Records from 1988 to 2022. Most recent: inspection, 24 October 2022.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 95
24 October 2022
Administrative Inspection
Administrative · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 7583160
23 September 2021
Annual Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 7319378
17 July 2020
Annual Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 7009035
3 April 2020
Drydock Exam
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6934893
7 August 2019
DAPI Audit
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6776377
8 April 2019
DAPI Audit · COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6658540
12 July 2018
Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6477176
4 April 2018
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6386253
15 June 2017
Administrative Inspection
Administrative · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6177124
30 March 2017
Annual Inspection · Internal Structural Exam · DAPI Audit
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6114865
12 July 2016
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 5937542
6 April 2016
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 5848168
8 January 2016
Administrative Inspection
Administrative · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 5799267
23 October 2014
Examination of Repairs · Damage Survey
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 5010497
22 August 2014
Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 4961920
7 July 2012
Annual Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 4370095
19 August 2011
Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 4120132
7 July 2011
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 4072256
15 September 2010
DAPI Audit
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3884445
29 April 2009
Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 3463471
15 April 2009
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 3452754
3 April 2008
Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 3177247
3 July 2007
Annual Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2937783
12 June 2007
Administrative Inspection
Administrative · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2958901
26 March 2007
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2894652
3 January 2007
Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2849220
9 August 2006
Type not recorded
No type recorded · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2757851
27 March 2006
Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2609847
20 March 2006
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2606890
10 June 2005
Type not recorded
No type recorded · USCGC GALVESTON ISLAND (WPB 1349) · USCG Oceania District (CGD-O) · Activity 2390898
3 June 2005
Drydock Extension · Annual Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2377630
30 March 2004
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2057729
24 March 2004
COI Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2030152
18 December 2002
Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1802274
22 July 2001
Administrative
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1075021
2 October 2000
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 822022
17 September 2000
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 824773
28 August 2000
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 822459
18 August 2000
MARPOL Annex V Examination · COI Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1365926
26 July 2000
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1052683
14 April 2000
Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1361363
14 March 2000
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1047403
7 March 2000
Administrative
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 815706
15 December 1999
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 812600
23 September 1999
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1032731
17 September 1999
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1122454
25 August 1999
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 780234
17 August 1999
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1361058
18 July 1999
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1098898
18 May 1999
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 132975
24 September 1998
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 800004
20 September 1998
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 799436
14 September 1998
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 799892
11 September 1998
Damage Survey
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1364851
10 September 1998
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 129878
26 August 1998
Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1364841
7 April 1998
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 789163
26 March 1998
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 688460
10 March 1998
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1120478
5 March 1998
Hull Examination · Deficiency Check · Examination of Repairs
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 784860
8 January 1998
Damage Survey
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 785157
2 January 1998
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 147952
2 January 1998
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 225061
17 November 1997
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1028514
14 October 1997
Administrative
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 776007
26 August 1997
COI Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1464703
24 March 1997
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 142594
29 January 1997
Administrative
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1104358
6 January 1997
Administrative
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1096228
12 November 1996
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1171768
3 October 1996
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 835608
29 August 1996
COI Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1249170
1 August 1996
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1089889
30 April 1996
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1081316
8 January 1996
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 874194
29 August 1995
Deficiency Check · COI Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 881253
7 February 1995
Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1148035
15 September 1994
COI Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 864974
20 September 1993
COI Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 838428
19 February 1993
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 835553
21 December 1992
Administrative
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1136330
10 November 1992
Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 954148
17 September 1992
COI Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 951149
19 May 1992
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 946226
19 May 1992
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 946227
19 May 1992
Administrative
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1259737
23 September 1991
COI Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1310353
13 December 1990
Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1237155
30 October 1990
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1238185
5 October 1990
COI Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 902400
15 March 1990
Drydock Extension
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1232281
6 October 1989
COI Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1230919
20 November 1988
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1037977
7 October 1988
Initial Certification · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1207802
7 October 1988
COI Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1209279
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 23 September 2021
Resolved
VSL on limited coastwise route must carry 6 hand red flares and 6 hand orange smokes or 12 hand red flares. Found 8 red flares on board. Provide 4 additional hand red flares.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 October 2021
Resolved 23 September 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 September 2021
Resolved
Dry exhaust pipe must be suitably insulated. Install missing exhaust lagging.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 October 2021
Resolved 23 September 2021
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 17 July 2020
Resolved
Vessel on limited coastwise route must carry (06) red flares and (06) orange smoke signals. Found (04) red flares onboard. Provide additional flares to meet the requirements.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 July 2020
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 17 July 2020
Resolved
All escape hatches must be marked in clear letter at least 2 inches high: 'EMERGENCY EXIT, KEEP CLEAR'. Mark all renewed escape hatch.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2020
Resolved 24 July 2020
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 17 July 2020
Resolved
Visual and audible bilge high level alarm must be provide at the operating station. Repair inoperable visual light for #7 & #8 voids.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2020
Resolved 24 July 2020
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 8 April 2019
Resolved
Reconnect electrical wire on deck light starboard control station.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 April 2019
Resolved 12 April 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 April 2019
Resolved
Replace all identified wasted hydraulic control levers for sail rigging system.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 April 2019
Resolved 12 April 2019
Resolution: POC ordered replacement parts off Island. VSL is authorized to operate without sail.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 April 2019
Resolved
Replace faulty engine water temperature gauge for starboard engine.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 April 2019
Resolved 12 April 2019
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 April 2019
Resolved
Replace or service identified portable CO2 fire extinguisher with under pressure.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 April 2019
Resolved 12 April 2019
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 8 April 2019
Resolved
Remove damaged electrical extension cord for entertainment equipment and install wire in conduit with wire connection in junction box.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 April 2019
Resolved 12 April 2019
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 8 April 2019
Resolved
Install missing cover on electrical outlet starboard main cabin behind seats.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 April 2019
Resolved 12 April 2019
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 12 July 2018
Resolved
Found (04) orange and (04) red flares. Vessel has LCW routs and must have (06) orange and (06) red flares. Restrict vessel route to Lakes, Bays and Sound until additional flares provided.
Due 27 July 2018
Resolved 9 April 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 12 July 2018
Resolved
Found damaged seals on (04) hatches. Repair or replace damaged gaskets.
Due 27 July 2018
Resolved 27 July 2018
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 July 2018
Resolved
Missing (01) B-II portable CO2 fire fighting extinguisher. Provide (01) CG approved type B-II CO2.
Due 27 July 2018
Resolved 27 July 2018
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 12 July 2018
Resolved
Found salt water leaking on STBD fire hydrant valve. Repair salt water leak through valve packing.
Due 27 July 2018
Resolved 27 July 2018
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 12 July 2018
Resolved
Found inoperable PA system. Show proper operation of the PA system.
Due 27 July 2018
Resolved 27 July 2018
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 12 July 2018
Resolved
Found (04) paddles life float with faded vessel name. Re-stencil vessel name on life float paddles.
