Records from 2016 to 2026. Most recent: inspection, 18 March 2026.
Inspection history · 29
18 March 2026
Type not recorded
No type recorded · USCGC COBIA (WPB 87311) · USCG Heartland District (CGD-H) · Activity 8329035
16 December 2025
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8284093
18 June 2025
Examination of Repairs · Damage Survey · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8162595
12 November 2024
Annual Inspection · Special Consideration · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8033699
16 August 2024
Type not recorded
No type recorded · USCGC DANIEL TARR (WPC-1136) · USCG Heartland District (CGD-H) · Activity 8009709
28 March 2024
Exemption · Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7886343
13 February 2024
Drydock Exam · Administrative Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7864933
1 February 2024
Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7858992
8 November 2023
Annual Inspection · Administrative Inspection · Deficiency Check · Special
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7821607
31 October 2022
COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7587265
27 October 2022
Type not recorded
No type recorded · USCGC RIDLEY (WPB 87328) · USCG Southeast District (CGD-SE) · Activity 7585187
11 July 2022
In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7503623
31 May 2022
Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7463857
2 February 2022
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7390800
25 October 2021
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7339258
23 July 2021
In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7264332
26 October 2020
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7084336
5 February 2020
Internal Structural Exam · Deficiency Check · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6903938
30 October 2019
DAPI Audit · In-Service Inspection · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6847043
16 October 2019
Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6835868
25 March 2019
DAPI Audit · Administrative Inspection · COI Inspection · In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6646618
31 July 2018
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6498238
19 July 2018
COI Inspection · Administrative Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6484191
16 February 2018
Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6356476
26 September 2017
DAPI Audit · Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6275690
8 December 2016
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6055459
2 September 2016
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5990350
14 April 2016
Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5854459
18 February 2016
Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5817824
09 - Working and Living Conditions › 091 - Living Conditions › Furnishings
Issued 18 June 2025
Resolved
Remove all damaged paneling and electrical installations in way of the closet and adjacent compartment to expose fiberglass hull structures and to determine extent and cause of electrical damage. Attendance by a Coast Guard Marine Inspector to complete above examination must be done prior to vessel movement.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 July 2025
Resolution: Attended vessel and verified satisfactory repairs.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 13 February 2024
Resolved
Replace both port and starboard main diesel engine raw water suction valves by end of this DD period.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 16 February 2024
Resolution: Corrected.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 8 November 2023
Resolved
The fixed gas extinguishing system must be capable of securing all engines that draw air from in the protected space. The PORT generator does not secure upon activation of the fire system.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 November 2023
Resolution: Corrected.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 8 November 2023
Resolved
The vessel must have a VHF-DSC radio that is properly installed. The radio must be GPS capable or linked to a GPS.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2023
Resolved 16 February 2024
Resolution: Corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 30 October 2019
Resolved
Provide and install a proper weak link for life floats.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 November 2019
Resolved 5 February 2020
Resolution: Lifefloat weak link properly installed.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 30 October 2019
Resolved
Install proper fuel tank vent lines and meshing
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 November 2019
Resolved 5 February 2020
Resolution: Vent lines and meshing renewed.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 30 October 2019
Resolved
Ensure engine room ventilation dampers properly seal.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 November 2019
Resolved 5 February 2020
Resolution: Vent dampeners seated properly
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 October 2019
Resolved
Remove installed extension cord cabeling and replace with marine cable.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 November 2019
Resolved 5 February 2020
Resolution: Extension cords removed.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 30 October 2019
Resolved
Repair emergency lighting in accommodation space
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 November 2019
Resolved 5 February 2020
Resolution: Emergency lighting properly installed.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 30 October 2019
Resolved
Repair lighting in accommodation space
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 November 2019
Resolved 5 February 2020
Resolution: Lighting properly installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 October 2019
Resolved
Properly label life ring
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 November 2019
Resolved 5 February 2020
Resolution: Vessel name labeled on life ring.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 30 October 2019
Resolved
Properly secure bow hand rails prior to next dry dock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 5 February 2020
Resolution: Handrails properly secured.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 30 October 2019
Resolved
Install cover on A/C unit
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 November 2019
Resolved 5 February 2020
Resolution: A/C cover installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 October 2019
Resolved
Label breakers and repair power panel.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 November 2019
Resolved 5 February 2020
Resolution: Panel repaired and breakers properly labeled.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 October 2019
Resolved
Vessel was not made available to conduct in-service inspection. Vessel is prohibited from carrying passengers overnight until vessel completes in-service inspection to the satisfaction of the attending Coast Guard Marine Inspector.
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 October 2019
Resolved 30 October 2019
Resolution: completed in-service inspection
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 31 July 2018
Resolved
NLT 29OCT18 Vessel shall provide a special consideration request to allow PVC piping in bilge system or remove all rigid non-metallic piping in the bilge system.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 October 2018
Resolved 2 May 2019
Resolution: Received approved and signed copy from Sector Mobile for PVC Bilge piping special consideration.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 19 July 2018
Resolved
Repair three holes in aft engineroom bulkhead to ensure bulkhead is vapor tight. Citation: 46 CFR 182.35-1
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 August 2018
Resolved 10 August 2018
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 10 October 2017
Resolved
Forward deck railing is loose, tighten deck railing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 November 2017
Resolved 15 November 2017
Resolution: Correctly tightened
Lifesaving › Lifefloat › Serviceable
Issued 10 October 2017
Resolved
Repair tears in vinyl coating on life floats.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 November 2017
Resolved 15 November 2017
Resolution: Repaired as needed
Lifesaving › Lifefloat › Retroreflective Material
Issued 10 October 2017
Resolved
Replace worn retro-reflective material with Type II retro-reflective material meeting
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 November 2017
Resolved 15 November 2017
Resolution: Replaced with correct material
Communications › Public Address System › Loudspeaker
Issued 10 October 2017
Resolved
Public address system was not able to be heard in the accommodation space, repair the system so it is audible throughout the accommodation spaces of the vessel during normal operating conditions.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 November 2017
Resolved 15 November 2017
Resolution: Corrected and tested
Stability › Watertight Integrity › General
Issued 10 October 2017
Resolved
Watertight hatch on aft deck is not properly sealing hatch, replace seal.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 November 2017
Resolved 15 November 2017
Resolution: Replaced seal
Engineering › Bilge Water Management System › Piping
Issued 10 October 2017
Resolved
Replace PVC bilge piping with a suitable piping material.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 March 2018
Resolved 31 July 2018
Resolution: Cleared deficiency and subsequently reissued IAW SECMOB guidance regarding PVC Piping in Bilge Systems
Fire Fighting › Means of Escape › Doorways
Issued 2 September 2016
Resolved
Replace hing on emergency escape hatch.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 November 2016
Resolved 8 October 2016
Resolution: Hinge on emergency escape hatch was replaced.
Engineering › Pressure Vessel › Support
Issued 2 September 2016
Resolved
Mount/Secure head tank bottle, for potable water, in FWD engine room.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 November 2016
Resolved 8 December 2016
Resolution: Head tank bottle, for potable water, in FWD engine room was mounted/secured.
Lifesaving › Lifefloat › Paddle
Issued 2 September 2016
Resolved
Label paddle on life float.
Action required: 705 - Other - as specified
Due 30 November 2016
Resolved 8 December 2016
Resolution: Life float paddle was properly marked.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 2 September 2016
Resolved
Add a copy of the emergency instructions to pilot house.
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 November 2016
Resolved 8 December 2016
Resolution: A copy of the emergency instructions were posted in the pilot house.