LADY S is a 1989 passenger vessel (inspected). The Coast Guard has recorded 65 inspections since 1989, most recently in March 2026, along with 78 deficiencies and 1 operational control.

Records from 1989 to 2026. Most recent: inspection, 18 March 2026.

Built
1989
Last inspected
18 March 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDK7514
311794
Flag
UNITED STATES
368085110
Maury page id
psix-311794

Inspections, by type

…with no type recorded6
Years with a record 35 calendar years (1989–2026)
The 65 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)64.1 ft × 19.0 ft × 8.0 ft
Registered tonnagegross 65 / net 52
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBONNER YACHT · WETURNPHA, AL, UNITED STATES · built 1989
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portPANAMA CITY, FL
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 6 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it65 - Simplified, Gross Ton
52 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

EX305MMSI 368085110 · active · exemption · granted 1 April 2024, expires 22 March 2028
WDK7514MMSI 368085110 · active · compulsorily equipped · granted 3 April 2019, expires 3 April 2029
WDI4175MMSI 367695940 · cancelled · compulsorily equipped · granted 8 October 2015, cancelled 19 March 2019 · licensed under a name not among this hull’s recorded names (not shown)
WDC4810MMSI 367030960 · expired · compulsorily equipped · granted 6 April 2005, cancelled 6 June 2015 · licensed under a name not among this hull’s recorded names (not shown)
WAG7797MMSI not assigned · expired · compulsorily equipped · granted 31 October 1994, cancelled 18 December 2004 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 65

18 March 2026 Type not recorded
No type recorded · USCGC COBIA (WPB 87311) · USCG Heartland District (CGD-H) · Activity 8329035
16 December 2025 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8284093
18 June 2025 Examination of Repairs · Damage Survey · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8162595
12 November 2024 Annual Inspection · Special Consideration · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8033699
16 August 2024 Type not recorded
No type recorded · USCGC DANIEL TARR (WPC-1136) · USCG Heartland District (CGD-H) · Activity 8009709
28 March 2024 Exemption · Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7886343
13 February 2024 Drydock Exam · Administrative Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7864933
1 February 2024 Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7858992
8 November 2023 Annual Inspection · Administrative Inspection · Deficiency Check · Special
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7821607
31 October 2022 COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7587265
27 October 2022 Type not recorded
No type recorded · USCGC RIDLEY (WPB 87328) · USCG Southeast District (CGD-SE) · Activity 7585187
11 July 2022 In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7503623
31 May 2022 Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7463857
2 February 2022 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7390800
25 October 2021 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7339258
23 July 2021 In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7264332
26 October 2020 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7084336
5 February 2020 Internal Structural Exam · Deficiency Check · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6903938
30 October 2019 DAPI Audit · In-Service Inspection · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6847043
16 October 2019 Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6835868
25 March 2019 DAPI Audit · Administrative Inspection · COI Inspection · In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6646618
31 July 2018 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6498238
19 July 2018 COI Inspection · Administrative Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6484191
16 February 2018 Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6356476
26 September 2017 DAPI Audit · Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6275690
8 December 2016 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6055459
2 September 2016 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5990350
14 April 2016 Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5854459
18 February 2016 Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5817824
17 September 2015 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5721978
17 September 2015 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5724363
19 August 2015 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5206611
14 August 2014 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4948302
5 March 2014 Hull Examination · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4793477
12 July 2012 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4376856
8 July 2011 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4074046
15 March 2010 Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3696210
22 April 2008 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3190034
20 March 2008 Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3168256
31 May 2007 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2948025
23 March 2006 Internal Structural Exam · Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2609120
14 April 2005 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2373071
18 March 2004 Hull Examination · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2026636
20 May 2003 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1797401
16 May 2002 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1619696
11 April 2002 Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1604235
6 June 2001 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 212378
5 June 2001 Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1472068
3 June 2001 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 184986
17 April 2001 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1467279
23 February 2000 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1413655
6 October 1998 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1408183
16 December 1997 Type not recorded
No type recorded · USCG Heartland District (dp) · USCG Heartland District (CGD-H) · Activity 726129
22 October 1997 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1409769
20 December 1996 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1357883
26 October 1995 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1374434
2 November 1994 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1363136
9 November 1993 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1422300
27 October 1992 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1429698
6 October 1992 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1379708
19 December 1991 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1262452
2 May 1991 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1236438
1 April 1991 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1223731
20 December 1990 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 909343
23 October 1989 Initial Certification · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1199147