Due 27 July 2018
Resolved 27 July 2018
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 12 July 2018
Resolved
Found inoperable life float light. show proper light operation.
Due 27 July 2018
Resolved 27 July 2018
Sail Rigging › Running Rigging › Sheets
Issued 4 April 2018
No resolution recorded
Static test and final rigging tune must be conducted on newly installed rigging system as required by NVIC 02-06. Vessel shall not operate under auxiliary sailing until satisfactory static test and rigging tuning are conducted.
Action required: 705 - Other - as specified
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 30 March 2017
Resolved
All life jackets must be in sericeable conditions as required by 46 CFR 176.808. Found (05) children size life jackets with torn outer covering. Replace torn children lifejackets with ones in good conditions.
Due 7 April 2017
Resolved 31 March 2017
Lifesaving › Lifefloat › Paddle
Issued 30 March 2017
Resolved
Each lifefloat must have two paddles marked with vessel mane as required by 46 CFR 180.175. Provide (01) missing paddle and re-stencil faded vessel name on paddles,
Due 7 April 2017
Resolved 5 April 2017
Stability › Weathertight Integrity › General
Issued 30 March 2017
Resolved
Found damaged glazing material used as a hatch cover on port main cabin ceiling. Replace with original glazing material.
Due 14 April 2017
Resolved 5 April 2017
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 30 March 2017
Resolved
All portable CO2 fire extinguisher must be service annual as required by NFPA 10. Provide proof of services performed on (01) BII.
Due 14 April 2017
Resolved 5 April 2017
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 30 March 2017
Resolved
Bilge suction must be fitted with suitable strainer having an open area not less than three times the area of the bilge pipe as required by 46 CFR 182.510. Install missing strainer on suction pipe for space forward of port engine room.
Due 14 April 2017
Resolved 5 April 2017
Communications › Alarms/Indicators › Fire Alarm
Issued 30 March 2017
Resolved
All smoke and fire alarms must be inspected and tested as required by 46 CFR 176.810. Repair malfunction smoke alarm in aft cabin.
Due 14 April 2017
Resolved 5 April 2017
Lifesaving › Lifefloat › Paddle
Issued 12 July 2016
Resolved
Two floatable paddles must be marked with vessel name as required by 46 CFR 185.604. Re-stencil faded vessel name on life float paddles.
Due 27 July 2016
Resolved 1 August 2016
Communications › Radio Communications › VHF Radiotelephone
Issued 12 July 2016
Resolved
VSL operating within 20NM seaward from territorial baseline must have VHF with DSC capability as required by 47 CFR 80. VSL crew are not familiar with DSC. Show proof that VHF is programmed with DSC capability.
Due 27 July 2016
Resolved 9 April 2019
Communications › Public Address System › Amplifier
Issued 12 July 2016
Resolved
VSL over 65 feet must have a fixed installed PA system as required by 46 CFR 184.610. Show proper operation of the onboard PA system.
Due 27 July 2016
Resolved 1 August 2016
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 12 July 2016
Resolved
VSL must have operating water light with 18 foot lanyard attached to light float as required by 180.175. Show proper light operations.
Due 27 July 2016
Resolved 1 August 2016
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 12 July 2016
Resolved
Generator's prime mover must have lube oil pressure gauge as required by 46 CFR 182.410. Repair inoperable lube oil pressure gauge on port generator.
Due 27 July 2016
Resolved 1 August 2016
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 12 July 2016
Resolved
Engines exhaust pipes must be that is not cooled by cooling water injection must be insulated as required by 46 CFR 182.425. Install exhaust pipes insulations.
Due 27 July 2016
Resolved 1 August 2016
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 12 July 2016
Resolved
VSL must have navigation lights as required by 46 CFR 183.420 & Nav rules. VSL bow light was removed when the mast was unstepped. Install forward light IAW Navigation rules.
Due 27 July 2016
Resolved 1 August 2016
Lifesaving › Lifefloat › Approval
Issued 8 January 2016
Resolved
Submit survival craft replacement proposal to MI for review.
Due 26 February 2016
Resolved 11 January 2016
Engineering › Diesel Engine (auxiliary) › Piston Rod
Issued 23 October 2014
Resolved
Loose piston cap causes metallic noise within engine. Repair the generator's prime mover to be attest by the attending MI.
Action required: 705 - Other - as specified
Resolved 6 January 2015
Documentation › Certificates/Documents › Stability Letter
Issued 7 July 2012
Resolved
Missing current stability letter issued by MSC as required by 46CFR176.306. Instruct VSL owner to post current stability letter at the operator station.
Due 16 July 2012
Resolved 1 August 2012
Resolution: Current stability letter issued by MSC posted.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 7 July 2012
Resolved
STBD running light's lens is poor condition 46CFR183.420. Replace running light lens.
Due 16 July 2012
Resolved 1 August 2012
Resolution: Lens replaced.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 7 July 2012
Resolved
Found expire aspirin / missing eye wash solution required in 46CFR184.710. Required VSL owner to update First aid kits.
Due 16 July 2012
Resolved 1 August 2012
Resolution: New Asprin and eye wash solution in first aid kit.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 7 July 2012
Resolved
Missing two portable lights required in 46CFR183.430. Instructed VSL owner to provide two serviceable portable lights on board.
Due 16 July 2012
Resolved 1 August 2012
Resolution: Portable lights onboard and operating.
Lifesaving › Hand Flares › Quantity
Issued 7 July 2012
Resolved
VSL has ( 4 ) red flares and ( 3 )orange flares not enough for VSL route (LCW), 46CFR180.68. Instruct VSL owner to provide (06) red and (06) orange flares.
Due 16 July 2012
Resolved 1 August 2012
Resolution: Required number and color onboard.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 7 July 2012
Resolved
Missing batteries on life jacket lights required on 46CFR180.75. Instruct VSL owner to install batteries on life jacket lights.
Due 16 July 2012
Resolved 1 August 2012
Resolution: Vessel has a limited coastwise route and does not require lights on life jackets.
Lifesaving › Lifefloat › Quantity
Issued 7 July 2012
Resolved
No life float on bard as required by 46CFR176.808. Instruct VSL owner to stow life float on board IAW 46CFR180.130.
Due 16 July 2012
Resolved 1 August 2012
Resolution: Life floats onboard as required.
Lifesaving › Lifebuoys › Serviceable
Issued 7 July 2012
Resolved
Missing retro-reflective tape (Type I) on (01) life ring required by 46CFR185.604. Instruct VSL owner to install retro-reflective tapes.
Due 16 July 2012
Resolved 1 August 2012
Resolution: Retro was replaced.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 7 July 2012
Resolved
Missing heat shields on exhaust pipes required by 46CFR182.425. Install exhaust lagging for propulsion engines and generators.
