CAROLINA BELLE

CAROLINA BELLE is a 1988 passenger vessel (inspected). The Coast Guard has recorded 31 inspections since 2016, most recently in February 2026, along with 47 deficiencies, 1 operational control and 9 casualty investigations between 2005 and 2026.

Records from 2005 to 2026. Most recent: inspection, 22 February 2026.

Built
1988
Last inspected
22 February 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls, the casualty record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 22 February 2026
…with no type recorded5
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDD7269
310043
Flag
UNITED STATES
Maury page id
psix-310043

Documentation record

Registered dimensions (L × B × D)71.6 ft × 24.0 ft × 7.7 ft
Registered tonnagegross 35 / net 24
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCHESAPEAKE SHIPBUILDING · SALISBURY, MD, UNITED STATES · built 1988
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portCHARLESTON, SC
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 4 May 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it35 - Regulatory (Subpart C or D), Gross Ton
24 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

31 inspections, each with its date, unit and type; 47 deficiencies with the resolution recorded against each; 1 operational control with the dates imposed and removed; 9 casualty investigations, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 31

22 February 2026 In-Service Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8313962
21 February 2026 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8314836
2 January 2026 Drydock Exam · Internal Structural Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8289168
15 July 2025 Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8186528
31 March 2025 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8102614
4 November 2024 Damage Survey
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8029132
16 May 2024 COI Inspection · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7913433
25 April 2024 Administrative Inspection · Damage Survey
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7901081
2 January 2024 Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7847164
19 October 2023 Deficiency Check · In-Service Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7811351
25 May 2023 In-Service Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7696480
8 July 2022 Deficiency Check · COI Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7500618
11 January 2022 Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7378362
16 August 2021 Annual Inspection · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7285908
23 June 2021 Damage Survey
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7234099
23 June 2021 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7240175
9 February 2021 Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7137928
12 January 2021 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7123436
20 July 2020 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7010928
6 June 2020 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7136082
26 August 2019 Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6795390
7 January 2019 Hull Examination · Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6606936
27 August 2018 Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6526572
28 June 2018 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6570551
8 May 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6408955
29 August 2017 Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6254822
31 May 2017 COI Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6159800
9 February 2017 Drydock Exam · Hull Examination · Examination of Repairs
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6084703
16 November 2016 Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6042586
11 October 2016 Annual Inspection · DAPI Audit
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6019105
4 January 2016 Administrative Inspection · Examination of Repairs · Damage Survey
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5790514

