Inspection history · 18
4 May 2026
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8361345
24 November 2025
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8272363
28 April 2025
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8121281
15 April 2024
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7884736
26 November 2023
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7829539
16 May 2023
DAPI Audit · Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7696676
9 May 2022
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7445211
14 January 2022
Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7380473
1 December 2021
Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7359987
16 April 2021
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7178273
21 July 2020
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6907082
22 November 2019
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6860526
15 April 2019
DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6638121
7 May 2018
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6382120
27 November 2017
Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6313114
24 August 2017
Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6250361
10 May 2017
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6142769
6 May 2016
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5880496
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 May 2026
Resolved
2 portable fire extinguishers were not in compliance. Owner replaced with new prior to end of inspection
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 11 May 2026
Resolved 4 May 2026
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 May 2026
Resolved
1 lifering was found to be in substandard condition. Owner replaced with new one prior to end of inspection
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 11 May 2026
Resolved 4 May 2026
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 April 2025
Resolved
Replace one lifering.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 May 2025
Resolved 30 April 2025
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 28 April 2025
Resolved
Update electronic charts IAW manufacturer recommendation.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 May 2025
Resolved 30 April 2025
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 28 April 2025
Resolved
As vessel utilizes electronic charts for naviggation they are required to have a backup system for charts on an independent power supply - or have currently corrected paper charts.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 May 2025
Resolved 30 April 2025
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 April 2025
Resolved
Remove dead end wires in E/R pt side aft and also in laz.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 May 2025
Resolved 30 April 2025
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 15 April 2024
Resolved
Hydrostatically test bottles
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 May 2024
Resolved 24 April 2024
Resolution: Cleared
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 April 2024
Resolved
Obtain 1, 10 B-C handheld fire extinguisher.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 May 2024
Resolved 24 April 2024
Resolution: Cleared.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 May 2023
Resolved
Vessel required 03 life rings. Vessel only had 02 serviceable life rings.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2023
Resolved 16 May 2023
Resolution: Fixed on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 May 2023
Resolved
Provide a working water light and 60' throw line.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2023
Resolved 14 June 2023
Resolution: Complete
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 16 May 2023
Resolved
Missing items in the first aid kit.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2023
Resolved 14 June 2023
Resolution: Complete
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 May 2023
Resolved
Missing an electrical box cover on an outlet in E/R.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2023
Resolved 14 June 2023
Resolution: Complete
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 16 May 2023
Resolved
The E/R vent closure system was missing a handle. The system could be closed, but only by utilizing a screwdriver. Required handle to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2023
Resolved 14 June 2023
Resolution: Complete
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 16 May 2023
Resolved
The bow thruster emergency fuel shut-off (bow thruster has separate tank) cable had seized.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2023
Resolved 14 June 2023
Resolution: Complete
01 - Certificates & Documentation › 012 - Crew Certificates › Certificate for medical care
Issued 16 May 2023
Resolved
Missing consortium letter.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2023
Resolved 14 June 2023
Resolution: Complete
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 16 May 2023
Resolved
Drills were not logged.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2023
Resolved 14 June 2023
Resolution: Complete
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 16 May 2023
Resolved
The upper deck capacity was not marked in the forward access area.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2023
Resolved 14 June 2023
Resolution: Complete
11 - Life Saving Appliances › N/A - No Subsystem › Means of rescue
Issued 9 May 2022
Resolved
Rescue ladder was not onboard. Provide a rescue ladder.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 9 May 2022
Resolved 9 May 2022
Resolution: O/O provided new ladder.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 December 2021
Resolved
Replace worn forward cutlass bearing for starboard shaft.
Repair prior to credit drydock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 December 2021
Resolved 23 December 2021
Resolution: Verified repair completed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 16 April 2021
Resolved
Provide fuel impingement bowl for primary fuel filter suppling bow thruster engine.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 16 April 2021
Resolved 16 April 2021
Resolution: Witnessed newly installed bowl.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 16 April 2021
Resolved
The person in command of a documented vessel must have on board that vessel the original Certificate of Documentation currently in effect for that vessel. Prior to operating the vessel, provide the vessel's US Certificate of Documentation.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 25 June 2021
Resolved 25 June 2021
Resolution: Original US Documentation updated in MISLE. Original not on board as of 6/25.
Communications › Alarms/Indicators › High Water Alarm
Issued 6 May 2016
Resolved
Provide visual signal for engine compartment high water alarm.
Action required: 705 - Other - as specified
Due 20 May 2016
Resolved 9 June 2016
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 6 May 2016
Resolved
Provide copy of valid FCC Bridge to Bridge Cert
Action required: 705 - Other - as specified
Due 20 May 2016
Resolved 9 June 2016
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 6 May 2016
Resolved
Provide eyewash for 1st Aid Kit. Corrected on the spot.
Action required: 705 - Other - as specified
Due 20 May 2016
Resolved 6 May 2016
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 6 May 2016
Resolved
Replace expired batteries in waterlights with approved batteries.
Action required: 705 - Other - as specified
Due 20 May 2016
Resolved 9 June 2016
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 6 May 2016
Resolved
Repair ladder rung going into lazarette
Action required: 705 - Other - as specified
Due 4 June 2016
Resolved 9 June 2016
Engineering › Bilge Water Management System › Valve
Issued 6 May 2016
Resolved
Prove proper operation of bilge suction. Clean/repair check valves in each compartment and test in presence of USCG MI.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 May 2016
Resolved 9 June 2016
Resolution: Witnessed satisfactory testing of the bilge system in all compartments. 2 valves were changed out b/c they were frozen.