MAURY USCG vessel records Sign in
← All vessels

HST RESOLUTE

HST RESOLUTE is a 1988 passenger vessel (inspected). The Coast Guard has recorded 45 inspections since 1988, most recently in June 2025, along with 31 deficiencies.

Records from 1988 to 2025. Most recent: inspection, 25 June 2025.

Built
1988
Last inspected
25 June 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDG4163
311054
Flag
UNITED STATES
367533650
Maury page id
psix-311054

Inspections, by type

Years with a record 25 calendar years (1988–2025)
The 45 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)36.2 ft × 12.2 ft × 5.3 ft
Registered tonnagegross 15 / net 12
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMUNSON MANUFACTURING INC · EDMONDS, WA, UNITED STATES · built 1988
Hull materialAluminum
PropulsionDiesel Outdrive
Hull shapeShip
Hull configurationMonohull
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 28 April 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it15 - Simplified, Gross Ton
12 - Simplified, Net Ton
15 - Displacement, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDG4163MMSI 367533650 · active · compulsorily equipped · granted 29 April 2022, expires 5 June 2032
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 45

25 June 2025 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8166919
19 February 2025 Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8079638
31 October 2024 DAPI Audit · Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8035314
8 July 2024 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7946362
5 April 2023 Internal Structural Exam · COI Inspection · Administrative Inspection · DAPI Audit · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7662746
23 March 2023 Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7655587
23 March 2023 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7655669
14 June 2022 Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7476361
7 July 2021 Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7246665
17 March 2021 Drydock Extension · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7158028
17 June 2020 COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6983811
24 April 2020 Drydock Extension
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6943403
18 March 2020 Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6923181
19 June 2019 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6702949
4 April 2018 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6360303
4 April 2018 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6360323
29 March 2017 Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6109644
6 July 2016 Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5931232
7 April 2016 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5848449
11 June 2014 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 4886249
27 March 2014 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 4822701
16 May 2012 Administrative Inspection · Simplified Stability Test
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 4312050
10 January 2012 Plan Review "T" Boat · Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 4219781
25 October 2006 Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2807757
16 August 2005 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2464542
21 March 2005 Internal Structural Exam · Hull Examination
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2309652
17 May 2004 Annual Inspection · MARPOL Annex V Examination
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2061950
25 March 2003 Annual Inspection · Hull Examination · MARPOL Annex V Examination
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1760144
30 May 2001 COI Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1458884
30 March 2001 Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1386941
17 October 2000 Plan Review "T" Boat
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1418791
28 October 1996 Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1162016
26 October 1995 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1186326
8 August 1995 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 880195
28 June 1995 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1193487
15 May 1995 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 923476
29 March 1995 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 875686
13 June 1994 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1177718
23 November 1993 Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 841918
29 April 1993 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1142499
1 April 1993 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 834502
7 May 1990 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 929087
10 April 1990 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 929084
31 October 1989 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 897746
23 August 1988 Plan Review "T" Boat · Initial Certification · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1040116

