A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 23 September 2021
Resolved
VSL on limited coastwise route must carry 6 hand red flares and 6 hand orange smokes or 12 hand red flares. Found 8 red flares on board. Provide 4 additional hand red flares.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 October 2021
Resolved 23 September 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 September 2021
Resolved
Dry exhaust pipe must be suitably insulated. Install missing exhaust lagging.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 October 2021
Resolved 23 September 2021
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 17 July 2020
Resolved
Vessel on limited coastwise route must carry (06) red flares and (06) orange smoke signals. Found (04) red flares onboard. Provide additional flares to meet the requirements.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 July 2020
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 17 July 2020
Resolved
All escape hatches must be marked in clear letter at least 2 inches high: 'EMERGENCY EXIT, KEEP CLEAR'. Mark all renewed escape hatch.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2020
Resolved 24 July 2020
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 17 July 2020
Resolved
Visual and audible bilge high level alarm must be provide at the operating station. Repair inoperable visual light for #7 & #8 voids.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2020
Resolved 24 July 2020
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 8 April 2019
Resolved
Reconnect electrical wire on deck light starboard control station.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 April 2019
Resolved 12 April 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 April 2019
Resolved
Replace all identified wasted hydraulic control levers for sail rigging system.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 April 2019
Resolved 12 April 2019
Resolution: POC ordered replacement parts off Island. VSL is authorized to operate without sail.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 April 2019
Resolved
Replace faulty engine water temperature gauge for starboard engine.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 April 2019
Resolved 12 April 2019
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 April 2019
Resolved
Replace or service identified portable CO2 fire extinguisher with under pressure.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 April 2019
Resolved 12 April 2019
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 8 April 2019
Resolved
Remove damaged electrical extension cord for entertainment equipment and install wire in conduit with wire connection in junction box.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 April 2019
Resolved 12 April 2019
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 8 April 2019
Resolved
Install missing cover on electrical outlet starboard main cabin behind seats.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 April 2019
Resolved 12 April 2019
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 12 July 2018
Resolved
Found (04) orange and (04) red flares. Vessel has LCW routs and must have (06) orange and (06) red flares. Restrict vessel route to Lakes, Bays and Sound until additional flares provided.
Due 27 July 2018
Resolved 9 April 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 12 July 2018
Resolved
Found damaged seals on (04) hatches. Repair or replace damaged gaskets.
Due 27 July 2018
Resolved 27 July 2018
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 July 2018
Resolved
Missing (01) B-II portable CO2 fire fighting extinguisher. Provide (01) CG approved type B-II CO2.
Due 27 July 2018
Resolved 27 July 2018
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 12 July 2018
Resolved
Found salt water leaking on STBD fire hydrant valve. Repair salt water leak through valve packing.
Due 27 July 2018
Resolved 27 July 2018
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 12 July 2018
Resolved
Found inoperable PA system. Show proper operation of the PA system.
Due 27 July 2018
Resolved 27 July 2018
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 12 July 2018
Resolved
Found (04) paddles life float with faded vessel name. Re-stencil vessel name on life float paddles.
Due 27 July 2018
Resolved 27 July 2018
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 12 July 2018
Resolved
Found inoperable life float light. show proper light operation.
Due 27 July 2018
Resolved 27 July 2018
Sail Rigging › Running Rigging › Sheets
Issued 4 April 2018
No resolution recorded
Static test and final rigging tune must be conducted on newly installed rigging system as required by NVIC 02-06. Vessel shall not operate under auxiliary sailing until satisfactory static test and rigging tuning are conducted.
Action required: 705 - Other - as specified
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 30 March 2017
Resolved
All life jackets must be in sericeable conditions as required by 46 CFR 176.808. Found (05) children size life jackets with torn outer covering. Replace torn children lifejackets with ones in good conditions.
Due 7 April 2017
Resolved 31 March 2017
Lifesaving › Lifefloat › Paddle
Issued 30 March 2017
Resolved
Each lifefloat must have two paddles marked with vessel mane as required by 46 CFR 180.175. Provide (01) missing paddle and re-stencil faded vessel name on paddles,
Due 7 April 2017
Resolved 5 April 2017
Stability › Weathertight Integrity › General
Issued 30 March 2017
Resolved
Found damaged glazing material used as a hatch cover on port main cabin ceiling. Replace with original glazing material.
Due 14 April 2017
Resolved 5 April 2017
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 30 March 2017
Resolved
All portable CO2 fire extinguisher must be service annual as required by NFPA 10. Provide proof of services performed on (01) BII.
Due 14 April 2017
Resolved 5 April 2017
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 30 March 2017
Resolved
Bilge suction must be fitted with suitable strainer having an open area not less than three times the area of the bilge pipe as required by 46 CFR 182.510. Install missing strainer on suction pipe for space forward of port engine room.
Due 14 April 2017
Resolved 5 April 2017
Communications › Alarms/Indicators › Fire Alarm
Issued 30 March 2017
Resolved
All smoke and fire alarms must be inspected and tested as required by 46 CFR 176.810. Repair malfunction smoke alarm in aft cabin.
Due 14 April 2017
Resolved 5 April 2017
Lifesaving › Lifefloat › Paddle
Issued 12 July 2016
Resolved
Two floatable paddles must be marked with vessel name as required by 46 CFR 185.604. Re-stencil faded vessel name on life float paddles.
Due 27 July 2016
Resolved 1 August 2016
Communications › Radio Communications › VHF Radiotelephone
Issued 12 July 2016
Resolved
VSL operating within 20NM seaward from territorial baseline must have VHF with DSC capability as required by 47 CFR 80. VSL crew are not familiar with DSC. Show proof that VHF is programmed with DSC capability.
Due 27 July 2016
Resolved 9 April 2019
Communications › Public Address System › Amplifier
Issued 12 July 2016
Resolved
VSL over 65 feet must have a fixed installed PA system as required by 46 CFR 184.610. Show proper operation of the onboard PA system.
Due 27 July 2016
Resolved 1 August 2016
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 12 July 2016
Resolved
VSL must have operating water light with 18 foot lanyard attached to light float as required by 180.175. Show proper light operations.
Due 27 July 2016
Resolved 1 August 2016
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 12 July 2016
Resolved
Generator's prime mover must have lube oil pressure gauge as required by 46 CFR 182.410. Repair inoperable lube oil pressure gauge on port generator.
Due 27 July 2016
Resolved 1 August 2016
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 12 July 2016
Resolved
Engines exhaust pipes must be that is not cooled by cooling water injection must be insulated as required by 46 CFR 182.425. Install exhaust pipes insulations.
Due 27 July 2016
Resolved 1 August 2016
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 12 July 2016
Resolved
VSL must have navigation lights as required by 46 CFR 183.420 & Nav rules. VSL bow light was removed when the mast was unstepped. Install forward light IAW Navigation rules.
Due 27 July 2016
Resolved 1 August 2016
Lifesaving › Lifefloat › Approval
Issued 8 January 2016
Resolved
Submit survival craft replacement proposal to MI for review.
Due 26 February 2016
Resolved 11 January 2016