Action required: 705 - Other - as specified
Resolved 18 December 2012
Resolution: Lagging installed.
Engineering › Engine Controls (Electric/Electronic) › Circuit Board
Issued 7 July 2012
Resolved
Missing enclosure protective cover required by 46CFR183.340. Install protective cover on both propulsion control terminal panel.
Action required: 705 - Other - as specified
Resolved 18 December 2012
Resolution: Installed cover.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 7 July 2012
Resolved
Missing nonconducting mat required by 46CFR183.330. Place nonconducting mat in front of port and STBD engine room switch boards.
Due 16 July 2012
Resolved 1 August 2012
Resolution: Nonconducting mat in place as required.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 7 July 2012
Resolved
Found both engine rooms cluttered with tools, trash and engine oil containers not in compliance with 46CFR176.830. remove trash, debris, tools and other materials that might create a fire and safety hazards.
Due 16 July 2012
Resolved 1 August 2012
Resolution: Engine rooms satisfactory.
Engineering › Sea-water System (primary cooling) › Piping
Issued 7 July 2012
Resolved
STBD generator prime mover leaking salt water 46CFR182.425. Repair as original salt water leaking on STBD generator exhaust pipe.
Due 16 July 2012
Resolved 1 August 2012
Resolution: Repaired and not leaking.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 7 July 2012
Resolved
Found in-operable AC & DC indicator lights in port Nav/Light panel 46CFR183.330. Repair as original.
Due 16 July 2012
Resolved 1 August 2012
Resolution: Lights tested and operating normally. Owner replaced relay.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 7 July 2012
Resolved
Found corroded terminals and connectors on panel bus under port operator station 46CFR183.220. Repair as original and provide protection from wet and corrosive environment.
Due 16 July 2012
Resolved 1 August 2012
Resolution: Replaced and in junction box.
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 July 2012
Resolved
Found dead end wires IWO port A/C flat for missing mechanical blower 46CFR183.340. Remove dead end wire or reinstall missing blower.
Due 16 July 2012
Resolved 1 August 2012
Resolution: Removed wires.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 7 July 2012
Resolved
Dead end wire IWO port emergency SWBD 46CFR183.340. Reconnect wire for fuel tank level indicator of properly remove dead end wires.
Due 16 July 2012
Resolved 1 August 2012
Resolution: wires sealed and labeled.
Lifesaving › Hand Flares › Expired
Issued 7 July 2011
Resolved
Found three orange flares with expired dates. Provide (03) orange flares NOT outdated.
Due 14 July 2011
Resolved 22 July 2011
Fire Fighting › Means of Escape › Escape Route Signs
Issued 7 July 2011
Resolved
Mark escape hatches with 2" high letter " EMERGENCY EXIST, KEEP CLEAR".
Due 14 July 2011
Resolved 22 July 2011
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 7 July 2011
Resolved
Repair wasted return hose fittings to port sewage tank.
Due 25 July 2011
Resolved 22 July 2011
Engineering › Diesel Engine (propulsion-reduction gear) › Crankcase
Issued 7 July 2011
Resolved
Repair oil leak on starboard engine crankcase drain plug.
Due 25 July 2011
Resolved 22 July 2011
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 15 September 2010
Resolved
Pre-Employment Testing - 46 CFR 16.210/ 49 CFR 40.25
Discrepancies: Drug testing background checks completed (49 CFR part 40.25) (issued form and will implement immiediately)
Due 15 October 2010
Resolved 3 March 2011
Resolution: Corrected to the satisfaction of the attending USCG inspector.
Operations/Management › Drug and Alcohol Testing › Testing, Serious Marine Incident
Issued 15 September 2010
Resolved
Serious Marine Incident Testing - 46 CFR 16.240 or 46 CFR 4.06
Discrepancies: Arrangements made for post-casualty testing (after hours), Drug/alcohol testing devices onboard (pending new alcohol strips proof provided)
Due 15 October 2010
Resolved 3 March 2011
Resolution: Corrected to the satisfaction of the attending USCG inspector.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 15 September 2010
Resolved
EAP Requirements - 46 CFR 16.401
Discrepancies: Policy/Statement, Hotline number, Crewmembers properly trained before assuming safety sensitive position (will conduct NLT 17SEP10), Supervisor received 1 hour EAP training (by NLT 17SEP10), Employer has Substance Abuse Professional (SAP) name and contact information
Due 15 October 2010
Resolved 3 March 2011
Resolution: Corrected to the satisfaction of the attending USCG inspector.
Documentation › Manuals/Policy Documentation › Instructions for On-board Maintenance (lifesaving)
Issued 15 April 2009
Resolved
Provide inventory list to include age and recommended life span for all the components, mast, and wire rigging IAW Hono CID note #13 dated 16Oct08.
Action required: 705 - Other - as specified
Due 16 May 2009
Resolved 28 April 2010
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 April 2009
Resolved
Remove dead end wires from all electrical panels.
Action required: 705 - Other - as specified
Due 16 May 2009
Resolved 29 April 2009
Engineering › Diesel Engine (propulsion-reduction gear) › Injector (fuel injection)
Issued 15 April 2009
Resolved
Renew flexible hoses to fuel meter and injection pump on port engine.
Action required: 705 - Other - as specified
Due 16 May 2009
Resolved 29 April 2009
Engineering › Fuel Oil Service System › Filter
Issued 15 April 2009
Resolved
Install metal bowl at fuel fitler at stbd engine.
Action required: 705 - Other - as specified
Due 16 May 2009
Resolved 20 May 2009
Navigation › Collision/Grounding Avoidance › Radar
Issued 15 April 2009
Resolved
Provide operable radar. 46CFR184.404
Action required: 705 - Other - as specified
Due 16 May 2009
Resolved 29 April 2009
Resolution: Not required on existing vessel.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 3 April 2008
Resolved
Remove or secure expanded metal in port engine room.
Action required: 705 - Other - as specified
Due 23 April 2008
Resolved 23 April 2008
Communications › Alarms/Indicators › Bilge Alarm
Issued 3 April 2008
Resolved
Porve proper operation of port forward bilge alarm.
Action required: 705 - Other - as specified
Due 23 April 2008
Resolved 23 April 2008
Engineering › Fuel Oil Service System › Filter
Issued 3 April 2008
Resolved
Install fuel oil filter flame safety device.
Action required: 705 - Other - as specified
Due 23 April 2008
Resolved 23 April 2008
Operations/Management › Drills/Instruction › Not Conducted
Issued 3 July 2007
Resolved
Found operator unable to provide drill records. Prove required drills have been conducted and logged.
Action required: 705 - Other - as specified
Due 3 August 2007
Resolved 3 April 2008
Operations/Management › Drills/Instruction › Not Conducted
Issued 3 July 2007
Resolved
Found operator unable to provide a current training logbook. Prove crew has received required training.
