MAURY USCG vessel records
← All vessels

O-SEA-D

Built
1988
Last inspected
14 July 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 14 July 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WCZ7738
312394
Flag
UNITED STATES
Maury page id
psix-312394

Documentation record

Registered dimensions (L × B × D)40.2 ft × 14.0 ft × 7.3 ft
Registered tonnagegross 27 / net 22
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderC W B ENTERPRISES INC · MEDLEY, FL, UNITED STATES · built 1988
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portPOMPANO BEACH, FL
Endorsements, as the file codes themcw_un, rec
DocumentationValid · issued 15 July 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it27 - Simplified, Gross Ton
22 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 17 inspections, each with its date, unit and type; 27 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 17

14 July 2026 Deficiency Check · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8436916
15 July 2025 Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8186640
9 July 2025 Annual Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8180850
3 October 2024 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8013201
1 August 2023 COI Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7757819
11 July 2023 Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7740430
27 February 2023 Administrative Inspection · Construction Oversight
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7671569
2 November 2022 Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7587889
14 September 2021 Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7311892
3 August 2021 Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7275854
19 October 2020 Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7079609
13 November 2019 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6854892
7 August 2019 Drydock Exam · In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6775783
10 August 2018 DAPI Audit · Deficiency Check · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6506218
8 August 2018 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6504626
1 August 2017 DAPI Audit · Annual Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6234234
2 November 2016 Annual Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6033691