Deficiency record · 31

05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 5 April 2023 Resolved
The vsls radio safety telephony FCC cert has expired. Restricted to 1000 feet from shore until inspected by a licensed FCC inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 May 2023
Resolved 10 April 2023
Resolution: Inspected.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 17 June 2020 Resolved
Weak link installed was for a 1-10 person sized life float. Vessel is outfitted with a 15 person weak link.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2020
Resolved 30 June 2020
Resolution: RCVD PO for appropriate sized weak link. RCVD Picture of weak link installed.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 17 June 2020 Resolved
Install and label paddles for the vessel's 15 person Life float.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2020
Resolved 30 June 2020
Resolution: RCVD PO for paddles. Paddles labled with the vessel's name.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 17 June 2020 Resolved
Install heat shielding/ exhaust lagging on the main diesel engines exhuast.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2020
Resolved 30 June 2020
Resolution: RCVD email. Exhaust lagging installed.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 17 June 2020 Resolved
Replace broken valve for the vessels fire main system that opens and secures the fire main station and fire hose.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2020
Resolved 30 June 2020
Resolution: Fire station gate valve replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 17 June 2020 Resolved
Repair or replace floating electric water light for the 15 person life float to conform with 46 CFR 161.010 specifications for floating electric water lights. (Water tight container with 4 retaining screws)
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2020
Resolved 30 June 2020
Resolution: Floating electric water light screw caps replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 17 June 2020 Resolved
Label 15 person life float with max persons allowed and vessel name.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2020
Resolved 30 June 2020
Resolution: Lables printed and installed on 15 person life float.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 16 August 2005 Resolved
Service B1
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 August 2005
Resolved 31 August 2005
Resolution: attestment letter
Construction/Loadline › Hull › Hull Plating
Issued 16 August 2005 Resolved
Repair crack in hull port side amidships.
Condition: Damaged By Earlier Event
Due 16 August 2005
Resolved 31 August 2005
Resolution: attestment letter
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 16 August 2005 Resolved
make line to water light between 3 and 6 feet
Condition: Improper Installation
Due 2 September 2005
Resolved 31 August 2005
Resolution: attestment letter
Construction/Loadline › Structures › Superstructure
Issued 16 August 2005 Resolved
Provide plans for approval of replacement of overhead panelling prior to begining of work.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 8 January 2016
Resolution: Requirement removed for inaction
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 17 May 2004 Resolved
Provide proof of servicing for the fixed fire extinguishing system. LEGACY COMPONENT DESC: Service
Due 17 June 2004
Resolved 9 June 2004
Documentation › Logs/Records
Issued 17 May 2004 Resolved
Provide means of establishing a shore passenger count. LEGACY COMPONENT DESC: Passenger count
Due 17 June 2004
Resolved 9 June 2004
Construction/Loadline › Hull
Issued 25 March 2003 Resolved
Repair fracture in stem of vessel.
Due 8 April 2003
Resolved 28 April 2003
Construction/Loadline › Structures
Issued 25 March 2003 Resolved
Locate and repair source of leaks in the overhead.
Due 8 April 2003
Resolved 28 April 2003
Fire Fighting › Fire Pumps
Issued 25 March 2003 Resolved
Install fire pump and hose system capable of 10 gallons per minute capacity.
Due 8 April 2003
Resolved 28 April 2003
Fire Fighting › Fire Pumps
Issued 25 March 2003 Resolved
Provide portable hand pump capable of 5 gallons per minute capacity.
Due 8 April 2003
Resolved 28 April 2003
Documentation › Certificates/Documents
Issued 25 March 2003 Resolved
Provide FCC license, certifcates & permits.
Due 8 April 2003
Resolved 28 April 2003
Lifesaving › Lifebuoys
Issued 25 March 2003 Resolved
Provide retro reflective tape for lifebouys.
Due 8 April 2003
Resolved 28 April 2003
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 25 March 2003 Resolved
Service fire extinguishers and fixed fire system.
Due 8 April 2003
Resolved 28 April 2003
Documentation › Certificates/Documents › Certificate of Inspection
Issued 25 March 2003 Resolved
Vessel missed 2002 annual exam. Owner/operator had no reason why it was missed.
Due 25 March 2003
Resolved 25 March 2003
Resolution: Vessel made avilable for inspection.
Lifesaving
Issued 30 May 2001 Resolved
POST PFD INSTRUCTION PLACARD.
Condition: Unknown
Due 8 August 2001
Resolved 8 August 2001
Navigation
Issued 30 May 2001 Resolved
PROVIDE A COMPASS CORRECTION CARD.
Condition: Unknown
Due 9 November 2001
Resolved 9 November 2001
Documentation
Issued 30 May 2001 Resolved
POST STABILITY LETTER AT OPERATING STATION.
Condition: Unknown
Due 30 November 2001
Resolved 17 May 2004
Construction/Loadline
Issued 28 June 1995 Resolved
REPAIR STBD STERN RUB RAIL WHERE FRACTURED.
Condition: Unknown
Due 28 June 1995
Resolved 28 June 1995
Unknown
Issued 29 March 1995 Resolved
PROVIDE COPIES FOR INSPECTION OF ALL DRUG TESTING RESULTS.
Condition: Unknown
Due 7 June 1995
Resolved 7 June 1995
Navigation
Issued 29 March 1995 Resolved
PROVIDE & INSTALL LENS FOR ALL AROUND WHITE NAVIGATION LIGHT.
Condition: Unknown
Due 7 June 1995
Resolved 7 June 1995
Construction/Loadline
Issued 23 August 1988 Resolved
PROVIDE ANCHOR AND/OR PROPER GROUND TACKLE AS DIRECTED BY O.C.M.I. BOSTON, MASS.
Condition: Unknown
Due 23 August 1988
Resolved 23 August 1988
Navigation
Issued 23 August 1988 Resolved
PROVIDE PROPER NAVIGATIONAL CHARTS AND PUBS FOR AREA OF ROUTE OR AS DIRECTED BY O.C.M.I. BOSTON, MASS.
Condition: Unknown
Due 23 August 1988
Resolved 23 August 1988
Navigation
Issued 23 August 1988 Resolved
PROVIDE PROPER MAG. COMPASS OR COMPASS AS DIRECTED BY O.C.M.I. BOSTON, MA.
Condition: Unknown
Due 23 August 1988
Resolved 23 August 1988
Unknown
Issued 23 August 1988 Resolved
MAKE VESSEL AVAILABLE FOR INSPECTION BY O.C.M.I. BOSTON, MASS. PRIOR TO CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 23 August 1988
Resolved 23 August 1988

Ownership record