Action required: 705 - Other - as specified
Due 3 August 2007
Resolved 3 April 2008
Operations/Management › Vessel Safety Management › Emergency Preparedness
Issued 3 July 2007
Resolved
Found main cabin space exits not properly marked. Properly mark all exits.
Action required: 705 - Other - as specified
Due 3 August 2007
Resolved 31 July 2007
Lifesaving › Lifefloat › Serviceable
Issued 3 July 2007
Resolved
Found 01 lifefloat with a damaged grabline connection. Make permanent repairs to lifefloat.
Action required: 705 - Other - as specified
Due 3 August 2007
Resolved 3 April 2008
Lifesaving › Lifebuoys › Serviceable
Issued 3 July 2007
Resolved
Found grab lines for lifebuoys dryrotted. Replace grab lines.
Action required: 705 - Other - as specified
Due 3 August 2007
Resolved 31 July 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 July 2007
Resolved
Found dead end wires from removed radar. Remove dead end wires or properly label and end in a junction box by next drydock.
Action required: 705 - Other - as specified
Due 31 October 2007
Resolved 3 April 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 July 2007
Resolved
Found dead end wires from removed GPS. Remove dead end wires or properly label and end in a junction box by next drydock.
Action required: 705 - Other - as specified
Due 31 October 2007
Resolved 3 April 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 July 2007
Resolved
Found multiple extension cords and power strips being used for audio electronics system. Properly hardwire electronics by next drydock.
Action required: 705 - Other - as specified
Due 31 October 2007
Resolved 3 April 2008
Electrical › Lighting (emergency) › Lighting Fixture
Issued 3 July 2007
Resolved
Found 01 emergency lighting fixture missing a bulb. Prove all emergency lighting is operational.
Action required: 705 - Other - as specified
Due 3 August 2007
Resolved 31 July 2007
Construction/Loadline › Hull › Weld
Issued 20 March 2006
Resolved
Found crack in stern bulwarks and cracks on 4 hand rail posts. Make permanent repairs to all cracks.
Condition: Unknown
Action required: 705 - Other - as specified
Due 13 April 2006
Resolved 27 March 2006
Construction/Loadline › Penetrations › Gasket
Issued 20 March 2006
Resolved
Found 3 through hull valves worn. Repair or replace valves.
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 April 2006
Resolved 27 March 2006
Resolution: Unity trade service inc returned to service.
Communications › Radio Communications › VHF Radiotelephone
Issued 3 June 2005
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 June 2005
Resolved 3 June 2005
Resolution: [name withheld] FCC.
Lifesaving › Hand Flares › Expired
Issued 3 June 2005
Resolved
HAND FLARES EXPIRED.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 June 2005
Resolved 3 June 2005
Resolution: COMPLETED.
Communications › Radio Communications › EPIRB
Issued 3 June 2005
Resolved
PROVIDE PROOF OF EPIRB REGISTERATION
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 June 2005
Resolved 3 June 2005
Resolution: COMPLETED.
Navigation › Collision/Grounding Avoidance › Radar
Issued 24 March 2004
Resolved
Vessel must be fitted with a FCC type accepted general marine radar system for surface navigation with a radar screen mounted at the primary operating station. The vessel is limited to carrying 49 passengers while on a Ocean Route.
Due 26 May 2004
Resolved 13 June 2005
Resolution: Removed. Vessel not granted an Oceans Route.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 24 March 2004
Resolved
20 of 156 Life Jackets/PFD's not in serviceable condition. Vessel limited to carrying 136 passengers when operating on a Limited Coastwise route. LEGACY COMPONENT DESC: Condition
Due 26 March 2004
Resolved 3 June 2005
Resolution: COMPLETED.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 24 March 2004
Resolved
Lifejackets/ PFD's missing lights. Vessel limited to Limited Coastwise Route LEGACY COMPONENT DESC: Condition
Condition: Improper Installation
Due 26 March 2004
Resolved 3 June 2005
Resolution: COMPLETED.
Lifesaving › Buoyant Apparatus › Approval
Issued 24 March 2004
Resolved
1 of 4 (22) person Lifefloats is damaged at corner. Vessel limited to carrying 66 total persons onboard while on Oceans Route. LEGACY COMPONENT DESC: Damaged/Torn
Condition: Improper/Lack of Maintenance
Due 26 March 2004
Resolved 3 June 2005
Resolution: cOMPLETED.
Documentation › Certificates/Documents
Issued 24 March 2004
Resolved
Certificate of Documentastion not onboard. Vessel may not carry more than 6 passengers. LEGACY COMPONENT DESC: Certificate of Documentation (CG-1270)
Due 26 March 2004
Resolved 30 March 2004
Resolution: Received.
Documentation › Certificates/Documents
Issued 24 March 2004
Resolved
Provide in writing designation of one qualified crew member as Senior Deckhand iaw NVIC 1-91. Vessel limited to carrying 6 passengers. LEGACY COMPONENT DESC: Senior Deckhand Designation
Due 26 March 2004
Resolved 30 March 2004
Resolution: Received.
Navigation
Issued 18 August 2000
Resolved
Repair and prove proper operation of rudder angle indicator at both operating stations
Condition: Unknown
Due 18 August 2000
Resolved 18 August 2000
Deck/Cargo
Issued 18 August 2000
Resolved
Replace frayed port main halyard.
Condition: Unknown
Due 28 August 2000
Resolved 28 August 2000
Construction/Loadline
Issued 18 August 2000
Resolved
Paint vessel name and hailing port on the stern IAW 46 CFR 67.123.
Condition: Unknown
Due 18 August 2000
Resolved 18 August 2000
Electrical
Issued 18 August 2000
Resolved
Trace and correct electrical ground on the air handling unit.
Condition: Unknown
Due 28 August 2000
Resolved 28 August 2000
Engineering
Issued 18 August 2000
Resolved
Repair inoperative lube oil pressure gauges at operating stations.
Condition: Unknown
Due 18 August 2000
Resolved 18 August 2000
Lifesaving
Issued 18 August 2000
Resolved
Conduct training for man overboard and fire emergencies, specifically crowdcontrol, communications, and fire fighting procedures. Crew to perform satisfactory drills in the presence of a CG Inspector.
Condition: Unknown
Due 28 August 2000
Resolved 28 August 2000
Documentation
Issued 18 August 2000
Resolved
Schedule and conduct a Drug and Alcohol Testing Program audit.
Condition: Unknown
Due 24 August 2000
Resolved 24 August 2000
Lifesaving
Issued 17 August 1999
Resolved
PROVIDE BRIGHTLY COLORED WATERTIGHT BOX MARKED DISTRESS SIGNALS.
