Records from 2016 to 2025. Most recent: inspection, 11 August 2025.
Inspection history · 16
11 August 2025
Type not recorded
No type recorded · USCGC BONITO (WPB 87341) · USCG Northeast District (CGD-NE) · Activity 8245018
21 April 2025
Deficiency Check · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8115966
19 March 2025
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8095986
11 April 2024
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7892586
3 April 2023
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7661524
16 March 2023
Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7651783
20 April 2022
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7434594
5 April 2021
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7168668
15 March 2021
Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7155355
27 May 2020
COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6960712
12 June 2019
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6713129
22 March 2019
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6750920
31 May 2018
Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6429884
2 March 2017
Drydock Exam · Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6281988
23 February 2017
Administrative Inspection · Construction Oversight · Plan Review "T" Boat
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6106599
11 April 2016
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5851192
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 April 2025
Resolved
An adult Type-1 life jacket must be provided for each person carried on board a vessel. Vessel has total capacity for 17 persons. MI Observed 16 adult lifejackets. Provide evidence an additional life jacket is placed in service for the vessel so total count is 17 Adult Type-1 Life Jackets onboard.
Vessel is operating within cold water until first friday before Memorial Day weekend restricted to Total Max Allowable people of 15.
46 CFR 180.71(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 April 2025
Resolution: Vessel provided documentation and picture evidence of 17 total Life Jackets and new one placed into service. See attached pictures.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 21 April 2025
Resolved
Vessels on a limited coast wise route must carry; Six hand red flare distress signals in accordance 46 CFR 160.021. and Six hand orange smoke distress signals approved in accordance with 46 CFR 160.037. MI observed 3 red / 3 smoke on board. For Limited Coastwise Route vessel must carry12 total 6 red / 6 smoke. Vessel is restricted to Lakes Bays and Sounds until evidence of appropriate level of flares onboard.
46 CFR 180.68(a)
Action required: 705 - Other - as specified
Resolved 21 April 2025
Resolution: Vessel provided documentation of purchase of additional 3 red and 3 orange smoke flares. See attached pictures.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 21 April 2025
Resolved
The EPIRB monthly test required by paragraph (a) shall be logged or otherwise documented. MI observed the vessel has not been competing required Monthly Tests on EPIRB. MI tested EPIRB during COI today. Vessel required to submit evidence of May 2025 Test log or other means of documentation.
46 CFR 185.728(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 May 2025
Resolution: Monthly log picture for May attached.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 21 April 2025
Resolved
Each vessel that operates beyond three miles from the coastline of the Great Lakes, must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate.MI Observed Hydrostatic Release unit with a date of expiry of April 2024. essel is restricted to Lakes Bays and Sounds until evidence of new Hydrostatic Release unit is installed.
– 46 CFR 180.64
Action required: 705 - Other - as specified
Resolved 1 May 2025
Resolution: new Hydrostatic release unit installed.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 11 April 2024
Resolved
"As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: (1) Charts..." Vessel did not have up-to-date charts.
46 CFR 184.420
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 June 2024
Resolution: Received satisfactory photographic evidence.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 11 April 2024
Resolved
"Portable watertight containers for distress flares... shall be clearly marked... 'DISTRESS SIGNALS.'" Container is not properly marked.
46 CFR 185.614
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 May 2024
Resolution: Received satisfactory photographic evidence.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 April 2024
Resolved
"Vessel must carry... First Aid Kit approved... or w/ equivalent contents." Expired items found in First Aid Kit.
46 CFR 184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 May 2024
Resolution: Received satisfactory photographic evidence.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 April 2024
Resolved
"The installation and location must be to the satisfaction of Officer in Charge, Marine Inspection." Mounts were not installed for fire extinguishers.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 May 2024
Resolution: Received satisfactory photographic evidence.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 12 June 2019
Resolved
Demonstrate bilge high level alarm.
Cite: 46CFR182.530
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 June 2019
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 12 June 2019
Resolved
Vessel must provide flares in accordance with 46CFR180.68.
Cite: 46CFR180.68
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 June 2019
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 12 June 2019
Resolved
Vessel must provide new hydrostatic release unit for EPIRB.
Cite: 46CFR180.64
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 June 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 June 2019
Resolved
Vessel must provide a functional Ring Buoy Float Light.
Vessel must attach float light in acordance with 46CFR180.70.
Cite: 46CFR180.70
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 June 2019
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 12 June 2019
Resolved
Vessel must mark each life float paddle must with vessel name.
