Records from 2016 to 2026. Most recent: inspection, 5 March 2026.
Inspection history · 14
5 March 2026
COI Inspection · Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8317495
16 October 2024
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8015743
27 February 2024
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7870816
12 October 2023
Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7803457
28 January 2023
Type not recorded
No type recorded · Station Sabine · USCG Heartland District (CGD-H) · Activity 7628494
25 October 2022
Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7579499
26 July 2021
Internal Structural Exam · COI Inspection · Hull Examination
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7261944
16 October 2020
Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7076183
10 October 2019
Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6827634
3 October 2018
Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6553783
27 September 2018
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6549744
23 August 2018
Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6511540
18 September 2017
Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6269596
8 July 2016
Internal Structural Exam · COI Inspection · Hull Examination
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5934169
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 March 2026
Resolved
All vessels shall be provided with an approved adult type preserver for each person carried....
Condemned 06 life jackets due to deterioration and no longer serviceable. Reduced the vessel's passenger count to 13 until 06 new life jackets are on board.
Old "T"
46 CFR 180.25-5 (a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 7 March 2026
Resolution: Master provided purchase receipt for 06 new lifejackets.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 5 March 2026
Resolved
Each rescue boat and ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant....
Vessel's ring buoy retroreflective tape was worn and needs replacement.
46 CFR 185.604 (i)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 March 2026
Resolved 7 March 2026
Resolution: Master provide a picture of the life ring buoy new reflective tape.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 5 March 2026
Resolved
Employers must maintain records of chemical tests as provided in 49 CFR 40.333 and must make these records available to Coast Guard officials upon request.
Vessel was not able to provide documentation showing enrollment in a drug consortium.
46 CFR 16.260(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 March 2026
Resolved 7 March 2026
Resolution: Master provided a letter show participation in drug testing program.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 16 October 2024
Resolved
Marine employers may use sponsoring organizations or contractors to conduct random chemical testing programs. Vessel utilizes a consortium for its random drug testing program but could not produce a valid letter for the Vessel's Captain regarding that.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 November 2024
Resolved 31 October 2024
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 16 October 2024
Resolved
The use of twist-on type wire nuts is permitted under the following conditions; the connections must be made within an enclosure and the insulated cap of the connector must be secured to prevent loosening due to vibration. Vessel utilizes a twist on wire nut for electrical wires on the bilge pump that is exposed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 November 2024
Resolved 31 October 2024
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 October 2024
Resolved
Each vessel must be marked as required by part 67, subpart I of this chapter. The name of the vessel must be marked on some clearly visible exterior part of the port and starboard bow. Vessel only has first 6 digits of name posted.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 November 2024
Resolved 31 October 2024
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 October 2023
Resolved
Each portable fire extinguisher on a vessel must be of an approved type. Table 181.500(b) indicates the minimum required classification for each space listed. A 5-B:C portable fire extinguisher was installed at the operating station. Replace with 10-B:C portable fire extinguisher.
{46CFR181.500}
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 October 2023
Resolved 27 February 2024
Resolution: Marine Inspector received documentation from vessel owner verifying installation of new 10-B:C portable fire extinguisher at the operating station.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 October 2023
Resolved
At least one ring life buoy must be fitted with a lifeline. Ring life buoy was not fitted with a lifeline.
Attach lifeline to ring life buoy.
{46CFR180.70(c)}
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 October 2023
Resolved 27 February 2024
Resolution: Marine Inspector received documentation from vessel owner verifying ring life buoy is now fitted with approved lifeline.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 October 2023
Resolved
Each ring life buoy with a floating waterlight must have a lanyard of at least 3ft, but not more than 6ft, securing the waterlight around the body of the ring life buoy. Water light was not attached to ring life buoy. Waterlight lanyard was deteriorated. Replace lanyard and attach to ring life buoy.
{46CFR180.70(d)(2)}
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 October 2023
Resolved 27 February 2024
Resolution: Marine Inspector received documentation from vessel owner verifying installation of new water light lanyard attached to ring life buoy.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 October 2023
Resolved
Flexible hose shall be fabricated with an inner tube & a cover of synthetic rubber or other suitable material reinforced with wire braid. Fuel supply hose was cracked a dry rotted. Replace hose from fuel tank to fuel filter inlet.
{46CFR182.15-40(3)}
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 October 2023
Resolved 27 February 2024
Resolution: Marine Inspector received documentation from vessel owner verifying replacement of deterioriated fuel hose with new suitable rubber hose.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 10 October 2019
Resolved
Found 01 portable fire extingishers undercharged.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 October 2019
Resolved 16 October 2020
Resolution: Portable extinguishers were serviced and found in good condition.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 10 October 2019
Resolved
Life Float Light had incorrect battery preventing the proper floatation of the light when in the water.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 October 2019
Resolved 16 October 2020
Resolution: Ring life buoy water light battery was correct and found in good condition.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 10 October 2019
Resolved
Life ring buoy life lines were weathered and dry rotting.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 October 2019
Resolved 16 October 2020
Resolution: Ring life buoy life lines were new and in good condition.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Medical Equipment, medical chest, medical guide
Issued 23 August 2018
Resolved
Vessel had an expired first aid kit.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 September 2018
Resolved 27 September 2018
Resolution: Documentation provide of new first aid kit.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 23 August 2018
Resolved
Vessel had loose connections on installed bilge pump.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 September 2018
Resolved 27 September 2018
Resolution: Vessel showed proper operation of installed bilge pump.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 18 September 2017
Resolved
Vessel failed to have the required number of lifejackets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 October 2017
Resolved 1 November 2017
Resolution: Receipt of purchase for 11 Type I life vest.
Lifesaving › Lifebuoys › Serviceable
Issued 22 July 2016
Resolved
Provide Coast Guard approved life buoy and proper lanyard.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 July 2016
Resolved 22 July 2016
Resolution: Vessel owner purchased Coast guard approves life buoy and proper lanyard.
Lifesaving › Visual Distress Signals (General) › Condition
Issued 22 July 2016
Resolved
Provide Coast Guard approved lanyard for water light.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 July 2016
Resolved 22 July 2016
Resolution: Vessel owner purchased Coast guard approved lanyard for water light.