Condition: Unknown
Due 17 August 1999
Resolved 17 August 1999
Construction/Loadline
Issued 17 August 1999
Resolved
PROVE PROPER OPERATION OF THE PORT AND STBD BILGE PUMPS TAKING SUCTION FROMEVERY COMPARTMENT INCLUDING PORT AND STBD CROSS CONNECTS.
Condition: Unknown
Due 17 August 1999
Resolved 17 August 1999
Electrical
Issued 17 August 1999
Resolved
REPAIR S/W LEAK ON #1 S/S GENERATOR MUFFLER.
Condition: Unknown
Due 17 August 1999
Resolved 17 August 1999
Accommodation/Occupational Safety
Issued 17 August 1999
Resolved
REPAIR LEAKING PVC LINE ABOVE THE #1 MDE.
Condition: Unknown
Due 17 August 1999
Resolved 17 August 1999
Electrical
Issued 17 August 1999
Resolved
INSTALL MISSING COVERS ON LIGHTS IN STBD HEAD AND PORT HEAD.
Condition: Unknown
Due 17 August 1999
Resolved 17 August 1999
Electrical
Issued 17 August 1999
Resolved
INSTALL EXHAUST LAGGING OR ADEQUATE SHIELDING ON NO. 1 AND NO. 2 S/S GENERATOR EXHAUST MANIFOLDS.
Condition: Unknown
Due 17 August 1999
Resolved 17 August 1999
Electrical
Issued 17 August 1999
Resolved
RECONNECT LOOSE GROUND WIRE ON AFT LIGHT RECEPTACLE, STBD HEAD.
Condition: Unknown
Due 17 August 1999
Resolved 17 August 1999
Navigation
Issued 17 August 1999
Resolved
SHIELD FOR PORT AND STBD RUNNING LIGHTS TO BE PAINTED BLACK MATTE.
Condition: Unknown
Due 17 August 1999
Resolved 17 August 1999
Electrical
Issued 17 August 1999
Resolved
PROVIDE PORTABLE LIGHT AT OPERATING STATION AND EACH ENGINE ROOM ENTRANCE.
Condition: Unknown
Due 17 August 1999
Resolved 17 August 1999
Navigation
Issued 17 August 1999
Resolved
PROVE PROPER OPERATION OF VESSEL'S ANCHOR LIGHT.
Condition: Unknown
Due 17 August 1999
Resolved 17 August 1999
Lifesaving
Issued 17 August 1999
Resolved
PROVIDE SUITABLE PAINTERS AND WEAKLINKS FOR VESSEL'S LIFEFLOATS.
Condition: Unknown
Due 17 August 1999
Resolved 17 August 1999
Lifesaving
Issued 17 August 1999
Resolved
PROVIDE PADDLES FOR TWO OF THE VESSEL'S LIFEFLOATS IAW 46 CFR 180.137.
Condition: Unknown
Due 17 August 1999
Resolved 17 August 1999
Lifesaving
Issued 17 August 1999
Resolved
PROVIDE CG APPROVED /OR EQUIVALENT FIRST AID KIT.
Condition: Unknown
Due 17 August 1999
Resolved 17 August 1999
Navigation
Issued 17 August 1999
Resolved
PROVIDE APPLICABLE SECTIONS OF COAST PILOT.
Condition: Unknown
Due 17 August 1999
Resolved 17 August 1999
Fire Fighting
Issued 17 August 1999
Resolved
PROPERLY SECURE FIRE EXTINGUISHER, WHICH IS LOCATED AT THE OPERATING STATION.
Condition: Unknown
Due 17 August 1999
Resolved 17 August 1999
Lifesaving
Issued 17 August 1999
Resolved
REMOVE LIFELINE FROM ONE OF THE VESSEL'S RINGBUOYS.
Condition: Unknown
Due 17 August 1999
Resolved 17 August 1999
Lifesaving
Issued 17 August 1999
Resolved
PROVIDE SUITABLE TYPE I REFLECTIVE TAPE FOR 53 IDENTIFIED LIFEJACKETS.
Condition: Unknown
Due 17 August 1999
Resolved 17 August 1999
Unknown
Issued 17 August 1999
Resolved
PROVIDE PROOF OF SUBSTANTIAL COMPLIANCE OF VESSEL'S DRUG AND ALCOHOL POLICY.
Condition: Unknown
Due 17 August 1999
Resolved 17 August 1999
Engineering
Issued 17 August 1999
Resolved
INSTALL FLAME SCREEN 30 X 30 MESH WIRE, STBD FUEL TANK.
Condition: Unknown
Due 17 August 1999
Resolved 17 August 1999
Construction/Loadline
Issued 17 August 1999
Resolved
PROPERLY LABEL LOADING MARKS/DRAFT MARKS ON PORT AND STBD HULLS,_x001C_ FORWARD AND AFT.
Condition: Unknown
Due 17 August 1999
Resolved 17 August 1999
Construction/Loadline
Issued 17 August 1999
Resolved
Demonstrate proper operation of all sea valves.
Condition: Unknown
Due 17 August 1999
Resolved 17 August 1999
Lifesaving
Issued 17 August 1999
Resolved
PROVIDE A STATION BILL IAW 46 CFR 185.514.
Condition: Unknown
Due 17 August 1999
Resolved 17 August 1999
Engineering
Issued 17 August 1999
Resolved
PROPERLY INSULATE EXHAUST PIPING, NO. 2 MDE.
Condition: Unknown
Due 17 August 1999
Resolved 17 August 1999
Construction/Loadline
Issued 17 August 1999
Resolved
Double clamp all raw water piping for both MDE's and generators.
Condition: Unknown
Due 17 August 1999
Resolved 17 August 1999
Documentation
Issued 17 August 1999
Resolved
MASTER SHALL DESIGNATE THE SENIOR DECKHAND IN WRITING AND A COPY OF THIS DESIGNATION SHALL BE RETAINED ONBOARD THE VESSEL. THE SENIOR DECKHAND SHALLBE PROPERLY TRAINED IAW NVIC 1-91.
Condition: Unknown
Due 17 August 1999
Resolved 17 August 1999
Electrical
Issued 17 August 1999
Resolved
Install cover for thermostat and light dimmer switch in aft, stbd section of dining room.
Condition: Unknown
Due 17 August 1999
Resolved 17 August 1999
Unknown
Issued 17 August 1999
Resolved
REPLACE CONTROL HANDLE PORT AND STBD HYDRAULIC WINCHES.
Condition: Unknown
Due 17 August 1999
Resolved 17 August 1999
Construction/Loadline
Issued 17 August 1999
Resolved
CLEAN PORT AFT BILGE STRAINER.
Condition: Unknown
Due 17 August 1999
Resolved 17 August 1999
Electrical
Issued 17 August 1999
Resolved
REMOVE OR PROPERLY SECURE DEAD-END WIRE IN NAVIGATIONAL LIGHT PANEL.