Deficiency record · 47

09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 15 July 2025 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected. Spaces may be examined to see that there is no excessive accumulation of oil. Vessel had excessive oil accumulation in the bilge of the engine room. Correct prior to the carriage of passengers. 46 CFR 115.830
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 July 2025
Resolution: Engine room has been cleaned to the satisfaction of the attending marine inspectors.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 July 2025 Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Various electrical hazards exist throughtout the vessel including loose paneling on the switchboard in the engine room, missing wire ties used for securing wiring to the overhead in the engine room, and a loose junction box above the air conditioning unit. 183.01-15(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 July 2025
Resolution: O/O fixed switchboard paneling and tied off lights in the engine room. Additionally, AC unit is currently out of operation and breakers have been tagged out.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 15 July 2025 Resolved
The vessel's bilges and voids shall be kept pumped to minimum content at all times. Lazarette contains an excessive amount of water. Cite: Stability letter.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 July 2025
Resolution: Lazarette has been pumped to the satisfaction of the attending marine inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 15 July 2025 Resolved
Suitable covers, guards, or rails shall be installed in way of all exposed and hazardous places such as gears, machinery, etc. The guard around the starboard side generator belt is not suitable as it is not permanently affixed to the generator.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2025
Resolved 31 July 2025
Resolution: O/O sent Sector Charleston a picture of a permanently installed guard over the starboard side generator.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 July 2025 Resolved
Unless other means are provided to ensure that a potential waste receptacle fire would be limited to the receptacle, waste receptacles must be constructed of noncombustible materials with no openings in the sides or bottom. There are currently combustible plastic trash cans located throughout the vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2025
Resolved 30 July 2025
Resolution: O/O replaced combustible plastic trash cans with metal trash cans.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 15 July 2025 Resolved
At each initial and subsequent inspection for certification, reinspection and at every other vessel inspection the marine inspector shall require that all observed unsafe practices and hazardous situations be corrected. A window near the port bow is cracked.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2025
Resolved 30 July 2025
Resolution: O/O replaced cracked window.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 November 2024 Resolved
The construction and arrangement of the vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. 46CFR177.100 Vessels mooring bits are damaged.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 December 2024
Resolved 21 November 2024
Resolution: New mooring bits were welded to the vessel. Deficiency cleared.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 16 May 2024 Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. You must contact the cognizant OCMI to schedule an inspection at a time and place which he or she approves. No written application is required. Vessel failed to schedule annual inspection required no later than 23FEB24. 46 CFR 176.500(b)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 May 2024
Resolution: New COI issued.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 23 November 2022 Resolved
Each connection to a conductor or terminal part of a conductor must be made within an enclosure and have either: a pressure type connector on each conductor, a solder lug on each connector, a splice made with a pressure type connector to a flexible lead or conductor, or a splice that is soldered, brazed, or welded to a flexible lead or conductor. The electrical under the operating station had dead end wires, that must be properly terminated.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 December 2022
Resolved 1 December 2022
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 23 November 2022 Resolved
Except on a vessel limited to day time operations, the compass must be illuminated. The vessel's compass was not illuminated. Limited to day time operations
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 December 2022
Resolved 28 November 2022
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 11 January 2022 Resolved
The owner intends to change out engines during this yard period. The old engine will be removed and the new one installed through a cut out on the starboard side shell of the vessel. Upon completion of the engine change out, the area cropped out must be inspected and then reinspected when fit up of the replacement is made and then throughout the welding process. Workmanship will be verified by an attending Coast Guard Marine Inspector through visual observation and witness an NDT Test to be agreed upon later.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 June 2022
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 11 January 2022 Resolved
Corp and renew the wasted section of bulkhead in the engine room, on the centerline separating the dry stores and the engine room space. Workmanship will be verified by an attending Coast Guard Marine Inspector through visual observation and witness an NDT Test to be agreed upon later.
Action required: 17 - Rectify deficiencies prior to departure
Due 20 April 2022
Resolved 18 February 2022
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 11 January 2022 Resolved
Corp and renew the wasted stiffener in way of the door frame on the port side, main deck. There should be sufficient material in the remaining portion of the member to permit sound attachment of the new metal. Workmanship will be verified by an attending Coast Guard Marine Inspector through visual observation of the workmanship.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 May 2024
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 16 August 2021 Resolved
Each vessel must meet the applicable requirements in Subchapter S of this chapter. Swivel guide for the dogging hatch arm missing on Class I watertight door. Gasket is notched at the bottom, compromising watertight integrity. Replace swivel and gasket. 46 Old CFR 177.13-1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 August 2021
Resolved 24 November 2021
Resolution: A new dogging hatch arm was placed in service.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 16 August 2021 Resolved
Exhaust gas must not leak from the piping or any connections. The piping must be properly supported by noncombustible hangers or blocks. Port and starboard engine exhaust leaking.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 August 2021
Resolved 16 September 2021
Resolution: Fastenings for the exhaust flanges were tightened.
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 16 August 2021 Resolved
When using DSC techniques, coast stations and ship stations must use maritime mobile service identities (MMSI) assigned by the Commission or its designees. Vessel's DSC not properly configured. 47 CFR 80.103
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 August 2021
Resolved 14 December 2021
Resolution: DSC configured by local FCC rep. New station license issued.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 16 August 2021 Resolved
he Bridge-to-Bridge Act and the regulations of this part apply to the following vessels in the navigable waters of the United States: Every power-driven vessel of 20 meters or over in length while navigating. Vessel missing bridge to bridge certification. 47 CFR 80.1001
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 August 2021
Resolved 14 December 2021
Resolution: Bridge to bridge certificate issued by local FCC rep.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 August 2021 Resolved
Spanner wrenches must be provided for each fire hydrant required by this regulation. Existing vessels must comply with this requirement by January 18, 2017. Vessel missing spanner wrench for upper deck fire hose.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 August 2021
Resolved 14 December 2021
Resolution: Spanner wrench installed on upper deck fire hose.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 August 2021 Resolved