Deficiency record · 78

09 - Working and Living Conditions › 091 - Living Conditions › Furnishings
Issued 18 June 2025 Resolved
Remove all damaged paneling and electrical installations in way of the closet and adjacent compartment to expose fiberglass hull structures and to determine extent and cause of electrical damage. Attendance by a Coast Guard Marine Inspector to complete above examination must be done prior to vessel movement.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 July 2025
Resolution: Attended vessel and verified satisfactory repairs.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 13 February 2024 Resolved
Replace both port and starboard main diesel engine raw water suction valves by end of this DD period.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 16 February 2024
Resolution: Corrected.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 8 November 2023 Resolved
The fixed gas extinguishing system must be capable of securing all engines that draw air from in the protected space. The PORT generator does not secure upon activation of the fire system.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 November 2023
Resolution: Corrected.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 8 November 2023 Resolved
The vessel must have a VHF-DSC radio that is properly installed. The radio must be GPS capable or linked to a GPS.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2023
Resolved 16 February 2024
Resolution: Corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 30 October 2019 Resolved
Provide and install a proper weak link for life floats.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 November 2019
Resolved 5 February 2020
Resolution: Lifefloat weak link properly installed.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 30 October 2019 Resolved
Install proper fuel tank vent lines and meshing
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 November 2019
Resolved 5 February 2020
Resolution: Vent lines and meshing renewed.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 30 October 2019 Resolved
Ensure engine room ventilation dampers properly seal.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 November 2019
Resolved 5 February 2020
Resolution: Vent dampeners seated properly
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 October 2019 Resolved
Remove installed extension cord cabeling and replace with marine cable.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 November 2019
Resolved 5 February 2020
Resolution: Extension cords removed.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 30 October 2019 Resolved
Repair emergency lighting in accommodation space
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 November 2019
Resolved 5 February 2020
Resolution: Emergency lighting properly installed.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 30 October 2019 Resolved
Repair lighting in accommodation space
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 November 2019
Resolved 5 February 2020
Resolution: Lighting properly installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 October 2019 Resolved
Properly label life ring
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 November 2019
Resolved 5 February 2020
Resolution: Vessel name labeled on life ring.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 30 October 2019 Resolved
Properly secure bow hand rails prior to next dry dock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 5 February 2020
Resolution: Handrails properly secured.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 30 October 2019 Resolved
Install cover on A/C unit
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 November 2019
Resolved 5 February 2020
Resolution: A/C cover installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 October 2019 Resolved
Label breakers and repair power panel.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 November 2019
Resolved 5 February 2020
Resolution: Panel repaired and breakers properly labeled.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 October 2019 Resolved
Vessel was not made available to conduct in-service inspection. Vessel is prohibited from carrying passengers overnight until vessel completes in-service inspection to the satisfaction of the attending Coast Guard Marine Inspector.
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 October 2019
Resolved 30 October 2019
Resolution: completed in-service inspection
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 31 July 2018 Resolved
NLT 29OCT18 Vessel shall provide a special consideration request to allow PVC piping in bilge system or remove all rigid non-metallic piping in the bilge system.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 October 2018
Resolved 2 May 2019
Resolution: Received approved and signed copy from Sector Mobile for PVC Bilge piping special consideration.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 19 July 2018 Resolved
Repair three holes in aft engineroom bulkhead to ensure bulkhead is vapor tight. Citation: 46 CFR 182.35-1
