MAURY USCG vessel records Sign in
← All vessels

SUPER LADY

SUPER LADY is a 2000 tank ship. The Coast Guard has recorded 28 inspections since 2001, most recently in February 2011, along with 3 deficiencies and 11 operational controls, 2 with no removal date recorded.

Records from 2001 to 2011. Most recent: inspection, 11 February 2011.

Built
2000
Last inspected
11 February 2011
Documentation
Not in the documentation file of 10 September 2026
Controls
2 with no removal date recorded

Identity

9201592 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
MALTA
—
Maury page id
psix-31169

Inspections, by type

…with no type recorded21
Years with a record 9 calendar years (2001–2011)
The 28 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 15 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it32082 - Convention (Subpart B), Net Ton
56204 - Convention (Subpart B), Gross Ton
121982 - Displacement, Ton
105528 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 28

11 February 2011 Ballast Water Examination · COC-TVE Renew · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3943878
25 July 2009 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3545241
25 July 2009 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3547282
13 April 2009 ISPS II Exam · Ballast Water Examination · COC-TVE Renew
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3451960
31 October 2007 PII Safety Exam · ISPS III Exam · Ballast Water Examination · COC-TVE Annual
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 3089845
31 October 2007 Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 3090426
26 October 2007 Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 3093148
24 March 2007 Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2894102
9 August 2006 PII Safety Exam · COC-TVE Renew · Ballast Water Examination · ISPS III Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2741388
7 July 2006 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2704883
2 July 2006 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2706555
1 July 2006 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2700537
19 June 2006 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2684737
14 June 2006 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2679869
10 February 2005 Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 2289942
12 September 2004 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2193467
11 September 2004 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2193164
6 August 2004 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 2158154
19 June 2004 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2120921
26 March 2004 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2040078
15 March 2004 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 2059871
8 October 2003 Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1923848
23 September 2003 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1910954
9 July 2003 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1840495
8 August 2002 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1658544
12 July 2002 Certificate of Compliance
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1646324
25 March 2002 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1601021
9 July 2001 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 291549

Deficiency record · 3

Engineering › Diesel Engine (auxiliary) › Piston Ring
Issued 10 February 2005 Resolved
On February 4, 2005, this office received notification that the M/V Young Lady required repairs to the main engine, specifically, the renewal of the #6 cylinder and overhaul of all main engine cylinders. The main engine was discovered to be losing pressure. When looking at #6 piston, it was discovered that it only had two rings, both severly wasted. The cause of the rings being wasted is unknown.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 February 2005
Resolution: Received class letter attesting to satisfactory repair of main engine.
Pollution Prevention/Response › Prevention Equipment
Issued 9 July 2003 Resolved
a connection flange was found on the OWS OVBD discharge line. DEF. was issued to make the connection permanently non removable, prior to departure LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Condition: Improper Installation
Due 6 October 2003
Resolved 6 October 2003
Resolution: Flange was welded closed.
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 9 July 2003 Resolved
found emergency gear locker on deck being used to store an extra 200 gallons of paint. Vessel to remove all paint from the locker and stow in the paint locker,prior to departure.
Condition: Improper Installation
Due 9 July 2003
Resolved 9 July 2003
Resolution: confirmed all paint was properly stowed.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.