Deficiency record · 27

03 - Water/Weathertight Conditions › N/A - No Subsystem › Bulwarks and freeing ports
Issued 14 July 2026 Resolved
The intent of this part is to insure that the scantlings, material, fastenings, workmanship and arrangement of each vessel are such as to provide for safe operation in accordance with the terms of its certificate of inspection. MI’s observed deterioration on the railing post, located three posts starboard aft at the bottom rung. 46 CFR 177.01-5(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2026
Resolved 27 July 2026
Resolution: The deteriorated post was replaced and rewelded.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 14 July 2026 Resolved
An electric apparatus must be designed, constructed, and installed to prevent any person from accidentally contacting energized parts. Dead wires were found aft of the engine and must be capped off. 46 CFR 111.05-3(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2026
Resolved 27 July 2026
Resolution: The dead wires have been capped off.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 9 July 2025 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. CG Marine inspector observed transmission shift cable bulging, split and heavily corroded throughout.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 16 July 2025
Resolved 10 July 2025
Resolution: Shift cable replaced, all sat.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 9 July 2025 Resolved
46 CFR 10.301 The Coast Guard will issue a medical certificate to a mariner meeting the medical and physical standards for merchant mariners. The medical certificate will be issued for various periods of time based upon the endorsements the mariner holds. Master does not hold a valid medical certificate.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 July 2025
Resolved 10 July 2025
Resolution: Medical docs submitted, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 July 2025 Resolved
Nonmetallic hose may be used for wet exhaust systems provided it is especially adapted to resist the action of oil, acid, and heat, has a wall thickness sufficient to prevent collapsing or panting, and is double clamped where practicable. CG Marine inspector observed a loose hose clamp on Main engine wet exhaust.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2025
Resolved 15 July 2025
Resolution: Hose clamp tightened, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 July 2025 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. CG Marine inspector observed Ground strap to starter not attached, Black tank not mounted & vent hose split/kinked.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2025
Resolved 15 July 2025
Resolution: Mounted and replaced hose, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 July 2025 Resolved
Fuel filters fitted with bowls of other than steel construction must be approved by the Commandant and be protected from mechanical damage. Approval of bowls of other than steel construction will specify if a flame shield is required. CG Marine inspector observed no flame shield on plastic fuel water separator bowl.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2025
Resolved 15 July 2025
Resolution: flame shields installed, all sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 9 July 2025 Resolved
Deck rails must be designed and constructed to withstand a point load of 91 kilograms (200 pounds) applied at any point in any direction, and a uniform load of 74 kilograms per meter (50 pounds per foot) applied to the top rail in any direction. CG Marine inspector observed Cracked weld on port side hand rail.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2025
Resolved 15 July 2025
Resolution: Weld repaired, all sat.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 9 July 2025 Resolved
The number of penetrations in a watertight bulkhead must be minimized. A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable, and made watertight. CG Marine inspector observed a severely deteriorated plug in a watertight bulkhead penetration, centerline FWD engine room.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2025
Resolved 15 July 2025
Resolution: Plug replaced, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 July 2025 Resolved
e approved in accordance with § 160.050 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.150. CG Marine inspector observed a missing plastic plug in lifebuoy allowing water intrusion to internal buoyant foam.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2025
Resolved 15 July 2025
Resolution: Replaced life ring, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 October 2024 Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Vessel does not have placard containing instructions for the donning and use of the life jackets aboard the vessel. Vessel must obtain and post such placard. 46 CFR 185.516(a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 October 2024
Resolution: MI received photographic evidence of correction. Def Cleared.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 October 2024 Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets ... Letters and numbers must be at least 2 inches high. The number of life jackets (both adult and child) was not marked as required. Vessel must stencil the number of adult and child life jackets in at least 2" stencils. 46 CFR 185.604(f)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 October 2024
Resolved 4 October 2024
Resolution: MI received photographic evidence of correction. Def Cleared.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 19 October 2020 Resolved
Observed multiple loose rail posts on the starboard side. Also found deteriorated FRP in way of these hand rail posts. Make proper repairs to frp and hand rails. Passengers restricted on bow until proper repairs have been made.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 November 2020
Resolution: Operator provided additional 30 days from due date of 09NOV2020. Observed satisfactory repairs to hull and hand rails.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 19 October 2020 Resolved
Observed several bulkhead penetrations in the forward and aft watertight bulkheads in E/R. Make proper repairs to bulkhead penatrations to maintain watertight integrity.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 October 2020
Resolution: Observed satisfactory repairs to bulkheads.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 19 October 2020 Resolved
Overhead ceiling in E/R is missing insulation. Install insulation or other noncombustible panels meeting 164.009 Qspec.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 October 2020
Resolution: Installed noncombustible insulation.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 19 October 2020 Resolved
Replace gasket for engine room hatch.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 October 2020
Resolution: replaced gasket for hatch.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 October 2020 Resolved
Replace corroded fuel line and lube oil fittings on main engine.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 October 2020
Resolution: Corroded fuel line was replaced.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 19 October 2020 Resolved
Observed multiple loose fasteners on starboard rub rail/hull. Ensure proper installation of fasteners.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 October 2020
Resolution: Loose fasteners were tightened.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 19 October 2020 Resolved
Observed deteriorated decking on 2nd deck in way of ladder. Submit repair proposal and make proper repairs to deck.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 November 2020
Resolution: Provided repair extension: Observed satisfactory FRP repair of 2nd deck flooring.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 19 October 2020 Resolved
Observed corroded port and starboard aft stanchion posts for bimini. Make proper repairs to bimini posts.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 November 2020
Resolution: Provided additional 30 days to correct deficiency. Observed satisfactory repairs to corroded stanchion posts on bimini.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 19 October 2020 Resolved
Found broken wooden planks on transom. Replace broken wooden plank on port side transom.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 October 2020
Resolution: Broken planks were replaced.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 October 2020 Resolved
Provide 1 additional fire bucket.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 October 2020
Resolution: Vessel has a total of 3 fire buckets.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 19 October 2020 Resolved
Provide FCC Safety Radio Certificate.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 October 2020
Resolution: Provided FCC Safety Radio Certificate.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 19 October 2020 Resolved
Provide marine operator radio permit.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 November 2020
Resolution: Provided marine operator radio permit.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 10 August 2018 Resolved
Provide new hydrostatic release for epirb.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 August 2018
Resolution: Provided new hydrostatic release for epirb.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 10 August 2018 Resolved
Provide 01 additional approved flare.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 August 2018
Resolution: Provided all required approved hand flares.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 10 August 2018 Resolved
Provide current FCC Radio Safety Certificate.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 September 2018
Resolved 19 September 2018
Resolution: Provided current readio safety certificate.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.