Records from 2016 to 2025. Most recent: inspection, 14 May 2025.
Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 14 May 2025
Resolved
The equipment required for life floats must meet the following requirements:... (2) Each paddle must be of at least 4 feet in length, lashed to the life float to which it belongs and buoyant. Life float paddles are less than 4 feet in length.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2025
Resolved 15 May 2025
Resolution: Operator sent photo of new paddles installed on life float. Photo uploaded to documents.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 May 2024
Resolved
The part of the exhaust system between the point of cooling water injection and the engine manifold must be water-jacketed or effectively insulated and protected. Main engine turbocharger outlet missing insulation.
46 CFR 182.425(b)(3)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2024
Resolved 25 June 2024
Resolution: Exhaust properly insulated.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 May 2024
Resolved
A drip pan fitted with flame screen must be installed under strainers. Main engine fuel supply racor filter is missing flame shield.
46 CFR 182.455(b)(6)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2024
Resolved 25 June 2024
Resolution: Flame shield installed.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 14 May 2024
Resolved
Each life float must be fitted with a lifeline, pendants, two paddles, a painter and a light. Life float light battery inoperable.
46 CFR 180.175
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2024
Resolved 25 June 2024
Resolution: Life float battery replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 May 2024
Resolved
A vessel must be provided with bilge pumps in accordance with Table 46 CFR 182.520(a). Manual bilge pump bellows for forward bigle suction is not operational.
46 CFR 182.520(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2024
Resolved 25 June 2024
Resolution: Manual bilge pump bellows replaced.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 14 May 2024
Resolved
Provision must be made for closing all supply duct cowls for a space protected by a fixed gas extinguishing system. No means to secure supply ventilation for engine room.
46 CFR 182.465(h)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2024
Resolved 25 June 2024
Resolution: Means to secure supply ventilation made available.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 17 May 2023
Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level in a machinery space and a space with a through-hull fitting. Three bilge alarms on vessel had corroded wires, resulting in inactive alarms.
46 CFR 182.530
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 17 May 2023
Resolution: Operator replaced wiring and completed satisfactory operational test.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 May 2023
Resolved
Each life float must be fitted with a light. Life float on board has inoperable light. Install new battery for light.
46 CFR 180.175(d)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 17 May 2023
Resolution: Operator purchased and installed new light.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 May 2023
Resolved
Each ring buoy must be marked with the vessel's name. Ring buoy markings faded to be not legible. Remark buoy.
46 CFR 185.604(b)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 17 May 2023
Resolution: Operator re-marked ring buoy
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 17 May 2023
Resolved
A portable bilge pump must be capable of pumping water from all watertight compartments. Broken diaphram on built-in hand pump. Provide repair or replacement of hand pump.
46 CFR 182.520(b)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 17 May 2023
Resolved 17 May 2023
Resolution: Operator bought portable hand bilge pump
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 May 2022
Resolved
All vessels shall be provided with an approved adult type life preserver for each person carried. Missing 02 life jackets.
46 CFR 180.25-5 (old T)
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2022
Resolved 20 May 2022
Resolution: 02 missing life jackets replaced onboard.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 27 April 2021
Resolved
The Certificate of Inspection and Stability Letter must be posted under glass or other suitable transparent material, such that all pages are visible in a conspicuous place on the vessel where observation by passengers is likely.
46 CFR 176.302/46 CFR 176.306
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2021
Resolved 27 April 2021
Resolution: Operator posted COI/Stability Letter in vessel's cabin.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 27 April 2021
Resolved
The name of the vessel must be marked or painted in clearly legible letters on each life float paddle. Discovered that the paddles did not contain the vessel’s name.
46 CFR 185.604 (g)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2021
Resolved 27 April 2021
Resolution: Operator labeled the vessel's name on the life float's paddle.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 27 April 2021
Resolved
Each ring life buoy must be marked in clearly legible block capital letters with the vessel’s name. Discovered that the ring life buoy did not contain the vessel’s name.
46 CFR 185.604(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2021
Resolved 27 April 2021
Resolution: Operator clearly marked the vessel's ring life buoy with the vessel's name.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 27 April 2021
Resolved
Each lifeline fitted with a ring life buoy must be in good condition, be buoyant, and have a breaking strength of at least 1,124 pounds. Discovered that the ring life buoy’s lifeline was fraying and in poor condition.
46 CFR 180.70(c)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2021
Resolved 27 April 2021
Resolution: Operator replaced the wasted lifeline for the vessel's ring life bouy.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 11 May 2020
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. Stern Light is too short to be seen off the stern of the vessel. Vessel limited to daytime operations only and can't operate during reduced visability until deficiency is rectified. 46 CFR 183.420
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 May 2020
Resolution: Light was replaced with 24" light visible from over life float.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 May 2020
Resolved
An adult life jacket must be provided for each person carried onboard a vessel. 01 Adult Kapok life jacket found with leaking pouch and unserviceable. 46 CFR 180.71 (a)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 11 May 2020
Resolution: Adult PFD replaced with new.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 11 May 2020
Resolved
Each Life float must be fitted with two paddles. One paddle blade was cracked and unserviceable.46 CFR 180.175 (d)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 11 May 2020
Resolution: Paddle Replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 May 2020
Resolved
A vessel must carry one floating waterlight. Waterlight was missing from lifering. 46 CFR 180.70 (d)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 11 May 2020
Resolution: Waterlight provided and attached to ring buoy.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 May 2020
Resolved
Battery terminal connections shall be made to the terminals with permanent type connectors. Battery connections were made with wingnuts.46 CFR 183.05-20
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 11 May 2020
Resolution: Wingnuts were replaced with nylock nuts.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 11 May 2020
Resolved
Piping including flanges conveying vapor or gas must be suitably insulated. Turbo flange to exhaust piping is not insulated.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 May 2020
Resolution: Insulation and heat tape provided over flange.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 June 2019
Resolved
46CFR 181.30-10 - All portable fire extinguishers shall be installed and located to the satisfation of the Officer in Charge, Marine Inspection. Portable fire extinguisher located by operating station not secured to bulkhead with appropriate sized bracket. Vessel must secure adrift portable fire extinguisher to bulkhead into a device and/or bracket of the appropriate size.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 July 2019
Resolved 5 July 2019
Resolution: Vessel affixed portable fire extinguisher to bracket on bulkhead.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 12 June 2018
Resolved
An adult life jacket must be provided for each person on board. Seven Adult Life Jackets failed inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 June 2018
Resolved 13 June 2018
Resolution: Seven new life jackets provided.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 11 June 2018
Resolved
Piping including Valves, Pipe Fittings, Flanges conveying vapor or gas in which temp exceeds 150 degrees must be suitably insulated. Turbo does not have exhaust blanket on it. 46 CFR 177.970
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 July 2018
Resolved 20 August 2018
Resolution: Exhaust blankets installed onboard Engines.
Lifesaving › Lifefloat › Paddle
Issued 11 June 2018
Resolved
Life Floats must be outfitted with two paddles. One paddle was missing from life float. 46 CFR 180.175
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 July 2018
Resolved 13 June 2018
Resolution: One paddle provided.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 8 May 2017
Resolved
Life ring missing retro reflective tape.
Condition: Invalid
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 13 May 2017
Resolution: Received photo showing retro installed on lifering.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 8 May 2017
Resolved
Medkit contains expired medicines.
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 8 May 2017
Resolution: Rep replaced expired items on the spot.
Operations/Management › Drills/Instruction › Safety Orientation
Issued 8 May 2017
Resolved
Emergency instructions not onboard.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 8 May 2017
Resolution: Rep placed emergency instructions onboard.