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 August 2018
Resolved 10 August 2018
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 10 October 2017 Resolved
Forward deck railing is loose, tighten deck railing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 November 2017
Resolved 15 November 2017
Resolution: Correctly tightened
Lifesaving › Lifefloat › Serviceable
Issued 10 October 2017 Resolved
Repair tears in vinyl coating on life floats.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 November 2017
Resolved 15 November 2017
Resolution: Repaired as needed
Lifesaving › Lifefloat › Retroreflective Material
Issued 10 October 2017 Resolved
Replace worn retro-reflective material with Type II retro-reflective material meeting
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 November 2017
Resolved 15 November 2017
Resolution: Replaced with correct material
Communications › Public Address System › Loudspeaker
Issued 10 October 2017 Resolved
Public address system was not able to be heard in the accommodation space, repair the system so it is audible throughout the accommodation spaces of the vessel during normal operating conditions.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 November 2017
Resolved 15 November 2017
Resolution: Corrected and tested
Stability › Watertight Integrity › General
Issued 10 October 2017 Resolved
Watertight hatch on aft deck is not properly sealing hatch, replace seal.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 November 2017
Resolved 15 November 2017
Resolution: Replaced seal
Engineering › Bilge Water Management System › Piping
Issued 10 October 2017 Resolved
Replace PVC bilge piping with a suitable piping material.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 March 2018
Resolved 31 July 2018
Resolution: Cleared deficiency and subsequently reissued IAW SECMOB guidance regarding PVC Piping in Bilge Systems
Fire Fighting › Means of Escape › Doorways
Issued 2 September 2016 Resolved
Replace hing on emergency escape hatch.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 November 2016
Resolved 8 October 2016
Resolution: Hinge on emergency escape hatch was replaced.
Engineering › Pressure Vessel › Support
Issued 2 September 2016 Resolved
Mount/Secure head tank bottle, for potable water, in FWD engine room.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 November 2016
Resolved 8 December 2016
Resolution: Head tank bottle, for potable water, in FWD engine room was mounted/secured.
Lifesaving › Lifefloat › Paddle
Issued 2 September 2016 Resolved
Label paddle on life float.
Action required: 705 - Other - as specified
Due 30 November 2016
Resolved 8 December 2016
Resolution: Life float paddle was properly marked.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 2 September 2016 Resolved
Add a copy of the emergency instructions to pilot house.
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 November 2016
Resolved 8 December 2016
Resolution: A copy of the emergency instructions were posted in the pilot house.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 19 August 2015 Resolved
Obtain new FCC Radio Station license and new FCC Safety Certificate (those onboard were expired). IAW 47 CFR 80.13 & 47 CFR 80.903.
Action required: 705 - Other - as specified
Due 30 September 2015
Resolved 7 October 2015
Resolution: Issue resolved to the satisfaction of the marine inspector.
Engineering › Pressure Vessel › Relief Valve
Issued 19 August 2015 Resolved
Change relief valve on hot water tank. Relief must not be more than 100 PSI. (Relief valve currently installed was rated at 150 PSI). IAW 46 CFR 182.320.
Action required: 705 - Other - as specified
Due 2 September 2015
Resolved 17 September 2015
Resolution: Verified installation of proper pressure relief valve on hot water heater (75 psi).
Navigation › Piloting/Steering › Marine Charts
Issued 19 August 2015 Resolved
Update navigational charts and publications. IAW 46 CFR 184.420.
Action required: 705 - Other - as specified
Due 2 September 2015
Resolved 17 September 2015
Resolution: Verified vessel had current navigational charts and publications.
Engineering › Fuel Oil Service System › Piping
Issued 19 August 2015 Resolved
Ensure all piping for bilge systems and fuel systems are secured with clamps, brackets, etc. IAW 46 CFR 182.700.
Action required: 705 - Other - as specified
Due 2 September 2015
Resolved 17 September 2015
Resolution: Verified all bilge and fuel system piping properly secured.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 19 August 2015 Resolved
Provide fire-fighting equipment servicing report (for annual service). IAW 46 CFR 176.810
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 August 2015
Resolution: Provided documents of fire fighting system service.
Electrical › Electrical Distribution System (service) › Cable
Issued 14 August 2014 Resolved
Fuel tank fitting grounding straps were corroded, repair IAW 46CFR182.440 (b) (4) .
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 September 2014
Resolved 11 September 2014
Resolution: Repaired grounding strap to fuel tank fittings.
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 14 August 2014 Resolved
