MAURY USCG vessel records Sign in
← All vessels

TX6530DJ

TX6530DJ is a 1984 passenger vessel (inspected). The Coast Guard has recorded 24 inspections since 2001, most recently in March 2026, along with 27 deficiencies.

Records from 2001 to 2026. Most recent: inspection, 5 March 2026.

Built
1984
Last inspected
5 March 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

Flag
UNITED STATES
—
Maury page id
psix-31268

Inspections, by type

…with no type recorded1
Years with a record 18 calendar years (2001–2026)
The 24 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it5 - Regulatory (Subpart C or D), Gross Ton
4 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 24

5 March 2026 COI Inspection · Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8317495
16 October 2024 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8015743
27 February 2024 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7870816
12 October 2023 Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7803457
28 January 2023 Type not recorded
No type recorded · Station Sabine · USCG Heartland District (CGD-H) · Activity 7628494
25 October 2022 Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7579499
26 July 2021 Internal Structural Exam · COI Inspection · Hull Examination
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7261944
16 October 2020 Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7076183
10 October 2019 Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6827634
3 October 2018 Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6553783
27 September 2018 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6549744
23 August 2018 Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6511540
18 September 2017 Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6269596
8 July 2016 Internal Structural Exam · COI Inspection · Hull Examination
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5934169
9 July 2012 Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4373003
25 September 2008 Periodic Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3330806
5 June 2006 COI Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2659002
29 August 2005 Annual Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2473535
13 October 2004 Periodic Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2217113
18 May 2004 Deficiency Check · Plan Review "T" Boat
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2071141
19 March 2004 In-Service Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2029524
9 October 2003 Annual Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1924436
20 May 2002 Damage Survey · Annual Inspection · Simplified Stability Test · Internal Structural Exam · Plan Review "T" Boat
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1618696
16 July 2001 Initial Certification · Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1366456

