating electric water light.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 9 September 2020
Resolved 9 September 2020
Resolution: Old light instaled was an SM2 ACR. Company had new SM3 modeles available and installed prior to the completion of the inspection.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 23 September 2015
Resolved
Provide copy of proof of registration. No COD req'd, but do need to see Registration.
Action required: 705 - Other - as specified
Due 30 September 2015
Resolved 23 September 2015
Resolution: Rec'd fax copy of registration, exp 3/31/2018
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 23 September 2015
Resolved
Repair crack in pax seating on port side of vessel near embarkation area.
Action required: 705 - Other - as specified
Due 14 October 2015
Resolved 23 September 2015
Electrical › Electric Supply System (service) › Battery Installation
Issued 20 September 2011
Resolved
Replace battery box cover, corrected on the spot
Condition: Placed in Improper Service
Due 21 September 2011
Resolved 21 September 2011
Resolution: corrected on the spot
Electrical › Electrical Distribution System (service) › Wiring
Issued 29 September 2010
Resolved
Remove dead end wiring in the forward compartment.
Action required: 705 - Other - as specified
Due 29 October 2010
Resolved 18 October 2010
Resolution: MI attended vessel and noted requirement had been addressed.
Engineering › Sea-water System (primary cooling) › Valve
Issued 29 September 2010
Resolved
Prove proper operation of the sea water intake valve prior to carrying passengers for hire.
Action required: 705 - Other - as specified
Due 18 October 2010
Resolved 18 October 2010
Resolution: MI attended vessel and noted requirement had been addressed.
Engineering › Steering Gear System › Linkage
Issued 27 September 2010
Resolved
Remove inoperable shift cable in engine compartment.
Action required: 705 - Other - as specified
Due 29 October 2010
Resolved 18 October 2010
Resolution: MI attended vessel and noted requirement had been addressed.
Stability › Incline Test › General
Issued 30 January 2008
Resolved
Complete a satisfactory stability test no later than next drydock period.
Action required: 705 - Other - as specified
Resolved 9 September 2008
Resolution: CONDUCTED SST
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 24 September 2007
Resolved
Renew retroreflective tape on 18 adult PFD's. Due to history of non-compliance with this particular requirement, removed PFD's from vessel and limited total person count to 4 adults and 4 children.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 September 2007
Resolved 28 September 2007
Resolution: Corrected
Electrical › Electrical Distribution System (service) › Switch
Issued 24 September 2007
Resolved
Permanently mount main 12VDC power switch in helm console.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 September 2007
Resolved 28 September 2007
Resolution: Corrected
Electrical › Electrical Distribution System (service) › Overcurrent Device
Issued 24 September 2007
Resolved
Provide adequate 12 VDC overcurrent protection for both helm/house feeder circuits, as near as possible to the battery.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 September 2007
Resolved 9 October 2007
Resolution: Corrected
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 24 September 2007
Resolved
Clean engineroom bilges
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 September 2007
Resolved 9 October 2007
Resolution: Corrected
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 24 September 2007
Resolved
Provide fire-proof shield at engineroom f/o shut off valves.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 September 2007
Resolved 9 October 2007
Resolution: Corrected
Fire Fighting › Fire Bucket › Availability
Issued 28 September 2005
Resolved
Provide 3 fire buckets with lanyards.
Due 15 October 2005
Resolved 15 October 2005
Resolution: Per fax ltr fm O/O, ltr scanned into documents for this activity.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 28 September 2005
Resolved
Update first aid kit.
Due 15 October 2005
Resolved 15 October 2005
Resolution: Per fax ltr fm O/O, ltr scanned into documents for this activity.
Operations/Management › Drug and Alcohol Testing
Issued 15 October 2003
Resolved
Provide proof of drug testing program. LEGACY COMPONENT DESC: Employee Coverage
Due 15 October 2003
Resolved 15 October 2003
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 15 October 2003
Resolved
Conduct fire and boat drills at the begining of next operating season and log in logbook.
Due 1 May 2004
Resolved 25 October 2004
Communications › Radio Communications
Issued 30 September 2002
Resolved
Provide FCC radio station license. LEGACY COMPONENT DESC: VFH Radiotelephone
Due 18 October 2002
Resolved 15 October 2003
Resolution: Vessel has been sold to new owner. Will be applied for by new owner.
Documentation › Certificates/Documents
Issued 30 September 2002
Resolved
Provide copy of NY State Registration
Due 7 October 2002
Resolved 3 October 2002
Resolution: NY State registration provided for new vessel owner. COI/party details changed to reflect change in ownership.
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 30 September 2002
Resolved
Provide emergency instruction list IAW 46 CFR 185.510/185.520.
Condition: Unknown
Due 7 October 2002
Resolved 7 October 2002
Resolution: Written and posted.
Lifesaving › Lifebuoys
Issued 30 September 2002
Resolved
Renew detachable clip on ring buoy waterlight. Clip too small for line.
Condition: Improper Installation
Due 7 October 2002
Resolved 7 October 2002
Resolution: Larger clip installed.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 30 September 2002
Resolved
Provide floatable line for ring buoy IAW 46 CFR 180.70.
Condition: Placed in Improper Service
Due 7 October 2002
Resolved 7 October 2002
Resolution: Floatable, yellow polypropeline line attached.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 30 September 2002
Resolved
Renew waterlight battery.
Due 7 October 2002
Resolved 7 October 2002
Resolution: New 6V battery installed.
Communications › Radio Communications
Issued 30 September 2002
Resolved
Update emergency broadcast placard. LEGACY COMPONENT DESC: VFH Radiotelephone
Due 18 October 2002
Resolved 15 October 2003
Resolution: Vessel has been sold to new owner. Have advised new owner to provide and post.
Engineering › Steering Gear System
Issued 30 September 2002
Resolved
Provide auxiliary steering mechanism.
Due 7 October 2002
Resolved 7 October 2002
Resolution: Metallic tiller arm fabricated and stowed on vessel.
Engineering
Issued 6 October 2000
Resolved
DEMONSTRATE SATISFACTORY OPERATION OF ENGINE AND CONTROLS PRIOR TO CARRYINGPASSENGERS.
Condition: Unknown
Due 6 January 2002
Resolved 15 October 2003
Lifesaving
Issued 6 October 2000
Resolved
DEMONSTRATE CREW PROFICIENCY VIA MAN OVERBOARD, FIRE & ABANDONSHIP DRILLS PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 6 January 2002
Resolved 15 October 2003
Fire Fighting
Issued 10 May 1999
Resolved
CONDUCT INSTALLATION INSPECTION AND TESTS FOR PRE-ENGINEERED HALON SYSTEM
Condition: Unknown
Due 10 May 1999
Resolved 10 May 1999
Engineering
Issued 8 April 1999
Resolved
RENEW CUTLASS BEARING.
Condition: Unknown
Due 15 April 1999
Resolved 15 April 1999