Air tank and water pump not mounted properly, repair IAW 46cfr176.380
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 September 2014
Resolved 11 September 2014
Resolution: Air tank and water pump properly mounted to base in engine room.
Fire Fighting › Means of Escape › Handrails/Handholds
Issued 14 August 2014 Resolved
Hand rails along main deck were loose, repair IAW 46CFR179.900
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 September 2014
Resolved 11 September 2014
Resolution: Hand rails along main deck were tightened.
Navigation › Piloting/Steering › Marine Charts
Issued 14 August 2014 Resolved
Paper charts were not on board, needs to be provided IAW 46CFR184.420
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 September 2014
Resolved 11 September 2014
Resolution: Paper charts were provided.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 14 August 2014 Resolved
Vapor tightness missing where emergency vent cover cable runs through bulkhead. Repair IAW 46cfr176.610
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 September 2014
Resolved 11 September 2014
Resolution: Vapor tightness was applied to bulkhead where cable ran thru.
Documentation › Certificates/Documents › Stability Letter
Issued 14 August 2014 Resolved
Stability letter missing the signature page.
Action required: 705 - Other - as specified
Due 14 September 2014
Resolved 26 September 2014
Resolution: Issued new stability letter
Electrical › Lighting (emergency) › Lighting Fixture
Issued 11 July 2011 Resolved
Vessels 12 volt emergency lighting system was not operating.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 July 2011
Resolved 12 July 2011
Resolution: Vessel rep corrected the problem with the 12 volt emergency lighting system.
Lifesaving › Lifebuoys › Approval
Issued 22 April 2008 Resolved
Lifebuoy's approval # not visible. Replace lifebuoy.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 May 2008
Resolved 13 April 2010
Electrical › Lighting (service) › Lighting Fixture
Issued 22 April 2008 Resolved
Put cage on light cover, port side engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 May 2008
Resolved 13 April 2010
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 22 April 2008 Resolved
Name of vessel on float light and EPIRB.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 May 2008
Resolved 13 April 2010
Engineering › Feedwater/Condensate Water System › Piping
Issued 22 April 2008 Resolved
Add second hose clap to water intake hose.
Action required: 705 - Other - as specified
Due 22 May 2008
Resolved 13 April 2010
Construction/Loadline › Penetrations › Flange Pad
Issued 31 May 2007 Resolved
The bolt/nut connection on the rudder post that connected the ram to the rudder had worked its way loose.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 May 2007
Stability › Watertight Integrity › General
Issued 14 April 2005 Resolved
Correctly fill all open watertight bulkhead penetrations.
Condition: Improper Installation
Due 14 May 2005
Resolved 1 May 2005
Engineering › Diesel Engine (propulsion-reduction gear) › Silencer (exhaust)
Issued 14 April 2005 Resolved
Repair cracks in port and starboard main engine exhaust systems.
Due 14 May 2005
Resolved 1 May 2005
Electrical › Lighting (service) › Lighting Fixture
Issued 14 April 2005 Resolved
Replace globes on port side engine room lighting fixtures.
Condition: Improper Installation
Due 14 May 2005
Resolved 1 May 2005
Engineering › Fuel Oil Service System › Filter
Issued 14 April 2005 Resolved
Repair weeping leak on port fuel filter assembly.
Condition: Improper/Lack of Maintenance
Due 14 May 2005
Resolved 1 May 2005
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 April 2005 Resolved
Hard wire potable water pump in proper junction box vice molded plug currently being used.
Condition: Improper Installation
Due 14 May 2005
Resolved 1 May 2005
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 April 2005 Resolved
Ensure all recently installed receptacles comply with currently subchapter T regulations as discussed.
Condition: Improper Installation
Due 14 May 2005
Resolved 1 May 2005
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 14 April 2005 Resolved
Renew all fuel vent flame screens.
Condition: Improper/Lack of Maintenance
Due 14 May 2005
Resolved 1 May 2005
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 14 April 2005 Resolved
Label all electrical controllers/circuit breakers/switches as to their service.
Condition: Improper Installation
Due 14 May 2005
Resolved 1 May 2005
Engineering › Sea-water System (primary cooling) › Valve
Issued 14 April 2005 Resolved
Label all seawater valves as to their service.
Condition: Improper Installation
Due 14 May 2005
Resolved 1 May 2005
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 14 April 2005 Resolved
Install machinery guards for port and starboard main engine alternator pulleys.
Condition: Improper Installation
Due 14 May 2005
Resolved 1 May 2005
Communications › Alarms/Indicators › Bilge Alarm
Issued 20 May 2003 Resolved
Label bilge alarms at Operating Station.
Action required: 705 - Other - as specified