Condition: Unknown
Due 17 August 1999
Resolved 17 August 1999
Electrical
Issued 17 August 1999
Resolved
REPAIR/INSTALL CONTROL KNOB FOR N.U.C. LIGHT.
Condition: Unknown
Due 17 August 1999
Resolved 17 August 1999
Engineering
Issued 17 August 1999
Resolved
REMOVE/PLUG SMALL VENT, PORT/STBD F.O. FILLING STATIONS.
Condition: Unknown
Due 17 August 1999
Resolved 17 August 1999
Navigation
Issued 17 August 1999
Resolved
PROVIDE ILLUMINATION FOR VESSEL'S MAGNETIC COMPASS.
Condition: Unknown
Due 17 August 1999
Resolved 17 August 1999
Lifesaving
Issued 17 August 1999
Resolved
PROVIDE 3 - 6 FEET LANYARDS W/ CRES CLIP FOR VESSEL'S WATERLIGHT.
Condition: Unknown
Due 17 August 1999
Resolved 17 August 1999
Navigation
Issued 17 August 1999
Resolved
PROVIDE VHF-FM RADIO AT THE PRIMARY PORT OPERATING STATION.
Condition: Unknown
Due 17 August 1999
Resolved 17 August 1999
Construction/Loadline
Issued 17 August 1999
Resolved
Provide portable hand bilge pump with adequate suction and discharge hoses to dewater any compartment.
Condition: Unknown
Due 17 August 1999
Resolved 17 August 1999
Electrical
Issued 17 August 1999
Resolved
Install emergency disconnect switch for port and stbd MDE and generator starting batteries.
Condition: Unknown
Due 17 August 1999
Resolved 17 August 1999
Electrical
Issued 17 August 1999
Resolved
Properly block / brace all starting batteries within both enginerooms.
Condition: Unknown
Due 17 August 1999
Resolved 17 August 1999
Engineering
Issued 17 August 1999
Resolved
Remove absorbent pads, port fuel filling station.
Condition: Unknown
Due 17 August 1999
Resolved 17 August 1999
Engineering
Issued 17 August 1999
Resolved
Prove operation of No. 1 MDE shutdown from helm.
Condition: Unknown
Due 17 August 1999
Resolved 17 August 1999
Engineering
Issued 17 August 1999
Resolved
Repair S/W leaks on #2 MDE intercooler and reduction gear cooler hoses/piping.
Condition: Unknown
Due 17 August 1999
Resolved 17 August 1999
Fire Fighting
Issued 17 August 1999
Resolved
Properly secure fire extinguishers in both port and stbd enginerooms.
Condition: Unknown
Due 17 August 1999
Resolved 17 August 1999
Construction/Loadline
Issued 17 August 1999
Resolved
RE-INSTALL CENTER OUTBOARD DOG ON STBD ENGINEROOM WTD.
Condition: Unknown
Due 17 August 1999
Resolved 17 August 1999
Construction/Loadline
Issued 17 August 1999
Resolved
PROVE PROPER OPERATION OF REMOTE VISUAL INDICATORS AT THE OPERATING STATIONFOR PORT AND STBD WTD'S.
Condition: Unknown
Due 17 August 1999
Resolved 17 August 1999
Construction/Loadline
Issued 17 August 1999
Resolved
CHALK TEST AND LABEL DIRECTION OF OPEN/CLOSE PORT AND STBD WTD'S.
Condition: Unknown
Due 17 August 1999
Resolved 17 August 1999
Construction/Loadline
Issued 17 August 1999
Resolved
MASTER MUST ENSURE PORT AND STBD WTD'S AT FRAME F11F ARE DOGGED SHUT_x001C_ AND LOGGED PRIOR TO GETTING U/W FOR EACH VOYAGE.
Condition: Unknown
Due 17 August 1999
Resolved 17 August 1999
Electrical
Issued 17 August 1999
Resolved
REPAIR AND DEMONSTRATE EMERGENCY BATTERY SELECTOR SWITCH, EMERGENCY DC POWER PANEL.
Condition: Unknown
Due 17 August 1999
Resolved 17 August 1999
Construction/Loadline
Issued 17 August 1999
Resolved
Renew deteriorated weathertight door, aft stbd lounge.
Condition: Unknown
Due 17 August 1999
Resolved 17 August 1999
Construction/Loadline
Issued 17 August 1999
Resolved
Replaced chafed L/O hoses at L/O filters for No. 1 MDE.
Condition: Unknown
Due 17 August 1999
Resolved 17 August 1999
Engineering
Issued 17 August 1999
Resolved
REPAIR FUEL LEAK ON FUEL INJECTOR LINES FOR THE NO. 1 S/S GENERATOR.
Condition: Unknown
Due 17 August 1999
Resolved 17 August 1999
Fire Fighting
Issued 17 August 1999
Resolved
PROVE PROPER OPERATION OF THE FIXED FIRE PUMP AT 60 PSI AND 50 GPM.
Condition: Unknown
Due 17 August 1999
Resolved 17 August 1999
Electrical
Issued 17 August 1999
Resolved
_x001C_ PROPERLY DEAD-END WIRING IN A JUNCTION BOX FOR THE STBD URINAL PUMP FLUSH SWITCH._x001C_
Condition: Unknown
Due 17 August 1999
Resolved 17 August 1999
Construction/Loadline
Issued 17 August 1999
Resolved
REPLACE DEFECTIVE BILGE SUCTION VALVE FOR COMPARTMENT FWD OF STBD COLLISIONBULKHEAD.
Condition: Unknown
Due 17 August 1999
Resolved 17 August 1999
Unknown
Issued 17 August 1999
Resolved
CLAMP AHU DRAINAGE LINE, PORT ENGINEROOM.
Condition: Unknown
Due 17 August 1999
Resolved 17 August 1999
Engineering
Issued 17 August 1999
Resolved
PROVE OPERATION OF THE PORT AND STBD MDES' AND GENERATORS' REMOTE FUEL SHUTDOWN VALVES.
Condition: Unknown
Due 17 August 1999
Resolved 17 August 1999
Construction/Loadline
Issued 17 August 1999
Resolved
MAKE PORT AND STBD HEAD DECK HATCHES WATERTIGHT.
Condition: Unknown
Due 17 August 1999
Resolved 17 August 1999
Construction/Loadline
Issued 17 August 1999
Resolved
INSTALL HANDLE ON EMERGENCY ESCAPE, PORT ENGINEROOM.
Condition: Unknown
Due 17 August 1999
Resolved 17 August 1999
Unknown
Issued 17 August 1999
Resolved
SECURE MSD BLADDER IN PORT HEAD.
Condition: Unknown
Due 17 August 1999
Resolved 17 August 1999
Engineering
Issued 17 August 1999
Resolved
CLEAN EXCESS OIL FROM EXHAUST VENT DUCT, STBD ENGINEROOM.
