Records from 2016 to 2022. Most recent: inspection, 20 October 2022.
Inspection history · 11
20 October 2022
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7581120
8 April 2022
Drydock Exam · Deficiency Check · Internal Structural Exam · Examination of Repairs · Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7416484
29 June 2021
Annual Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7227933
26 March 2021
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 7160533
10 August 2020
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7029055
17 May 2019
DAPI Audit · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6675334
1 April 2019
Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 6654290
24 April 2018
DAPI Audit · Deficiency Check · COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6393018
10 May 2017
Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6138777
3 March 2017
Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6095721
18 April 2016
Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5852780
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 29 June 2021
Resolved
Rules in this subpart (Rules 20-31)shall be complied with in all weathers. Vessel's 360 degrees white light is inoperable.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 July 2021
Resolution: Replaced light in kind.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 10 August 2020
Resolved
Vessel overdue for annual inspection. Complete annual inspection prior to carrage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 August 2020
Resolved 8 September 2020
Resolution: Cleared with an annual inspection.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 10 August 2020
Resolved
Vessel's fire-boy system was removed for servicing due to a failure in the manual override. Vessel is directed to replace the fire-boy system prior to the carriage of passengers.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 September 2020
Resolved 8 September 2020
Resolution: Verified fire-boy system to be placed back in proper service.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 August 2020
Resolved
Vessel's life ring was found deteriorated and unusable. Vessel directed to replace life ring prior to the carriage of passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 September 2020
Resolved 8 September 2020
Resolution: Verified life ring was replaced and placed back in intended service.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 August 2020
Resolved
Life ring light battery found to be inoperable. Directed to replace battery and prove operation prior to the carriage of passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 September 2020
Resolved 8 September 2020
Resolution: Verified battery was replaced in life ring light.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 1 April 2019
Resolved
Due to a storm the bumpers on both the Port and Starboard side quarter were damaged. The Starboard side has exposed holes. Repair or replace the Port and Starboard side aft bumpers.
Condition: Improper/Lack of Maintenance
Due 1 April 2019
Resolved 5 April 2019
Resolution: Both Port and Starboard side quarters were satisfactory repaired.
Engineering › Fuel Oil Service System › Valve, Control
Issued 24 April 2018
Resolved
Emergency fuel shutoff valve must be shielded from flame by same material of hull or some noon combustible material. The valve was plastic.
Condition: Invalid
Action required: 705 - Other - as specified
Due 24 May 2018
Resolved 26 April 2018
Resolution: Replaced fuel shutoff valve.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 24 April 2018
Resolved
The masthead light is inoperable.
Condition: Invalid
Action required: 705 - Other - as specified
Due 24 May 2018
Resolved 26 April 2018
Resolution: Repaired light.
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 24 April 2018
Resolved
The pre engineered fire system cylinder was not operational. Replace cylinder.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 April 2018
Resolved 26 April 2018
Resolution: Installed new pre engineered system.