Each vessel must meet the applicable requirements in Subchapter S of this chapter. Vessel missing cap on ball valve located in engine room.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 August 2021
Resolved 14 December 2021
Resolution: valve capped with cap fitting.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 16 August 2021 Resolved
The general construction of the vessel shall be such as to minimize fire hazards insofar as reasonable and practicable. Vessel missing fire retardant insulation in the engine room overhead. 46 Old CFR 177.10-5
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 August 2021
Resolved 14 December 2021
Resolution: New fire retardent insulation installed in engine room overhead.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 August 2021 Resolved
All vessels shall be provided with an approved adult type life preserver for each person carried. Vessel missing 05 Adult Type I life preservers. 46 Old CFR 180.25-5
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 August 2021
Resolved 14 December 2021
Resolution: 05 new Type I PFDs were purchased and installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 June 2021 Resolved
Propulsion Machinery must be suitable in the type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements withou exceeding its designed limitiations. Vesssel experienced a complete shutdown of port engine while carrying 161 passengers in Charleston Harbor. Show proper operation of port engine prior to returning to service
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 June 2021
Resolution: Vessel proved proper operation of port engine
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 July 2020 Resolved
"L" vessels over 65 feet in accordance with Table 182.25-10(a) must be provided with 2 fixed power pumps. Bilge pump inoperable. Until pump is fixed, perform check of void spaces before getting underway each trip.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 August 2020
Resolved 16 August 2021
Resolution: Conducted satsifactory annual inspection and found both bilge pumps operable.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 July 2020 Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets. Life jacket stowage identification incorrect and needs to be updated to reflect correct life jacket count.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 August 2020
Resolved 7 August 2020
Resolution: Updated lifejacket stowage signs.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 27 July 2020 Resolved
Unless other means are provided to ensure that a potential waste receptacle fire would be limited to the receptacle, waste receptacles must be constructed of noncombustible materials with no openings in the sides or bottom. Please place "No Smoking" decals around vessel near waste receptacles as discussed.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 August 2020
Resolved 7 August 2020
Resolution: No Smoking signs placed above each waste receptacle onboard, no smoking added to the General Policies sign visible to passeners as they walk onboard, and added to the passenger safety orientation.
05 - Radio Communications › N/A - No Subsystem › Performance standards for radio equipment
Issued 26 August 2019 Resolved
Renew FCC safety certificate and show proper operation of DSC.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 December 2019
Resolution: A new FCC Safety cert was placed on the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 August 2019 Resolved
Place in service 24 children USCG approved Type I PFDs and 3 adult USCG approved Type I PFDs.
Action required: 10 - Deficiency Rectified
Due 26 August 2019
Resolved 26 August 2019
Resolution: New PFDs were placed on the vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 August 2019 Resolved
Mount high water alarm in #2 void space.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 December 2019
Resolution: The high water alarm was mounted in the #2 void space.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 26 August 2019 Resolved
Properly mount heat detection sensor and show proper operation.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 December 2019
Resolution: The heat detection sensor was mounted.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 August 2019 Resolved
Renew face plate for electrical box in dry stores.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 December 2019
Resolution: A new electrical face plate was placed on the outlet box.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 26 August 2019 Resolved
Show proper operation of emergency lighting.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 December 2019
Resolution: Emergency lighting in galley was repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 August 2019 Resolved
provide strain relief for shore tie cable run to main distribution box.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 December 2019
Resolution: The main bus tie was provided with strain relief.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 August 2018 Resolved
Fuel filter bowls not in compliance with 46CFR182.455
Condition: Improper Installation
Due 10 September 2018
Resolved 2 November 2018
Resolution: Replaced with approved
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 August 2018 Resolved
Bilge pump cable not permanently installed.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 September 2018
Resolved 4 September 2018
Resolution: Installed permanently
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 August 2018 Resolved
Globes missing on light fixtures
Due 10 September 2018
Resolved 4 September 2018
Resolution: Globes installed
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 August 2018 Resolved
Emergency light battery unsat (main deck fwd)
Due 10 September 2018
Resolved 4 September 2018
Resolution: Replaced battery
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 August 2018 Resolved
Breakers in A/C panel pinned together.
Due 10 September 2018
Resolved 4 September 2018
Resolution: Breakers installed properly
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 31 May 2017 Resolved
Replace 07 condemned child PFD's
Due 30 June 2017
Resolved 31 May 2017
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 31 May 2017 Resolved
Replace electrical outlet box on aft E/R bulkhead.
Due 30 June 2017
Resolved 29 August 2017
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 31 May 2017 Resolved
Demonstrate genset overspeeds are in working order.
Due 30 June 2017
Resolved 29 August 2017
Electrical › Electric Supply System (service) › Battery Installation
Issued 31 May 2017 Resolved
Replace wasted STBD battery box
Due 30 June 2017
Resolved 29 August 2017
Navigation › Piloting/Steering › US Coast Pilot
Issued 11 October 2016 Resolved
Update Coast Pilot
Due 11 November 2016
Resolved 16 November 2016
Navigation › Piloting/Steering › Marine Charts
Issued 11 October 2016 Resolved
Obtain current copy of marine chart for area of operation.
Due 11 November 2016
Resolved 15 November 2016
Electrical › Lighting (service) › Lighting Fixture
Issued 11 October 2016 Resolved
tighten lighting fixture in concession stand.
Due 11 November 2016
Resolved 15 November 2016
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 11 October 2016 Resolved
Replace broken electrical outlet cover on aft main deck.
Due 11 November 2016
Resolved 15 November 2016
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 11 October 2016 Resolved
Mark child PFD stowage area on main deck.
Due 11 November 2016
Resolved 15 November 2016
Construction/Loadline › Hull › Bottom Plating
Issued 4 January 2016 Resolved
Vessel is to transit to dry dock to make repairs to hull breaches/insets resulting from grounding. Vsl is not to carry passengeres until repairs completed.
Action required: 705 - Other - as specified
Due 18 January 2016
Resolved 22 January 2016

Casualty record · 9

28 March 2005Routine · role: Involved in a Marine Casualty · activity 2321965
15 November 2006Routine · role: Involved in a Marine Casualty · activity 2822042
23 April 2015Routine · role: Involved in a Marine Casualty · activity 5113957
31 December 2015Routine · role: Involved in a Marine Casualty · activity 5793504
6 June 2020Routine · role: Involved in a Marine Casualty · 2 injured · activity 7136082
23 June 2021Routine · role: Involved in a Marine Casualty · activity 7240175
30 June 2024Routine · role: Involved in a Marine Casualty · activity 8156308
31 March 2025Routine · role: Involved in a Marine Casualty · 1 injured · activity 8102614
21 February 2026Routine · role: Involved in a Marine Casualty · activity 8314836
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.