Deficiency record · 27

11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 March 2026 Resolved
All vessels shall be provided with an approved adult type preserver for each person carried.... Condemned 06 life jackets due to deterioration and no longer serviceable. Reduced the vessel's passenger count to 13 until 06 new life jackets are on board. Old "T" 46 CFR 180.25-5 (a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 7 March 2026
Resolution: Master provided purchase receipt for 06 new lifejackets.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 5 March 2026 Resolved
Each rescue boat and ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant.... Vessel's ring buoy retroreflective tape was worn and needs replacement. 46 CFR 185.604 (i)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 March 2026
Resolved 7 March 2026
Resolution: Master provide a picture of the life ring buoy new reflective tape.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 5 March 2026 Resolved
Employers must maintain records of chemical tests as provided in 49 CFR 40.333 and must make these records available to Coast Guard officials upon request. Vessel was not able to provide documentation showing enrollment in a drug consortium. 46 CFR 16.260(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 March 2026
Resolved 7 March 2026
Resolution: Master provided a letter show participation in drug testing program.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 16 October 2024 Resolved
Marine employers may use sponsoring organizations or contractors to conduct random chemical testing programs. Vessel utilizes a consortium for its random drug testing program but could not produce a valid letter for the Vessel's Captain regarding that.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 November 2024
Resolved 31 October 2024
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 16 October 2024 Resolved
The use of twist-on type wire nuts is permitted under the following conditions; the connections must be made within an enclosure and the insulated cap of the connector must be secured to prevent loosening due to vibration. Vessel utilizes a twist on wire nut for electrical wires on the bilge pump that is exposed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 November 2024
Resolved 31 October 2024
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 October 2024 Resolved
Each vessel must be marked as required by part 67, subpart I of this chapter. The name of the vessel must be marked on some clearly visible exterior part of the port and starboard bow. Vessel only has first 6 digits of name posted.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 November 2024
Resolved 31 October 2024
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 October 2023 Resolved
Each portable fire extinguisher on a vessel must be of an approved type. Table 181.500(b) indicates the minimum required classification for each space listed. A 5-B:C portable fire extinguisher was installed at the operating station. Replace with 10-B:C portable fire extinguisher. {46CFR181.500}
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 October 2023
Resolved 27 February 2024
Resolution: Marine Inspector received documentation from vessel owner verifying installation of new 10-B:C portable fire extinguisher at the operating station.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 October 2023 Resolved
At least one ring life buoy must be fitted with a lifeline. Ring life buoy was not fitted with a lifeline. Attach lifeline to ring life buoy. {46CFR180.70(c)}
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 October 2023
Resolved 27 February 2024
Resolution: Marine Inspector received documentation from vessel owner verifying ring life buoy is now fitted with approved lifeline.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 October 2023 Resolved
Each ring life buoy with a floating waterlight must have a lanyard of at least 3ft, but not more than 6ft, securing the waterlight around the body of the ring life buoy. Water light was not attached to ring life buoy. Waterlight lanyard was deteriorated. Replace lanyard and attach to ring life buoy. {46CFR180.70(d)(2)}
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 October 2023
Resolved 27 February 2024
Resolution: Marine Inspector received documentation from vessel owner verifying installation of new water light lanyard attached to ring life buoy.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 October 2023 Resolved
Flexible hose shall be fabricated with an inner tube & a cover of synthetic rubber or other suitable material reinforced with wire braid. Fuel supply hose was cracked a dry rotted. Replace hose from fuel tank to fuel filter inlet. {46CFR182.15-40(3)}
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 October 2023
Resolved 27 February 2024
Resolution: Marine Inspector received documentation from vessel owner verifying replacement of deterioriated fuel hose with new suitable rubber hose.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 10 October 2019 Resolved
Found 01 portable fire extingishers undercharged.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 October 2019
Resolved 16 October 2020
Resolution: Portable extinguishers were serviced and found in good condition.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 10 October 2019 Resolved
Life Float Light had incorrect battery preventing the proper floatation of the light when in the water.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 October 2019
Resolved 16 October 2020
Resolution: Ring life buoy water light battery was correct and found in good condition.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 10 October 2019 Resolved
Life ring buoy life lines were weathered and dry rotting.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 October 2019
Resolved 16 October 2020
Resolution: Ring life buoy life lines were new and in good condition.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Medical Equipment, medical chest, medical guide
Issued 23 August 2018 Resolved
Vessel had an expired first aid kit.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 September 2018
Resolved 27 September 2018
Resolution: Documentation provide of new first aid kit.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 23 August 2018 Resolved
Vessel had loose connections on installed bilge pump.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 September 2018
Resolved 27 September 2018
Resolution: Vessel showed proper operation of installed bilge pump.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 18 September 2017 Resolved
Vessel failed to have the required number of lifejackets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 October 2017
Resolved 1 November 2017
Resolution: Receipt of purchase for 11 Type I life vest.
Lifesaving › Lifebuoys › Serviceable
Issued 22 July 2016 Resolved
Provide Coast Guard approved life buoy and proper lanyard.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 July 2016
Resolved 22 July 2016
Resolution: Vessel owner purchased Coast guard approves life buoy and proper lanyard.
Lifesaving › Visual Distress Signals (General) › Condition
Issued 22 July 2016 Resolved
Provide Coast Guard approved lanyard for water light.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 July 2016
Resolved 22 July 2016
Resolution: Vessel owner purchased Coast guard approved lanyard for water light.
Lifesaving › Lifebuoys › Stowage
Issued 13 October 2004 Resolved
Life ring had no retro-reflective tape was made fast to the operating station handle.
Action required: 705 - Other - as specified
Due 14 October 2004
Resolved 13 October 2004
Resolution: Installed retro-reflective tape to life ring and removed line from attaching to operating station handle.
Stability
Issued 18 May 2004 Resolved
During review of the plans for adding a canopy to the T boat TX6530DJ, it was discovered that the canopy would change the wind heel moment for the vessel. The vessel was issued an 835 to remove the canopy and conduct and pass a simplified stability test before carrying passengers with the canopy.
Action required: 705 - Other - as specified
Resolved 3 June 2004
Resolution: Stability test passed with 5161.05 of Wind Heeling Moment.
Stability › Incline Test
Issued 19 March 2004 Resolved
Submit plans for approval concerning addition of fixed canopy. Plans should be submitted to [name withheld] with simplified stability calculations.
Due 19 April 2004
Resolved 16 April 2004
Resolution: Received new calculations for TX6530DJ for canopy.
Fire Fighting › Portable CO2 Fire Extinguisher › Pressure Gauge
Issued 9 October 2003 Resolved
Provide (1) B-I extinguisher. Current one onboard shows discharged.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 October 2003
Lifesaving › Lifebuoys › Stowage
Issued 9 October 2003 Resolved
Properly stow life buoy to make readily accessible.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 October 2003
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 9 October 2003 Resolved
Properly secure waterlight to lifebuoy.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 October 2003
Operations/Management › Lifesaving
Issued 9 October 2003 Resolved
Provide lifejacket palcards.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 October 2003
Construction/Loadline › Hull
Issued 14 June 2002 Resolved
Prior to carrying passengers make permanent repairs, approved by [name withheld], to motor mount support. LEGACY COMPONENT DESC: Motor Mount Extension
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 June 2002
Resolution: Temp Repairs effected.
Construction/Loadline › Hull
Issued 6 June 2002 Resolved
Make permanent repairs to the motor mount support prior to 20 June2002. Repairs to be inspected by a USCG Marine Inspector. Vsl may operate in accordance w/ its COI until permanent repair due date. LEGACY COMPONENT DESC: Motor Mount Extension
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 20 June 2002
Resolved 14 June 2002
Resolution: Satisfactory permanent repairs made.

Ownership record