Due 20 June 2003
Resolved 22 May 2003
Navigation › Piloting/Steering › Coast Guard Light List
Issued 20 May 2003 Resolved
Provide updated Coast Guard light list.
Action required: 17 - Rectify deficiencies prior to departure
Due 20 June 2003
Resolved 22 May 2003
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 20 May 2003 Resolved
Provide updated tide/current tables.
Action required: 17 - Rectify deficiencies prior to departure
Due 20 June 2003
Resolved 22 May 2003
Communications › Audible Communications › Bell
Issued 20 May 2003 Resolved
Provide bell.
Action required: 17 - Rectify deficiencies prior to departure
Due 20 June 2003
Resolved 22 May 2003
Lifesaving › Buoyant Apparatus
Issued 20 May 2003 Resolved
Provide weak link for lifefloats. LEGACY COMPONENT DESC: Weak Link
Action required: 17 - Rectify deficiencies prior to departure
Due 20 June 2003
Resolved 22 May 2003
Lifesaving › Hand Flares › Storage
Issued 20 May 2003 Resolved
Properly label distress signal container.
Action required: 705 - Other - as specified
Due 20 June 2003
Resolved 22 May 2003
Engineering › Fuel Oil Service System › Filter
Issued 20 May 2003 Resolved
Provide metal plugs for center main engine fuel filter.
Action required: 705 - Other - as specified
Due 20 June 2003
Resolved 22 May 2003
Documentation › Certificates/Documents
Issued 20 May 2003 Resolved
Provide proof of radio operator's permit. LEGACY COMPONENT DESC: License, Radio Operator
Action required: 705 - Other - as specified
Due 20 June 2003
Resolved 22 May 2003
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 20 May 2003 Resolved
Renew expired items in first aid kit.
Action required: 705 - Other - as specified
Due 20 June 2003
Resolved 22 May 2003
Documentation › Markings/Placards
Issued 16 May 2002 Resolved
Provide an Emergency Broadcast Placard. LEGACY COMPONENT DESC: Emergency Broadcast Placard
Action required: 705 - Other - as specified
Due 16 June 2002
Resolved 22 May 2003
Navigation › Piloting/Steering
Issued 16 May 2002 Resolved
Provide Coast Guard Light List. LEGACY COMPONENT DESC: Coast Guard Light List
Action required: 705 - Other - as specified
Due 16 June 2002
Resolved 15 May 2003
Navigation › Piloting/Steering
Issued 16 May 2002 Resolved
Provide Inland Navigation Rules. LEGACY COMPONENT DESC: Inland Navigation Rules
Action required: 705 - Other - as specified
Due 16 June 2002
Resolved 21 September 2015
Navigation › Piloting/Steering
Issued 16 May 2002 Resolved
Provide Tide/Tidal Current Tables. LEGACY COMPONENT DESC: Tide/Tidal Current Tables
Action required: 705 - Other - as specified
Due 16 June 2002
Resolved 22 May 2003
Lifesaving › Lifebuoys
Issued 16 May 2002 Resolved
Attach 60 ft. of lifeline and replace reflective tape. LEGACY COMPONENT DESC: Buoyant Lifeline
Action required: 705 - Other - as specified
Due 16 June 2002
Resolved 22 May 2003
Lifesaving › Rigid Liferafts
Issued 16 May 2002 Resolved
Attach two lifefloats together with a painter. LEGACY COMPONENT DESC: Painter
Action required: 17 - Rectify deficiencies prior to departure
Due 16 June 2002
Resolved 22 May 2003
Communications › Radio Communications
Issued 16 May 2002 Resolved
Change the location of the EPIRB, move it out from under overhang. LEGACY COMPONENT DESC: EPIRB
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 May 2003
Communications › Visual Communication
Issued 16 May 2002 Resolved
Provide appropriate day shapes. LEGACY COMPONENT DESC: Day Shapes
Action required: 705 - Other - as specified
Due 16 June 2002
Resolved 22 May 2003
Communications › Alarms/Indicators
Issued 16 May 2002 Resolved
Label bilge alarms, provide location beside indicator. LEGACY COMPONENT DESC: Bilge Alarm
Action required: 705 - Other - as specified
Due 16 June 2002
Resolved 22 May 2003
Documentation › Logs/Records
Issued 16 May 2002 Resolved
Log crew training, drills and EPIRB checks in vessel log book. LEGACY COMPONENT DESC: Logbook (official)
Action required: 705 - Other - as specified
Due 16 June 2002
Resolved 22 May 2003
Unknown
Issued 5 June 2001 Resolved
COMPLETE REPAIRS TO VESSEL AS A RESULT OF AN ENGINE ROOM FIRE TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 26 June 2001
Resolved 29 June 2001
Documentation
Issued 20 December 1990 Resolved
PROVIDE RECIEPT OF RADIO SAFETY CERTIFICATE.
Condition: Unknown
Action required: 705 - Other - as specified
Due 21 September 2015
Resolved 21 September 2015
Electrical
Issued 23 October 1989 Resolved
PROVIDE DATA FOR GENERATORS AND MOTORS AS REQUIRED BY 46 CFR 183.10-5
Condition: Unknown
Action required: 705 - Other - as specified
Due 21 September 2015
Resolved 21 September 2015
Construction/Loadline
Issued 23 October 1989 Resolved
PROVIDE DETAILS OF THROUGH HULL FITTING INSTALLATIONS
Condition: Unknown
Action required: 705 - Other - as specified
Due 21 September 2015
Resolved 21 September 2015
Engineering
Issued 23 October 1989 Resolved
PROVIDE MATERIAL LIST FOR PIPING SYSTEMS AND THROUGH HULL FITTINGS.
Condition: Unknown
Action required: 705 - Other - as specified
Due 21 September 2015
Resolved 21 September 2015

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.