Condition: Unknown
Due 17 August 1999
Resolved 17 August 1999
Construction/Loadline
Issued 17 August 1999
Resolved
RE-WELD FRACTURED LONGITUDINAL FRAME ABOVE STBD RUDDERPOST.
Condition: Unknown
Due 17 August 1999
Resolved 17 August 1999
Construction/Loadline
Issued 17 August 1999
Resolved
MAKE MAIN DECK INSPECTION COVERS FOR STEERING GEAR WATERTIGHT.
Condition: Unknown
Due 17 August 1999
Resolved 17 August 1999
Construction/Loadline
Issued 17 August 1999
Resolved
INSTALL AUDIBLE AND VISUAL HIGH-LEVEL BILGE ALARMS AT THE OPERATING STATIONIAW 46 CFR 182.530 FOR ALL EIGHT WATERTIGHT COMPARTMENTS.
Condition: Unknown
Due 17 August 1999
Resolved 17 August 1999
Electrical
Issued 17 August 1999
Resolved
REMOVE WIRE NUTS AND INSTALL UL APPROVED PRESSURE CONNECTORS AND PLACE SPLICE IN A JUNCTION BOX FOR THE STBD URINAL PUMP.
Condition: Unknown
Due 17 August 1999
Resolved 17 August 1999
Lifesaving
Issued 18 July 1999
Resolved
Prove the satisfactory operation and installation of the vessel's EPIRB. Until such time, the vessel's route is restricted to not more than 3 miles from shore.
Condition: Unknown
Due 18 July 1999
Resolved 18 July 1999
Construction/Loadline
Issued 11 September 1998
Resolved
Install an insulating collar between the brass bilge suction piping and thebasket strainer on all bilge suction lines to prevent accelerated oxidationof the aluminum strainer and hull.
Condition: Unknown
Due 11 September 1998
Resolved 11 September 1998
Construction/Loadline
Issued 11 September 1998
Resolved
Thoroughly clean the bilge in #2 void. Remove all oxidation residue to provide a better assessment of the hull thickness. Visual apperance show signs of accelerated corrosion.
Condition: Unknown
Due 11 September 1998
Resolved 11 September 1998
Documentation
Issued 26 August 1998
Resolved
OBTAIN FCC OPERATOR'S PERMIT FOR ALL LICENSED MASTERS
Condition: Unknown
Due 26 August 1998
Resolved 26 August 1998
Fire Fighting
Issued 26 August 1998
Resolved
HYDROSTATIC TEST ALL PORTABLE FIRE EXTINGUISHERS
Condition: Unknown
Due 26 August 1998
Resolved 26 August 1998
Construction/Loadline
Issued 26 August 1998
Resolved
PROPERLY SECURE HATCH IWO PORT ENGINE ROOM AND MAIN DECK
Condition: Unknown
Due 26 August 1998
Resolved 26 August 1998
Lifesaving
Issued 26 August 1998
Resolved
STENCIL AND REPLACE REFLECTIVE TAPE ON LIFEJACKETS AS NEEDED
Condition: Unknown
Due 26 August 1998
Resolved 26 August 1998
Accommodation/Occupational Safety
Issued 26 August 1998
Resolved
CROP AND RENEW GALLEY DECK (APPROX 2' X 3') IWO OF LADDER.
Condition: Unknown
Due 26 August 1998
Resolved 26 August 1998
Construction/Loadline
Issued 8 January 1998
Resolved
Effect permanent repairs to damage on stbd hull. Vessel is restricted to operations within Apra Harbor only. Temporary repairs to be upgraded as per instructions given, damaged void to be inspected every two hours when passengers onboard. Owners to keep MSO appraised of drydock arrangements.
Condition: Unknown
Due 8 January 1998
Resolved 8 January 1998
Unknown
Issued 8 January 1998
Resolved
Post copy of CG-835 issued 08 January 1998 with vessel Certificate of Inspection.
Condition: Unknown
Due 8 January 1998
Resolved 8 January 1998
Unknown
Issued 17 November 1997
Resolved
Prove 50% drug testing by random method.
Condition: Unknown
Due 17 November 1997
Resolved 17 November 1997
Lifesaving
Issued 17 November 1997
Resolved
Repair grab lines on all buoyant apparatus.
Condition: Unknown
Due 17 November 1997
Resolved 17 November 1997
Unknown
Issued 26 August 1997
Resolved
Bring the DOT/CG mandated Drug Testing Program up to standards of 46 CFR, Part 16.
Condition: Unknown
Due 26 August 1997
Resolved 26 August 1997
Construction/Loadline
Issued 26 August 1997
Resolved
Post bilge valve and piping diagram, along with operating instructions, in area of bilge manifolds, each engineroom.
Condition: Unknown
Due 26 August 1997
Resolved 26 August 1997
Documentation
Issued 26 August 1997
Resolved
Obtain FCC required inspection of radio, along with FCC Communications Act Safety Radiotelephony Certificate.
Condition: Unknown
Due 26 August 1997
Resolved 26 August 1997
Construction/Loadline
Issued 26 August 1997
Resolved
Obtain proper handles for the 3-way bilge manifold valves.
Condition: Unknown
Due 26 August 1997
Resolved 26 August 1997
Accommodation/Occupational Safety
Issued 26 August 1997
Resolved
Initiate a Waste Management Plan in accordance with 33 CFR 151.57.
Condition: Unknown
Due 26 August 1997
Resolved 26 August 1997
Lifesaving
Issued 26 August 1997
Resolved
Make necessary repairs to the nine (9) person Bouyant Apparatus to ensure continued servicability.
Condition: Unknown
Due 26 August 1997
Resolved 26 August 1997
Construction/Loadline
Issued 26 August 1997
Resolved
Prove operation of the engineroom watertight door remote indicator lights at bridge control station.
Condition: Unknown
Due 26 August 1997
Resolved 26 August 1997
Electrical
Issued 26 August 1997
Resolved
Install cover plate over open electrical junction box, starboard A/C room.
Condition: Unknown
Due 26 August 1997
Resolved 26 August 1997
Lifesaving
Issued 29 August 1996
Resolved
Replace all expired smoke and flare pyrotechnic devices.
Condition: Unknown
Due 29 August 1996
Resolved 29 August 1996
Lifesaving
Issued 29 August 1996
Resolved
Mark location and number of child sized life jackets.
Condition: Unknown
Due 29 August 1996
Resolved 29 August 1996
Engineering
Issued 29 August 1996
Resolved
Install port engineroom vent supply blower.
Condition: Unknown
Due 29 August 1996
Resolved 29 August 1996
Electrical
Issued 29 August 1996
Resolved
Identify flex cord passing through port engineroom.
Condition: Unknown
Due 29 August 1996
Resolved 29 August 1996
Electrical
Issued 29 August 1996
Resolved
Repair emergency lighting above stairways port and starboard side.