Cite: 46CFR185.604
Vessel must attach Painter line to body of life float via corrosion resistant clip.
Cite: 46CFR180.137
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 June 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 June 2019
Resolved
Vessel's master must be familiar with the charactertics of the vessel and demonstrate to the Coast Guard.
Cite: 46CFR15.405
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 June 2019
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 12 June 2019
Resolved
Vessel's toilet line is not connected to the sewage holding tank, the valve must be secured in accordance with 33CFR159.7.
Cite: 33CFR159.7
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2019
Resolved 20 June 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 June 2019
Resolved
Vessel must mark life preservers with current vessel name.
Cite: 46CFR185.604
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2019
Resolved 20 June 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 June 2019
Resolved
Vessel's DAPI Program is incomplete, vessel must provide:
alcohol test kit, drug program company policy, crew list, and emergency hotline number in accordance with 46CFR16.
Cite: 46CFR Part16
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2019
Resolved 20 June 2019
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 12 June 2019
Resolved
Vessel must provide updated charts and publications in accordance with 46CFR184.420.
Cite: 46CFR184.420
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2019
Resolved 11 July 2019
Resolution: Provided updated charts and pubs.
14 - Pollution Prevention › 145 - MARPOL Annex V › Placards
Issued 12 June 2019
Resolved
Vessel must provide MARPOL Placard.
Cite: 33CFR151.59
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2019
Resolved 20 June 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 June 2019
Resolved
Vessel must provide first aid kit in accordance with 46CFR160.041-4(b).
Cite: 46CFR160.041-4(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2019
Resolved 20 June 2019
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 12 June 2019
Resolved
Vessel must provide drill logs in accordance with 46CFR185.420.
Cite: 46CFR185.420
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2019
Resolved 20 June 2019
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 12 June 2019
Resolved
Vessel must provide navigation lights in accordance with the Navigation Rules.
Cite: Navigation Rules (NAV RULES)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2019
Resolved 20 June 2019
09 - Working and Living Conditions › 092 - Working Conditions › Ropes and wires
Issued 12 June 2019
Resolved
Due to corrosion wastage of cables ends vessel must replace cables for crows nest.
Cite: 46CFR177.800
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2019
Resolved 11 July 2019
Resolution: Vessel replaced cables with new stainless steel cable and properly attached to the vessel.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 12 June 2019
Resolved
Vessel must complete fire drill with Coast Guard.
Cite: 46CFR185.524
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 June 2019
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 12 June 2019
Resolved
Vessel must complete Man Overboard drills with Coast Guard.
Cite: 46CFR185.520
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 June 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 June 2019
Resolved
Vessel has several prior to carry passenger deficiencies with regard to lifesaving equipment and control of water in the bilge (high level alarms). Vessel is not ready for inspection. Vessel to go through entire vessel and prepare for inspection prior to USCG Marine Inspectors returning.
Cite: 46CFR176.502
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 June 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 June 2019
Resolved
Vessel must provide emergency instructions in accordance with 46CFR185.510.
Cite: 46CFR185.510
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 July 2019
Resolved 11 July 2019
Resolution: Vessel provided emergency instructions.
Navigation › Piloting/Steering › Marine Charts
Issued 31 May 2018
Resolved
Vessel must carry adequate and up-to-date charts. Vessel did not have current charts on board. Vessel must provide current charts.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2018
Resolved 1 June 2018
Resolution: Vessel rep provided new charts.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 31 May 2018
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2018
Resolved 1 June 2018
Resolution: Vessel rep provided up to date navigation publications.
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 11 April 2016
Resolved
Lock MSD when operating.
Action required: 705 - Other - as specified
Due 25 April 2016
Resolved 11 April 2016
Resolution: MSD was locked during inspection.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 11 April 2016
Resolved
Mast head light inoperable.
Condition: Invalid
Action required: 705 - Other - as specified
Due 25 April 2016
Resolved 11 April 2016
Resolution: Mast head light was fixed during inspection.
Communications › Radio Communications › VHF Radiotelephone
Issued 11 April 2016
Resolved
DSC feature needs to be added to VHF radio.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 25 April 2016
Resolved 25 April 2016
Resolution: Operator programmed DSC into radio.
Electrical › Electric Supply System (service) › Battery Installation Ventilation
Issued 11 April 2016
Resolved
Vnetilation needs to be installed in the battery compartment.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 25 April 2016
Resolved 25 April 2016
Resolution: Operator installed natural ventilation in the battery compartment.