Condition: Unknown
Due 29 August 1996
Resolved 29 August 1996
Accommodation/Occupational Safety
Issued 29 August 1996
Resolved
Repair broken toilet in female head.
Condition: Unknown
Due 29 August 1996
Resolved 29 August 1996
Unknown
Issued 29 August 1995
Resolved
ESTABLISH VESSEL DRUG TESTING PROGRAM FOR CG REVIEW.
Condition: Unknown
Due 29 August 1995
Resolved 29 August 1995
Documentation
Issued 29 August 1995
Resolved
PRESENT COPY OF STABILITY LETTER TO CG INSPECTOR, POST COPY UNDER GLASS OR SUITABLE MATERIAL.
Condition: Unknown
Due 29 August 1995
Resolved 29 August 1995
Construction/Loadline
Issued 29 August 1995
Resolved
INSTALL MISSING BOLTS IN WAY HATCH COVER, FWD BULKHEAD, PORT HULL, IN WAY OF A/C FLAT.
Condition: Unknown
Due 29 August 1995
Resolved 29 August 1995
Lifesaving
Issued 29 August 1995
Resolved
RESTENCIL VESSEL NAME AND CAPACITY ON ALL BOUYANT APPARATUS.
Condition: Unknown
Due 29 August 1995
Resolved 29 August 1995
Lifesaving
Issued 29 August 1995
Resolved
REPAIR OR REPLACE BROKEN HOLDING BRACKET FOR PORTABLE FIRE EXTINGUISHER LOCATED UPPER DECK, PORT SIDE.
Condition: Unknown
Due 29 August 1995
Resolved 29 August 1995
Lifesaving
Issued 29 August 1995
Resolved
REPLACE MISSING RING BOUY.
Condition: Unknown
Due 29 August 1995
Resolved 29 August 1995
Engineering
Issued 29 August 1995
Resolved
REPAIR SEA WATER LEAK ON PORT GENERATOR SILENCER.
Condition: Unknown
Due 29 August 1995
Resolved 29 August 1995
Engineering
Issued 29 August 1995
Resolved
TROUBLE SHOOT ENGINE INSTRUMENT PANEL LOCATED BRIDGE PORT CONTROL STATION.
Condition: Unknown
Due 29 August 1995
Resolved 29 August 1995
Engineering
Issued 29 August 1995
Resolved
REMOVE EXISTING RUBBER HOSE FROM P&S FUEL TANK CAP, BLANK OFF OPENING.
Condition: Unknown
Due 29 August 1995
Resolved 29 August 1995
Accommodation/Occupational Safety
Issued 29 August 1995
Resolved
CLEAN OVEN/STOVE UNIT.
Condition: Unknown
Due 29 August 1995
Resolved 29 August 1995
Documentation
Issued 29 August 1995
Resolved
INSTALL OIL POLLUTION PLACARDS IN ENGINEERING SPACES.
Condition: Unknown
Due 29 August 1995
Resolved 29 August 1995
Documentation
Issued 29 August 1995
Resolved
PRESENT VESSEL ORIGINAL DOCUMENTATION CERTIFICATE.
Condition: Unknown
Due 29 August 1995
Resolved 29 August 1995
Engineering
Issued 29 August 1995
Resolved
DETERMINE WHETHER FUEL TANKS ARE INDEPENDANT OR INTEGRAL WITH HULL, CONTACTCG MARINE INSPECTOR WITH INFO.
Condition: Unknown
Due 30 August 1995
Resolved 30 August 1995
Accommodation/Occupational Safety
Issued 29 August 1995
Resolved
PROVIDE [name withheld] SOLUTION TO ADDRESS VESSEL TYPE I MSD SYSTEM.
Condition: Unknown
Due 29 August 1995
Resolved 29 August 1995
Engineering
Issued 20 September 1993
Resolved
INSTALL INDEPENDENT VENT LINES ON EACH FUEL TANK WITH A MINIMUM NOMINAL SIZE OF 5/8", VENTED TO THE OUTSIDE OF THE HULL, WITH A 30/30 MESH STAINLESS STEEL FLAME SCREEN.
Condition: Unknown
Due 20 September 1993
Resolved 20 September 1993
Documentation
Issued 5 October 1990
Resolved
PROVIDE A VALID FCC STATION LIC. AND FCC SAFETY CERTIFICATE.
Condition: Unknown
Due 5 October 1990
Resolved 5 October 1990
Documentation
Issued 5 October 1990
Resolved
PROVIDE A VALID DOCUMENT FOR THE VESSEL.
Condition: Unknown
Due 5 October 1990
Resolved 5 October 1990
Fire Fighting
Issued 5 October 1990
Resolved
RELOCATE THE FIRE AXE TO COMPLY WITH 46 CFR 181.35-1.
Condition: Unknown
Due 5 October 1990
Resolved 5 October 1990
Electrical
Issued 5 October 1990
Resolved
PROPERLY SUPPORT THE CABLE RUN IN THE PORT ENGINE ROOM OUTBOURD BULKHEAD.
Condition: Unknown
Due 5 October 1990
Resolved 5 October 1990
Lifesaving
Issued 5 October 1990
Resolved
PROVIDE PENDANTS FO9R THE 5 BUOYANT APARATUS AS REQUIRED BY 46 CFR 160.010-3
Condition: Unknown
Due 5 October 1990
Resolved 5 October 1990
Documentation
Issued 7 October 1988
Resolved
ADVISE [name withheld] ARRIVAL IN ZONE AND INTENTIONS TO COMMENCE PASSENGER OPERATIONS.
Condition: Unknown
Due 7 October 1988
Resolved 7 October 1988
Navigation
Issued 7 October 1988
Resolved
CONDUCT A SAILING TRIAL TO THE SATISFACTION OF [name withheld].
Condition: Unknown
Due 7 October 1988
Resolved 7 October 1988
Documentation
Issued 7 October 1988
Resolved
POST THE FOLLOWING CERTIFICATES AND PLACARDS ONBOARD: 1) CERTIFICATE OF INSPECTION; 2) STABILITY LETTER; 3) POLLUTION PLACARD; 4) EMERGENCY CHECK-OFF LIST; 5) FCC LICENSE.
Condition: Unknown
Due 7 October 1988
Resolved 7 October 1988
Lifesaving
Issued 7 October 1988
Resolved
PROVIDE SIX HAND HELD USCG APPROVED SMOKE SIGNALS.
Condition: Unknown
Due 7 October 1988
Resolved 7 October 1988
Fire Fighting
Issued 7 October 1988
Resolved
PROVIDE A PORTABLE FIRE PUMP MEETING 46 CFR 181.10. ITEMS 1 THROUGH 5 SHALL BE COMPLETED TO THE SATISFACTION OF [name withheld] PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 7 October 1988
Resolved 7 October 1988